| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.9 L+₹2.2 L (6.13%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹40.4 L+₹3.8 L (10.3%)Rejected-AOC | L3 | Rejected-AOC Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Dec 2019, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
REPAIR RECTIFICATION OF DAY TO DAY COMPLAINTS OF EXTERNAL ELECTRIFICATION SUPPLY SYSTEM INCLUDING REPIRS REPLACEMENT OF LT DISTRIBUTION AT ZONE I C, BOWENPALLY UNDER AGE EM NO- I OF GE U SECUNDERABAD
2019_MES_294241_1
GE(U)/SEC/TOKEN/27 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹90,000
Yes
14 Jan 2020
1 Nov 2019
4 Dec 2019
1 Nov 2019
2 Dec 2019
16 Nov 2019
Amount
M&L for attending, repair and rectification of external LT/HT electric supply compliants on 1100/11000 Volts grade, under ground / over head system alongwith necessary T&P, safety devices as per site requirement for the following type of compliants complete all as specified and directed:-
Replacement of LT blown out fuse as per existing capacity in any location upto 200 Amps.
Replacement of wornout jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Trimming/prunning and removing of tree branches or any other forein objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of necessary T&P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
Replacement of worn out Insulators of any type and size suitable for existing 1100/11000 Volts grade Line.. Note:- Insulators shall be measured and paid separately under respective items.
Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Notes:- (i) LT Jointing kits, XLPE Cables of any size, cable protection pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the Pole coping and inserting the cable along with protection pipes amd making good coping to match with original.
All as per item Sl No 1.05 above but from LT/HT switch gear/main switch board of any type and size including provision of suitable size of aluminium / copper cable lugs.
Replacement of rusted/ broken over head conductor of any type and length as required at site including removing of foreign objects if any from the over head lines. Notes:- (i) ACSR conductor used for replacement will be measured and paid under respective items. (ii) Quoted rate is deemed to be inclusive of trimming of tree branches up to 1.5 Mtr around the conductor.
Replacement of faulty LT switch gear of any type and size fixed in panel board pole mounted boxes on walls or any other indicated places including provision of lugs/thimbles of suitable sizes. Note: - Switch gears used for replacement will be issued under relevant items of this schedule.
Replacement of blown out DO fuse, 11 KV grade of any capacity. Notes: (i) Quoted rate is deemed to be inclusive of Fuse wire of required gauge and necessary T&P required at site. (ii) No additional payments will be admissible for replacement of fuse in same system with in 24 hrs. (iii) Set of 3 fuses will be considered as one job for payment purpose.
Replacement of street light timers of any capacity, in any location. Note: Spares for repair of Street light timers or New timer switches will be measured and paid separately.
Taking down unserviceable Street light fittings in any position of any capacity, repair of street light fittings by replacement of unserviceable spares like Ballast/ HPSV lamp/MH lamp/CFL Lamp/Ignitor/ Capacitor etc and refixing the same in existing location. Note:- Spares for repair of street light fittings will be measured and paid under respective items.
Replacement of Energy meter of any capacity and any type. Note:- Energy meters will be issued under Sch 'B' free for fixing only.
Notes for Item Nos 1.01 to 1.12:- (a) The contractor will be alloted complaints at MES complaint cell on required basis on all working days and sufficient resources will be deployed by him/her for completion of day to day comaplaints within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No I store on daily basis.
Supply only the following materials suitable for existing LT distribution system as in repairs/replacements complete all as specified and directed.
Aluminium Conductor Steel Reinforced (ACSR) conductor of any size for LT/HT over head line connections of squirrel/weasel/mink as per site requirement including provision of aluminium binding wire,using as jumpers etc.complete.
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade.
Shackle type insulator, porcelain vitreous, white / brown / green, 1100 Volts grade, 75 mm height & 90 mm dia including galvanised mild steel strap of 31 x 3 mm, 12 mm dia insulator bolt, washers & nuts.
Loop type insulator porcelain vitreous white, brown or green with overall dimensions of 90 x 140 mm, clearance of hole 25.5 mm.
Single disc type insulator porcelain vitreous white, brown or green with overall dimensions of 145 mm hight and 225 dia, ball and socket type coloured single disc assembling for 11000 volts grade.
MCCB 63 Amps, 3 pole, 415 Volts with rapturing capacity 16 KA, adjustable thermal and fixed magnetic settings.
MCCB 100 Amps, 3 pole, 415 Volts with rapturing capacity 16 KA, fixed magnetic and thermal settings.
MCCB 160 Amps, 3 pole, 415 Volts with rapturing capacity 25 KA fixed magnetic and thermal settings.
MCCB 200 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA fixed magnetic and thermal settings.
MCCB 250 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA fixed magnetic and thermal settings.
MCCB 400 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA adjustable magnetic and thermal settings. Note for Item Sl No 2.06 to 2.11 : Any modefication/ altration in existing panel which is required to fixing of MCCB is deemed to be included in unit rate
M&L for cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia as in repairs complete all as specified and directed.
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through joint with jointing material and accessories suitable for aluminium conductor cable of size upto 95 sqmm, 3.5 Core complete all as specified and directed.
All as per item No 4 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core.
All as per item No 4 here-in-before but suitable for aluminium conductor cable of size from 240 sqmm, 3.5 Core to 400 Sqmm, 3.5 Core.
Supply, lay, test and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volls grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of following sizes including disconnecting and taking down existing damaged/joints of ACSR conductor of any type from trenches/ducts/poles/walls etc complete all as specified and directed :-
2 core X 10 Sqmm
4 Core X 16 Sqmm
4 Core X 25 Sqmm
4 Core X 35 Sqmm
3.5 Core X 50 Sqmm
3.5 Core X 70 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 185 Sqmm Notes for item Nos. 7.01 to 7.09 :Excavation, earth work, sand cushioning and cable protection items etc shall be measured and paid under respective items of Schedule 'A'.
Labour only for Restreching/releasing the binding of ACSR conductor of LT / HT over head line from insulator, removing the jumper, connector, service wire, UG cable and restringing the existing ACSR conductor of any size, length, span upto desired sag and fixing the existing ACSR conductor on insulators by proper binding, jumper connection etc complete all as specified and directed. Notes:- (i) The distance between pole to pole in running meter (2/4/6 runs) i.e one span will be measured as one unit for payment purpose. (ii) Extra aluminium conductor requiured for jumpers and binding purpose is deemed to be included in the quoted unit rate. (iii) Trimming of tree branches upto 1.50 Mtrs distance around conductor is included in the unit rate quoted.
M&L for testing earthing of installations, buildings, equipments etc and treating of earthings by pouring salt water and submit results sheet to AGE E/M No-I complete all as specified and directed. Note: Contractor has to arrange necessary tools required for the job
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed.
M&L for stay assembly with all accessories as shown in Electrical Plate No 1 of SSR Part I (2009) with 16 mm dia stay rod and including 7/2.24 mm size stay strand and stay clamps including dismantling old unserviceable stay assembly complete all as specified and directed. Note : Loop type insulator, excavation, earth work and concrete shall be measured and paid separately under relevant items of this schedule.
M&L cross arms, bracing supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as directed including applying two coat of Ist quality aluminum paint over one coat of red oxide primer and fixed over Pole of any height and in any position as in replacement of old unserviceable cross arms etc complete all as specified and directed.
M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with one coat of aluminium paint and cleaning the existing surface thoroughly, writing of pole numbers in yellow circle 15 cm with black paint on poles and painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) with one coat of acrylic paint above coping complete all as specified and directed.
M&L for painting the existing LT PCC poles of 9.0 Mtr long with one coat of acrylic paint including cleaning the existing surface thoroughly and painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height with acrylic paint, writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC/Steel poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M&L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of plate not less than 1.5m below ground level, connecting to the galvanised iron earth strip 32 x 6mm dia by means of nuts, bolts, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point and testing on completion including taking down old unserviceable earthing all as directed. Note :- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
M&L earthing complete with copper earth plate electrode 30cm x 30cm x 3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of plate not less than 1.5m below ground level, connecting to the copper earth strip 20 x 3mm dia, by means of nuts, bolts, check nuts and washer etc of copper and earth strip protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point and testing on completion including taking down old unserviceable earthing all as directed. Note :- The cost of 7.5m long copper earth strip of 20 x 3mm size and protection pipe of 40mm bore GI medium grade is deemed to be included in quoted unit rate.
M&L copper strip of size 20 x 3 mm with saddles and fixing screws etc for roof conductors and down conductors above ground fixed in position complete all as specified and as directed.
S&F bracket made out of 40 mm GI pipe light grade up to 1.5 mtr long bending to shape with two Nos flat iron clamp of size 40 x 6 mm thick with nuts and bolts including duly painted with two cores of synthetic enamel paint over a coat of primer (GI surface shall not be painted) and fixing on pole as in repairs complete all as specified and directed.
S&F Energy saving & Environmental friendly long life Varsatile pressure die cast aluminium alloy for housing (heat sink) with IP66 protection road way light fitting with high power LED as light source of capacity 60 watts with warranty option of 5 years with suitable driver and cable gland for maintaining ingress protection with Epoxy powder coated siemens grey finish after phosphochromate treatment, Tempered protective toughened glass,thermal shock and impact resistant fixed to the housing with SS screws , High efficiency long life LED chip in modules with lumen efficacy of >140 lm/W with PC lens and system lumen 6000. Powered by Built-in electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection. CCT 5700, CRI>70, THD<10%, PF>.95, IP66, IK07.Life class of 50,000 hrs @ L70, Operating
Temperature:-10 TO +50 DEG.C; Input Supply Voltage Range:140-270 V, Frequency:50-60 HZ. Driver safety requirement standards :IS 15885-2-13, Test report to be submitted for Driver performance requirements as per IS 16104, for Photo bilogical safety norms as per : IS 16108, Certification as per LM 79 for Luminaire , LM 80 for LED Source, with all standard accessories etc with provision of GI bracket 40 mm bore light grade, 2 Mtr long, necessary FI clamps 50 x 6 mm with bolts, nuts and washers and 2 runs of cable PVC insulated single core unsheathed 1100 volts grade 4 Sqmm multistranded with aluminium conductor from fitting to LT OH line including disconnecting and taking down old existing light fittings any type/capacity from any height/position complete all as specified and as directed.
Make: Bajaj Cat No.BRTFG 60W LED V3 or Havells Cat No. ENDURAPEARLPLUSSL60WLED757SASYTOPC or Wipro cat No. LR02-671-XXX-57-G2 or techno commercial techno commercial equivalent model in Philips.
All as per item No 27 above, but 45 Watt LED Street light fitting with minimum system lumen out put 4500 lumen. Make:- Bajaj Cat No.BRIL 45W LED NW or Havells Cat No. ENDURAPEARLNEOSL45WLED757SASYTOPC or Wipro cat No.LP07-507-XXX-57-CL or techno commercial techno commercial equivalent model in Philips.
All as per item No 27 here-in-before but road way light fitting of high power LED as light source of capacity 200 watts with minimum system lumen out put 20000 lumen. Make: Make : Bajaj Cat No.BRTFG 210W LED or Havells Cat No. ENDURACITYLINERNEOSL200WLED757PSPYBOTG or Wipro cat No. LR02-242-XXX-57-G2 or techno commercial techno commercial equivalent model in Philips.
S&F post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X25 watts and connecting with 2.5 sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed. Make:- Bajaj Cat No.BLPTSP 25W NW LED or Havells Cat No. RUBYPT25WLED757PSYMTOPC or Wipro cat No.LP07-251-XXX-57-CL or techno commercial techno commercial equivalent model in Philips. Notes for item Nos 27 to 30 :- (i) LED's used should be the make of Cree/Osram/Lumilieds/Nitchia, (ii) Contractor has to produce LM-79/ LM-80 certificate along with purchase vouchers and Guarantee certificate from Manufacturer. (iii) Surge protection (In-built) of the drive shall not be less than 10 KV.
S&F in repairs Electronic drivers suitable upto 75W LED light fittings suitable to operate on input voltage of AC 85-265 V, 50 Hz, Output DC 42-65 V, 300 MA, 0.95 PF complete all as speicified and directed.
S&F in repairs Electronic drivers suitable up to 100W LED light fittings suitable to operate on input voltage of AC 100-265 V, 50 Hz, Output DC 36 V, max 350 MA, 0.95 PF complete all as speicified and directed.
S&F in repairs Surge protection of 10 KV suitable up to 100W LED light fittings suitable to operate on input voltage of AC 440 V, 50 Hz complete all as speicified and directed. Make for sl item No.31 to 33 : Havells/CG/C&S/Bajaj/Philips/Wipro
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated Aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed twin core of size 6 sq. mm nominal cross section in service connection complete all as specified and directed.
Supply & lay galvanised Iron tubing 50mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified and directed.
All as per item No 39 above but GI tubing 80 mm bore. Make for item No 35 & 36 : TATA/Jindal/Zenith.
S&F On- load changeover switch in sheet metal enlosure with front handle operating system, powder coated, factory made of capacity 100 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCFFE0100 or equivalent make in Havells/Legrand/IndoAsian.
S&F Off- load changeover switch in sheet metal enlosure with front handle operating system, powder coated, factory made of capacity 200 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCFFE0200 or equivalent make in Havells/Legrand/IndoAsian.
S&F for timelite street light control distribution board, outdoor type, pole mounted, made out of 3mm thick MS sheet duly powder coated front openable, IP 65 protection with 2 Nos FI clamps of size 30mm x 4mm complete all as specified and directed including including taking down old unserviceable one and provision of the following accessories:- (a) Timelite-32A 3 pole/230 V Astronomical Time switch Digital switch din type, astronomical programmable every 1 min, backup 6 years, 28 memory locations, current capacity 16 Amps, with 1 changeover (1 CO), total 28 programmers - 01 No. Make:- Indo Asian Cat No. TLO32ASO or equivalent make in L&T/Legrand. (b) Power contactor heavy duty 40 Amps TP - 01 No. Make: L&T/Legrand/IndoAsian. (c) MCB TP 440 V, 40 Amps - 01 No. (d) Connector terminal 40 Amps - 06 Nos. (e) Auto manual switch - 01 No. Make for (c) to (e): Standard/L&T/IndoAsian/Legrand.
Supply and fill distilled water in batteries of solar street lights of any capacity and in any height complete all as specified and directed.
S& F in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 25 Sqmm including necessary connections complete all as specified and directed.
All as per item No 41 above but aluminium lugs of size 35 Sq mm.
All as per item No 41 here-in-before but aluminium lugs of size 50 Sq mm.
All as per item No 41 here-in-before but aluminium lugs of size 70 Sq mm.
All as per item No 41 here-in-before but aluminium lugs of size 95 Sq mm.
All as per item No 41 here-in-before but aluminium lugs of size 120 Sq mm.
All as per item No 41 here-in-before but aluminium lugs of size 150 Sq mm.
All as per item No 41 here-in-before but aluminium lugs of size 185 Sq mm.
Supply, Fixing and testing MCB isolator three pole and neutral (TPN) 440 Volts of capacity 63 Amps, 16 KA, 'C' curve complete all as specified and directed.
All as per item No 49 above but of capacity 100 Amps, 16 KA
Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 100 KVARs and up 8 stages installed at various locations at Bowenpally area including carrying out complete maintenance/repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed.
Notes:- (i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, repavement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same. (ii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/MCCB and fixing/installing/testing and commissioning the complete system. (iii) Major Spare parts viz,capacitor banks, APFC relay, power contactor, control CT, MCBs/MCCB shall be measured and paid seperatly.
S&F power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old existing capacitor complete all as specified and directed.
All as per item No 52 above but 10 KVAR Capacitor Bank
All as per item No 52 here-in-before but 15 KVAR Capacitor Bank
All as per item No 52 here-in-before but 20 KVAR Capacitor Bank
All as per item No 52 here-in-before but 25 KVAR Capacitor Bank
All as per item No 52 here-in-before but 50 KVAR Capacitor Bank Make for item No 52 to 57:- L&T CAT No LTBCH or equivalent Make in Legrand/Standard/ Havells /Schneider
S&F APFC relay etaCON M series with auto-set function 5 stage including taking down old existing one complete all as specified and directed. Make:- L&T Cat Part No ETACONM005R or equivalent make in Schneider/Legrand/Indo Asian.
All as per item No 58 above but APFC relay with auto-set function 7 stage Make:- L&T Cat Part No ETACONM005R+ETACONEXP3R or equivalent make in Schneider/Legrand/Indo Asian.
S&F in repairs, capacitor duty contactor, type MO C built in auxillary contact blocks, 8.5 KVAR, 440 volts, 3 phase, 50 Hz, type MO C8.5 complete all as specified and directed. Make:- L&T Cat Part No CS96320 or equivalent make in Schneider/Legrand/Indo Asian.
All as per item No 60 above but capacitor duty contactor, type MO C30. Make:- L&T Cat Part No CS96148 or equivalent make in Schneider/Legrand/Indo Asian.
All as per item No 60 here-in-before but capacitor duty contactor, type MO C50 .Make:- L&T Cat Part No CS96324 or equivalent make in Schneider/HPL/Indo Asian.
Sri Balaji Enterprises
M Laxmana Rao and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .