Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹1.2 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.3 Cr+₹2.9 L (2.32%)Rejected-Finance A T ROAD EVERLITE HOUSE PANITOLA LAIPULI TINSUKIA ASSAM 786183 | TINSUKIA | ASSAM | 786183 | ₹1.3 Cr+₹2.9 L (2.32%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹1.3 Cr+₹4.3 L (3.43%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | ₹1.3 Cr+₹4.3 L (3.43%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹1.3 Cr+₹6.0 L (4.80%)Rejected-Finance | ₹1.3 Cr+₹6.0 L (4.80%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹1.3 Cr+₹9.3 L (7.50%)Rejected-Finance | ₹1.3 Cr+₹9.3 L (7.50%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
23 Jul 2022, 6:00 pmClosed
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
CONVERSION OF LT OH CONDUCTORS INTO UG LT CONDUCTOR AND ALLIED INFRA AT BHALUKMARA IN JORHAT MIL STN UNDER GE JORHAT
2022_MES_530398_1
84098E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE JORHAT
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE JORHAT
₹2.1 L
Yes
17 Sept 2022
13 Jun 2022
25 Jul 2022
13 Jun 2022
23 Jul 2022
6 Jul 2022
13 Jun 2022 - 25 Jun 2022
Amount
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 240 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 185 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 150 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 100 mm including all fittings and fixtures in trenches complete all as specified and as directed.
Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 75 mm including all fittings and fixtures in trenches complete all as specified and as directed.
Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 50 mm including all fittings and fixtures in trenches complete all as specified and as directed.
Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 40 mm including all fittings and fixtures in trenches complete all as specified and as directed.
M & L for making hole by suitable means for insertion of GI pipe 50 mm bore for passing cable across the road without cutting the road complete all as directed.
M & L for making hole by suitable means for insertion of GI pipe 80mm/100mm bore for passing cable across the road without cutting the road complete all as directed.
Material and Labour, fabrication, testing and commissioning of outdoor LT bus bar Panel sheet metal enclosure made out of 3.15 mm thick CRCA Sheet of approx size 500x400x300mm, IP 54 incorporated with bus bar chamber having bus bar capacity 200 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator,including provision for MCCB 63 amp 4 Pole- 01 Nos,18 ka ,415 volt (Incomer) duly prewired with appropriate size of aluminium bus bar thimbled (for accomodating Outgoing Cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation duly painted with powder coated paint, dust proof, vermin proof having single door with 2 Nos hinges with locking arrangement, inlet and outlet cable provisions incorporated with LED indicators R, Y, B-01 Set, and fixed on ground with MS angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC (1:2:4) using 20 mm graded stone aggregate complete all as specified and directed. Make: Any CPRI Approved or as given in Appx B to PS
Material and Labour, fabrication, testing and commissioning of outdoor LT bus bar Panel sheet metal enclosure made out of 3.15 mm thick CRCA Sheet of approx size 500x400x300mm, IP 54 incorporated with bus bar chamber having bus bar capacity 200 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator,including provision for MCCB 100 amp 4 Pole- 01Nos,30 ka ,415 volt (Incomer) duly prewired with appropriate size of aluminium bus bar thimbled ( for accomodating Outgoing Cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation duly painted with powder coated paint, dust proof, vermin proof having single door with 2 Nos hinges with locking arrangement, inlet and outlet cable provisions incorporated with LED indicators R, Y, B-01 Set, and fixed on ground with MS angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC using 20 mm graded stone aggregate complete all as specified and directed. Make: Any CPRI Approved or as given in Appx B to PS
Material and Labour, fabrication, testing and commissioning of outdoor LT bus bar Panel sheet metal enclosure made out of 3.15 mm thick CRCA Sheet of approx size 600x500x300mm, IP 54 incorporated with bus bar chamber having bus bar capacity 200 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator,including provision for MCCB 160 amp 4 Pole- 01Nos,25 ka ,415 volt (Incomer) duly prewired with appropriate size of aluminium bus bar thimbled ( for accomodating Outgoing Cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation duly painted with powder coated paint, dust proof, vermin proof having single door with 2 Nos hinges with locking arrangement, inlet and outlet cable provisions incorporated with LED indicators R, Y, B-01 Set, and fixed on ground with MS angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC using 20 mm graded stone aggregate complete all as specified and directed. Make: Any CPRI Approved or as given in Appx B to PS
Material and Labour, fabrication, testing and commissioning of outdoor LT bus bar Panel sheet metal enclosure made out of 3.15 mm thick CRCA Sheet of approx size 600x500x300mm, IP 54 incorporated with bus bar chamber having bus bar capacity 200 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator,including provision for MCCB 200 amp 4 Pole- 01Nos,36 ka ,415 volt (Incomer) duly prewired with appropriate size of aluminium bus bar thimbled ( for accomodating Outgoing Cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation duly painted with powder coated paint, dust proof, vermin proof having single door with 2 Nos hinges with locking arrangement, inlet and outlet cable provisions incorporated with LED indicators R, Y, B-01 Set, and fixed on ground with MS angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC using 20 mm graded stone aggregate complete all as specified and directed. Make: Any CPRI Approved or as given in Appx B to PS
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through outdoor type joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm, Outdoor type complete all as specified and directed
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through outdoor type joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm, Outdoor type complete all as specified and directed
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through outdoor type joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 to 150 sqmm, Outdoor type complete all as specified and directed
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply and fix Thermoplastic cable junction box for street lights of size 155 x 210 x 92 mm made of high quality polycarbonate IP-66 (Weather Proof), incl terminals, shock proof, rust free, corrosion free, chemical resistant, fire retardant having high impact (IK 08) totally insulated, UV resistant having high grade gasket made of polyurethane with including MCB DP 6 Amps and 2 Nos M32 size cable gland suitable up to, 25 Sqmm cable etc complete all as specified and directed
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
Supply and Fix, LED roadway luminaire, 60 Watts, with pressure die-cast aluminium housing, IP-66, high power LEDs as light source and electronic driver and 10 KV SPD and fixed on pole with 40 mm dia light grade GI pipe (bend to shape) bracket complete with MS flat iron clamp, nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. Make Crompton Cat Part No. RAPTOR NEO -I or equivalent Make as given in Appx B
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Dismantling ACSR or AAC conductors from LT OH lines/structures and removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside by diconnecting all electrical connections for re-use or removing to store or for schedule of credit all as directed by Engr-in-Charge
Dismantling LT insulators any type, any size by diconnecting all electrical connections complete all as specified and as directed.
Dismantling steel poles/ struts, any size, setting aside for reuse within 50 metres or transfer to store for sch of credit complete all as specified and as directed.
Dismantling concrete poles/ struts, any size, setting aside for reuse within 50 metres or transfer to store for sch of credit complete all as specified and as directed.
M & L for painting on steel tubular swaged pole with two coats of synthetic enamel and writing pole No. on poles over a coat of primer on exposed portion including painting on cross arms, street light brackets complete all as specified and as directed.
S&F in repairs, PVC insulated and sheathed, multi standard aluminium conductor cable 2.5 Sqmm Weather proof flat twin core cable to connect from junction to light etc complete all as specified and as directed
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply and fix Astronomical time switches 415 V three Phase of 32 Amp rating with contactor fitted inside steel enclosure and all necessary connections complete all as specified and as directed. Make Havells Cat No. IHXTS0306A or equivalent Make as given in Appx B
Taking Down Unserviceable Junction Box of any size complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and as directed.
EVERLITE ENGINEERING INDUSTRIES
RADHA ENTERPRISE
M/s O DARANG ENTERPRISES
KAY CEE CO. INDIA
M/S PAUL CONSTRUCTION
PURBANCHAL BUILDERS
M/S DB TRADING CO
HEMONTA DAS
Garg Brothers
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .