| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | ₹24.1 L Quoted ₹25.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹28.3 L+₹2.4 L (9.40%)Rejected-Finance | ₹28.3 L+₹2.4 L (9.40%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹32.3 L+₹6.4 L (24.9%)Rejected-Finance | ₹32.3 L+₹6.4 L (24.9%) | L3 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Manisha Enterprises L3 | SWASTIK INFRA L1 | M/s Advance Stage Lights L2 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed .
Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above. | 20 | Each job | 500 ₹10,000 | 150 ₹3,000 Lowest | 200 ₹4,000 |
| 2.00 | S & F in replacement over load protector relay suitable for 40 to 150 litrs Litres capacity water coolers complete all as specified and as directed . | 4 | Each | 150 ₹600 | 150 ₹600 | 100 ₹400 Lowest |
| 3.00 | S & F in replacement Starting relay suitable for 40/80, 60/120, 150/150 Litre complete all as specified and as directed . | 4 | Each | 180 ₹720 | 150 ₹600 | 100 ₹400 Lowest |
| 4.00 | S & F in replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers. | 4 | Each | 280 ₹1,120 | 200 ₹800 | 100 ₹400 Lowest |
| 5.00 | S & F in replacement condenser motor fan blade suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed . | 4 | Each | 140 ₹560 Lowest | 500 ₹2,000 | 500 ₹2,000 |
| 6.00 | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/32hp to 1/16 HP as per site requirment from water cooler cap.40/80,60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. | 5 | Each Job | 900 ₹4,500 Lowest | 1,100 ₹5,500 | 1,500 ₹7,500 |
| 7.00 | S & F in replacement Starting Capacitor 25 MFD complete all as specified and as directed . | 8 | Each | 180 ₹1,440 Lowest | 200 ₹1,600 | 190 ₹1,520 |
| 8.00 | S & F in replacement running Capacitor 10 MFD complete all as specified and as directed . | 8 | Each | 120 ₹960 Lowest | 150 ₹1,200 | 260 ₹2,080 |
| 9.00 | S & F in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed .
( Suitable for Voltas/Sidwal/Blue Star make water coolers). | 2 | Each job | 750 ₹1,500 | 400 ₹800 | 360 ₹720 Lowest |
| 10.00 | S & F in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed. | 30 | Each | 290 ₹8,700 Lowest | 400 ₹12,000 | 390 ₹11,700 |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
15 Apr 2026, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT SPLIT /WINDOW TYPE AC WATER COOLER, DESERT COOLER, DEEP FREEZERS AND REFRIGERATORS FOR AREA-II AT AIR FORCE STN JAISALMER
2026_MES_750369_2
8409/GE/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
GE (AF) Jaisalmer
As per tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jaisalmer
₹45,000
Yes
28 Jul 2026
1 Apr 2026
17 Apr 2026
1 Apr 2026
15 Apr 2026
8 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed .
Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above. | 20 | Each job | - | - |
| - | S & F in replacement over load protector relay suitable for 40 to 150 litrs Litres capacity water coolers complete all as specified and as directed . | 4 | Each | - | - |
| - | S & F in replacement Starting relay suitable for 40/80, 60/120, 150/150 Litre complete all as specified and as directed . | 4 | Each | - | - |
| - | S & F in replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers. | 4 | Each | - | - |
| - | S & F in replacement condenser motor fan blade suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed . | 4 | Each | - | - |
| - | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/32hp to 1/16 HP as per site requirment from water cooler cap.40/80,60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. | 5 | Each Job | - | - |
| - | S & F in replacement Starting Capacitor 25 MFD complete all as specified and as directed . | 8 | Each | - | - |
| - | S & F in replacement running Capacitor 10 MFD complete all as specified and as directed . | 8 | Each | - | - |
| - | S & F in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed .
( Suitable for Voltas/Sidwal/Blue Star make water coolers). | 2 | Each job | - | - |
| - | S & F in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed. | 30 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8409tenderdocument.pdf
Tender Documents • 1.47 MB
BOQ_849986.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .