Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC Found lowest bidder | |
| 2 | L2₹19.6 L+₹59,281.25 (3.12%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹22.4 L+₹3.4 L (17.9%)Rejected-Finance | L3 | Rejected-Finance third lowest | |
| 4 | L4₹24.2 L+₹5.2 L (27.1%)Rejected-Finance 25 SHIV SAROVER COLONY GARH ROAD MEERUT 250002 | MEERUT | UTTAR PRADESH | 250002 | L4 | Rejected-Finance Forth lowest | |
| 5 | L5₹25.0 L+₹6.0 L (31.5%)Rejected-Finance 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance Fifth lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
16 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North)
GE (North) Meerut Cantt PIN 250001
DAILY MAINT AND RESOLVING OF COMPLAINTS OF EM RECEIVED AT AGE EM I COMPLAIN CELL UNDER AGE EM I OF GE NORTH MEERUT CANTT
2023_MES_588482_1
8392/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut
Class D
Category b i
9 documents required · 9 mandatory
₹500
GE (North)
₹86,000
Yes
15 Jun 2023
6 Apr 2023
18 May 2023
6 Apr 2023
16 May 2023
20 Apr 2023
Amount
M&L carrying out repair by taking down and dismantling of internal unfunctional electrical fittings/ fixtures/ accessories/ articles/ description in electric supply / short circuit, checking its serviceability and renewal/ replacement of unserviceable parts such as switch socket, MCB, holders, tube light bulk head ceiling fitting any type replacement of modular plate / cover / boxes including carrying out the minor repair like fixing screws lightening of loose wires any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work on all working days after taking job card from AGE E/M-I complaint cell. complete all as specified and as directed. Note: (i) Minor repair carried out on the spot where no major item is involved shall be paid under this item (Such as No Light complaints without replacement of any major part) and other major item shall be measured & paid separately. (ii) Major items replaced as "supply and fixing" under respective item of this Schedule shall not be payable under this item. (iii) Adequate tradesman / supporting manpower shall be deployed by contractor and they shall be present on all working days including Saturdays and holidays from 0930 hrs to 1800 hrs for maintenance of above mentioned work. The supervisor / site Engineer of the contrator shall be forwarded detailed instructions of concerned AGE / JE every morning for attending complaits on daily basis. The persons shall be detailed by AGE concerned every morning for attending complaints on daily basis.
(iv) The complaints received before 1300 hrs shall be attended on same day. The complaints received after 1400 hrs shall be attended on the next working day before 1300 hrs. If complaints shall be not attended asper Schedule, pendalty of Rs 200/- shall be imposed on contractor for each complaint for each day. (v) Any delay in non-completion of complaints shall immediately be communicated to AGE / JE. (vi) Complaint register & complaints slips shlal be maitained by the contractor rep. After completion of complaint the rep of contractor shall obtained feedback and signature of user. Payment against these items shall be made after due verification of complaint register & complaint slips by JE & Engineer-in-Charge. (vii) Minimum three sets of all T&P items like aluminium folding ladders with self support, drill machine with bits of all size and other T&P as required at site, shall be provided by the contractor without any extra cost to department at the tme of commencement of work. Failing which, apenalty of Rs 500.00 per day shall be imposed and recovered from contractor dues. Tool Bags required for attending the complaint shall also be provided by contractor to the tradesmen with dress code etc. without any extra cost to Govt.
(viii) All Electrician / pipe fitter / plumber shall wear proper uniform, failing which a recovery of Rs 200/- per shift per person shall be recovered from the contractor's dues. (ix) All the stationery items like complaint register, job card, complaint book, dockets and other connected register related to the work etc shall be arranged and to the work etc shall be arranged and be maintained by the contractor with any extra cost to Govt. (x) Unserviceable retrieved material shall be property of the contractor, for which recovery shall be made from contractor's dues as per Schedule of credit attached. However the same shall be deposited by the contractor in MES yard for varification and the same shall be returned to the contractor on completion of work.
S&F in repair switch piano flush button type single pole one way 6 Amps 230 V complete all as specified and as directed
S&F in repair switch piano 6 amp SP two way 230 V complete all as specified and as directed
S&F in repair socket outlet 6 Amp 230 V flush type complete all as specified and as directed
S&F in repair bell push single pole 6 amps, 230 V complete all as specified and as directed
S&F in repair switch piano flush button type single pole 16 amps, 230V complete all as specified and as directed
S&F in repair socket piano outlet 2 in 1, 3 pin 16 amp single pole, 230 V complete all as specified and as directed
S&F in repair Modular Switch, 1 Module, 6A, AC, 240V, one way complete all as specified and as directed
S&F in repair Modular Switch, 1 Module, 16A, AC, 240V, one way complete all as specified and as directed
S&F in repair Modular Bell Push, 1 Module, 6A, AC, 240V, one way complete all as specified and as directed
S&F in repair Modular Socket, 2 Module, 6A, 2/3 pin combined, AC, 240V, one way complete all as specified and as directed
S&F in repair Modular Socket, 2 Module, 6A / 16A, 2/3 pin combined, AC, 240V, one way complete all as specified and as directed
S&F in repair Modular white cover plate with frame, 1 Module complete all as specified and as directed
S&F in repair Modular white cover plate with frame, 2 Module complete all as specified and as directed
S&F in repair Modular white cover plate with frame, 3 Module complete all as specified and as directed
S&F in repair Modular white cover plate with frame, 4 Module complete all as specified and as directed
S&F in repair Modular white cover plate with frame, 6 Module complete all as specified and as directed
S&F in repair Modular white cover plate with frame, 8 Module complete all as specified and as directed
S&F in repair Modular metal flush box, 1/2 Module complete all as specified and as directed
S&F in repair Modular metal flush box, 3 Module complete all as specified and as directed
S&F in repair Modular metal flush box, 4 Module complete all as specified and as directed
S&F in repair Modular metal flush box, 6/8 Module complete all as specified and as directed
S&F in repair ceiling rose, surface type with three terminals complete all as specified and as directed
S&F in repair Electric bell Ding-dong AC 230 Volt electric complete all as specified and as directed
S&F in repair PVC insulated body angle/Straight lamp holder with back plate complete all as specified and as directed
S&F in repair decorative LED Tube rod 1 x 20 Watt with opai diffuser, environmental friendly energy efficient suitable for Ms batten with retrofit T8 polycarbonate one end connection, complete with all accessories and fixing material complete all as specified and as directed
S&F in repair LED type light fitting 9/10 watt surface mounted with extruded polycarbonate, integrated lamp & drive, with opal diffuser and decorative end plates complete with accessories complete all as specified and as directed
S&F in repair LED bulk head light fitting wall mounted with inbuilt edge lit LED 9/10 watt, complete with all accessories complete all as specified and as directed
S&F in repair round surface/ recess mounted panel light 10 watts with aluminium housing and frosted cover complete all as specified and as directed
S&F in repair decorative wall light fixture made up of polycarbonate suitable for retrofit LED 9/10 watts lamp including all accessories for fixing of fitting on wall complete all as specified and as directed
S&F in repair 15 W LED Bulb high energy efficiency LED luminaries to be fitted on existing holders 240 V, 50 Hz complete all as specified and as directed
S&F in repair 5 Watts LED Bulb high energy efficiency led luminaries to be fitted on existing holders 240 V, 50 Hz complete all as specified and as directed
S&F in repair Isolator DP 40 amps 240 volts 10KA 50 Hz 'B' curve complete all as specified and as directed
S&F in repair MCB SP 6-32 AMPS 240 VOLTS 10ka 50 Hz 'B' curve complete all as specified and as directed
S&F in repair Isolator DP 63 amps 240 volts 10 KA 50HZ 'B' cure complete all as specified and as directed
S&F in repair Isolator TPN ,4P, 63A, AC, 415V, complete all as specified and as directed
S&F in repair Isolator TPN, 4P, 100A, AC, 415V, complete all as specified and as directed
S&F in repair insulation tape roll 20 mm wide 15 Mtr long complete all as specified and as directed
S&F in repair PVC Casing and Capping of size 20 to 32 mm, complete all as specified and as directed
S&F in repair hylam sheets 3mm thick including cutting for mounting of switches/socket suitable for sunken box of sizes 4'x4' complete all as specified and as directed
S&F in repair hylam sheets 3mm thick including cutting for mounting of switches/sockets suitable for sunken box of size 8'x10' complete all as specified and as directed
S&F in repair hylam sheets 3mm thick including outing for mounting of switches/sockets /suitable for sunken box of size 10'x12' complete all as specified and as directed
S&F in repair LED batten fitting for tube rod T8 retrofit type complete with side holders and pre wired one and connection type complete all as specified and as directed
S&F in repair LED security light fitting 1x35 Walt luminaries with die cast aluminium housing comprising epoxy powder coated enclosed with glass cover in frame with high power LED white lamp type of capacity 35 watt complete all as specified and as directed
Fans: Checking and attending an electrical ceiling fan/exhaust fan/ wall fan complaints received at AGE E/M-I yard /complaint cell including taking down & re-fixing back after repairs of any capacity including replacement of minor spare parts required during repairs like PVC connector, lock pin, nut-bolts, cleaning agent & flexible wire upto 1.00 mtr length complete all as specified and as directed Note: (i) Minor repair shall be carried out on spot and other major item shall be measured & paid separately. (ii) Major items replaced as "supply and fixing" under respective item of this Schedule shall not be payable under this item. (iii) Adequate tradesman / supporting manpower shall be deployed by contractor and they shall be present on all working days including Saturdays and holidays from 0930 hrs to 1800 hrs for maintenance of above mentioned work. The supervisor / site Engineer of the contrator shall be forwarded detailed instructions of concerned AGE / JE every morning for attending complaits on daily basis. The persons shall be detailed by AGE concerned every morning for attending complaints on daily basis.
(iv) The complaints received before 1300 hrs shall be attended on same day. The complaints received after 1400 hrs shall be attended on the next working day before 1300 hrs. If complaints shall be not attended asper Schedule, pendalty of Rs 200/- shall be imposed on contractor for each complaint for each day. (v) Any delay in non-completion of complaints shall immediately be communicated to AGE / JE. (vi) Complaint register & complaints slips shlal be maitained by the contractor rep. After completion of complaint the rep of contractor shall obtained feedback and signature of user. Payment against these items shall be made after due verification of complaint register & complaint slips by JE & Engineer-in-Charge. (vii) Minimum three sets of all T&P items like aluminium folding ladders with self support, drill machine with bits of all size and other T&P as required at site, shall be provided by the contractor without any extra cost to department at the tme of commencement of work. Failing which, apenalty of Rs 500.00 per day shall be imposed and recovered from contractor dues. Tool Bags required for attending the complaint shall also be provided by contractor to the tradesmen with dress code etc. without any extra cost to Govt.
(viii) All Electrician / pipe fitter / plumber shall wear proper uniform, failing which a recovery of Rs 200/- per shift per person shall be recovered from the contractor's dues. (ix) All the stationery items like complaint register, job card, complaint book, dockets and other connected register related to the work etc shall be arranged and to the work etc shall be arranged and be maintained by the contractor with any extra cost to Govt. (x) Unserviceable retrieved material shall be property of the contractor, for which recovery shall be made from contractor's dues as per Schedule of credit attached. However the same shall be deposited by the contractor in MES yard for varification and the same shall be returned to the contractor on completion of work.
S&F in repair Ceiling fan regulator electronic step switch type/socket type suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete all as specified and as directed
S&F in repair Modular Step Fan Regulator, 2 Module, 120W, AC, 240V, one way complete all as specified and as directed
S&F in repair replacement of capacitor 3.15 Mfd, 240 V complete all as specified and as directed
S&F in repair replacement of capacitor 2.5 Mfd, 240 V complete all as specified and as directed
Geyser: Attending Geyser complaints at site including checking and rectification of any electric fault. water leakage and making good in all respects including minor spare parts required during repairs like washer, nut bolts, copper wire upto 1.00 mtr length complete all as specified and as directed Note: (i) Minor repair shall be carried out on spot and other major item shall be measured & paid separately. (ii) Major items replaced as "supply and fixing" under respective item of this Schedule shall not be payable under this item. (iii) Adequate tradesman / supporting manpower shall be deployed by contractor and they shall be present on all working days including Saturdays and holidays from 0930 hrs to 1800 hrs for maintenance of above mentioned work. The supervisor / site Engineer of the contrator shall be forwarded detailed instructions of concerned AGE / JE every morning for attending complaits on daily basis. The persons shall be detailed by AGE concerned every morning for attending complaints on daily basis.
(iv) The complaints received before 1300 hrs shall be attended on same day. The complaints received after 1400 hrs shall be attended on the next working day before 1300 hrs. If complaints shall be not attended asper Schedule, pendalty of Rs 200/- shall be imposed on contractor for each complaint for each day. (v) Any delay in non-completion of complaints shall immediately be communicated to AGE / JE. (vi) Complaint register & complaints slips shlal be maitained by the contractor rep. After completion of complaint the rep of contractor shall obtained feedback and signature of user. Payment against these items shall be made after due verification of complaint register & complaint slips by JE & Engineer-in-Charge. (vii) Minimum three sets of all T&P items like aluminium folding ladders with self support, drill machine with bits of all size and other T&P as required at site, shall be provided by the contractor without any extra cost to department at the tme of commencement of work. Failing which, apenalty of Rs 500.00 per day shall be imposed and recovered from contractor dues. Tool Bags required for attending the complaint shall also be provided by contractor to the tradesmen with dress code etc. without any extra cost to Govt.
(viii) All Electrician / pipe fitter / plumber shall wear proper uniform, failing which a recovery of Rs 200/- per shift per person shall be recovered from the contractor's dues. (ix) All the stationery items like complaint register, job card, complaint book, dockets and other connected register related to the work etc shall be arranged and to the work etc shall be arranged and be maintained by the contractor with any extra cost to Govt. (x) Unserviceable retrieved material shall be property of the contractor, for which recovery shall be made from contractor's dues as per Schedule of credit attached. However the same shall be deposited by the contractor in MES yard for varification and the same shall be returned to the contractor on completion of work.
S&F in repair industrial metal clad plug top 3 pin 20 amp complete all as specified and as directed
S&F in repair industrial metal clad socket 3 pin 20 amp complete all as specified and as directed
S&F in repair plug top 16 Amps 3 pin 230 volts complete all as specified and as directed
S&F in repair single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and as directed
S&F in repair in repairs Modular Power Switch and Socket Unit with factory made poly carbonate modular box, 20A, 3Pin, AC, 240V incl 20A MCB SP and Plug Top complete all as specified and as directed
S&F in repair Wall fastener made-up of MS 10mm dia standard length with nut bolt complete all as specified and as directed
S&F in repair heating element of 1.5/2 KW any type with nut bolt washer complete as per site requirement complete all as specified and as directed.
S&F in repair thermostat for 6'/11 suitable for geysers of capacity 25/50 ltrs complete all as specified and as directed
S&F in repair Inner assembly with heat resistant rubber ring washer including nuts, bolts, clamps, suitable for 25 ltrs capacity Geyser of any type & any make complete all as specified and as directed
All as per Srl item No 59.00 here-in-before but 50 Liter complete all as specified and as directed
S&F in repair PVC connection pipe of 12mm (internal) suitable for hot/cold water 45cm long with brass nuts and rubber washers complete all as specified and as directed
K S Enterprises
M/S ABHI ASSOCIATES
A.V. ASSOCIATES
SA construction co.
NP ENTERPRISES
High Tech Metal India
NITHYA INFRATECH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .