Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.5 LAccepted-AOC NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC Quoted lowest and reasonable | |
| 2 | L2₹1.1 Cr+₹41.2 L (62.0%)Rejected-Finance | L2 | Rejected-Finance Quoted high rate | |
| 3 | Rejected-Technical MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND PIN 744301 | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | - | Rejected-Technical Not enlisted in requisite category and Not submitted experience in similar nature work |
| Sl No | Description | Qty | Unit | M/S ISLAND REALCON INDIA PVT. LTD L2 | M/s Sriya Enterprises L1 |
|---|---|---|---|---|---|
| .50SCHEDUEL 'A' PART-I NOTES: Schedule ‘A’ Part I is not prepriced by MES under Ser No. 1.00. The amount indicated as 0.00 under Col-7 signifies this fact only. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only. | |||||
| 1.00 | Designing, Planning and Construction of RCC Lift Shaft for the stretcher cum passenger lift having capacity 1360 Kg / 20 passengers having clear inside 2600x3000mm and of height not less than 10m Including and not limited to the following items:-
1. Machine room/Operator room
2. Hoisting or lifting beam.
3. Basement/pit for buffer.
4. Access to machine room.
5. Rainwater Pipe and its connection upto 1st Manhole.
6. Ducts for power Supply.
Note :-
1. Tenderers are advised to visit the site before quoting their offer.
2. Cost of Soil Investigation and vetting of soil investigation reports by IIT/NITs shall deemed to be included in the quoted rate.
3. Cost of Structural design and vetting of the same by IIT/NITs shall deemed to be included in the quoted rate.
4. Cost of necessary formworks, construction of foundation and finishes required for the construction of the lift shaft shall deemed to be included in the quoted rate.
Contd..../- | 1 | Job | 34,98,224.37 ₹34,98,224.37 | 25,50,000 ₹25,50,000 Lowest |
| 1.01Note (Contd.../-) 5. Cost of water proofing treatment of the lift shaft shall be deemed to be included in the quoted rate. Water proofing to be carried out by OEM applicator & to be got approved by GE before execution 6. Any other items required for meeting the functionality of the lift is deemed to be included in the quoted rate. | |||||
| 1.02Subtotal | |||||
| 1.03GENERAL SUMMARY NOTE: Schedule ‘A’ Part- II to VI are prepriced by MES under Ser No. 2.00 to 6.00. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only. | |||||
| 2.00 | Lumpsum price worked out by the tenderer for "Excavation, Earth work, site clearance and Land Development" as listed in Schedule 'A' Part-II | 1 | Lump sum | 61,864.68 ₹61,864.68 | 30,000 ₹30,000 Lowest |
| 3.00 | Lumpsum price worked out by the tenderer for "Demolition & Dismantling" as listed in Schedule 'A' Part-III | 1 | Lump sum | 2,421.24 ₹2,421.24 | 1,600 ₹1,600 Lowest |
| 4.00 | Lumpsum price worked out by the tenderer for "Path and Covershed" as listed in Schedule ‘A’ Part-IV | 1 | Lump sum | 6,43,354.6 ₹6,43,354.6 | 3,50,000 ₹3,50,000 Lowest |
| 5.00 | Lumpsum price worked out by the tenderer for "Internal Electric Supply" as listed in Schedule ‘A’ Part-V | 1 | Lump sum | 48,191.33 ₹48,191.33 | 21,000 ₹21,000 Lowest |
| 6.00 | Lumpsum price worked out by the tenderer for "External Electric Supply" as listed in Schedule ‘A’ Part-VI | 1 | Lump sum | 4,31,581.2 ₹4,31,581.2 | 1,85,000 ₹1,85,000 Lowest |
Tender Value
₹75.2 L
EMD Value
₹1.4 L
Closing Date
4 Sept 2023, 6:00 pmClosed
Col Arvind Bhakuni, CWE Port blair
Commander Works Engineer, Military Engineer Services, Junglighat PO,Minniebay, Port Blair - 741103
81026 Provn of Stretcher cum passenger lift along with associate structure as special item for Respiratory Isolation ward Bldg P-165 at INHS Dhanvantari, Port Blair
2023_MES_608306_1
81026 Provn of Passenger Lift Dhanvantari - MBay
Open Tender
Civil Works
Lump-sum
270 days
GE Minniebay Port Blair
81026 Provn of Stretcher cum passenger lift along with associate structure as special item for Respiratory Isolation ward Bldg P-165 at INHS Dhanvantari, Port Blair
8 documents required · 8 mandatory
₹1,000
GE Minniebay
₹1.4 L
Yes
20 Jul 2026
7 Jul 2023
11 Sept 2023
7 Jul 2023
4 Sept 2023
21 Aug 2023
7 Jul 2023 - 17 Jul 2023
Amount
SCHEDUEL 'A' PART-I NOTES: Schedule ‘A’ Part I is not prepriced by MES under Ser No. 1.00. The amount indicated as 0.00 under Col-7 signifies this fact only. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.
Designing, Planning and Construction of RCC Lift Shaft for the stretcher cum passenger lift having capacity 1360 Kg / 20 passengers having clear inside 2600x3000mm and of height not less than 10m Including and not limited to the following items:- 1. Machine room/Operator room 2. Hoisting or lifting beam. 3. Basement/pit for buffer. 4. Access to machine room. 5. Rainwater Pipe and its connection upto 1st Manhole. 6. Ducts for power Supply. Note :- 1. Tenderers are advised to visit the site before quoting their offer. 2. Cost of Soil Investigation and vetting of soil investigation reports by IIT/NITs shall deemed to be included in the quoted rate. 3. Cost of Structural design and vetting of the same by IIT/NITs shall deemed to be included in the quoted rate. 4. Cost of necessary formworks, construction of foundation and finishes required for the construction of the lift shaft shall deemed to be included in the quoted rate. Contd..../-
Note (Contd.../-) 5. Cost of water proofing treatment of the lift shaft shall be deemed to be included in the quoted rate. Water proofing to be carried out by OEM applicator & to be got approved by GE before execution 6. Any other items required for meeting the functionality of the lift is deemed to be included in the quoted rate.
Subtotal
GENERAL SUMMARY NOTE: Schedule ‘A’ Part- II to VI are prepriced by MES under Ser No. 2.00 to 6.00. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for "Excavation, Earth work, site clearance and Land Development" as listed in Schedule 'A' Part-II
Lumpsum price worked out by the tenderer for "Demolition & Dismantling" as listed in Schedule 'A' Part-III
Lumpsum price worked out by the tenderer for "Path and Covershed" as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for "Internal Electric Supply" as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for "External Electric Supply" as listed in Schedule ‘A’ Part-VI
Subtotal
NOTE: Schedule ‘A’ Part VII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCHEDULE `A' PART - VII (MISC ITEMS)
PATH AND COVERED SHED
Material and labour for heavy duty chequred cement concrete tiles 300x300x25 mm thick set jointed and pointed in neat cement slurry in floor including 20 mm in CM 1:6 thick complete all as specified and directed.
Supply and fix alunimium flat as wind tie fixed with 50mm / 75mm aluminium self staging screws complete all as specified and as directed by Engineer-in-Charge.
External Electric Supply
Supply and laying of Telerex DWC (Double wall corrugated) HDPE pipe ISI marked of outer dia of 77mm and inner dia 63mm polythylene including coupler and bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed. Make : Rex Polyextrusion Ltd/Tirupathi Plastic Ltd or techno commercially equivalent as approved by GE
Installation of Lift
Design, supply, install, testing and commissioning of stretcher cum passenger lift having capacity 1360 Kg / 20 passengers, Rate speed 0.5 meter per second , 415 volts, 3 phase, AC 50 HZ supply, conforming to IS 14665 , floor designation G+1, number of stops/openings 2/2, access sides inline/Thru type 1(one) in front only, floor display character (Entrance Position) 0(F), 1(F) complete all as specified and as directed with the following specification:-
FINISHES Design Of Lift Cabin : Stainless Steel Lift Cabin Finish : Hairline Finish Car Door : Stainless Steel Car Door Finish : Hairline Finish Ceiling Finish : SS Hairline Finish Ceiling Type : Sleek Small Circular-JLFC 03Ceiling Light : LED lights Fan : Regular (Circular) - Fan Flooring Type : PVC Handrail Type : SS Round Handrail JLHR01 Handrail Location : Rear Side Car Door Sill : Aluminium LANDING DOORS DETAILS Door Type : Centre Opening Sliding Door Door Size (W x H) : 900 x 2000 mm Door Sill : Aluminium Landing Door Finish : 1-2-Stainless Steel (1.5 mm) - Hairline Finish Landing Door Frame/Finish : 1-2-Stainless Steel (1.5 mm) - Hairline Finish Main Landing Floor : 0 Other Landing Floors : 1 Jamb Type : Slim Frame
CABIN OPERATING PANEL Car Operating Panel Type : Car Operating Panel - JLCP01 Number Of Car Operating Panel : 1 COP Faceplate Finish : Stainless Steel - Hairline Finish Button Model : IS4-BAS128(Round) Car Display : Orange Square Dot-Matrix Scrolling Display-Vertical Car Display Location : Car Operating Panel Call Register Signal : Yes Floor Annuciator : Yes LANDING INDICATORS (i) Landing Operating Panel Type : Landing Operating Panel - JLLP01 LOP Location : Landing Display On Wall LOP Mounting Type : Grouting LOP Faceplate Material : Stainless Steel - Hairline Finish Landing Display : 1-2-OSDM-V Landing Display Location : 1-2-LOP Call Register Signal : Yes Stainless Steel Braille Button : Yes
SAFETY DETAILS Over Speed Governor : Yes Door Protection : Infra Red Door Screen Counterweight Screen : Inbuilt Over Load Indicator : Yes Fireman Switch : Yes Automatic Rescue Device : Yes Battery Operated Emergency Alarm Light : Yes Two Way Intercom With Press & Speak in COP : Yes Note : MOU for AMC with OEM during Defects libility period to be provided by the contractor and rate for the same shall be deemed to be included in the quoted rate.
Supply, installation testing and commissioning of LT panel indoor type 2.0 mm thick CRCA sheet steeel enclosure shall have IP55 degree of protection for LT switch gear compartment, Sheet steel member stiffened by angle iron frame work and angle iron standing, suitable Al busbar size for rating 150 amps with SMC busbar supports, dust/vermin proof, epoxy powder coated siemens grey painting, removable undrilled gland plates, each compartment provided with the door fully gasket and pad locking arrangement, anodized aluminium with black background with white engraved letter of name plates, current transformer, internal wirings with FRLSH copper cables including necessary pcc work and making good disturbed surfaces complete wtih following accessories (CPRI Approved)
Incoming MCCB four pole, 18 KA, 63 Amps - 01 No Outgoing MCCB four pole, 18 KA, 50 Amps - 02 No MCB SPN, 10 KA, 6-32 Amps - 03 No LT Busbars Voltage Rating - 433V, Current rating - 150 Amps(R/Y/B/N) Indicating/Metering Digital Multi Function meter -01 No Indication lamps (R, Y, B) LED type -3 No SPD Surge Protection Device, Conforms to IEC 61643-11, Type 1+2, Configuration 3P+N, Protection against direct and indirect lighting surges, Maximum discharge current - Imax up to 50 KA - 01 No
Comprehensive maintenance and repair including renewal/replacement of minor or major defective parts of Lift
Comprehensive maintenance and repair including renewal/replacement of any minor or major defective parts of electrically operated stretcher cum Pasenger lift of capacity 20 Passenger (1360 Kgs) fully automatic electrically operated Gearless with microprocessor based control panel, automatic operated sliding doors serving ground plus upper one floors (G+1) installed at INHs Dhanvantari including carrying out daily check and routine periodical service of fully automatic electric lift with power operated door Duplex collective control system and replacement of unserviceable parts as and when required such as bearing, bushes, all type of shoes, headers, hangers, door cards, door lock, control cards, control connectors/ links, hall push button, hall push button cover, carryout jobs as and when required for rewinding of motors, welding of cracks/ broken MS parts, repair to door, safety edge working at any principle and any type of sensor or mechanical safety lock, magnetic lock or contact, cop buttons, car position indicator, door cill, car door cill, necessary wiring and cable, infrared sensor as per requirement for safe operation of lift, lift cabin fan, cabin light etc, Contd.../-
complete to ensure safety and smooth operation of lift installed at INHS Dhanvantari - 01 No. Period of comprehensive maintenance of Lift will start as Phase- II after completion of liability period of installation of lift. Note : (i) The comprehensive maintenance (Platinum Agreement) shall be done through respective OEM of existing lift. (ii) The contractor will have to submit MOU on stamp paper of Rs 100/- duly notarized as per specified performa given in particular specification from respective OEM of existing lift within twenty eight days from date of receipt of acceptance of tender, failing which the contract will be liable to be cancelled and further action to be taken as per policy in vogue of the contractors default. (iv) The above maintenance include complete maintenance of exisiting lift by regularly and systematically examining adjusting fabricating as and attending complaints within respective time frame as catered in particular specification for smooth and efficient functioning of the equipment/lift. Contd.../-
(v) The contract includes for repair, replacement of spare parts etc as mentioned in Sch 'A' (BOQ). (vi) Contractor will prominently display his contract/mobile number and OEM contact number inside and outside the lift on each lift for call in emergency. (vii) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engineer-in-Charge/GE. (viii) Contractor shall submit safety security certificate of lifts from OEM in every month as per performa given in particular specification and also contractor to ensure serviceablilty of lights and fans in lift and machine room in every month and shall be submitted along with running account receipts and final bill which payment shall not be processed. Contd.../-
(ix) The OEM will also detail one technician staff to inspect the lift every week regarding functioning of lifts or any other issues arising in the lift. The details of technician shall be forwarded for approval before commencement of work. The problem noticed if any to be informed immediately to JE EM/Engr-in-Charge. Incase no technician detailed Rs 500/- per week per lift will be deducted from contractors dues. Technician should always carry service tools during visit in every week. (x) Monthly maintenance check will be carried out by OEM as per monthly maintenance check list mentioned inn particular specification.
Subtotal
M/S ISLAND REALCON INDIA PVT. LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .