| 1 | L1₹16.2 LAccepted-AOC 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L1 | Accepted-AOC L1 Quoted | |
| 2 | L2₹16.8 L+₹2,233.57 (0.13%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC L2 Quoted | |
| 3 | L3₹19.4 L+₹2.6 L (15.6%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC L3 Quoted | |
| 4 | L4₹19.5 L+₹2.7 L (15.9%)Rejected-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L4 | Rejected-AOC L4 Quoted | |
| 5 | L5₹19.9 L+₹3.0 L (18.1%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L5 | Rejected-AOC L5 Quoted |
Tender Value
₹25.0 L
EMD Value
₹49,920
Closing Date
26 Jul 2022, 6:00 pmClosed
GE(AF) Chandigarh
GE(AF) Chandigarh PIN-160003
REPAIR TO PERIMETER LIGHTS LT DISTRIBUTION NETWORK,JUNCTION BOXES AND CONTROL PANEL AT 12 WING (AF) STN CHANDIGARH
2022_MES_532731_1
GE(AF)/CHD/T-13/2022-23
Open Tender
Civil Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE(AF) Chandigarh
₹49,920
Yes
30 Aug 2022
22 Jun 2022
2 Aug 2022
22 Jun 2022
26 Jul 2022
6 Jul 2022
22 Jun 2022 - 28 Jun 2022
Amount
Checking and maintenance of street lights, high mast light of any height and any type of fittings HPSV/ HPMV/ MH/ Flood light/ Halogen light/ LED light fitting of capacity 40/ 60 watt/ 90watt/ 120watt/ 150 watt/ 200 watt etc. AC 230 volt any wattage from pole opening of all components, through cleaning including washing of perplex cover inspection for location of fault and replacing of defective spares/ parts required for smooth functioning, tightening of electric connections complete and making the fitting on 100% serviceable condition includes rectification of fault of street lights over head line and underground cables of any size complete all as specified and as directed. Notes:- (i) The contractor shall deploy minimum 01 No. electrician and 02 No. helper including Sundays & holidays for the purpose of repair of security lights on daily basis. Supervisor shall collect complaint slip from main power house and return after completion of complaint to concerned JE. (ii) All T&P/ safety items shall be provided by the contractor at his own cost. (iii) The contractor’s quoted rate shall be deemed to include arrangement of bucket crane of suitable height or any other means required to rectify the complaints at height of 11/ 24m. Safety of the tradesmen employed shall be the responsibility of the contractor. (iv) Replacement of defective parts will be measured and paid for separately. However, cost of replacement of minor parts such as nuts, bolts, washers etc. shall be deemed to be included in the quoted rates.
Supply only constant current LED driver 10 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 85 to 265 Volts AC. (b) Frequency- 50/60 Hz. (c) PF- 0.98. (d) V out- 28 to 43 V DC. (e) I out- 100 mA.
Supply only constant current LED driver 30 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 85 to 265 Volts AC. (b) Frequency- 50/60 Hz. (c) PF- 0.98. (d) V out- 28 to 43 V DC. (e) I out- 100 mA.
Supply only constant current LED driver 45 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 187 to 280 Volts AC. (b) Frequency- 50/60 Hz. (c) PF- 0.98. (d) V out- 30 to 42 V DC. (e) I out- 250 mA.
Supply only constant current LED driver 60 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 100 to 265 Volts AC. (b) Frequency - 50/60 HZ. (c) PF- 0.98. (d) V out- 30 to 42 V DC. (e) I out- 350 mA.
Supply only constant current LED driver 90 watts IP 65 of following specifications:- (a) Operating voltage Range- V (in) 120 to 277 volts AC. (b) Frequency- 50/ 60 Hz. (c) PF- 0.98. (d) V out- 64 to 143 V DC. (e) I out- 700 mA.
Supply only constant current LED driver 120/ 150 watts IP 65 of following specifications:- (a) Operating voltage range- V (in) 120 to 277 volts AC. (b) Frequency - 50/60 Hz. (c) PF- 0.98. (d) V out - 64 to 140 V DC (e) I out- 1050 mA.
Supply only constant current LED driver 200 watts IP 65 of following specifications:- (a) Operating voltage range- V (in) 198 to 264 volts AC. (b) Frequency - 50/60 Hz. (c) PF- 0.98. (d) V out- 71 to 21 V DC. (e) I out- 2800 mA.
S&F in repair LED surge protection device having maximum discharge surge current (Imax)- 10kA (8/20 µs), Nominal discharge surge current (In)- 5kA (8/20 µs) and protection level (Up) upto 5 kv; upto 200 watt security light/ flood light fitting all as specified and directed.
Supply & replacement of battery bank 11.1 volts, 33 AH lithium ion type for solar light of 28 watt complete all as specified and directed. Make: CARYVolt/ Das Electrical.
Supply & replacement of energy saving LED street light 60 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 5000K, 500(±) system efficiency should be minimum 100 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection complete all as specified and directed.
Supply & replacement of energy saving LED street light 90 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 9000K, 500(±) system efficiency should be minimum 110 lumen/ watt and minimum system lumen package of 9900 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection complete all as specified and directed.
Supply & replacement of energy saving LED flood light 50 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 4900K, 500(±) system efficiency should be minimum 98 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection complete all as specified and directed.
Supply & replacement of energy saving LED flood light 200 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 6500K, 500(±) system efficiency should be minimum 120 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection complete all as specified and directed.
Supplying and fixing in replacement 10sqmm flat twin core heavy duty cable 1100 volts grade PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and directed.
Supplying and fixing in replacement 6sqmm flat twin core heavy duty cable 1100 volts grade PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and directed.
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 35 sqmm, 3½ core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable with brick protection complete all as specified and directed.
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 25 sqmm, 4 core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable with brick protection complete all as specified and directed.
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 16 sqmm, 4 core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable, complete all as specified and directed.
Supply and laying in replacement 40mm bore GI tubing light grade pipe with all fitting laid in trenches, fixed to wall etc. complete all as specified and directed.
Supply and laying in replacement 50mm bore GI tubing light grade pipe with all fitting laid in trenches, fixed to wall etc. complete all as specified and directed.
Supply and fix water proof ABS electric distribution box, wheather proof IP-65 protection suitable for outdoor use, pole mounted, factory made of size 300mm x 250mm x 150mm comprising one No. MCB SP 6 Amps, 240 volts SPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 5mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts and washers made of galvanized iron and connection thimble etc. complete all as specified and directed.
M&L for pole mounting bracket made out of 50mm dia GI light grade pipe, L-shape 1.2m long with 40mm x 5mm thick FI clamps, hole fasteners, nuts and bolts, including welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed suitable for fixing light fitting including two coats of aluminium paint fixed in replacement complete all as specified and directed.
M&L for boring of holes under road, pavement, hardstanding etc. by any means for inserting GI/ CI/ HDPE pipe upto 100mm bore complete all as specified and directed.
Excavation in trenches in any type of soil n. exc. 1.5m deep and n. exc. 1.5m in width and getting out including forming bottom surface to required slope/ gradient for laying cables/ pipes etc. complete all as specified and directed. Notes: (i) Excavation shall be done carefully to avoid damage of existing cables and protection covers. (ii) Excavation work may be got carried out in short lengths for locating fault in under ground cables at different locations.
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers, each layer not exceeding 25mm thick in soft/ loose soil complete all as specified and directed.
Removing excavated spoil n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning to cables with a layer of sand 8cm thick before laying the cable and 15cm thick punned down after laying and stretching of cable) complete all as specified. (Punned thickness (overall 18cm) shall be measured & paid).
M&L old size sub class ‘B’ bricks for protection to cable laid flat abutting each other perpendicular to direction of cable direction complete all specified and directed.
M&L for PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of poles including necessary formwork complete all as specified and directed.
M&L for preparation old painted surfaces of LT steel poles 9.00m long and painting applying one coat of synthetic enamel paint in 30cm wide strips alternate in black and yellow colour upto 1.5 mtr height above puff and the remaining portion with one coat of aluminium paint and writing pole no on pole with white paint, complete all as directed at site all as specified and directed.
Supply and installing electro mechanical timer switch Quartz 1 channel weekly dial conforming to with 200 hrs battery reserve, programming by captive segment, manual override function in sheet metal enclosure with TPN MCB 63 Amps and power contractor 63 Amps 3 phase (Coil voltage 230V 50Hz) and one No MCB 6 amps for remote switch control a power complete all as per manufacturer's specifications including taking down old unserviceable fittings of any size/ wattage complete all as directed.
Supply and fix aluminium cable lugs suitable for 10 Sqmm to 25 Sqmm size cable all specified and directed.
Supply and fix aluminium cable lugs suitable for 35 Sqmm to 50 Sqmm size cable all specified and directed.
Supply, fix, connecting and testing MCCB four pole, 63 Amps, 415 volts, 16kA breaking capacity with adjustable thermal setting having Ics= 100% Icu including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 100 Amps, 415 volts, 25kA breaking capacity with adjustable thermal setting having Ics= 100% Icu including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 125 Amps, 415 volts, 25kA breaking capacity with adjustable thermal setting having Ics= 100% Icu including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 160 Amps, 415 volts, 25kA breaking capacity with adjustable thermal setting having Ics= 100% Icu including taking down the existing one complete all as specified and directed.
S&F in replacement MCB, SPN, 230V, 6 Amps AC, 10 KA, 'C' series and 50Hz complete all as specified and directed.
M&L repair to door hinges and door locks of LT panel board/ feeder pillar box of any size any description including scrubbing/ scratching of old rusted paint by burning through blow lamps and painting the complete of LT panel board/ feeder pillar box externally and internally with 02 coats of approved colour superior quality synthetic enamel paint over a coat of red oxide primer complete al as specified and as directed.
Site clearance including cutting of grass/ trimming of all bushes/ small trees upto a height of 10 feet in surrounding areas of perimeter security lights, E/M installations, panels, bus bar chambers etc. including sprinkling of herbicide solution as per manufacturer's instructions complete all as specified and directed.
M&L for dismantling old earthing and providing new earthing complete with galvanised steel earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to galvanised iron strip of size 25mm x 4mm by means of bolts, nut check nuts and washers earth strip protected by galvanized steel pipe 40mm bore (light grade) connected to test point all as shown in electrical plate No. 3 of SSR - 2009 (Part-I) and including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1;2:4), type B-1 reinforced XPM of weight not less than 4 Kg/ Sqm and MS frame etc. complete & connected to earthing test point all as specified or indicated including brazing/ testing on completion complete all as specified and directed. Notes:- (i) The unit rate includes galvanised Iron strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/ test point. (ii) The complete earth system shall be guaranteed to give result less than 5 ohm resistance.
M/s badrinath Traders
R D Bansal
M/s Friends Engineering Works
HARISH SALES CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .