Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.3 L+₹26,460 (0.73%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.7 L+₹73,050 (2.03%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.0 L+₹2.0 L (5.50%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹43.3 L+₹7.3 L (20.2%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Satwari
GE Satwari Jammu
REPAIR/MAINT OF ELECTRIC SUPPLY CABLES AND ALLIED WORKS AT RIDGE AREA ROULKI Y STATION AND OTHER AREAS UNDER AGE E/M OF GE SATWARI
2023_MES_612936_1
GEJM-43/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE Satwari
D Class Cat b i
9 documents required · 9 mandatory
₹500
GE Satwari
₹90,000
Yes
13 Nov 2023
12 Aug 2023
13 Sept 2023
12 Aug 2023
11 Sept 2023
28 Aug 2023
Amount
Relaying of healthy cable of any size retrived from srl item no 1 above after repair, making proper jointing and making connection using thimbles/lugs of suitable size as required at site all as directed and specified.
Taking out GI protection pipe from the pole /passsing through road/existing treanches for reuse at site or for taking credit of pipe to be replaced with new one all as directed and specified.
Relaying of GI pipe for cable protection intrenches/road/pole all as specified and dirrected.
Relaying full bricks retrieved from srl item no 2 above for cable protection all as specified and directed.
Taking out serviceable/unserviceable LT cable aluminum conductor of any size 2/3/4 core from excavated trench/pole/over ground etc and retreived material to store kept in safe custody for reuse at site or for taking credit of cable to be replaced with new one all as specified and dirrected. Excavation, sand and return filling will be paid saperately.
Excavation in trenches not exceeding 1.5m in width and not exceeding 1.5m in depth and getting out in any type of soil all as directed and specified.
Supply and spreading dry river sand in trenches for cushioning of cable 8 cm layer before laying the cable and 15cm thick layer after laying the cable. Note-Sand layer shall be paid for 18mm only after well pressed all as directed and specified.
Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sub class 'B' bricks all as directed and specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, all as directed and specified.
Removal of excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour in replacement of double compression brass cable gland suitable for LT cable of size 25 to 95 sqmm 4 core all as directed and specified.
Material and labour in replacement of double compression brass cable gland suitable for LT cable of size 95 to 300 sqmm 4 core all as directed and specified.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes:- (a) 6 Sqmm x 2 core.
(b) 10 Sqmm x 2 core.
(c) 16 Sqmm x 2 core
(d) 25 Sqmm x 3.5 core
(e) 35 Sqmm x 3.5 core
(f) 50 Sqmm x 3.5 core
(g) 70 Sqmm x 3.5 core
(h) 95 Sqmm x 3.5 core
(j) 120 Sqmm x 3.5 core
(k) 185 Sqmm x 3.5 core
(l) 240 Sqmm x 3.5 core
Taking down of unserviceable of over head aluminium conductor off size any type all as directed
Supply & fixing including taking out 1100 volt grade heavy duty cable PVC insulated aluminium conductor as in service connections suspended by insulated hangers not more than 1.0 mtr apart including 4mm dia GI wire, suspension wire, 2 core flat or circular of following sizes:- (a) 6 Sqmm x 2 core
(b) 10 Sqmm x 2 core
(c) 16 Sqmm x 2 core
Supply and fixing aluminium lugs of size 120 to185 Sqmm.
Supply and fixing aluminium lugs of size 185 to240 Sqmm.
Supply and fixing aluminium lugs of size 240 to 300 Sqmm
Supply and fixing aluminium lugs of size 400 to 630 Sqmm
M&L for cable jointing kit Straight through Indoor/outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cables of size 10 to 16 Sqmm 4/3.5 core cables all as directed and specified.
Ditto all as per 32.00 but suitable for 25 Sqmm and upto 35 Sqmm x 4/3.5 core
Ditto all as per 32.00 but suitable for 50 Sqmm x 3.5 core
Ditto all as per 32.00 but suitable for 95 Sqmm x 3.5 core
Ditto all as per 32.00 but suitable for 120 Sqmm and upto 185 Sqmm 3.5 core
Ditto all as per 32.00 but suitable for 240 sq mm x 3.5 core
Supply laying & testing XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (E) grade of size 120 Sqmm x 3 core, all as directed and specified.
M&L in replacement of HTcable straight through type jointing kit, outdoor, heat shrinkable including all jointing material & accessories suitable for 11000 Volt grade aluminium conductor cables of size 120 Sqmm 4/3.5 core cables.
Supply and fixing in replacement of GI steel tubing light grade complete under Road, Path drain, fixed on walls etc of size 100mm bore.
Ditto all as per 40.00 but size 80mm bore
Ditto all as per 40.00 but size 40mm bore
Supply and Fixing thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65( weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands (IP-65) and/or grommets (IP-55). Size of enclosure: ( 250 x 180 x 110 ) mm With suitable connecters for /1Ph loop in loop out and branch out vibration proof connections and fixing on PCC/ steel poles with 25x3mm thick 02 Nos of clamp with nuts and bolts and washers and proper thimbling all as directed and specified.
M & L for GI Strip earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less that 1.5M below normal grouond level connected to GI Strip 25 x 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe with and funnel, PCC 1:3:6 Type C-1 chamber with 40 mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
M & L for GI Strip earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less that 1.5M below normal grouond level connected to GI Strip 32 x 6 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe with and funnel, PCC 1:3:6 Type C-1 chamber with 40 mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
Material and labour for removed the damage part and jointing kit with cable end termination joint kit incomming and outgoing cable of size of 16 sq mm 4 core alongwith cable gland & plate incld nuts/bolt/washers as per existing size complete all as specified and directed.
All as per ser No 46 here in before but of 25 sq mm 4 core all as directed
All as per ser No 46 here in before but of 35 sq mm 3.5core all as directed
All as per ser No 46 here in before but of 50 sq mm 3.5 core all as directed
All as per ser No 46 here in before but of 70 sq mm 3.5 core all as directed
All as per ser No 46 here in before but of 95 sq mm 3.5 core all as directed
All as per ser No 46 here in before but of 150 sq mm 3.5 core all as directed
All as per ser No 46 here in before but of 185 sq mm 3.5 core all as directed
All as per ser No 46 here in before but of 240 sq mm 3.5 core all as directed
BMMJ TRADERS AND ENGINEERS
LAL CONSTRUCTIONS
Warne Builders
SATISH AND CO
M/S S K Electricals Regd
vivek and co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .