Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAdmitted-Finance | ₹5.2 L | L1 | Admitted-Finance |
| 2 | L2₹5.7 LAdmitted-Finance | ₹5.7 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical EMD/FDR Not Submitted |
| 4 | Rejected-Technical 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | - | - | Rejected-Technical EMD/FDR Not Submitted |
| 5 | Rejected-Technical | - | - | Rejected-Technical EMD/FDR Not Submitted |
| Sl No | Description | Qty | Unit | ROYAL ELECTRICAL CO. L2 | HYDROCON ENGINEERS L1 |
|---|---|---|---|---|---|
| 1.00 | Providing & fixing of indicating lamps RYB along with complete wiring of above Electrical components and with suitable size copper conductor wire (6sq mm, 4 sq mm , 2.5 sq mm & 1.5 sq mm) and suitable size ferrule/socket of required size insulating board i/c replacement of old and damaged components with above mentioned materials. Job i/c Testing & commissioning of complete panel board on load as per site requirement. | 6 | Jobs | 75,000 ₹88,500 | 63,000 ₹74,340 |
| 2.00 | S/o MS nut bolts off size as per requirement. | 50 | Kg, | 6,250 ₹7,375 | 5,000 ₹5,900 |
| 3.00 | S/o Double flanged G.I pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with G.I flange on both ends having the slot for sub cable. Make: - Tata/Jindal | 60 | Nos. | 2,55,000 ₹3,00,900 | 2,52,000 ₹2,97,360 |
| 4.00 | S/o PVC insulated PVC sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (Each roll of 100 mtrs.) Make: - Grandlay/Havells/gloster/DJB approved | 3 | Rolls | 67,500 ₹79,650 | 43,500 ₹51,330 |
| 5.00 | S/o Rubber packing 50 mm dia. flange. | 60 | Nos. | 3,000 ₹3,540 | 6,000 ₹7,080 |
| 6.00 | Lowering & lifting of sub/sets from bore by taking out double flanged GI pipes, submersible P/Set, Cable, cutting of rusted nutsand boltsetc and replacement of damaged D/F GI pipes, cable, defective pump set etc as per site requirement and lowering of sub P/set, sub cable, GI Pipe etc as required, jointing of cable from sub P/Set along with holding of cable with pipes and jointing of D/F pipes etc with nutsbolts and rubber packing etc. The job includeshiring of all T&P, tripod stand, chain pulley block and other material handling equipments, Safety gadgets as required will be arranged by the firm as per site requirement. The other material required during execution will be provided by department. | 6 | Jobs. | 75,000 ₹88,500 | 75,000 ₹88,500 |
Tender Value
Refer Docs
EMD Value
₹10,800
Closing Date
5 Jan 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (EM) M-11
GREATER KAILASH, PART-I, NEW DELHI
Replacement of electrical and mechanical items of various tube wells installed in Manbhari Kunj under Badarpur Constituency AC-53.
2025_DJB_283549_7
NIT No. 21/EE(EM)M-11/(25-26)
Open Tender
Electrical Work/ Equipment
30 days
EXECUTIVE ENGINEER (E/M) M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹10,800
Yes
12 Mar 2026
24 Dec 2025
5 Jan 2026
24 Dec 2025
5 Jan 2026
24 Dec 2025
Providing & fixing of indicating lamps RYB along with complete wiring of above Electrical components and with suitable size copper conductor wire (6sq mm, 4 sq mm , 2.5 sq mm & 1.5 sq mm) and suitable size ferrule/socket of required size insulating board i/c replacement of old and damaged components with above mentioned materials. Job i/c Testing & commissioning of complete panel board on load as per site requirement.
S/o MS nut bolts off size as per requirement.
S/o Double flanged G.I pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with G.I flange on both ends having the slot for sub cable. Make: - Tata/Jindal
S/o PVC insulated PVC sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (Each roll of 100 mtrs.) Make: - Grandlay/Havells/gloster/DJB approved
S/o Rubber packing 50 mm dia. flange.
Lowering & lifting of sub/sets from bore by taking out double flanged GI pipes, submersible P/Set, Cable, cutting of rusted nutsand boltsetc and replacement of damaged D/F GI pipes, cable, defective pump set etc as per site requirement and lowering of sub P/set, sub cable, GI Pipe etc as required, jointing of cable from sub P/Set along with holding of cable with pipes and jointing of D/F pipes etc with nutsbolts and rubber packing etc. The job includeshiring of all T&P, tripod stand, chain pulley block and other material handling equipments, Safety gadgets as required will be arranged by the firm as per site requirement. The other material required during execution will be provided by department.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.30 MB
BOQ_374881.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid