Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.6 LAccepted-AOC | L-1 | Accepted-AOC Work Awarded to L1 bidder. | |
| 2 | Rejected-Technical 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | - | Rejected-Technical L2 Bidder. Documents of L2 bidder not scrutinized, as bid of L1 bidder found acceptable technically and financially |
Tender Value
₹4.8 L
EMD Value
₹6,000
Closing Date
15 May 2024, 9:00 amClosed
Project Engineer (EnM), Ashok
Ashok OCP, Piparwar Area Chatra, Jharkhand-829201
Repairing and reconditioning/ overhauling on site of two no pumps 1000GPM, 120M Head and 1000GPM,150mtr head Make Kirloskar Model No MLA200/225 pump under Ashok OCP, PR Area.
2024_CCL_307326_1
PO(AK)/PE(EnM)/e-NIT/24-25/02
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Ashok OCP, Piparwar Area Chatra, Jharkhand-829201
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
23 Jun 2024
30 Apr 2024
17 May 2024
1 May 2024
15 May 2024
1 May 2024
1 May 2024 - 7 May 2024
Amount
PART A. Pump 1000 GPM, 120 Mtr Head. Repairing of impeller with welding, grinding, facing, machining, turning and grooving work with copper electrode etc
Fitting of stage impeller(Provided departmentally)
Fabrication/making of neck ring and grove cutting(Gun metal)
Making and fixing diffuser bush.
Fitting distance sleeve(SS)(provided departmentally)
Fitting of shaft sleeve(DS)(Provided departmentally)
Making and fixing of shaft sleeve(NDE)(bronze)
Fitting of diffuser(Provided departmentally)
White metal filling with maching ,turning and making of oil stopper seal grove.
Making of impeller key with SS material
Bush bearing chamber repairing with CI rod
Dissembling and assembling of pupm with proper fitting(Except Sl No: 2 and %)
Repairing of shaft with welding including maching,turning,finishing,groove cutting etc.
Cleaning,painting,seal replacing,O ring replacing,cooningand test valve replacing
Repairing of balance disc with copper welding electrode including turning,facing ,machining etc.
PART B. Pump 1000 GPM, 150 Mtr Head. Repairing of shaft with with developing of metal and maching, turning,finishing,groove cutting etc. as per requirement.
Repairing of impeller with metal developing,brazing and grinding,facing,machining,turning and grooving work with copper electrode etc as as per requirement.
Fitting of impeller(Provided departmentally)
Fitting of shaft sleeve(NDS)
Making and fixing of shaft sleeve(DS)(Brass)
Making and fixing of diffuse bush
Repairing of balance disc with copper welding electrode including turning,facing ,machining etc.(Both Movable and fixed part)
Fitting of diffuser(Provided departmentally)
Repairing of diffuser
Dissembling and assembling of pump with proper fitting and alignment(except 3,4 and 8)
Repairing of main bush bearing (Both driving and non-driving end) includiing provoding of oil seal and complete in all respect.
Cleaning,painting,seal replacing,O ring replacing,and test valve replacing
Total impact of GST for the purpose of CTC
M/S S.K. ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .