Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance AZAD NAGAR AZAD NAGAR HARDOI UTTAR PRADESH 241001 UDYAM UP 35 0017189 | HARDOI | UTTAR PRADESH | 241001 | Admitted-Finance |
| 3 | Admitted-Finance HARDOI VAIT GANJ HARDOI HARDOI HARDOI HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
8 May 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Electricity Distribution Circle Asha Nagar Hardoi
Electricity Distribution Circle Asha Nagar Hardoi
16/EDC(H)/2025-26
2025_MVVNL_1035333_1
16/EDC(H)/2025-26
Open Tender
Miscellaneous Works
Item Rate
365 days
EDC Asha Nagar Hardoi
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C No. 066505005389 IFSC Code ICIC0000665
₹32,000
16 May 2025
2 May 2025
9 May 2025
2 May 2025
8 May 2025
2 May 2025
Amount
Safe loading Carriage & unloading of following material from store centre to pit site/JE dump store.
PCC Pole of size 8.5 mtr long
ST pole 11 mtr. Long.
Stay Set Complete
33 KV Pin with Net
Disc insulator With fitting (B&S) 70KN
MS Earthing Rod (2540x20 mm) With Fitting
ACSR Weasel Conductor
GI Wire
11 KV XLPE cable of size 3×185, 3×170, 3×120 sq. mm.
Cable box 3×185, 3×70, 3×120 Indoor & Outdoor
ABC of size (3×120+1×70+1×35) sq. mm.
ABC of size (3×95+1×70+1×35) sq. mm.
ABC of size (3×50+1×35+1×16) sq. mm.
ABC Single Phase of size 1×16+1×25 sq. mm. cable
Replacement of Broken PCC single Pole and Erection of PCC Pole 8.5 mtr long with Grouting & with all accessories
Replacement of Broken PCC double Pole and Erection of PCC Pole 8.5 mtr long with Grouting & with all accessories
Replacement of Broken ST single Pole and Erection of ST Pole 11 mtr long with Grouting & with all accessories
Replacement of Broken ST double Pole and Erection of ST Pole 11 mtr long with Grouting & with all accessories
Re-Stringing of three phase ACSR Weasel Conductor for 11 KV line.
Tilted of PCC/ ST Pole.
replacement of Broken PCC Pole and Erection of PCC Pole 9 mtr long with Grouting & with all accessories
Rebinding of Stay Set Complete.
Laying of 11 KV 3×70/3×120/3×185 sq. mm. XLPE cable by digging of trench size 500 mm wide 900 mm after laying of cable boxing with brick, sand and stone slab.
Erection/Stringing/Sagging and Commissioning of 4×16/4×25 mm cable for ne connection. Cable shall be provided by the contractor at his OWN cast.
Cable hoisting of 11 XLPE Cable on double pole (3×70/3×120/3×185) sq. mm. including jumpering etc. Complete with help of GI Pipe as per RESPO Norms GI Pipe Shall be provided by Contractor
Proper laying & commissioning of 1×16+1×25 sq. mm single phase ABC. Only ABC shall be provided by the department.
Installation of cable box 11 KV Indoor & Outdoor
Proper Laying and Commissioning of (3×120+1×70+1×35) sq. mm. ABC. Only ABC shall be provided by the department.
Proper Laying and Commissioning of (3×95+1×70+1×35) sq. mm. ABC. Only ABC shall be provided by the department.
Repairing of Damage T/F Plinth and including jumpering with the system (All the required martial for above work shall be provided by contractor except T/Fs)Placement of 11/0.4 KV T/Fs with the help of crane sleepers and man power etc. from dump place to newly constructed T/Fs plinth & erection & commissioning of 250/400 KVA T/Fs of
Fabrication erection and commissioning of 25/16/10 KVA T/F on double/single pole with all accessories. All material except 25/16/10 KVA T/F shall be supplied by the contractor.
Construction of retaining wall, fabrication & erection of Wire mesh fencing of size 3 + 3 & 2.0 M height around Transformer and Distribution Pillar Box with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50x6 mm. Wire mesh of size 10 SWG rectangle type, as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost).
Construction of T/F plinth of size 2x2x1.5 m on a padding0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of0.95 mtr height & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. Brick work in ratio1:4cement & cores Sand in the hollow portion the sand should be filled from the ground level upto15 centi meter below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15centimeter. Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand, cement and stone ballast in the ratio of1:2:4.The T/Fs plinth should be plastered on all sides12mm thick in ratio 1:6 by cement and cores sand.(All the material to be arranged by the contractor)
Grouting and Nozzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (sand, brick blast & cement). All material except stay wire shall be supplied by the contractor.
Fixing of Ordinary earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule.
Stringing of three phase ACSR Weasel Conductor for 11 KV line
Guarding of 33 KV Line
Looping & chopping of tree branches for clearance of HT/LT line after clearance of line throughout pieces of tree branches of site (Approx. 3 Km).
M/S RUDRA CONTRACTOR AND SUPPLIER BAREPUR ANDHARRA HARDOI (BID ID -5176476)
Neeraj Electricals (BID ID -5176034)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .