Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹2.0 LAccepted-Finance | ₹2.0 L | 1st | Accepted-Finance 1st Lowest |
| 2 | 2nd₹2.0 LAccepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | ₹2.0 L | 2nd | Accepted-Finance 2nd Lowest |
| 3 | 3rd₹2.0 LAccepted-Finance | ₹2.0 L | 3rd | Accepted-Finance 3rd Lowest |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
22 Mar 2022, 12:00 pmClosed
EE ETD Bijnor
EE ETD BIJNOR 132 KV SUB STATION PREMISES, INDUSTRIAL AREA, BIJNOR
PROVIDING AND FIXING OF NEW 36 KV VACUMME INTERRUPTER OF 33 KV FOR VARIOUS MAKE DAMAGED/DEFECTIVE 36 KV VCB AT 132 KV S/S BIJNOR, UNDER ETD BIJNOR
2022_UPTCL_677062_1
12W/ETBJ/2021-22
Open Tender
Electrical Works
90 days
132 KV S/S Bijnor
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD BIJNOR
₹2,000
25 Mar 2022
3 Mar 2022
22 Mar 2022
3 Mar 2022
22 Mar 2022
3 Mar 2022
Amount
Providing & fixing of New 36 KV vacuum interrupter & insulating pull rod to the pole of various make VCB as per specification. Work includes removing the defective pole assembly from CB, taking down from the top of CB dismantling of damaged vacuum interrupter & pull rod from the pole by the dismantling of pole unit and then reassembling the pole unit with new vacuum interrupter and pull rod safely and mounting the assembled pole unit on the top of the CB and check for satisfactory operation with all associated work to complete the work as per direction of supervising engineer. Circuit Breaker No. 05 Bus coupler CGL make 36 KV VCB Circuit Breaker No. 04 Pili Chowki CGL make 36 KV VCB Circuit Breaker Damaged Pole Shreem make 36 KV VCB Circuit Breaker No. 03 Rampur Bakli Siemens make 36 KV VCB
complete overhauling & servicing of the following 36 KV VCB's of various make. Work includes replacement of its defective parts along with material, if required and checking of its operating mechanism with the help of CRM test Kit and charging mechanism. Removing the defect in the wiring for proper operation, cleaning all parts and oiling greasing for satisfactorily operation of VCB's, Circuit Breaker No. 05 Bus coupler CGL make 36 KV VCB Circuit Breaker No. 04 Pili Chowki CGL make 36 KV VCB Circuit Breaker Damaged Pole Shreem make 36 KV VCB Circuit Breaker No. 03 Rampur Bakli Siemens make 36 KV VCB
P&H Engineering
SATKAR TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid