Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹41.5 L+₹2.0 L (5.12%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹43.8 L+₹4.3 L (11.0%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹45.3 L+₹5.8 L (14.7%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹45.6 L+₹6.1 L (15.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹46.2 L
EMD Value
₹92,340
Closing Date
19 Nov 2022, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
SPECIAL REPAIR FOR REPLACEMENT OF BER SUMMER AND COOLING APPLIANCES UNDER GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
2022_MES_559240_1
GE(U)/PM/D-48/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
DELHI CANTT-10
MES contractor enlisted under class D category c(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹92,340
Yes
9 Dec 2022
21 Oct 2022
21 Nov 2022
21 Oct 2022
19 Nov 2022
5 Nov 2022
Amount
Supply, installation testing and commissioning Desert Cooler powder coated body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG(1 mm thick) PGI Sheet alongwith distribution switch, 5 Amp piano switch and tank of depth 11 inch, electric driven (single phase), 230V, 50 Hz, AC, fitted with submersible pump of suitable capacity, rotary switch (Step type Speed Regulator), three core flexible copper conductor wire of size 1.5 sq. mm of not less than 1.5 metre length with 5 Amp Plug Top, wood wool pad on three sides and three speed Exhaust motor of copper wounded, 450 mm sweep complete all as specified and directed by Engineer-in-Charge. {Make-(Motor & Pump) Khaitan/ Crompton/ Indcool}
Supply, Installation, testing and commissioning of Deep Freezer having hard top double door with locking arrangement, electric driven (single phase, 230 V,50 Hz AC supply), not less than 500 Ltrs with temperature range (-18°C) working with Non CFC refrigerant, energy efficient compressor, puff insulation, heavy duty castor wheels and complete all as specified and directed. (Make-Voltas/Blue Star/LG)
Supply, Installation, testing and commissioning of water cooler fully stainless steel body (Top lid ,front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm), including float ball valve of make prayag/ of suitable sizes as per manufacturer's design & specification with Non CFC Refrigerant (R-134a) ,energy efficient reciprocating compressor of make Emerson/Tecumseh , suitable for operation on single phase 230V, 50 Hz, AC supply, having storage capacity of 80 liters and nominal cooling capacity of 40 liters per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray , Brass (CR plated) push type double faucet , motor and condenser standing base made by stainless steel of minimum thickness 1.0mm , minimum thickness of copper tube of condenser not less than 0.50mm, and minimum one year replacement warranty (Machine & Compressor) complete all as specified and directed. (Make: Model No. SR 40/80 of Sidwal / Model No. SRA 4080G of USHA or equivalent model of BLUE STAR).
Supply, Installation, testing and commissioning of water cooler fully stainless steel body (Top lid ,front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm), including float ball valve of make prayag/ of suitable sizes as per manufacturer's design & specification with Non CFC Refrigerant (R-134a) ,energy efficient reciprocating compressor of make Emerson/Tecumseh , suitable for operation on single phase 230V, 50 Hz, AC supply, having storage capacity of 120 liters and nominal cooling capacity of 60 liters per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray , Brass (CR plated) push type double faucet , motor and condenser standing base made by stainless steel of minimum thickness 1.0mm , minimum thickness of copper tube of condenser not less than 0.50mm, and minimum one year replacement warranty (Machine & Compressor) complete all as specified and directed. (Make: Model No. SR 60/120 of Sidwal / Model No. SRA 60120G of USHA or equivalent model of BLUE STAR).
Supply, Installation, commissioning and testing of Inverter Technology Hot & Cold Split Type wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Capacity not less than 2.0 TR, BEE 3 star rating , fitted with rotary compressor (5 years Warranty), Refrigerant type R-410A/R-32, Rated cooling capacity rated (6450/7033 Watts) including PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 Sqmm for connections with outdoor unit, powder coated brackets/Chowki stand for outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. (Make:- Latest Model of Daikin/O-General/Hitachi) Note:-(i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate. (ii) PVC drain pipes of suitable size & heavy duty copper connection pipes including suitable insulation exceeding 3 Mtrs shall be measured and paid separately under relavent item. (iii) The rates quoted by the contractor shall deemed to include the disconnection of old ACs split type of any capacity from site of installation and transporting to AGE E/M (AC) store yard for depositing in store.
S&F single pole and neutral steel metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amps. complete all as specified and, directed. (Make - Havells/Standard/Legrand).
Supply & fixing heavy duty copper pipe 1/4" dia/bore complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed. (Make: Diamond/ Star/ Raj Ko)
Supply & fixing heavy duty copper pipe 5/8" dia/bore complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed. (Make: Diamond/ Star/ Raj Ko)
Supply and fixing PVC pipe 15 mm bore/dia, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed. (Make: Prince/ Supreme/ Ashirvad/ Prayag)
Material & labour for AC Sub main wiring ISI marked with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (Conforming to IS-694) multi stranded, unsheathed 1100 volts grade in PVC casing Capping (medium grade) of adequate size on surface of wall/ceiling with all fittings & casing capping accessories including one run 6 Sqmm single core unsheathed multi stranded, copper cable FRLS (Conforming to IS-694) as earth continuity wire complete all as specified and directed. Note :-1. Two runs of cable with one run of earth wire and PVC casing capping shall be measured as one unit length. 2. Extra length of cable required for connection of DB shall be deemed to be included in the quoted rate and shall not be measured separately. 3. Earth wire shall run inside the casing capping. 4. Suitable colour code of wire must be ensured for phase/neutral/earth. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing Caping: FINOLEX / PAYAL / KALINGA / PRESTO PLAST).
Supply & fixing powder coated brackets for outdoor unit complete with fixing nuts bolts, washers, driling holes/grouting on wall complete all as specified and directed by Engineer-in Charge
Taking down sub main wiring complete, including sockets etc, and removing taken down materials from site and making good disturbed surfaces of wall, ceiling, floors etc complete all as specified and directed.
HONEY COLLECTION
Saini Enterprises
Singh Associates
J B Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .