Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance A BLOCK FLAT NO 301 SPECTRA METRO HEIGHTS NAGOLE HYDERABAD RANGA REDDY TELANGANA 500 068 | HYDERABAD | RANGA REDDY | TELANGANA | 500068 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
23 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
PROVN OF SEPTIC TANK 750 USERS WITH SEWAGE LINE AT ARTY CENTER AND 450 USERS WITH SOAKAGE WELL NEAR BLDG E25 AND E54 AT 7 MILE AREA OF 3 DOGRA UNDER GE GOLCONDA
2022_MES_553759_2
8626/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
As Per Tender
8 documents required · 8 mandatory
₹500
GE GOLCONDA
₹98,000
Yes
27 Jan 2023
4 Jan 2023
25 Jan 2023
4 Jan 2023
23 Jan 2023
9 Jan 2023
Amount
Surface excavation n.exc 30cm deep, averaging 15cm deep and getting out hard / dense soil.
Excavation over areas, n exc 1.5m deep and getting out in hard /dense soil complete all as specified and directed.
Excavation over areas, exc 1.5M but n. exc 3.0 M depth and getting out in soft/ loose soil complete all as specified and directed.
Excavation over areas, exc 3.0M but n. exc 4.5 M deep and getting out in hard/ dense soil complete all as specified and directed.
Excavation over areas,exc 4.5M but n. exc 6.0 M deep and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation etc or shafts, wells cesspits manholes pier holes etc n. exc 10 sqm on plan in hard/ dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but n exceeding 3.0m deep for foundation etc or shafts, wells cesspits manholes pier holes etc n. exc 10 sqm on plan in hard/ dense soil complete all as specified and directed.
M&L 25mm thick PCC 1:2:4 type Bo as in floor to septic tank finished even and smooth without using extra cement complete all as specified and directed.
M & L PCC 1:4:8 type D2 in foundations, filling and mass concrete etc complete all as specified and directed.
M & L for solid block masonry grade C5, straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and directed.
M & L for solid block masonry grade C4, straight or curved on plan exceeding 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and dirceted.
M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregated) as in benching of manholes including necessary form work complete all as specified and directed.
M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregated) as in copping including necessary form work complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate as in Pre-cast cover slabs for mahnoles including necessary from work set in CM 1;4 complete all as specified and directed. (Reincorcement shall be measured & paid separately)
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate as in lintel bands, roof beams and cantilevers complete all as specified and directed.
Use & waste of Formwork for rough finished concrete flat surface to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and dirceted.
Use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10 cm wide complete all as specified and dirceted.
Use and waste of form work to sides and soffits of floor or roof beams, lintels, cantlevers, shelves incl supports etc for rough finished surface of concrete.
M&L for 15 MM thick rendering in CM 1:4 mixed with water proofing compound on fair face of walls, surface finished even & smooth without using extra cement complete all as specified and directed (water proofing compound will be measured and paid seperately) .
Supply only Integral water proofing compound
M&L for 15 MM thick rendering in CM 1:4 on fair face of brick walls or concrete surface, surface finished even & smooth without using extra cement complete all as specified and directed.
Supply only Broken brick coarse aggregate/bats gauge 63 to 150mm in soakage well etc complete all as specified and directed..
S&F Framed work such as rungs, grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; railings; and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 5 mm dia and over upto and including 10mm dia as in spacers, stirrups and binders cut to length, bent to shape required and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F for rungs, bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, hains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
M&L 110mm dia PVC (SWR) single socketed waste and vent pipe in any length, with rubber ring joints, fixed to walls complete all as specifide and directed.
S&F of PVC (SWR) vent cowl of bore 110mm complete all as specifide and directed.
S & F 110 mm bore PVC (SWR) pipe single socketed,in any length with rubber ring joints, laid in trenches or in floors complete all as specifide and directed.
M&L for salt glazed stoneware drain pipes 150mm dia bore (Grade 'A' pipe) laid in trenches and jointed as specified complete all as specified and directed.
M & L PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm drain pipes complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points etc complete all as specified and directed.
M&L preparation of new or previously untreated steel surfaces of any description, not exceeding 10cm width or girth, not otherwise described and applying two coats of synthetic enamle paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M/S Veerabhadra Constructions
STANDARD AGENCIES
NAVANAND ENTERPRISES
MCS ENGINEERING CONSTRUCTIONS
SM CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .