Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | ₹1.8 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹1.9 Cr+₹8.8 L (4.87%)Rejected-AOC H NO 35 JAYANAGAR P O KHANAPARA P S DISPUR DIST KAMRUP M ASSAM | KAMRUP M | ASSAM | ₹1.9 Cr+₹8.8 L (4.87%) | L2 | Rejected-AOC L2 |
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
14 Jun 2021, 12:30 pmClosed
Addl. CE, PWD (PCC), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of 15 bedded ICU and 32 Bedded Step Down ICU, Air Conditioning and other Electrical works at Govt. Ayurvedic College and Hospital (COVID-19 Hospital), Jalukbari
2021_PWBNH_21763_1
GAC-COV-19/02
Open Tender
Civil Works - Building
Item Rate
30 days
Jalukbari
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,400
Assam State Road Board Maintenance (Road) Fund
₹3.6 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
31 Jul 2021
29 May 2021
15 Jun 2021
29 May 2021
14 Jun 2021
5 Jun 2021
4 Jun 2021
Amount
EARTH WORK IN EXCAVATION Earthwork in excavation for foundation trenches of walls, retaining walls, footings of columns, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, wateringand rammingetc. and removal of surplus earth with all lead and lift as directed and specified in the following classification of soils including bailling out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (b) In hard/ dense soil GROUND FLOOR
PLAIN CEMENT CONCRETE WORKS Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume GROUND FLOOR
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser c) M25 grade concrete GROUND FLOOR
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (i) Using 38mm thick plank GROUND FLOOR
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level. (b) In proportion 1:4.(1 cement:4 sand) GROUND FLOOR
CEMENT PLASTERING 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4 GROUND FLOOR
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4 GROUND FLOOR
GYPBOARD CEILING Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). (ii) 12.5mm thick 2ND FLOOR
DISTEMPERING a) Removing dry or oil bound distemper by washing and scraping and sand papering the wall surface smooth including necessary repairs to scratches complete. INTERNAL SURFACE GROUND FLOOR
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. INTERNAL SURFACE GROUND FLOOR
EXTERNAL SURFACE GROUND FLOOR
"Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) 1.5 MM THICKNESS" INTERNAL SURFACE GROUND FLOOR
EXTERNAL SURFACE GROUND FLOOR
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) INTERNAL SURFACE GROUND FLOOR
Extra over item no 13.4.1 above for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). (i).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) INTERNAL SURFACE GROUND FLOOR
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer. GROUND FLOOR
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). GROUND FLOOR
Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) GROUND FLOOR
"Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) " a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar GROUND FLOOR
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire length and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters. GROUND FLOOR
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels GROUND FLOOR
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels. GROUND FLOOR
Demolishing the plastering from walls/ R.C.C. and P.C.C. members without causing any damage to the wall/ member upto any height including disposal of debris as directed for all levels. GROUND FLOOR
Demolishing mosaic floor of various thickness, both mosiac tiles and cast-in-situ type including CC base course and removal of debris as directed for all levels. GROUND FLOOR
2ND FLOOR
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 2 mm thick conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 2 mm thick conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.(ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) double door
6 way TPN (4+18) double door
8 way TPN (4+24) double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 4 way TPN (8+12) double doo
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series (Schneider MG, legrand, Hager make)" 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series (ABB, Schneider MG, legrand, Hager make)" 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 160A
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.(ABB, Schneider, legrand, L&T make) 400 A
Supply with installation & commissioning of readymade maintenance free CPRI approved technology G.I. CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
Supplying & laying of 25x5 mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department [ without regulator] Premium model 1200 mm Sweep (CROMPTON make), Premium model 1050 mm Sweep (CROMPTON make)
Supplying including fitting fixing of following A.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (CROMPTON /ORIENT/Havells/USHA or equivalent make) Wall 43 , 400 mm sweep
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENT make)
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 4.0 KVA Automatic Input 120-280 V Out put 200-240 V
5.0 KVA Automatic Input 120-280 V Out put 200-240 V
Supplying fitting fixing and connection as approved by the Deptt.)1/2 inch & 3/4 inch copper piping with insulation along with connection as approved by the Deptt.)cable including testing and commissioning as directed by the department.
Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories)" (i) In internal wall - exposed on wall (b) 20 mm OD
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 10.00 Sq.mm 3 Core armoured U.G. cable
185.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 185.00 Sq.mm 3&1/2 Core U.G. cable in 80 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMET make) DOUBLE compression BRASS GLANDS WITH NICKEL - PLATED FLAMEPROOF (CBF) Size: 1Size: 2.5 - 16, 3/4 "
Supplying fitting and fixing of single wall brackets Philips model 37554 (or equivalent as approved by the Deptt.) on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories including connection as required complete. (without Lamp).
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2 - module type
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6 Amps 3 pin universal combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 2 module
3 module
8 module
Supplying including and fixing of following Moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of department. 1-3 module Surface Moulded PVC boxes
8 module surface Moulded PVC boxes
Modular Motor Starter switch Relay Range 16 - 25 Amps in 3 Module
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. BN 021C LED 20 S PSU CW GR S2
Supplying with installation testing and commissioning of Hi -- wall INVERTER 3 STAR rating non ducted copper condencing unit split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.)up to 3 m between the room unit and out door unit as directed by the department. a) 1.5 Ton (Blue Star or equivelent make)
b) 2.0 Ton (Blue Star or equivelent make)
Supplying, installation, testing and Commission of the following indoor Decorative Recessed mounted 2' x 2' LED down lighter luminaries of model no- RC380 B LED 36S-6500 G4 L60 PSD OD WH OC / RC380 B LED 36S-6500 G4 L60 PSD OD WH OC / LCTRS-36-TL / LCTRS-36-CDL / IO2830RP00 / IO2840RP00 / IO2850RP00 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Crompton / LT make).
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-DN 393 B LED 12 S-6500 PSU WH / D01257R000 / D01240R000 / D01230R000 / CRDL11R017HP57 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar / LT / Wipro make).
Supply and fittting and fixing Better Power make ON-LINE UPS,3 Phase input 3 Phase output, with built in isolation transformer capacity : 60 KVA, model : MX Pro, with SFM battery for back up along with rack and inter connecting cable.
MEDICAL OXYGEN SYSTEM Supply, Installation, Testing & Commissioning of Oxygen manifold extendable type 16+16 size complete with middle frame with chain for individual cylinder (bulk cylinder D type) along with Non-Return valves for every cylinder and high pressure annealed copper tail pipes with 1 end having brass adaptor and other end suitable for manifold non return valves and manifold will have 10 brass non return valves for individual oxygen cylinder, middle frame with circumferential M.S. Flat duly powder coated all as specified and as per ISO 9001:2015 & 3 digit CE marked company.
Supply, Installation, Testing & Commissioning of 4+4 Cylinders Emergency Oxygen Manifold with two stage high flow rate regulator with NRV for every cylinder and copper tail pipes with top and middle frame for oxygen all as specified and as per ISO 9001:2015 & 3 digit CE marked company.
MEDICAL AIR SYSTEM Supply, Installation, Testing & Commissioning of INGERSOLL RAND/ ANESTIWATA MOTHERSON/ FS CURTIS oil free Air Compressor machine 15 HP, 3 Face, Duplex *Durable cast-iron with two Intermediate duty applications *Dual 15 Hp Air Compressor motor including necessary *Model: BFT 100 D-9E, CFM-36.66
Air Receiver Tank for Compressed Air System 1000 Ltr Capacity
Air Dryer Capacity 60 CFM
Three Stage bacterial filter assembly.
Pressure Reducing System with 2 (two) nos pressure regulators
MEDICAL VACCUM SYSTEM Supply, Installation, Testing & Commissioning of INGERSOLL RAND/ ANESTIWATA MOTHERSON vacuum Pump with accessories, base mounting, Capacity: 10 HP Duplex Model: 15V, CFM: 149.6 PD. 10 HP each Double Stage Vacuum pump including necessary Vacuum Accessories Like Silencer, & Vacuum Bacteria Filter.
Vacuum Receiver Tank 1000 Ltr. capacity
Supply, Installation, Testing & Commissioning of Copper Pipe: AS PER MEDICAL GRADE: LLYOD CERTIFIED 54MM OD x 1.2MM Thick
76MM OD x 1.2MM Thick
Supply, Installation, Testing & Commissioning of Isolation Valves with brass body with nickel plate valves operating handle suitable for 12mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications and as per ISO 9001:2015 & 3 digit CE marked company for the following Isolation Valve:- 54mm
MEDICAL OXYGEN SYSTEM Oxygen Control Station with automatic changeover from Duty Bank to Reserve Bank of cylinder Digital Display ,HP Regulators,including Safety Valves, Change Over Alarm etc.
BED HEADED PANEL Bed Headed Panel 5 ft Each with Accessories-- Monitor Tray B.P. Basket I.V. Hook Aluminium Clamp for Ward Vacuum Unit Provision for Nurse Calling System
COPPER PIPING Copper Pipe 12 mm OD X 0.7 mm thick
Copper Pipe 15 mm OD X 0.9 mm thick
Copper Pipe 22 mm OD X 0.9 mm thick
Copper Pipe 28 mm OD X 0.9 mm thick
Copper Pipe 42 mm OD X 0.9 mm thick
ZONAL/ISOLATION VALVES BRASS FITTINGS 12mm
GAS OUTLETS, FRONT INSERTATION TYPE DOUBLE LOCK PROBE Oxygen
Medical Air ( 4 Bar)
Vacuum
ACCESSORIES Oxygen Flowmeter with Humidifier
Ward Vacuum Unit with 600 ML Collection Jar(Compleate with vacuum regulator)
Ventilator Probe for Oxygen
MASTER ALARM Area Alarm 5 gas Service
AREA ALARM , INDIGENOUS Area Alarm 3 gas Service
Zonal Valve Box 3 Gas Service
Bora Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .