Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹39.2 L+₹4.9 L (14.2%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹39.5 L+₹5.1 L (15.0%)Rejected-AOC 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹39.8 L+₹5.4 L (15.9%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹39.9 L+₹5.6 L (16.2%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹43.4 L
EMD Value
₹86,800
Closing Date
7 Feb 2025, 6:00 pmClosed
COL A K TRIPATHI, CWE
CWE (ARMY) BANGALORE, 101, DICKENSON ROAD, BANGALORE - 560042
PROVISION OF PARKING SHED NEAR FAMILY WELFARE CENTRE AT HEBBAL UNDER GE (NORTH) BANGALORE
2025_MES_692594_1
86363/E8
Open Tender
Civil Works
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹86,800
18 Mar 2025
10 Jan 2025
14 Feb 2025
10 Jan 2025
7 Feb 2025
31 Jan 2025
10 Jan 2025 - 17 Jan 2025
Amount
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard dense soil all as specified & directed.
Removing excavated material (soil) exc 1.50 KM but not exc 5 KM and depositing where directed all as specified & directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cables, pole foundation etc. not exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/Dense Soil all as specified & directed.
M&L for Plain Cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate in foundations, filling and mass concrete all as specified & directed.
M&L Reinforced cement concrete, design mix M-25 grade using 20mm graded crushed stone aggregate as in foundations footings, plinth beams, bases for columns, etc and mass concrete all as specified & directed.
M&L Reinforced cement concrete, design mix M-25 grade using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts all as specified & directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified & directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter fair finished flat surfaces all as specified & directed.
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions fair finished square/rectangular or polygonal surface all as specified & directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed.
M&L for Pre-cast cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregates as in solid block masonry exceeding 10 cm in width and setting in cement mortar (1:6) complete all as specified and directed
M&L for rendering 15mm thick cement mortar (1 :4) on concrete or brick masonary wall surfaces mixed with WPC as per manufacturer instruction all as specified and directed (Note : WPC shall be measured and paid separetely)
Supply only Liquid water proofing compound, ISI marked, all as specified and directed
Filling soil under floors or in foundations including spreading, levelling, watering and consolidation all as specified and directed Note:- Earth Obtained from excavation shall be utilized.
M&L for Hardcore of broken stone or boulders of gauge not exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and directed
M & L for Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in 75 mm thick in sub-base to flooring all as specified and directed
M & L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; all as specified and directed
M&L for preparations new plastered wall surfaces and applying three coats of white wash on internal wall all as specified and directed
S & F Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe-410- W(Gde-E-250) quality-B all as specified and directed
S & F Rolled mild steel work in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc Fe-410- W(Gde-E-250) quality-B all as specified and directed
S & F for Rolled mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410- W(Gde-E-250) quality-B all as specified and directed
M & L for Preparation of new or previously untreated steel surfaces over 10cm in width or girth not otherwise described & applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed
S & F for Mild steel work in wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and directed
M & L for Pre- painted galvatume aluminum zinc coating GI based trapezoidal profiled steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, 150 AZ as in roof covering/cladding to wall, fixed with self tapping screws all as per manufacturer instruction as specified and directed.
M & L for Pre- painted galvatume aluminum zinc coating GI based Plain profiled steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, 150AZ as in roof covering/cladding to wall, fixed with self tapping screws all as per manufacturer instruction as specified and directed.
M&L for PCC (1:3:6) type C2 Using 40 mm graded crushed stone aggregate as in 100mm thick plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed.
Excavation over areas not exc 1.50m deep and getting out in Soft/Loose soil complete all as specified and directed.
Removing excavated material (soil) exc. 250 m but not exc. 500 m and depositing where directed complete all as specified and directed.
M & L for Plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in 100 mm thick in sub-base to pavement all as specified and directed
M & L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed
Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed
M & L for Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in as in surface channel finished even & smooth complete all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete block walling surfaces mixed with water proof compound, finished even and smooth without using extra cement complete all as specified and directed
Removing the excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m high from the starting point.
M&L for Plain cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping, benching of manholes and similar work etc complete all as specified and directed
M & L for Precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slab for man hole and set in cement mortar (1:4) all as specified and directed
M & L for Point Wiring with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories including M S terminal boxes fabricated with 1.6mm thick M s sheet concealed in walls with laminated sheet top cover 3mm thick fixed with cadmium plated iron screws for housing switches, switch socket outlets, fan regulators etc., including provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the One light point controlled by one switch Note :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for concealed wiring to be included in point wiring.
S&F LED batten with luminaire suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed.
S&F Switch piano flush type, single pole one way 5 Amps all as specified and as directed
S&F MCB SPN 40 Amps, 240 volts C curves complete all as specified and as directed
S&F MCB single pole 6 to 32 Amps, 240 volts C curves complete all as specified and as directed
S&F MCB Distribution Board SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2009 and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in Reinforced cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel, mesh with G I watering pipe, protection pipe, lugs, test point complete all as specified and as directed.
M&L for sand cushioning with a layer of river sand 23 cm thick under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed (Note : Punned thickness will be measured for payment)
Supply & Laying sub class B burnt old size bricks for cable protection complete as specified as directed
Supply & Laying Under ground L T XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm x 2 core laid in trenches or fixed on wall complete as specified as directed
S & F G I tubing light grade 32 mm bore with all fitting laid in trenches/walls/Roads for cable protection complete as specified as directed.
Supply and fixing bldg security light fitting with LED luminaire 30 Watts with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection complete as specified as directed.
S&F Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including M S clamps made out of M S flat iron 25 x 6 mm , nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
B5BUILDING SOLUTIONS (BID ID -3228956)
SREE VINAYAKA ENTERPRISES (BID ID -3232069)
AMR CONSTRUCTIONS (BID ID -3233860)
K. VENKATESH NAIDU (BID ID -3231249)
J PUSHPALATHA ENGINEER AND CONTRACTOR (BID ID -3234209)
SMLP ASPHALTS (BID ID -3234032)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .