Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-Finance 134 SHANTI COLONY ETAWAH | ₹44.3 L | L1 | Accepted-Finance Due to Lowest Rates |
| 2 | L2₹45.0 LRejected-Finance N A | FARIDABAD | HARYANA | 121004 | ₹45.0 L | L2 | Rejected-Finance Due to Higher Rates |
| 3 | L3₹48.7 LRejected-Finance | ₹48.7 L | L3 | Rejected-Finance Due to Higher Rates |
| 4 | L4₹48.7 LRejected-Finance | ₹48.7 L | L4 | Rejected-Finance Due to Higher Rates |
Tender Value
₹57.5 L
EMD Value
₹4.9 L
Closing Date
22 Apr 2026, 12:00 pmClosed
Superintending Engineer
39th Circle, PWD. Lucknow
Work of installing UPVC windows in the ground floor houses of Block No. 12 to 20 in Type-4 PWD Colony located at Jail Road, Lucknow
2026_PWDBL_1137235_1
735/131(1)M-39/2026, Dt. 24.03.2026
Open Tender
Civil Works - Buildings
270 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,354
Yes
₹4.9 L
Yes
Superintending Engineer, 39th Circle, PWD. Lucknow
25 Apr 2026
16 Apr 2026
22 Apr 2026
16 Apr 2026
22 Apr 2026
16 Apr 2026
16 Apr 2026 - 22 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres DSR 15.12.2 | - | Each | - | - | BI01010001010000000000000515BI0100001113 |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below DSR 15.12.1 | - | Each | - | - | BI01010001010000000000000515BI0100001114 |
| 3 | Fixed window / ventilator with mullion / transom. Using R2 series with frame (39mm & above ) x (39mm & above) & mullion (39mm & above) x (60mm & above). (Height upto 1.2 metre) DSR 9.147C2 | - | sqm | - | - | BI01010001010000000000000515BI0100001115 |
| 4 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre).DSR 9.147.A1.1 | - | sqm | - | - | BI01010001010000000000000515BI0100001116 |
| 5 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m). DSR 9.147.A1.2 | - | sqm | - | - | BI01010001010000000000000515BI0100001117 |
| 6 | Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm) DSR 9.7.7.2 | - | Sqm | - | - | BI01010001010000000000000515BI0100001118 |
| 7 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading DSR 9.135.2 | - | sqm | - | - | BI01010001010000000000000515BI0100001119 |
| 8 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125 mm DSR 9.92.1 | - | Each | - | - | BI01010001010000000000000515BI0100001120 |
| 9 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 12x 12 mm Square bar pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR 10.31 | - | kg | - | - | BI01010001010000000000000515BI0100001121 |
| 10 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand) DSR 14.1.2 | - | sqm | - | - | BI01010001010000000000000515BI0100001122 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.88 MB
T2735Jailroad.pdf
Tender Documents • 1.38 MB
BOQ_2123553.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid