The Executive Engineer (E) BSNL ED Mumbai
The Executive Engineer E BSNL Electrical Division 5th Floor A Wing BSNL Admin Bldg Juhu Tara Road Santacruz West Mumbai 400054
Replacement of condenser coil of 7 TR HPAC Ms Emerson make units at MUX Prabhadevi and NIB Fountain Mumbai. (SH Replacement of condenser coil of 8 nos 7 TR HPAC
2022_BSNL_115145_1
NIT No. 02/EEE/BSNL/ED/MI/2022-23
Open Tender
Electrical Works
Item Rate
30 days
Mumbai
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO (F and A) BSNL
₹18,880
6 Jun 2022
7 May 2022
31 May 2022
7 May 2022
30 May 2022
7 May 2022
90 days
Amount
SH I ( MUX PRABHADEVI)
Supplying of condenser coil of 7 TR M/s Emerson make HPAC at TE Prabhadevi Mumbai ( 11 th floor ) complete with transportation , loading & unloading by hiring requsite manpower ,tools & plant etc as required ( The following shall be specification of condenser coil. The vendor /supplier may visit the site for actual specification of condenser coil.) i) Overall dimension 1700 (W) x1200 (H) ii) The copper tubes shall be of seamless hard drawn copper pipe inner groove & wall thickness 0.28 mm with 3 rows and heder made out of 18 gauge copper pipe, fins thickness of 38 SWG (0.15 mm )
Dismantling of existing deteriorated condenser coil of 7 TR M/s Emerson make HPAC complete with pump down the refrigerant circuit by hiring gas recovery pump at site and storing R 407 gas in System / Gas cylinder , cutting of condenser coil /copper refrigerant pipe by hiring requsite manpower ,tools & plant etc as required ( Note :- The agency shall take all possible efforts for recovery of R-407 gas to the maximum extent for reutilisation of gas .)
Installation of condeser coil in existing condenser unit including brazing of refrigerant piping connection complete with leak testing of system by filling nitrogen pressure for 24 hours , vacuumizing the system & charging the same with existing refrigerant, trial cum performance run test for 24 hours duration complete with testing and commissioning of HPAC package unit as per BSNL specification etc as required
Providing anti-corrosion nano coating (ULTRACORR ACX) for HPAC coils and condensers for providing a long-lasting corrosion protection of copper and aluminium condenser coils, preventing leakage of gas due to atmospheric and salty /chemical corrosion, complete etc as required
Supplying and Charging of Refrigerant Gas ( R-407 ) for charging in the existing AC Package unit i/c testing and commissioning etc as reqd.
SH II( NIB FOUNTAIN )
Supplying of condenser coil of 7 TR M/s Emerson make HPAC at TE Prabhadevi Mumbai ( 11 th floor ) complete with transportation , loading & unloading by hiring requsite manpower ,tools & plant etc as required ( The following shall be specification of condenser coil. The vendor /supplier may visit the site for actual specification of condenser coil.) i) Overall dimension 1700 (W) x1200 (H) ii) The copper tubes shall be of seamless hard drawn copper pipe inner groove & wall thickness 0.28 mm with 3 rows and heder made out of 18 gauge copper pipe, fins thickness of 38 SWG (0.15 mm )
Dismantling of existing deteriorated condenser coil of 7 TR M/s Emerson make HPAC complete with pump down the refrigerant circuit by hiring gas recovery pump at site and storing R 407 gas in System / Gas cylinder , cutting of condenser coil /copper refrigerant pipe by hiring requsite manpower ,tools & plant etc as required ( Note :- The agency shall take all possible efforts for recovery of R-407 gas to the maximum extent for reutilisation of gas .)
Installation of condeser coil in existing condenser unit including brazing of refrigerant piping connection complete with leak testing of system by filling nitrogen pressure for 24 hours , vacuumizing the system & charging the same with existing refrigerant, trial cum performance run test for 24 hours duration complete with testing and commissioning of HPAC package unit as per BSNL specification etc as required
Providing anti-corrosion nano coating (ULTRACORR ACX) for HPAC coils and condensers for providing a long-lasting corrosion protection of copper and aluminium condenser coils, preventing leakage of gas due to atmospheric and salty /chemical corrosion, complete etc as required
Supplying and Charging of Refrigerant Gas ( R-407 ) for charging in the existing AC Package unit i/c testing and commissioning etc as reqd.
SH III ( Credit of faulty material in work)
Credit of defective dismantailed condensor coil ( The agency shall offer suitable credit )
VISHAL CONTRACT WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .