GE (AF) Halwara
REPAIR / MAINT OF LT INFRASTRUCRUE INCLUDING REPAIR REPLACEMENT OF ELECTRICAL SYSTEM AND GADGETS AT AF STATION BARNALA UNDER GE AF HALWARA
2020_MES_399537_3
GE/HAL-59/2020-21
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹70,700
Yes
6 Mar 2021
10 Feb 2021
26 Feb 2021
10 Feb 2021
24 Feb 2021
10 Feb 2021
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth bottom surface to required gradient complte all as specified and directed.
M&L Removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed.
Material and labour sand cushioning using dry clean sand (Tibba Sand) for protection of underground cable, consolidated and compacted complete all as specified and as directed.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
Taking out following defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor of any Cross sectional area from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
Supply and laying XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 10 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing compete all as specified and directed Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately,
All as per description of item No. 7.00 here-in-before but Cross sectional area 10 sq mm, 2 core
All as per description of item No. 7.00 here-in-before but Cross sectional area 16 sq mm, 4 core
All as per description of item No. 7.00 here-in-before but Cross sectional area 25 sq mm, 4 core.
All as per description of item No.7.00 here-in-before but Cross sectional area 35 sq mm, 3.5 core
All as per description of item No.7.00 here-in-before but Cross sectional area 50 sq mm, 3.5 core .
All as per description of item No.7.00 here-in-before but Cross sectional area 70 sq mm, 3.5 core
All as per description of item No.7.00 here-in-before but Cross sectional area 95 sq mm, 3.5 core
All as per description of item No.7.00 here-in-before but Cross sectional area 185 sq mm, 3.5 core
M&L boring of road crossing of size 80 mm dia at suitable depth not lss than 1 mtr by using machinery / equipments complete without damaging the surface for passing pipes / cables etc including removing excavated soil to a distance n exc 50m complete all as specified and as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while Quotation ing his rates.
Supply and fix as in repairs LT cable route marker / LT cable joint marker made of Jodhpur stone 250mm x 150mm size, 900mm long, with top of oval shaped, two sides engraved with letters 'LT cable', letters painted with approved paint, embedded in ground including necessary excavation and earthwork complete all as specified and directed.
Supply and fixing in replacement M S looping boxes (Bus bar chamber box ) of LT , 415 Volt,32A, 4 Way TPN aluminium bus bars complete clamped to the pole with and including MS clamp made out of flat iron 25 x 3 mm thick, nut, bolts and washers including providing the electrical connection for incoming /outgoing cable through proper lugs/thimbles complete all as directed by Engineer-in-charge.
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connetced with GI earthing strip of size 32mmx6mm thick by means of brazing between GI strip and earth plate min 45 cm in vertical length and GI strip also to be joined by brazing only. The GI earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layer with tibba sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work .
Supply and fix in repairs GI strip 32mm x 6mm in ground / laid in floor / fixed to walletc complete all as specified and diredcted. Note :- Excavation and earth work shall be measured and paid separately.
Dismantling and taking out the old stay assembly complete incl demolition of plain cement all as specified and directed. Note :- (i) Unit rate of this item includes the loose/ disconnect the all accessories which are connected to stay assy including neccessary excavation as directed.
Material and labour for stay assembly complete with accssories as shown in electrical plate No1 including GI adjustable stay rod of 16 mm dia GI stay wire of size 7/4 mm including stay clamps, loop type insulators etc all as specified and directed. Note :- Earth work and PCC work shall me measured and paid separately.
Supply and laying galvanaised steel tube light grade 50 mm dia complete all as specified and directed.
Supply and replacement of silica gel complete contains in the breather assembly all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as specified and directed.
All as per item no 29 above but for HT, 25 x 20 cm size
M & L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work complete all as specified and as directed by Engineer-in-Charge.
M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type) according to to IS colour code by spray machine including writing MES /SM No(letter size shall be 50 mm size) in capital letters s on body for capacity upto 100 KVA transformer outdoor/indoor complete all as specified and directed
All as per item No: 33 but capacity above 160 KVA and upto 630 KVA.
M&L for painting of steel tubular pole 9.0 m long, by applying two coat of alluminum paint after scraping/brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white enammelled paint ( 30 cms each) pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
Material and labour for painting with two coats of synthetic enamel paint on RCC pole from 1.5 mtr above the GL and balance 1.5 m from ground level will be painted by synthetic enamel paint in alternatively black and white strap of 30 cm after scraping /removing the existing paint and the preparation on the surface of RCC LT pole. Pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed..
M & L for cleaning and preparation of surfaces of any existing E/M equipment and applying one coats of synthetic enameled paint (heat resistant type) for writing Mechine no,and writing MES /SM No. in capital letters of suitable size on body and all as specified and directed
M& L trimming of tree branches on both sides of HT /LT aluminium conductor overhead complete all as specified and directed.Note : (i) Cutting branches shall be dumped outside th Air Force premises . (ii) Contractor shall be provide the ladder of required height including T&P to his worker and nothing extra shall be paid on this account.
S&F onload change over switch 100 Amps 4 pole 415 Volts Make : Havells or equivalent
Taking down/Removing existing PCC/Steel poles from site complete all as specified and directed by Engineer-in- Charge. Note: Damaged poles shall be removed from site as per direction of Engineer-in- charge
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-22 (9 metres long)
Taking down old unservicable timer switch with all accessories like contractor, MCB etc all as specified and derected.
S&F Astronomical timer switch 110/240 volts Make : Havells Cat No DHTKW01016 or equivalent
Supplying, fixing and repairs Power contactor 63 Amp 4 pole 415 V 50 Hz model MCX 12 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no CS97014 or equivalent
Supplying, fixing and repairs MCCB of 63 Amps 4 Pole 415 Volt rupturing capacity 16 KA connection with proper size of thimbles complete all as specified and directed.
M&L for cleaning of entire cable duct by removing HT/LT cables from the duct , removing waste materials including sand , and clean the entire duct for plastering
M&L for plastering 10mm thick on fair faces of brick work or stone masonry surfaces or other than fair face of brick work or on one side of lathing in cement mortar 1:4 complete all as specified and directed.
M & L for cleaning and preparation of steel surfaces of existing dull painting of rolling shutter and applying two coats of synthetic enameled paint by spray machine complete all as specified and directed
Taking out ruste/ damaged M.S sheet /PCC/RCC duct covers S&F Fe 410-W (Gde-E- 250)quality- A Fe Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk)forming holes, without anyattachment
M & L for MS works, cross arms, bracing, support clamps and back plate fabricated out of structural steel sections including nuts, bolts and washers, welding, bending hot or cold, cutting, drilling holes for bolts in any shape or size as directed and including one coat of red oxide primer, one under coat and one finishing coat of aluminium paint paint completet all as specified and directed.
M & L replacement of pin type porcelain insulator, vitreous , white brown or green insulator including one galvanised mild steel spindle , two galvanised iron washers and one galvanised iron nut , 150 mm height ,150 mm dia for 11KV grade.
M & L replacement of ACSR jumpers from drop out fuse to GOD and from GOD to bus bar or pole to pole , pole to conductor etc made out of weasel conductor complete for HT/LT OH lines including replacement of thimbles and nut bolts etc. (approximate 4.5 metre length).
Supply and fixing PG clamp die cast aluminium of suitable size and for fixing clampling ACSR conductor connections for PT's CTs isolators all as specefied
Tracing out fault in 11KV U/G cable with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. (Note: (i). Joint kit to be measured and paid separately. (ii) Earth work to be measured and paid separately. (III). All other necessary arrangements suitable for locating the faults is deemed to be included in the rate Quotation ed. (iv) T & P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account )
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
All as per item Sl No 55 here in before but Cross sectional area 120 sq mm, 3 core.
Supply and fixing 11 KV Horn Gap fuse of rated voltage 11 KV and highest system voltage 12 KV, rated current 100/200 Amps, 11 KV Solid core post insulator shall be fitted with all fixing arrangements complete all as specefied and directed.
M&L for painting of steel tubular pole 11.0 m long, by applying two coat of alluminum paint after scraping/brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white enammelled paint ( 30 cms each) pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
Dismantling existing ACSR conductor of any size/type from PCC/Steel poles including taking down MS works such as cross arms, clamps, hooks, stay etc from overhead line complete all as specified and directed by Engineer-in-Charge.
Supply, stringing and fixing ACSR conductor of any type/size on existing poles including fixing to insulators with binding wire or aluminium taps complete all as directed .
Supply & fixing lightening arrestors expulsion type complete with all fittings, suitable for 11000 Volts grade transmission class, discharge capacity 65KA including brackets, clamps, nuts, washers and connecting to 4mm dia GI earth wire complete all as specified and directed.
Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.60m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge.
M&L straight through cable joint kit by using M-seal Kastex cable accessories based on cast resin system ie (electrical insulation, mechanical protection and moisture imperviousness to the joint) for LV PVC / XLPE cable up to 50 sq mm x 3.5 / 4 core 1100 volt grade at site (technical / domestic area) complete all as specified and directed .
All as per description of serial item No. 63 here in before but size up 70 sq mm x 3.5 core
All as per description of serial item No. 63 here in before but size up 95 sq mm x 3.5 core
All as per description of serial item No. 63 here in before but size up 120 to 150 sq mm x 3.5 core
All as per description of serial item No. 63 here in before but size up 185 sq mm x 3.5 core
All as per description of serial item No. 63 here in before but size up 240 sq mm x 3.5 core
Supply and fix double compression heavy duty brass cable gland Nickle plated weather proof for fixing armoured cable in panel ofsize 16 sq mm 4 core all as specified and directed.
All as per description of serial item No 69.00here in before but cable size 25 sq mm 4 core
All as per description of serial item No 69.00here in before but cable size 35 sq mm 3.5 core
All as per description of serial item No 69.00 here in before but cable size 50 sq mm 3.5 core
All as per description of serial item No 69 here in before but cable size 70 sq mm 3.5 core
All as per description of serial item No 69 00 here in before but cable size 95 sq mm 3.5 core
All as per description of serial item No 69.00 here in before but cable size 120 sq mm 3.5 core
All as per description of serial item No 69 here in before but cable size 150 sq mm 3.5 core
Supply only MCCB 25 KA, 4 pole, 400A
Supply only MCCB 25 KA, 4 pole, 200A
Supply only MCCB 25 KA, 4 pole, 160A
Supply only MCCB 25 KA, 3 pole, 200A
Supply only MCCB 25 KA, 3 pole, 100A
Supply only Indicator lamp RYB
Supply only volt meter analog type 0-500 Amp
Supply only Amp meter analog type 0-200 Amp with CTs
Repair/maint of Diesel engine sets 100 KVA capacity ,Checking and servicing of engine for smooth running, its unusual sound and color of smoke from exhaust and set it right in case of deviations, Checking and repairing the leakage of fuel, lubricating oil and coolant,Setting of Valves tappets whenever required.Checking and repairing of Accessories drive, Turbo Charger and crankshaft endplay,Checking alignment of Engine and Alternator,Checking of throttle control & its setting,Checking of instrument on instrument panel,Checking of rotating diodes assembly in brushless alternator,Checking of wiring system and repairing if required,Repair and Maintenance of Relays including contactors in control panel. Checking and cleaning of battery terminal and de-sulphation. Diagnosis of faults in engine and Alternator and its rectification. Checking Self Starter and accessories all as specified and as directed by Engr-In-Charge.
All as per description of serial item No 86 here in before but 75 KVA
All as per description of serial item No 86 here in before but 45 KVA
All as per description of serial item No 86 here in before but 30 KVA
All as per description of serial item No 86 here in before but 10 KVA
Supply & replacement of following parts during B Check Diesel engine generator Service suitable for Generator set mentioned in item No 86 to 90 (a) Fuel Filters
(b) Lubricating oil fiilters
© By pass filters
(d) Coolant
(e) Air Filters
Lubricating Oil
S&F contactor 200 Amp 4 pole including necessary connection with suitable size of copper conductor.
Supply and fix in replacement Automatic voltage regulator for alternator of DG set 75 KVA.
M&L for servicing including testing of self starter 12/24 Volt including replacement of armature, gun metal bush, solenoid switch, bentex clutch plate, push button including refixing, testing and commisioning complete all as specified and directed by Engr-In-Charge.
M&L for opening taking down the complete radiator assembly and descaling the complete radiator with HCL acid and washing testing of water leakage if any and repair the same and refixing the radiator assembly of DG set capacity 75 KVA complete all as specified and directed by Engr-In-Charge.
M&L for repair to fuel injecting pump (FIP) of 30 KVA to 100 KVA DG sets of make Mahindra/kirloskar including supply and replacement of element delivery valve,nozzle, delivery valve pin with bearing , deliver valve spring etc and including calibration of pump and injector pressure setting , fitting and testing complete all as specified and directed.
S&F battery lead of copper conductor 1.5 M long with battery terminal and lugs complete all as specified and directed.
S&F in replacement battery 12 volt ,180 AH, 25 Plates including testing for its proper functioning complete all as specified and directed.
S&F in replacement of fan belt for DG set of capacity 75 KVA complete all as specified and directed.
Disconnecting and taking out of DG set 75 KVA Make :- kirlosker No of Cylinder :- 06 including disconnecting all electrical connections and transporation to work shop and back after carry out necessary repair and replacement of worn out defective parts including preventive maintaince of connected assemblies. Reassembling the same after repairs including testing and commissioning at site complete. including replacement of the following spare parts .(Note :- cost of spare parts to be replaced will be masured and paid seperatly under item Nos 106 to 115 here in after under respecive items but cost of replacement shall be deemed to be included in this item.)
Supply only cylinder Liner.
Supply only Piston
Supply only Piston ring set
Supply only exaust valve seat.
Supply only inlet Valve seat
Supply only valve pair
Supply only Hose flexible
Supply only Element Air Filter inner.
Supply only CAM gear Assembly
Supply only turbo charger Assembly
M/S SANGA SINGH AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .