GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT-145001
REPAIR/MAINT OF REFERIGERATORS, DEEP FREEZERS, ACs AND VOLTAGE STABILIZERS, DESERT COOLERS, WATER COOLERS, UNDER GE (SOUTH) MAMUN
2023_MES_601735_1
GE(S)/M-10/2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
GE SOUTH MAMUN
AS PER NIT
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹40,000
Yes
27 Jul 2023
7 Jun 2023
12 Jul 2023
7 Jun 2023
5 Jul 2023
21 Jun 2023
Amount
Repair & maint of water cooler 40/80 Ltr capacity by disconnecting and taking down old u/s burnt compressor unit and S&F with new company manufactured sealed unit compressor complete with initial filling of gas confirming to ISI suitable for existing water cooler including testing, complete unit for required performance and smooth functioning for 24 Hrs complete with checking internal wiring, cleaning, flushing condensing coil, cleaning to tank etc complete all as specified and directed. Notes (For Srl item No. 1 to 4) :- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/MES store yard.
All as per srl item No. 1 here-in-before but for 40/40 Ltrs capacity water cooler complete all as specified and directed.
All as per srl item No. 1 here-in-before but for 60/120 Ltrs capacity water cooler complete all as specified and directed.
All as per srl item No. 1 here-in-before but for 150 Ltrs capacity water cooler complete all as specified and directed.
Material and labour for repairing to bottom base/stand of water cooler of any make/type/capacity including welding of MS/GI sheet 16 SWG of suitable size to fill up rusted patches, grinding and applying base material for smooth surface and applying 2 coat of synthetic enamel spray paint of existing colour over one coat of primer etc complete all as specified and directed.
S&F in replacement of old unserviceable starting relay with overload protector for water cooler of any cap, complete all as specified and directed.
S&F in replacement of running capacitor 10/15/20 mfd for water cooler complete all as specified and directed.
S&F in replacement of old unserviceable push cock / bib cock tap, copper alloy chromium plated of 15mm bore, matching to the existing one, complete all as specified and directed.
S&F in replacement of old unserviceable fan blade for water cooler fan motor of type and size matching to existing sample and size complete all as specified and directed.
S&F in replacement of old unserviceable fan motor of cap 1/10 HP, single phase, 230 volt suitable to existing type water cooler complete all as specified and directed.
All as per srl item No. 10 here-in-before but 1/35 HP, single phase, 230 volt complete all as specified and directed.
S&F in replacement of old unserviceable thermostat as per existing sample/make for water cooler of any capacity, complete all as specified and directed.
S&F in replacement of old unserviceable PVC waste water pipe with clamp, suitable to existing size for water cooler of any cap, complete all as specified and directed.
S&F chromium plated water tray basin for water cooler of any cap matching to the existing including taking down old one and removal from site, complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler including repairing the dented surface by applying putty and removing old paint cleaning and applying two coats by spray painting of approved colour, writting the SM /Ser No / unit name and date of repair of machine complete all as specified and directed. Note :- Colour code shall be approved by Engineer-in-Charge.
S&F in replacement 15mm dia PTMT float ball valve complete for desert & water cooler, complete all as specified and directed.
S&F in replacement PVC connection pipe of 15mm dia, 450/600mm long (as required at site) with brass nut at both ends for desert and water cooler, complete all as specified and directed.
S&F in replacement of starting capacitor 100/120 mfd complete all as specified and directed.
Replacement of old unserviceable / damaged condensing coil with new condensing coil matching to existing one for water cooler of cap any type , complete all as specified and directed.
M&L for rewinding of desert cooler fan motor of 1/7HP or 1/8 HP single phase, 3 speed with super enameled copper wire of appropriate gauge with insulating material complete after removing old burnt aluminium/copper wire including replacement of unserviceable bush, bearing etc, complete all as specified and directed. Note :- Nothing extra is admissible to contractor, If old burnt aluminium winding wire found in the motor & to be replaced with super enameled copper winding wire.
S&F in replacement of old unseviceable desert cooler fan motor of cap or 1/7 HP or 1/8 HP operate in three speed with super enamelled copper bound wire of appropriate gauge with insulating materials, single phase including making necessary electrical connection and testing at site, complete all as specified and directed.
S&F in replacement of old unserviceable water lifting submersible pump for desert cooler, single phase, 165-250 volts, 18watt and making necessary connection to power supply complete all as specified and directed.
S&F in replacement 3 way PVC water distributor with PVC elbow - 03 Nos as per sample for desert cooler including nuts and bolts, suitable for one desert cooler complete, all as specified and directed.
S&F in replacement of old unserviceable wood wool pad with good quality wood wool pad set as per sample, complete all as specified and directed.
S&F in replacement of capacitor 4.0 mfd for desert cooler complete all as specified and directed.
S&F in replacement old unserviceable side shutter/ grill for desert cooler, made out of 1.0 mm thick GI sheet, matching to existing size and sample complete all as specified and directed. Note: The khas pad/ wood wool pad for side shutter shall be measured and paid separately under relevant item.
S&F in replacement of old unserviceable desert cooler water tank, made out of min 1 mm thick GI sheet to match existing desert cooler body size and sample, complete all as specified and directed.
S&F in replacement of old unserviceable fan blade made in supper quality plastic for desert cooler of any type as per existing sample, complete all as specified and directed.
S&F in replacement of old unserviceable Switch, piano type, one way, 5 Amps complete all as specified and directed.
S&F in replacement of old unserviceable PVC flexible pipe of 15mm dia as per sample and making necessary connection for desert cooler as per sample complete all as specified and directed.
S&F in replacement of 5 Amp plug top, 3 pin complete all as specified and directed.
S&F in replacement of old unserviceable PVC insulated, sheathed, stranded copper conductor cable of size 0.75 Sqmm, 3 core, 1100 volt grade, incl connection and testing, complete all as specified and directed.
M&L for preparation of old painted surface of desert cooler including removing old paint, repairing the dented surface by applying putty and applying two coats by spray painting of approved colour,,writting the SM /Ser No / unit name and date of repair of machine complete for one desert cooler all as specified and directed. Note :- Colour code shall be approved by Engineer-in- Charge.
M&L for replacement of flat iron size as per existing sample of desert cooler motor leg all as specified and directed.
Repair and Maint of window/split AC 1.5 Ton capacity by disconnecting and taking down old unserviceable burnt compressor unit and S&F with new company manufactured sealed unit compressor complete with initial filling of gas confirming to ISI suitable to existing AC including testing complete unit for required performance and smooth functioning for 24 Hrs, complete with checking internal wiring , cleaning , flushing to condensing coil , cleaning to tank etc complete all as specified and directed. Notes for item No 37 & 38 :- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/MES store yard.
All as per srl item No. 37 here-in-before but of Split/window type AC of capacity 2.0 Ton complete all as specified and directed.
S&F in replacement of starting capacitor 36 or 50 + 6 mfd as required at site complete all as specified and directed.
S&F in replacement of starting relay with overload protector suitable for split/ window AC any cap complete as per existing sample complete all as specified and directed.
S&F in replacement of anti-bacteria air filter as per sample for split/window type AC of any capacity complete all as specified and directed.
S&F in replacement of blower for split/window type AC complete as per existing sample complete all as specified and directed.
S&F in replacement of sheet metal enclosure (industrial type) with a two pin and earth plug and socket with including MCB 20/32 Amp MCB Double Pole, 240 volts complete all as specified and directed.
S&F in replacement of MCB SP 20 to 32 Amp, C curve complete all as specified and directed.
S&F in replacement of 15 Amp plug top, 3 pin complete all as specified and directed.
S&F in replacement of old unserviceable PVC insulated, sheathed, stranded copper conductor cable of size 2.5 Sqmm, 3 core, 1100 volt grade, incl connection and testing, complete all as specified and directed.
S&F in replacement of plug top (male)16 Amps for sheet metal(industrial) enclosure complete all as specified and directed.
S&F in replacement of old unserviceable swing motor for 1.5/2.00 Ton split AC/ window type AC as per sample and existing make, complete all as specified and directed.
S&F in replacement of old unserviceable condenser coil/ evaporator coil (cooling coil) suitable for split AC/ window AC 1.5/ 2.0 Ton including welding/ soldering at site, all as per sample complete all as specified and directed.
S&F in replacement of old unserviceable PCB circuit with remote,display, board, display sticker, Transformer, suitable for window / split type AC of any type and any capacity including all electrical connections at site, complete all as specified and directed.
S&F in replacement of outer unit for 1.5 Ton Split AC with sealed unit, condensor motor couple prewired complete all as specified and directed.
S&F in replacement old unserviceable PVC front grill as per existing sample for window type AC 1.5/ 2.0 Ton complete all as specified and directed.
Dismantling/ opening the split AC/ window type AC 1.0 / 1.5 / 2.0 ton capacity from the site and supply and fixing reversible cycle valves in existing AC to function for cooling or heating system including electrical connection, refixing the AC at it's position and testing, complete all as specified and directed.
S&F in replacement of old unserviceable blower motor (as per sample) double shaft having for 1.5/ 2 Ton window AC, complete all as specified and directed.
S&F in replacement of old unserviceable indoor unit blower motor for split AC 1.5/ 2.0 Ton as per sample complete all as specified and directed..
Supply & fixing in replacement of inner unit for 1.5 Ton Split AC with sealed unit, Condensing unit, condensor motor couple prewired complete.
Supply & fixing in replacement of inner unit for 2.0 Ton Split AC with sealed unit, Condensing unit, condensor motor couple prewired complete.
S&F in replacement of old unserviceable discharge service valve as per sample for Split AC of any type complete all as specified and directed.
S&F in replacement old unserviceable condensing coil fan motor for Split AC 1.5/ 2 Ton as per sample complete all as specified and directed.
S&F in replacement of unserviceable copper pipe ½" dia as per sample complete all as specified and directed.
S&F in replacement of unserviceable copper pipe ¼" dia as per sample complete all as specified and directed.
S & F in replacement of new nitrile rubber insulation tube for split air conditioner copper pipes of any size upto 1/2" dia complete all as specified and directed.
M&L for fixing white Putty for repair work reqd at site complete all as specified and directed.
M&L for fixing M-Seal water proof in ACs window/split type, complete all as specified and directed.
M&L for replacement of liquid line valve of suitable size for Split AC, complete all as specified and directed.
Supply in replacement of remote control suitable to existing window/split type ACs (As per sample & existing make) complete all as specified and directed.
M&L for servicing at site of window/ split AC of any type, any size by opening , cleaning, re-fixing the filters, cleaning & washing of condenser and evaporator coil with brushes, chemical etc. including taking down and refixing in position of AC, if reqd for satisfactory functioning of AC complete all as specified and directed. Note : Gas and spare parts are measure for separately.
Disconnecting and taking out of split AC indoor and outdoor unit by cutting of copper tube and disconnecting of electric cable & shifting of indoor/outdoor unit to another or same location with refilling refrigerant gas and fixing, making elect connections & testing after connecting all the parts in position, complete with any civil work to pass the copper pipes through wall complete all as specified and directed. Note: The rate quoted include the cost of charging/re-filling the required refrigerant/gas.
S&F in replacement of factory made MS bracket of thickness min 6mm duly painted suitable for installing outdoor unit of 1.5 / 2.0/ 3.0 TR Air Conditioner complete all as specified and directed.
M&L for fabrication of frame work/ MS stand for voltage stabilizer, water cooler, window AC, desert cooler made from angle iron, flat iron, rolled bar, wire mesh, GI sheet etc. quality confirming to Fe-410-W or Gde-E 250 quality -A with including drilling holes, cutting & welding, fixing with nut & bolts etc., painting with two coats of approved paint complete with locking arrangement, grouting in wall / floors etc. and make good the disturbed surfaces including required cement /bricks etc, complete all as specified and directed.
Repair and maint of deep freezer of 120 to 295 ltr capacity by disconnecting and taking down old unserviceable burn compressor unit and Supply and fixing new company manufactured sealed unit compressor complete with initial filling of Gas confirming to IS suitable for existing deep freezer including testing ,complete unit for required perfermance and smooth functioning for 24 Hrs complete including checking internal wiring , cleaning , flushing to condensing coil, cleaning to tank etc. complete all as specified and directed . Note for item Sr No 72 & 73:- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All Engineering works shall be carried out at site/ MES store yard and in presence of Engineer-in-Charge.
All as per srl item No. 73 here-in-before but capacity 300 Ltrs to 500 Ltr complete all as specified and directed.
S&F in replacement of old unserviceable starting relay as per sample for deep freezers of any capacity, complete all as specified and directed.
S&F in replacement of old unserviceable thermostat switch as per sample for deep freezer of any capacity, complete all as specified and directed.
S&F in replacement of old unserviceable blower motor as per sample for deep freezer complete all as specified and directed.
Supply and fixing in replacement of Door Lock with door gasket for refrigerator 165 to 310 ltrs complete all as specified and directed.
M & L for replacement of deep freezer outer body 310 ltr capacity including all accessories as per existing make approved by Engr-in- charge.
Repair and maint of refrigirator 165 to 210 Ltrs capacity by disconnecting and taking down old unserviceable burnt compressor unit and S&F with new company manufactures sealed unit compressor complete with initial filling of gas confirming to ISI suitable to existing refrigirator including testing complete unit for required performance and smooth functioning for 24 Hrs complete with checking internal wiring , cleaning , flushing to considering coil , cleaning to tank etc complete all as specified and directed. Notes for item Sr No 79 & 80 :- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/ MES store yard and in presence of Engineer-in-Charge.
All as per srl item No. 80 here-in-before but of capacity 215 to 320 Ltrs complete all as specified and directed.
S&F in replacement of old unserviceable cooling coil freezer/ evaporator assy as per sample for refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unserviceable condensing coil assy as per sample for refrigerator of any capacity, any type (single door/ double door) complete all as specified and directed.
S&F in replacement of old unserviceable auto defrost thermostat switch as per sample for refrigerator of any capacity complete all as specified anf directed.
S&F in replacement of old unserviceable starting PTC relay with OLP as per existing sample for Refrigerator of any cap complete all as specified and directed.
S&F in replacement of old unserviceable cooling coils (fins and tube type/ pressed type) for double door refrigerator (as per sample required at site) complete all as specified and directed.
S&F in replacement of old unserviceable timer as per sample for double door refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unserviceable Bimetal thermostat assy as per sample for double door refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unserviceable blower motor/fan motor as per sample for double door refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unserviceable heater as per sample for any capacity refrigerator complete all as specified and directed.
S&F in replacement of old unserviceable transparent vegetable tray as per sample for any capacity refrigerator complete all as specified and directed.
S&F in replacement of old unserviceable wire shelf set as per sample for any capacity refrigerator complete all as specified and directed.
S&F in replacement of old unserviceable electronic control board (PCB) as per sample for refrigerator of capacity 280 Ltrs to 310 Ltrs including connection, complete as specified and as directed.
M&L for charging refrigerant gas R-22 in old or new compressor and make up required pressure including brazing and testing, complete all as specified and directed.
Supply and fixing in replacement of Interior light fittings with bulb for refrigirator of any size and any capcity complete all as specified and directed.
M&L for charging refrigerant gas R-134a or 410a in old or new compressor to make-up required pressure including cutting piping, brazing and testing, complete all as specified and directed.
M&L for writing SM Number / MES No , Unit and date of repair on refrigerator / deep freezer and AC with paint of standard, text height complete all as specified and directed by Engr-in-Charge. Note: The writing of SM/MES No at one equipment shall be measured as one unit.
M&L for repair of voltage stabilizer of 1/2 KVA of any type including replacement of spare parts such as transformer, PCB, diode, condenser, preset ic , volt meter, ammeter, indicator lamp, socket outlet and any other parts as required for proper functioning of stabilizer complete along with testing and transportation charges from site to workshop, complete all as specified and directed.
All as per srl item No. 97 here-in-before but capacity 3/4 KVA complete all as specified and directed.
All as per srl item No. 97 here-in-before but capacity 5 KVA complete all as specified and directed.
Supply of CTC (commercial technical chemical) for flushing of refrigerator & deep freezer lines to remove choking all as specified and directed.
S&F copper coil capillary tube for Refrigerator/ Deep freezer as per sample size complete all as speciifed and directed.
S&F in replacement of old unserviceable copper Pencil filter drier with new drier filter having desiccant complete including necessary cutting, removing old drier filter with reqd brading work for Refrigerator, Deep Freezer any cap complete all as specified and directed.
M&L for replacement of Gas charging pin valve for any type of AC as per sample complete all as specified and directed.
M/S SAROOP ELECTRICAL & MECHANICAL WORKS
VIRAT CONSTRUCTIONS
GARG CONSTRUCTION CO
M/S MALHI CONSTRUCTIONS
Bidder Name
GARG CONSTRUCTION CO
M/S NILESH ENTERPRISES
M/S MALHI CONSTRUCTIONS
VIRAT CONSTRUCTIONS
M/S SAROOP ELECTRICAL & MECHANICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .