Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC aoc |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
29 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Mohanbari
Garrison Engineer AF Mohanbari Mohanbari Post Dibrugarth Assam 786012
PROVISION OF INFRASTRUCTURE FOR INSTALLATION OF NFS PROJECT AT AFS DINJAN UNDER GE (AF) MOHANBARI.
2021_MES_443572_2
NIT No . 8001/268/01/E8 OF 2021-2022
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Mohanbari
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Mohanbari
₹16,000
Yes
11 Sept 2021
13 Jul 2021
31 Jul 2021
13 Jul 2021
29 Jul 2021
15 Jul 2021
60 days
Amount
BUILDING WORK. Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in hard / dense soil. complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes,etc. but not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soft/ loose soil complete all as specified and directed by Engineer-in-charge.
Removal of surplus soil not exc 50m and depositing where directed at a level n. exc 1.5 m above the starting point. complete all as specified and directed by Engineer-in-charge.
M&L plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations/mass concrete complete all as specified and directed by Engineer-in-charge.
Material and labour RCC M25 (Design mix), as in footing, plinth beams and columns below GL and like including necessary form work complete all as specified and directed by Engineer-in-charge.
Material and labour RCC M25 (Design mix), as column above GL and like including necessary form work complete all as specified and directed by Engineer-in-charge.
Material and labour damp proof course to horizontal or vertical surfaces inluding necessary formwork, 40 mm thick, in cement concrete 1:2:4 type B0 complete all as specified and directed by Engineer-in-charge.
Material and labour RCC M25 (Design mix), as in beams, cantilevers, bressmers, lintels over 1.5m span supported on wall beams and column in floor, balconies desk slab, lintels and in shelves and the like including necessary form work complete all as specified and directed by Engineer-in-charge.
M&L high strength deformed TMT steel bars, as in reinforcement, 10 mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed by Engineer-in-charge.
M&L high strength deformed TMT steel bars, as in stirrups, spaces and binders, 5 mm dia and over upto and including 10 mm dia, cut to length, bent to shape required, including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips. complete all as specified and directed by Engineer-in-charge.
M&L for spreading, leveling in layers not exc 25 mm thick and well ramming in floors including, watering of soft/ loose soil complete all as specified and directed by Engineer-in-charge.
Material and labour for Brickwork with old size sub class locally available bricks, having compressive strength 75Kg/sqcm, straight or curved on plan excd 6 M mean radius in built in cement and sand mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for broken stone as Hard core of gauge n exc. 63 mm , deposited , spread and levelled in layer n exc. 150 mm thick, watered and rammed to a true surface. complete all as specified and directed by Engineer-in-charge.
M&L plain cement concrete 1:4:8 type D2 using 75 mm thick (using 40mm graded stone aggregate) as in sub base in flooring work. complete all as specified and directed by Engineer-in-charge.
M&L Plain cement concrete type C1 (1:3:6), using 75 mm thick (using 40mm graded stone aggregate) for plinth protection and surface finished even and smooth without using extra cement. complete all as specified and directed by Engineer-in-charge.
Material and labour for Cement concrete 40 mm thick type B-1 , 1:2:4 using 20 mm graded crushed stone aggregates as in hardstanding and top surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Material and labour for rendering 15 mm thick in CM 1:6 on brick / concrete surfaces finished fair and even without using extra cement internal wall surfaces complete all as specified and directed by Engineer-in-charge.
Material and labour for rendering 15 mm thick in CM 1 :4 on other than fair faces of brick / concrete surface as in external wall surface etc, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Material and labour for plain cement concrete type B-1 (1:2:4), using 20 mm graded crushed stone aggregate as in coping and similar works including necessary form work complete all as specified and directed by Engineer-in-charge.
M&L preparation of newly plastered /unplastered surfaces of walls by applying Wall care white ( Putty) thickness not less than 2mm and sand papering surfaces to achieve smooth surfaces and applying two coats, of exterior emulshion paint 100% acrylic white or any tinted as in (camouflage pattern) over a coat of cement based primer including washing floors, cleaning glass, joinery electrical fittings, wiring etc, or drops and splahes complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of newly plastered surfaces of walls by applying wall care white putty thickness not less than 2mm and sand papering surfaces to achieve smooth surfaces and applying acrylic based distemper emulsion, two coats, white or any tinted over a coat of chalk whiting including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and directed by Engineer-in-charge.
M&L Rolled mild steel in rolled sections in vertical posts as in main and cross beams, hip and jack rafters ; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W ( Gde-E-250) quality A complete all as specified and directed by Engg-in-charge.
Material and labour for 125 mm x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strikes plate, etc complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint (1st quality) over one coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, including ridge cover fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Supplying Glass dividing strips, 3 mm thick 38 mm wide and inserting in position complete all as specified and directed by Engineer-in-charge.
Supply and fix 30 mm thick Flush door shutter, solid core construction with block board core and plywood face panels commercial type on both side complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of new wooden/wood based material surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint (1st quality) over one coat of pink primer complete all as specified and directed by Engineer-in-charge.
S&F 300 mm long Aluminium alloy Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium and fixed complete all as specified and directed by Engineer-in-charge.
Supply and fixing 100 mm size, mild steel butt hinge medium weight cold rolled & fixed complete all as specified and directed by Engineer-in-charge.
Supply and fixing aluminium, anodised, barrel tower bolts of extruded section and fixed, 200 mm length of bolt complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 150mm size aluminium handles, cast type anodised complete all as specified and directed by Engineer-in-charge.
S&F aluminium body ( extruded section ) body Door closer hydraulically regulated, designation No. 3 , universal type , suitable for door shutters 851 to 1000 mm in width and of weight between 61 to 80kg complete all as specified and directed by Engineer-in-charge.
Material and labour for non asbestos fibre cement building board, 4mm thick, fixed to aluminium frame work with screw as in ceiling in flat or sloping complete all as specified and directed by Engineer-in-charge.
Supplying and fixing Aluminium anodised snap grid frame work as in false ceiling all as specified size of grid 605 X 605 mm with aluminium main T section of size 36.5 X 23.5 X 1.6 mm and cross T of size 23.5 X 23.8 X 1.6 mm with aluminium wall angle of size 36.5 X 23.5 X 1.6mm with suspender complete all as specified and directed by Engineer-in-charge.
Material and Labour for 3.2/3.3 mm thick Linoleum, plain coloured, laid dry in floors including stretching, cutting and fitting complete all as specified and directed by Engineer-in-charge.
Supply and fixed Mild steel, plain, black sheet 1.25 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws , clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with rivetted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engineer-in-charge.
Material and labour for Machine pressed precast concrete interlocking coloured tiles of 60 mm thickness, M-35 Grade any shape and size confirming to IS 15658-2006 in floors etc with grey cement and pigment over and including 40 mm thick sand cushioning under interlocking tiles complete all as specified and directed by Engr-in-charge.(Note: sand Cushion shall also deemend to be included in the quoted rate by the contractor)
INTERNAL AND EXTERNAL ELECTRIFICATION Supply and Laying sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23 cm (15cm under the cable & 8cm over the cable) and gently punned down to 18 cm thickness all complete all as specified and directed by Engineer-in-charge. Note : Only punned down sand shall be measured.
Material and labour for well burnt bricks having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring for light point/ fan point/ bell point, one light/fan/bell point controlled by one, one way modular switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (HR-FRLSH) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover including cutting chases pinning in for concealed conduit wiring and making good of disturbed surface not exc 15 cm girth and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor PVC insulated unsheathed (HR-FRLSH) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring for 6 pin 15/16 Amp switch socket combination on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (HR-FRLSH) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover including cutting chases pinning in for concealed conduit wiring and making good of disturbed surface not exc 15 cm girth and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor PVC insulated unsheathed (HR-FRLSH) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Supply and fixing socket 3 pin , 5 Amps, 230/240 V complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch socket combination 2 in 1 , 3 pin , (15/16 Amps ) flush type controlled by one switch complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed by Engineer-in-charge.
Supply and fixing ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC complete all as specified and directed by Engineer-in-charge.
Supply and fixing stepped type electronic fan regulator, flush type 240 Volts ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and fixing sheet metal enclosure single pole and neutral with two pin and earth plug and socket complete with one double pole MCB 20 Amps 240 volt complete all as specified and directed by Engineer-in-charge.
Supply and fixing sheet metal enclosure single pole and neutral with two pin and earth plug and socket complete with one double pole MCB 10 Amps 240 volt complete all as specified and directed by Engineer-in-charge.
Supplying and fixing two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed/surface, including 1.50 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed by Engineer-in-charge. Note :- Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item).
Supply and fixing LED Recessed mounted full lit luminaire 42 W (2ft X 2ft), lumens greater than 100 Lumens/ watt, square type, glare free uniform illumination with longer life and less maintenance, having seperate replaceable electronic driver, 230 volts, 50 HZ complete all as specified & directed by Engr-in-Charge.
Supply and fixed MCB SP, 5 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessary connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed MCB SPN 5-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Material and labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground( earth pit not less than 2.25 m deep below normal ground level ) with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI strip of size 25 mm x 4 mm thick as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron protected by 40 mm dia Galvanised iron pipe 'light grade' and connected to test points as directed all as shown in electrical plate No 3 of SSR part 1 complete all as specified and directed including testing on completion. Notes:- 1) The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, pre cast cover RCC (1:2:4) type B-1 cover slab with 8 mm dia TMT bar @150 center to center both ways with one handle for lifting made out of 8mm dia mild steel bar,GI funnel with GI watering pipe 20 mm bore 'medium grade', wire mesh and charcoal or coke of alternative layers of 15 cm, 32 mm bore galvanised iron pipe "light grade" for protection of earth lead connection. 2) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for free Chemical earthing system complete with 02 (two) nos. copper rods, internal rod of 19 mm dia and external rod is hollow and having internal dia. 48 mm and each rod of length 3000 mm electrode buired at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.6 m deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, including back filling of bore holes with advanced earth enhancing compound for artificial treatment to soil so as to achieve earth resistance below 01 ohms as specified in para 19.140 of SSR Part-I (2009) including three coats of white wash on plastered/PCC surface (Exposed surface), one coat of synthetic enamel paint of approved color on pit cover and pit number to be marked on a GI plate above 45 cm from GL as per color code followed in AF station including testing. Note : 1) The unit rate also including for excavation, earth work in any type of strata, PCC 1:3:6 mix, Type C1 pit, GI earth pit cover and GI plate for earth pit cover. 4) If the desired earth resistance is not achive during testing as per IS, the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
Supply and fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and directed by Engineer-in-charge.
Supply and fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 4 mm thick, galvanised iron strip using porcelain clit/post insulators, complete all as specified and directed by Engineer-in-charge.
Supply and Laying LT under ground XLPE cable of size 16 sqmm, 4 core including testing and commissioning insulated, screened, PVC bedded, armoured steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed by Engineer-in-charge. Note:- Excavation,sand cushioning,brick will be measured and paid separtely.
Supply and hanging of ceiling fan 1200mm sweep, jerk free rotation, 230 volt 50 Hz, AC single phase including all accessories and necessary electrical connection with suitable size PVC insulated copper multi stranded cable, engraving and marking MES No. and connecting and testing complete all as specified and directed by Engineer-in-charge.
Supply, installing, commissioing and testing , split type Air Conditioner of capacity 1.5 TR with rotary copper compressor, containing R-32/410 refrigerent, 4 way air direction, room temperature display, auto fan speed, auto swing, auto restart, exhaust command, suitable for working on 230 volts, single phase, 50 Hz supply, (Minimum 3 STAR Rating) complete including providing required copper piping, insulation etc, cutting of wall, powder coated steel brackets and making good disturbed surface of wall etc and remote operation complete all as specified and directed by Engineer-in-charge.
Supply and fixed 5 KVA automatic Voltage stabliser automatic boost / buck transformer for low and high voltage with electronic transistorised relay / time relay for two min, single phase, naturally air cooled, indoor type wall mounted, designed to give output voltage 230V + 5% at input range between 170 to 250 Volts complete all as specified and directed by Engineer-in-charge.
Supplying ,installing, testing and commissioning of floor mounted LT OUTDOOR, feeder pillar box, AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type , suitable for indoor use, with bottom cable entry with suitable cable glands structure made out of 2.00 mm thick with CPRI Approved CRCA steel sheet of Size ( 0.9 m x 0.9 m x 0.6 m) with angle iron frame work and legs of ISA 50 mm X 50 mm X 5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars, voltmeter, ammeter, changeover switche and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed by Engineer-in-charge. BUS BAR :- (a) Aluminium bus bar 200 Amps , supported on non hygroscopic fibres and brass screws for mounting -04 Nos INCOMER :- (a) Supply and fixing MCCB 4 pole 415 Volts with microprocessor controller of breaking capacity of 16 KA of 100 Amps with Fixed thermal and Fixed magnetic setting- 01 Nos INDICATING DEVICES :- (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos (b ) Supply and fixing Digital Ampere Meter of size 100mmX100mm for 0-300 A display , including CT having CTR 200/5 - 01 Nos & Digital Voltmeter 0-500 Volts , SIF 96 - 01 Nos
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .