Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹34.1 L+₹80,705.37 (2.43%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹35.3 L+₹2.0 L (6.01%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹35.7 L+₹2.5 L (7.37%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹35.9 L+₹2.6 L (7.77%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Jan 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
REPAIR/ REPLACEMENT OF SEWAGE LINE MAN HOLE, RAIN WATER, EXTERNAL DRAIN AND MISC WORKS INCLUDING REPAIR/ MAINT OF E/M WORKS AT RRRC, 105 TA, KARAN VIHAR, URI ENCLAVE, SABRE MESS, 202 BD CO, RR COLONY, KANDHAR LINE, TODAPUR, CHURCH, GYM ROAD AND ADJO
2023_MES_633801_1
GE/C-68/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
1 Feb 2024
21 Dec 2023
20 Jan 2024
21 Dec 2023
18 Jan 2024
4 Jan 2024
21 Dec 2023 - 4 Jan 2024
Amount
Cleaning of EWCs, IWCs, bottle traps, Nahani Traps, Gully traps and Floor traps etc and CI/PVC Pipes all types top to bottom including junctions etc, Cleaning of sewage line upto GT in the area of RRRC (Md accn and all types of Accn including multistory bldg ). complete all as specified and as directed.
Cleaning of Manhole depth of 0.9 mtr and any size of MH in the area of RRRC (Md accn and all types of Accn) and taking out sludge and depositing complete all as specified and as directed.
Cleaning of Manhole depth exc 1.2 mtr and above of any size of MH in the area of RRRC (Md accn and all types of Accn) omplete all as specified and as directed.
Cleaning of Sewage line from GT to Ist Manhole in the area of RRRC and (Md accn and all types of Accn) complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to300mm.
Cleaning of sewage line n.exc 15mtr length in the area of RRRC and (Md accn and all types of Accn). complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to 300mm.
Cleaning of Sewage line 0.00mtr to 10.00mtr in length in the area of RRRC and (Md accn and all types of Accn) complete all as specified and as directed. (Note :- This item will be measured if length exceed from 15.00mtr.and cleaning of sewage line daimeter upto 100mm to 300mm.
Cleaning of Sewage line 0.00mtr to 20.00mtr in length in the area of RRRC and B (Md accn and all types of Accn) complete all as directed and as specified. Note :- This item will be measured if length exceed from 20.00mtr.and cleaning of sewage line daimeter upto 100mm to 300mm.
Cleaning of Sewage line 0.00mtr to 30.00mtr and onwards in length in the area of RRRC and (Md accn and all types of Accn) complete all as directed and as specified. (Note :- This item will be measured if length exceed from 30.00mtr.and cleaning of sewage line daimeter upto 100mm to300mm. Note :- For execution of item from Srl No. 1 to 8 above Agency should deploy minimum of 04 Nos Safaiwala and 01 Nos Supervisors on all days of the month/year during the contract period including Sunday and Holidays so as to complaints are attended promptly within 02 hours so that health and life of troops and their families is not adversly affected. The contractor shall take immediate action to attend any complaint assigned to him through site order book/verbal instructions from Engineer-in-charge or on telephones, MES call centres/IVRS from occupants. In all cases he shall attend the complaints in the specified duration. Penalty for non attending Complaints:- (a) Complaint pending 3-24 hours-500 Rupees per complaint.
Taking down Cement plaster on brick walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc omplete all as specified and as directed. Engr-in-Charge .
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even complete.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specifed as direted by Engr-in-charge.
M&L for complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat of cement based paint complete all as specified and directed.
Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortor of any diameter incl bends.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc including taking out/dismentling of old pipe complete all as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc including taking out/dismentling of old pipe complete all as specified.
S&F PVC (SWR) bends any radius, 110 mm bore complete.
S&F PVC (SWR) bends any radius, 75 mm bore complete.
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 75mm complete all as specified and directed.
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 100mm complete all as specified and directed.
S&F in repair 100 mm bore cast iron bends complete all as specified and as directed.
S&F in repair 75 mm bore cast iron bends complete all as specified and as directed.
M&L for 200mm salt-glazed stoneware drain pipes laid in trenches and jointed mplete all as specified and as directed.
Supply and laying, DWCPE(SN8) 150 mm dia pipes and snap fit coupler incl testing and laid properly, jointed laid in teenches to a level on concrete bed complete all as specified.
Supply and laying, DWCPE(SN8) 200 mm dia pipes and snap fit coupler incl testing and laid properly, jointed laid in teenches to a level on concrete bed complete all as specified.
M&L for cement concrete 1 : 4 : 8, type D2, using 40mm graded stone aggregates in complete all as specified. (thickness of concrete bed 100mm).
M&L for cement concrete 1 : 4 : 8, type D2, using 40mm graded stone aggregates in complete all as specified. (thickness of concrete bed 100mm).
Demolation Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified .
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in Cm 1:6 all as specified and directed.
Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 incl demolition of brick work built in cement mortar compolete all as specified and directed.
S & F in replacement precast fibre reinforced cement concrete Manhole cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 450mmx450mmx50mm omplete all as specified and as directed.
S & F in replacement precast fibre reinforced cement concrete Manhole/drain cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mm x50 mm omplete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section) in cement concrete 1 : 2 : 4 type B1 using 20mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified.
M&L for Dewatering and desludging of septic tanks of 200 users capacity using( mechanical device system) by dewatering sludge water and removing sludge/waste material etc. through container/tanker to a distance exc 5KM and complete all as specified and directed by the Engr-in-Charge.
M&L for Dewatering and desludging of septic tanks of 100 users capacity using( mechanical device system) by dewatering sludge water and removing sludge/waste material etc. through container/tanker to a distance exc 5KM and complete all as specified and directed by the Engr-in-Charge.
Mechanically used water fitting Hydraulic pressure machine and water sucking hydraulic pressure machine jet press for cleaning of sewage line shall be used by the contractor as per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE. (Zone - B.)
M&L for cement concrete 1:3:6 type B-0, using 12.5 mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specified and as directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone agg as in foundations, filling and mass concrete complete all as specified and directed.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level).
M&L Machine pressed precast concrete PU coated colour interlocking paver block any shape and size, with grey cement and pigment confirming to IS 5658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed.
M&L for sand filling under floor or in foundations including watering and consolidation.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
S&F Endura colours paving tiles 300cm X 300cm x 15-20mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6 all as specified and directed.
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed.
M & L for Non skid 600x600x8 to 10mm thick coloured ceramic tiles(joint less) as in floor over hacking surface of existing floor on 15mm thick screed bed in CM 1:6 including pointing in coloured cement to match the shade of tiles including cutting of existing door shutter at required height. complete all as specified directed by Engr-in-Charge.
M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone graded agg) as in louversand jallies 40mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 incl dismantling of same all as per sample shown and directed by engineer-in -charge.
S&F precast RCC coping/post of size 600x100x50 mm suitable for fixing of RCC Jallies in vertically & horizontally including necessary moulds and grooves as required in shape and size complete all as specified and directed.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A-1 (20 mm graded agg) in roof of septic tanks, in slabs supported on walls, cooking plateform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, perapet, shelves and the like complete all as specified and directed. similar items complete all as specified and as directed by Engineer-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
S&F TMT steel bars of 10 mm dia and over,cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed.
Material and labour for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including taking out existing unserviceable overhead tank of any description.
Material and labour for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including taking out existing unserviceable overhead tank of any description.
S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed.
S&F flot valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms complete all as specified and directed.
M & L for cleaning of building service tanks PVC n exc 500 lites capacity situated at various places through machenical tank cleaning process by involving the following five (5) stages of cleaning process shall be carried out as given below :- (a) De-watering PVC tank through was out pipe completely. (b) Total removal of sludges by suction pumps completely. (c) Cleaning of walls, ceiling and floor by high pressure jet of 80-180 bar pressure & inspecting for craks if any completely. (d) Removal of addl sludge by industrial vacuum pump completely. (e) Antibacterial treatment of inside of tank to make it completer bacteria free and completely. Note :- 1. The entire work should be carried out ty TANKCLEAN process by any franceised or M/S TANKCLEAN (Pvt) Ltd or any other MES approved firm having equivalent technology. 2 Entire T & P should be arranged by the contractor at their own. Only electric power & water shall be supplied by MES at stipulated rate.
All as per above item No 54 above but PVC tank capacity exc 500 liters and not exc1000 ltrs.
Dismantling RCC posts or struts (wood steel or RCC) any section embedded in natural ground including taking out embedded portion and making good disturbed ground complete all as specified and directed. Note : Dismantling of existing galvanized iron steel barbed wire / Chain link fencing shall be measured & paid for separately.
Dismantling old Chain link fencing of any description fixed to any type of fencing posts complete all as specified and as directed by Engineer-in-Charge.
Supply only mild steel galvanized chain link fencing 3.15mm dia of mesh wire, mesh size 100x100mm with straining bolts, binding and jointing complete, including necessary drilling, bolting or revetting etc, complete all as specified and as directed. Note:- Flat iron, round bars, nut bolts and washer shall be measured and paid for sepaRately as supply only.
Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire compete all as specified and as directed.
S&F mild steel work as in angle iron in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, and similar works conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Supply only mild steel round bars of 10 mm dia and over conforming to Grade E-165 (Fe 290) for fixing in chain link wire fencing complete all as specified & directed.
Supply only MS flat iron,round or square bars conforming to Grade E-165 (Fe- 290) for fixing chain link fencing, all as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm but not exc 10 cm long and dia of neck 5 to 10 mm, complete all as specified & directed.
Dismantling steel barbed wire of any description fixed to any type of fencing posts complete all as specified and as directed by Engineer-in-Charge.
S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc as directed. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in soft/ loose soil.
Excavation in trenches n.exc 1.5 M wide & n.exc 1.5 M in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and exc 1.5 m but n.exc 3.0m in depth for foundation etc and getting out in soft/loose soil complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick in soil complete all as specified and directed.
Removing excavated material (Soil) to a distance n.exc 50 m and depositing where directed at alevel n.exc 1.5 m above the starting point complete all as specified and directed.
Dismentling asbestos cement corrugated or semi corrugated sheets in roof fixed with L hook or cranked bolt.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded new metal flush box duly make embossed, concealed in walls with for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
One light/Exh fan point controlled by one No one way switch.
One bell/ buzzer point controlled by one bell push.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board.
All as per item No 77 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth all as specified and directed by Engr-in-Charge.
One light/Exh fan point controlled by one No one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6 mm including 3 mm thick laminated top sheet cover including using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps all as specified.
M&L in replacement switch piano 6 amp SP two way, ISI marked.
M&L in replacement socket outlet 6 Amp flush button type all as specified.
M&L in replacement bell push single pole 6 Amps all as specified.
M&L in replacement switch piano flush button type single pole 16 Amps.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
M&L in replacement regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all as specified and directed.
M/L in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
S&F ceiling rose surface PVC 65x50 mm type with three terminals. (For Exhaust Fans).
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 20 A capacity all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Mirror light).
Supply and fix in replacement LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED 35/36 watt and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
Supply and fix in replacement LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base.
Supply and fix in replacement LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
Supply and fix in repair MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
Supply and fix in repair MCB SPN 40 to 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Surface) in walls all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. wire from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
Supply and Fix in repair 40 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
S & F PVC Gang box surface type heavy duty suitable for single 5 Amps switch & socket.
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket.
S&F in replacement 15 amp top plug all as specified & directed
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :-
Sheet 4" x 4" single cutting suitable for one piano switch
Sheet 4" x 4" two cuttings suitable for two piano switches
Sheet 4" x 7" three cuttings suitable for three piano switches
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge.
S & F hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample.
S & F hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample.
Supply & fix in replacement exhaust fan / ventilating fan motor capacity 1/4 HP 230 volts suitable for 200/250/300 mm sweep size exhaust fan complete all as directed.
Supply & fix in replacement HEAVY DUTY exhaust fan motor capacity 1/4 HP 230 volts suitable for 450 mm sweep size exhaust fan complete all as directed.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
Supply only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
S&F heating element of 2/1.5 KW triangular type with nut bolt washer complete all as directed.
M&L for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as directed.
Supply only inner still tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed.
S &F Wall fan 400 mm 3 blade in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site.
Supply and fix in replacement surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engr-in-charge.
Schedule of Credit
M/S Sunil Steel Works
GIAN ENGINEERS
a.k constructions
imran construction company
LAMBA ENTERPRISES
POONAM ENTERPRISES
M/S MSD & Associate
VIJAY KUMAR GUPTA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .