Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹45.8 L+₹1.7 L (3.77%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹47.3 L+₹3.1 L (7.10%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹48.7 L+₹4.5 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹53.0 L+₹8.9 L (20.1%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
20 Jul 2021, 6:00 pmClosed
GE (NW) KUNJALI
DR HOMI BHABHA ROAD, NAVY NAGAR, COLABA, MUMBAI - 400 005
8401 REPAIR MAINTENANCE REPLACEMENT OF AC DC SHORE SUPPLY NETWORK INCLUDING SWITCH GEAR AT NAVAL DOCKYARD UNDER GE NW KUNJALI
2021_MES_453492_1
8401/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹99,000
Yes
26 Jul 2021
22 Jun 2021
22 Jul 2021
29 Jun 2021
20 Jul 2021
6 Jul 2021
22 Jun 2021 - 29 Jun 2021
Amount
Supply, fabrication and installation, testing & comnissioning of factory made Feeder piller box for looping of cables, indoor type, dust and vermin proof, made out of 3.15mm CRCA sheet , front & back openable doors having vertical copper bus bar of capacity 2500 Amps for phases and for neutral including powder coated panting, PCC foundation, making spacing for upto 1250 Amps MCCB 3/4 pole, supporting channels, cable termination, cable gland etc. including dismantling old rusted feeder piler box complete all as specified and as dircted. (Note:- MCCBs shall be measured and paid for separately)
Supply, fabrication and installation, testing & comnissioning of factory made Feeder piller box for looping of cables, indoor type, dust and vermin proof, made out of 3.15mm CRCA sheet , front & back openable doors having vertical copper bus bar of capacity 800 Amps for phases and for neutral including powder coated panting, PCC foundation, making spacing for upto 800Amps AC/DC MCCB 3/4 pole, supporting channels, cable termination, cable gland etc. including dismantling old rusted feeder piler box complete all as specified and as dircted. (Note:- MCCBs shall be measured and paid for separately)
S&F in repairs of 0.71mm thick powder coated aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter including suitable size of revits/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed.
S & F MCCB, 415 volts, four pole of capacity 125 Amps, 16 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 16 or equivalent in siemens/GE / C&S
S & F MCCB, 415 volts, four pole of capacity 400 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4220 07 or equivalent in siemens/GE / C&S
S & F MCCB, 415 volts, four pole of capacity 800 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4222 69 or equivalent in siemens/GE / C&S
S & F MCCB, 415 volts, four pole of capacity 1250 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4222 71 or equivalent in siemens/GE / C&S
S & F MCCB, 415 volts, four pole of capacity 1000 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4222 70 or equivalent in siemens/GE / C&S
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make: Legrand cat No 4085 87-95 or equivalent Cat part in Seimens/C&S.
S&F MCB SPN 40-63Amps, 10KA 'C' Curve 240V complete all as specified and directed. Make: Legrand cat No 4086 18-20 or equivalent Cat part in Seimens/C&S.
S & F in replacement 20 Amps Single pole and neutral enclosure with a Two Pin and earth plug and socket complete with one single pole MCB and making connections complete all as directed. Make -Legrand Cat Part No. 5078 14 or equivalent in Siemens /GE/ C&S
Supply and fixing in repair walll/surface mounted 10W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed. Make : CG/wipro/C&S cat No LTTB2F10WLEDW BATTEN/Bajaj/Havells/Philips
Supply and fixing in repair walll/surface mounted 20W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed. Make : CG/wipro/C&S cat No LTTB4F20WLEDEW BATTEN/Bajaj/Havells/Philips
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 41 or equivalent Cat part in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 8 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for MCCB as incomer DP MCB/ Isolator/RCCB/RCBO as sub incomers and SP MCB's as outgoing etc. complete all as directed. Make - Legrand cat No 5077 52 or equivalent in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 12 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing etc complete all as directed. Make - Legrand cat No 5077 53 or equivalent in Siemens/GE NOTE FOR ITEM No. 13 to 29 : MCB DBs shall be concealed in wall where ever posible including cost of removing old wooden box making good the surface to match with surrounding deemed to be included in quoted rates
M&L for fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with SCOTCHCAST jointing material heat and accessories suitable for XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm 3½ Core including disconnecting & taking down old damaged cable complete all as specified and directed. Make: Rychem/3M or equivalent as approved by GE
M&L for fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with SCOTCHCAST jointing material heat and accessories suitable for XLPE armoured aluminium conductor cable of size 240 to 400 Sq mm 3½ Core including disconnecting & taking down old damaged cable complete all as specified and directed. Make: Rychem/3M or equivalent as approved by GE
M&L for fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with SCOTCHCAST jointing material heat and accessories suitable for XLPE armoured aluminium conductor cable of size 95 to 120 Sq mm 3½ Core including disconnecting & taking down old damaged cable complete all as specified and directed. Make: Rychem/3M or equivalent as approved by GE
Supply and laying Single Core cable of size 240 sq mm (heavy duty), 1100 Volts grade, as IS 694:1990, unsheathed, PVC Insulated and Multi Core PVC Insulated and PVC sheathed industrial cables with flexible bright annealed Coppper Conductor, including making connection and taking out old damaged cable complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and laying Four Core cable of size 70 sq mm (heavy duty), 1100 Volts grade, as IS 694:1990, unsheathed, PVC Insulated and Multi Core PVC Insulated and PVC sheathed industrial cables with flexible bright annealed Coppper Conductor, including making connection and taking out old damaged cable complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240sq mm 3½ core laid in duct / along pole/wall etc including making connection complete all as directed. Make: Polycab/ Havells/ Finolex / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185sq mm 3½ core laid in duct / along pole/wall etc including making connection complete all as directed. Make: Polycab/ Havells/ Finolex / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in Hard / dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. Note: 10% shall be deducted from the total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed.
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness shall be measured and paid)
Supply and laying unreinforced Precast Cement Concrete Cable Covers, class LV, Type-1, Flat, size 250mm X 150mm X 40mm made out of M-20 grade PCC as per IS-5820: 1970, in trenches for cable protection, embossed with " ELECTRIC" on the top surface complete all as specified and as dircted.
Supply, laying and fixing 100mm bore GI light grade pipe for necessary road crossing, culverts etc for cable protetcion all as specified and as directed.
M & L for 25x4mm Galvanised iron strip earth continuity conductor or main earthing lead fixed to wall with clamps or buried in ground or drawn in conduits / pipe and fixed to pole, panel/transformer or any other indicated situation for loop earthing etc. as required complete all as specified and as dircted.
Supply of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron (average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied alongwith weatherproof chamber as directed. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
TETRI ENTERPRISES
DHARMESH ENTERPRISES
ELECTRO ASSOCIATES
Rohit Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .