| 1.00 | Supply of new numerical Over current/earth fault relay (in 33KV Feeder C&R panel)
ALSTOM/SIEMENS/ABB/GE/Schneider make suitable for various C&R panel with following features-
(a) 6 Binary Input, 6Binary Output, with 2 alarm Output
(b) Aux. Supply 110V DC
(c) Having Aux current 1A, and Voltage-110V..
(d) Having non directional inst.E/F & O/C instant and also time delayed O/C & E/F Features.
(e) Communication interface RS-485 | 2 | No | 41,000 ₹82,000 Lowest | 50,000 ₹1,00,000 |
| 2.00 | Work of replacement & retrofitting of old defective relays by new relays, by cutting the MS sheet of relay's size and mounting it with proper drilling and tightening with nut bolts and painting the used ms sheet with same colour as panel and dismantling old defected relays. (Consumable provide by contractor) | 2 | No | 1,950 ₹3,900 Lowest | 5,000 ₹10,000 |
| 3.00 | Rewiring in Relay panel with proper dressing, ferruling and terminations in C&R panel. Work should be done by skilled engineer's guidance. (Consumable provide by contractor) | 2 | No | 1,950 ₹3,900 Lowest | 5,000 ₹10,000 |
| 4.00 | Work for commissioning, and testing of new installed Relays and all required tests should be done related to relays as per guidance of T&C team. Testing kit will be Provided by department & Testing should be done by skilled engineer | 2 | No | 1,950 ₹3,900 Lowest | 5,000 ₹10,000 |
| 5.00 | Master Trip relay suitable for auxillary voltage 110V DC of ABB Make. | 2 | No | 19,500 ₹39,000 Lowest | 25,000 ₹50,000 |
| 6.00 | HRC Fuse of 10 Amp Capacity of L&T make | 100 | No | 135 ₹13,500 Lowest | 250 ₹25,000 |
| 7.00 | HRC Fuse of 04 Amp Capacity of L&T make. | 100 | No | 125 ₹12,500 Lowest | 250 ₹25,000 |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
12 Mar 2026, 4:00 pmClosed
EXECUTIVE ENGINEER
132 KV SUB STATION NAUGARH
RETROFITTING OF 33 KV NUMERICAL RELAY OF 33 KV COURT FEEDER AT 132 KV S/S NAUGARH
2026_UPTCL_1114286_1
E-tender no.42 2025-26
Open Tender
Electrical Works
Lump-sum
30 days
132 KV SUB STATION NAUGARH
AS PER TENDER
2 documents required · 2 mandatory
₹590
ELECTRICITY TRANSMISSION DIVISION II BASTI
₹2,000
18 May 2026
10 Feb 2026
13 Mar 2026
10 Feb 2026
12 Mar 2026
10 Feb 2026
Supply of new numerical Over current/earth fault relay (in 33KV Feeder C&R panel) ALSTOM/SIEMENS/ABB/GE/Schneider make suitable for various C&R panel with following features- (a) 6 Binary Input, 6Binary Output, with 2 alarm Output (b) Aux. Supply 110V DC (c) Having Aux current 1A, and Voltage-110V.. (d) Having non directional inst.E/F & O/C instant and also time delayed O/C & E/F Features. (e) Communication interface RS-485
Work of replacement & retrofitting of old defective relays by new relays, by cutting the MS sheet of relay's size and mounting it with proper drilling and tightening with nut bolts and painting the used ms sheet with same colour as panel and dismantling old defected relays. (Consumable provide by contractor)
Rewiring in Relay panel with proper dressing, ferruling and terminations in C&R panel. Work should be done by skilled engineer's guidance. (Consumable provide by contractor)
Work for commissioning, and testing of new installed Relays and all required tests should be done related to relays as per guidance of T&C team. Testing kit will be Provided by department & Testing should be done by skilled engineer
Master Trip relay suitable for auxillary voltage 110V DC of ABB Make.
HRC Fuse of 10 Amp Capacity of L&T make
HRC Fuse of 04 Amp Capacity of L&T make.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_2066126.xls
BOQ • 0.26 MB
TECHNICALDOC42.pdf
Tender Documents • 5.39 MB
Corrigendum0042.pdf
PDF • 0.28 MB
Corrigendum042.pdf
PDF • 0.29 MB
Corrigendum42.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .