| 1 | L1₹33.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.8 L+₹1.8 L (5.45%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹36.5 L+₹2.5 L (7.48%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹38.7 L+₹4.8 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹39.5 L+₹5.6 L (16.4%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Saurabh Gupta, EE
GE (W) Colaba, Mumbai
REPAIR/ REPLACEMENT OF UG CABLES AND LT SWITCH GEARS AND CONNECTED ITEMS UNDER GE (WEST) COLABA, MUMBAI
2024_MES_643514_1
8818/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹80,000
Yes
21 Mar 2024
21 Feb 2024
20 Mar 2024
21 Feb 2024
18 Mar 2024
5 Mar 2024
Amount
Excavation in trenches, nexc1.5 m wide and nexc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
All as per sl. item No.01 above but in hard/dense soil.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth and getting out in hard rock/road cutting/RCC/PCC all as specified and directed.
Supply and providing crushed stone sand for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thickness will be measured.
Returning, filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm all as specified and directed.
Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point in soft /loose soil all as specified and directed.
Removing of excavated rock of material from the site of work and transporting out of MD land all as specified and directed.
Supply and providing unreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) of sizes Class LV type I, flat size 250x150x40 mm putting adjecent to each all as specified and directed.
Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 90mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
Supply and laying in repairs tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as specified and directed.
Supply and laying in repairs tubes light grade, galvanized, 80 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as specified and directed.
M&L required for disconnecting all connections and shifting of LT feeder panel from one location to another location as directed and installing, connecting all LT cables including earthing connections and testing all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) for foundatuion/road filling and mass concrete all as specified and directed.
Supplying, laying, commissioning & testing LT underground cables 240 Sqmm X 3.5 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required on ground including taking down for old unserviceable cable of following sizes .
All as per item No 15 above but 185 Sqmm X 3.5 Core
All as per item No 15 above but 150 Sqmm X 3.5 Core
All as per item No 15 above but 120 Sqmm X 3.5 Core
All as per item No 15 above but 95 Sqmm X 3.5 Core
M&L for cable fault detection at various locations by all T & P, equipments for LT CABLE XLPE aluminium conductor including testing and commissioning all as specified and directed
M&L for cable jointing kit, in repairs for LT CABLE XLPE aluminium conductor including testing and commissioning complete for the size of 35sqmm X 3.5 Core all as specified and directed
All as per item No 21 above but of size 50sqmm X 3.5 Core all as specified and directed
All as per item No 21 above but of size 70sqmm X 3.5 Core all as specified and directed
All as per item No 21 above but of size 95sqmm X 3.5 Core all as specified and directed
All as per item No 21 above but of size 120sqmm X 3.5 Core all as specified and directed
All as per item No 21 above but of size 185 sqmm X 3.5 Core all as specified and directed
All as per item No 21 above but of size 240sqmm X 3.5 Core all as specified and directed
All as per item No 21 above but of size 300sqmm X 3.5 Core all as specified and directed
Dismantling of damaged/Burnt MCCB and Supply & fixing of HRC FUSE, 4 Pole, 320 Amps, 35/36kA, 415Volts, 50Hz AC s with enclosure of 3.15 mm thick for Outdoor S/S fixing on wall/feeder panel for inter connection of panel all as specified and directed by Engr-in-charge. MAKE: As per existing
M&L in repairs for earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the earth plate not less than 1.50 mtr below normal ground level and connected to GI earth lead strip 25 x 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC (1:3:6, C1), Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe "medium grade" for watering and 40 mm dia for protection pipe with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil all as specified and as directed and testing on completion.
S&F in repairs earth continuty conductor fixed to wall/surface or recess or burried in ground or any situation for loop earthing by 25 X 4 mm GI strip all as specified and directed by Engineer-in-Charge.
shree arihant constrution
SHRI SAI ENTERPRISES
N.S.ENTERPRISES
Om Sai Enterprises
GANGAJAL
S S ENTERPRISES
Bidder Name
S S ENTERPRISES
SHRI SAI ENTERPRISES
NOEL ENGINEERS
shree arihant constrution
Om Sai Enterprises
GANGAJAL
N.S.ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .