Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance | ₹9.9 L | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹9.9 LRejected-Finance | ₹9.9 L | L2 | Rejected-Finance L2 Bidder |
Tender Value
₹10.0 L
EMD Value
₹99,878
Closing Date
30 Jun 2026, 3:00 pmClosed
Chief Engineer, KNN
Chief Engineer office, KNN, Motijheel
Repairing and painting/whitewashing, Waterproofing of the bathroom, kitchen and the residence Municipal Corporation Quarters No. 111/98, Harsh Nagar, located in the Jal Sansthan Colony under Ward 37, Ashok Nagar Zone 04.
2026_NNKAN_1164689_1
208/AA-4/26-27
Open Tender
Civil Works
45 days
ward-37 ashok nagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹99,878
3 Jul 2026
29 Jun 2026
30 Jun 2026
29 Jun 2026
30 Jun 2026
29 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to 15: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of Junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test."All above operations to be done in order and as directed and specified by the Engineer-in-Charge: (With average thickness of 120 mm and minimum thickness at khurra as 65 mm.) Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to 15: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of Junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test."All above operations to be done in order and as directed and specified by the Engineer-in-Charge:(With average thickness of 120 mm and minimum thickness at khurra as 65 mm) | - | Sqm | 1,180 | - |
| 2 | Dismantling brick work or stone work in lime or cement mortar and Including stacking of materials as directed by Engineer-In-Charge within a distance of 60 meters 1200 feet\. Dismantling brick work or stone work in lime or cement mortar and Including stacking of materials as directed by Engineer-In-Charge within a distance of 60 meters | 1 | Cum | 580 | ₹579.94 |
| 3 | Brick work with common burnt clay (non modular) bricks of class -150 in super structure Cement mortar 1:4 (1 cement: 4 coarse sand) Brick work with common burnt clay (non modular) bricks of class -150 in super structure above plinth level up to floor V level in all shapes and sizes. Cement mortar 1:4 (1 cement: 4 coarse sand) | - | Cum | 7,500 | - |
| 4 | 12mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 12mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. | 1 | Cum | 257 | ₹256.97 |
| 5 | Concrete/R.C.C. Work-RCC work with cement approved coarse sand and 20mm approved stone ballast in proportion for raft foundation with 1:1.5:3 (1 cemnt 1.5 C. sand 20 mm size stone ballast) Reinforced cement concrete work In beams, suspended floors, roofs having slope up to 15• landlngs, balconies, shelves, chaDas, lintels, bands, plaln window sllls, staircases and splral stair cases above pllnth level up to floor five level, excluding the cost of centering, shuttering, finishing andreinforcement. | 0.84 | Rmt | 8,720 | ₹7,324.8 |
| 6 | M.S. or iron in plain work such as hevey size as fabrication of M.S. M.S. or iron in plain work such as hevey size as fabrication of M.S. | 1 | Sqm | 7,200 | ₹7,199.28 |
| 7 | P/F stainless steel kitchen sink kitchen sink with drain board 510x1040mm bowl depth 250mm etc all comp p/f stainless steel kitchen sink kitchen sink with drain board 510x1040mm bowl depth 250mm etc all comp | - | Cum | 4,690 | - |
| 8 | Supply and fixing of anodized aluminium partition having 2mm thick aluminium. Section, partly glazed and partly 12mm thick laminated board. Aluminium board size 83.50x44.65mm as vertical member and 11.40x44.45 as bottom and horizontal member with all fitting, glass panes of 4mm thick handle and locks complete. | - | Cum | 3,530.54 | - |
| 9 | 15 mm nominal outer dla Pipes Providing and flxlng Chlorlnated Polyvinyl Chloride (CPVC) pipes, having thermal stablllty for hot & cold water supply, Including all CPVC plain & brass threaded fittings, Including fixing the pipe with clamps at 1.00 m spacing. This Includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints complete as per direction of Engineer In Charge. Internal work • Exposed on wall | - | Cum | 168 | - |
| 10 | 15 mm nominal bore Providing and fixing C.P. brass bib cock of pproved quality conforming to IS:8931 | - | Cum | 550 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_2184047.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
BOQ_2184047.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid