| 1 | L1₹4.7 CrAccepted-AOC MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | ₹4.7 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹5.3 Cr+₹62.1 L (13.2%)Rejected-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | ₹5.3 Cr+₹62.1 L (13.2%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | Rejected-Technical | - | - | Rejected-Technical NOT ADMITTED AS NO MOU WITH OEM ON STAMP PAPER SUBMITTED. |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT ADMITTED AS NOT ENLISTED IN REQUISITE CATEGORY. |
Tender Value
₹3.5 Cr
EMD Value
₹4.3 L
Closing Date
20 Jun 2022, 6:00 pmClosed
Chief Engineer, CE Udhampur Zone
CE Udhampur Zone PIN- 900386 C/o 56 APO
PROVN OF COMPACT MODERN AND MODULAR STPs FOR MD ACCN AT AKHNOOR MIL STN UNDER GE (P) TANDA
2022_MES_519625_1
87882/E8
Open Tender
Civil Works
Lump-sum
455 days
Akhnoor
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,000
GE (P) Tanda
₹4.3 L
Yes
13 Sept 2022
23 Apr 2022
27 Jun 2022
23 Apr 2022
20 Jun 2022
6 Jun 2022
Amount
Total Amount of Sch 'A' Part - I (Building Works)
Total Amount of Sch 'A' Part - II (Site Clearance)
Total Amount of Sch 'A' Part - III (Plumbing Works)
Total Amount of Sch 'A' Part - IV (Internal Water Supply)
Total Amount of Sch 'A' Part - V (Internal Electrification)
Total Amount of Sch 'A' Part - VI (Road/ Path/ Culvert)
Total Amount of Sch 'A' Part - VII (Area Drainage)
Total Amount of Sch 'A' Part - VIII (MS Gate Works)
Total Amount of Sch 'A' Part -IX (Compound Wall)
Total Amount of Sch 'A' Part - X (Protective works )
Total Amount of Sch 'A' Part - XI (External Water Supply)
Total Amount of Sch 'A' Part - XII (External Electrification)
Total Amount of Sch 'A' Part - XIII (Open Shed for STP)
Sch 'A' Part - XIV (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Design , Supply, Installation , Commisioning and Testing of sewage treatment plant (STP) based on principle of aerobic attached growth non clogging randomly Moving Bed Bio- Reactor (MBBR) having capacity 1000 cum per day with all civil works for STP, including the following :- (a) 01 Nos of receiving chamber of RCC ( M-30). (b) 01 nos of fine bar screen chamber in RCC (M-30) construction with bar screen MS non corosive epoxy painted. (c ) 01 Nos of wet well RCC ( M-30). (d) 01 Nos of stilling chamber RCC ( M-30). (e) 01 Nos oil & grease chamber in RCC (M-30) Construction. (f) 01 Nos of equalisation tank in RCC (M-30) construction (Retention time minimum 06 Hrs) (g) 01 Nos lot of air grid of PVC/HDPE for equalisation tank. (h) 02 Nos MBBR reactor tanks in RCC (M-30) Construction with tube media, SS air grid & rise pipes. (j) 01 Nos tube settling Tank in RCC (M-30) construction with tube media. (k) 02 no (01 each for CCT and TWT) hypo solution tanks. (l) 01 Nos Chlorine contact cum filter feed tank in RCC (M-30) Construction with epoxy paint. (m) 01 Nos of Treated water Tank in RCC (M-30) Constrction (Capacity 40000 Gallon). (n) 01 Nos of sludge holding sump in RCC (M-30) construction. (o) Necessary foundation for electromechanical equipments. (p) MBBR Media, SS Grid & riser pipe for MBBR Reactor as per design 01 MLD STP. (q) 03 Nos (02 working + 01 standby) Non - Clog raw sewage feed pump, submersible type, flow 62.5 Cum/Hr, head 10M, material - Cast Iron. (r) 02 Nos metering type tank hypo dosing pump having capacity of 10 ltr/hr. (s) Suitable size of interconnecting pipe line network. (t) 02 Nos filter feed pump of suitable size for 1 MLD STP. (u) 01 No Dual Media filter with media and tank in MS bitumenous paints. (v) 02 Nos (01 working + 01 standby) raw sewage centrifugal type self priming pumps at equlization outlet having capacity of flow rate - 41.667 Cum/hr, head - 15M, material - Cast Iron.
Srl Item No 14.01 Contd) (w) 01 No Activated Carbon filter having Linear velocity - 08 m/hr, flow - 41.667 m3/hr, minimum dia - 2600 mm, minimum HOS - 1500 mm, material of construction - Mild steel bituminious painted, max allowable pressure drop - 0.5 bar & flow through bed - 15m3/m2hr. (x) 02 Nos (01 working + 01 standby) screw type sludge pump for centrifugal feed having dischage capacity of 6 Cum/hr. (y) 01 No centrifugal pump for sludge dewatering. (z) DWPE dosing system comprising of HDPE/LDPE tank agitator and dosing pump. (aa) Electrical panel for operation of STP as per OEM design. (ab) 05 Nos Air Blower (04 Nos working i.e. 02 per tank and 01 Stand by) twin lobe positive displacement type, material of construction - Cast Iron of capacity 167 Cum/hr each. (ac) 01 No multigrade sand filter (MSF) having capacity of flow rate through bed - 15m3/m2hr, minimum dia - 2000 mm, Material of HOS - 2900 mm, material of construction - Mild steel bituminious painted & Max allowable pressure drop - 0.5 bar. (ad) 02 Nos of Sewage pump of suitable capacity for MSF & ACF. (ae) 01 Set of Polyelectrolyte Dosing System 02 Nos (01 working + 01 standby) with pumps of capacity 75 LPH, dosing 0.3584 Kg/day of polymer with HDPE/LDPE dosing tank of size 0.5 M dia & 1 M SWD. (af) 02 Nos (01 working + 01 standby) filter press of capacity 48 Kg/batch, working at 05 batches in 20 hours in a day. (ag) 01 No Pressure gauges Bourdon's Tube typeGlycerin filled type for each pump & blower, Pressure sensing - By Diaphragm & 100mm dia of dial. (ah) 05 Nos level control switch to be placed 01 x each at RST, EQT, FFT, TWT & SHT. (aj) 05 Nos Air Rota meter to be placed 01 x each at EQT, FFT, NBBR-1, MBBR-2 & SHT. (ak) 01 No Auto De-sludge valve with motorised & timer operation system. (al) 01 No Electrical distribution board for STP operation of every water of pump, blower, filter press, valves etc.
Srl Item No.14.01 (Contd) (am) 01 Lot of Interconnecting piping and valve of all unit of STP. (an) 01 Lot of Interconnecting cable for all unit of STP. (ao) Lab for testing of COD/BOD and other necessary parameter and their equipments for testing. (ap) 01 no anoxic chamber in RCC M-30 design mix (aq) SS railing of grade 304 for staircase,around any opening which may remain open and footpath from one tank to another tank as per design submitted by the vender duly vetted by IIT/NIT. Non-slippery steps of stair case shall be considered. Note :- (a) This schedule is not prepriced by MES and the pre priced rate indicated as "Rs 0.00" under col 5 signifies this fact only. The contractorshould work out his price based on design data specified in the tender documents. Existing DWCPE sewage pipe shall be connected to inlet chamber. (b) Parameter for treated sewage effluent for the design of sewage treatment plant are as given below:- INPUT PARAMETER Flow : 1000 Cum/Day BOD : 155 mg/ltr COD : 352 Mg/ltr TSS : 172 mg/ltr PH : 7.78 Coliform : 106-107 counts/100ml TREATED WASTE WATER QUALITY BOD : < 10 mg/ltr COD : < 50 Mg/Ltr PH : 6.5 - 8.30 Outlet Coliform : NIL Residual chlorine : > 1.0 mg/ltr TSS : < 10 mg/ltr TN : <10 mg/ltr Phosphorus(Total) : < 1.0 mg/Ltr Peak Factor : 04 Peak hour : 03 hrs morning and 02 hrs evening.
Srl Item No.14.01 (Contd) ( c) All water retaining structure are to be designed and constructed with M-30 concrete. ( d) The specifications and the capacities of various items given in particular specification under heading " technical specification" are for indication only. If as per the tender's design, higher capacities are required, the same shall be provided without any extra cost to Govt. However minimum parameters are to be achieved as indicated above. (e) The Contractor has to give two years warranty for the sewage treatment plant from the date of completion and commisioning. (f) The contractor has to give minimum 15 year guarntee for MBBR membrane from OEM. (g) All Bus bars shall be of Copper . (h) All MS and RCC tanks shall be covered with GI wire 4mm dia size of mesh 75x75 mm chain link wire mesh/fencing. The wire mesh shall be fixed with GI nuts and bolts of suitable size to 65x65x6mm MS angle iron frame fixed over the tank well, the size of angle iron frame shall be as per size of various tanks specified. the frame shall be fixed to tank wall with suitable size of FI hold fast as directed by GE. Stainless Steel Railing shall be provided wherever it is technically required. So, as to achieve the parameters mentioned elsewhere in the tender documents from any one of the following OEMs :- (a) M/s Nitasha Constructions (b) M/s Optimus Enviropro Pvt. Ltd. (c) M/s Thermax Limited (d) M/s Sophisticated Industrial Materials Analytic (SIMA) Labs Pvt Ltd. (e) M/s Hydrotech Paryavaran (India) Pvt Ltd. (f) M/s Sombansi Enviro Engg Pvt Ltd. (SRRPL) (g) Any other OEM firm approved by E-in-C's Branch.
MCB, single pole, 6 to 32 Amp, `C' series, 10KA, 240 Volt, complete all as specified.
MCB, single pole and neutral, 6 to 32 Amp, `C' series, 10KA, 240 Volt, complete all as specified.
LED tube light 18/20/21 Watt, 4 feet with LED tube rod integrated type lP20, lumen output>95lum/w, color temp 5700-6500K, CRI>80, THD<20%, PF>0.9, operating voltage 140-270V, extruded aluminum housing in poly carbonate cover body with all accessories prewired and connecting electrically to ceiling rose, complete all as specified and directed.
LED tube light 9/10 Watt, 2 feet with LED tube rod integrated type lP20, lumen output>95lum/w, color temp 5700-6500K, CRI>80, THD<20%, PF>0.9, operating voltage 140-270V, extruded aluminum housing in poly carbonate cover body with all accessories prewired and connecting electrically to ceiling rose, complete all as specified and directed.
30 Watt, lP66 LED street light luminaries comprising of Die cast aluminium housing with weather proof gasket of lamp and driver compartment with 120 degree view angle, lumen output > 100 Lum/ watt, lumen maintenance> 70 % at 50000 hrs, color temp 5000-6500K, CRI > 70, THD < 15%, PF > 0.95 and LM 80 test compliance. The driver must be integrated APFC with short circuit protection, reverse polarity protection against 5KV high surges and comply with IEC 60598-1, IEC-61000-3-2, IEC 61547. The luminaire must have secondary optics with perfectly matched lens for better light control with and including brackets made of GI pipe of suitable dia light grade, bend to shape at an angle of 65 degree not less than 1.2mtr long with 2 Nos. of M.S clamp fabricated out of MS flat of size 50 x 6 mm on pole, including nuts, bolts, washers etc and making electrical connections with twin core twisted copper conductor flexible copper wire of suitable size from street light to junction specified and as directed.
Ceiling fan of 1200mm sweep, 5 star rated ( as per BEE recommendations), suitable to work on single phase, AC 230 volts, 50 hz supply complete with and including down rod , PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 23/0.0076 size from ceiling rose to ceiling fan and testing complete all as specified and directed.
Exhaust fan 450mm sweep with louvers, 1400 RPM, 230 volts (single phase), electrically operated 50 Hz, heavy duty metallic body complete with bolts, nuts & washers, embedded in the wall including provisioning of three core flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to Exhaust fan for connection, complete all as specified & directed.
Exhaust fan 250mm sweep, 1400 RPM, 230 volts (single phase), electrically operated 50 Hz, heavy duty plastic body complete and fixed including provisioning of three core flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to Exhaust fan for connection, complete all as specified & directed.
Supply, installation, commissioning and testing of outdoor type LT panel 3.15 mm thick floor mounted CPRI approved having four nos suitable size supporting legs of 50x6 mm angle iron and 45 cm above ground level and independent compartment for metering incoming feeder and each outgoing feeders, dust and vermin proof factory made, fabricate of CRCA sheet suitable for 3 ph, 415 volt, 50 Hz AC supply busbar chamber 400 Amp Capacity four Nos of aluminium busbar duly insulated with heat shrinkable type sleeves as per colour code, suported on porcelain based insulator common earth point at bottom with panel board at two nos earth terminals, cable glands with independent plates at bottom for each outgoing and incomming cables and complete panel board paint with powder coating in siemens grey colour all as approvied and necessary excavation for foundations for grouting in side PCC : type B-2 (1:2:4) for 15 cm legs comprising as under ( LT Panel No 1)
Supply and fixing of Street light panel, Pole mounted outdoor type cubical panel suitable for maximum load of 6KW, 440 Volts ,3 phase, 4 wire, 50 cycles per second comprising of Incoming MCB TPN , 415 V, 40 Amp -01 , Contactor TP ,415 V of rating 32 Amps - 01, Digital Timer 24 Hr - 01 No , Toggle Switch - 01 No .
LED street luminaries, 70/72 watt, powder coted pressure die case aluminium housing with weather proof gasket of lamp and driver compartment with 120 degree view angle, lumen output > 100 Lum/watt, lumen maintenance > 70% at 50000 hrs, color temp 5000-6500K, CRI > 70, THD < 15%, PF > 0.95 and LM 80 test complinace. The driver must be inteated APFC circuit protection, reverse polarity protection against 5KV high surges and comply with IEC 60598-1, IEC-61000-3-2, IEC -61547. The luminaire must have secondary optics with perfectly matched lens for better light control with specified and as directed. Make: Crompton Cat Part No.LSTP-72-CDL or technically and commercially equivalent models of Phillips/Bajaj/Wipro/GE/Syska/Surya as approved by the GE.
Supply and fixing bracket for street light made out of GI pipe 1.2 M long 40mm dia light grade bent to shape an angle of 65 degrees directed including clamps made out of 40mmx6mm flat iron for fixing bracket suitable for PCC/street poles including nuts and bolts of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as directed.
Supply and fixing of electrical connections with PVC insulated 1.5sqmm copper conductor cable (multistrand) FR (unsheathed) 3 runs ,drawing in and including PVC conduit 20mm dia for fixing bracket suitable for PCC/street poles and fixing accessories ,such as couplers ,lock nuts, saddles , pipe hooks of suitable from street light to junction specified and as directed
Supply and fixing of Diesel Engine driven Generating Set wtih AMF Panel of 200 KVA output under NTP at MSL conditions, 50 Hz at 1500 RPM, 0.8 Power Factor, 3 Phase 4 wire, AC 400/440 Volts, Complete mounted on common base plate with flexible coupling meeting with the requriements of latest BS/IS and complete with an integral acoustic enclosures with in built of central pollution control Board inclusive of two years normal spares as indicated below and control panel comprision as of the following :- (a) Prime Mover - Prime Mover shall be coolant cooled diesel engine of suitable capacity for driving alternator of capacity 200 KVA, 50 hz at 1500 RPM, 0.8 PF, 3 phase 4 wire , AC 400/440 volts under NTP at MSL conditons, complte mounted on common base plate with flexible coupling meeting the requirement with latest BS/IS specification with electric starting device with all standard fittings and suitable batteries as per manufactures specification. The Engine shall be equipped with standard fittings as per manufacuter's recommendations. (b) Engine Instruments Panel - All relevent parameters shall be conventionally displayed on panel thereby providing easy monitoring of lubricating oil, pressure, coolant, temperature, battery charging ammeter, RPM and hours meter starting switch etc. (c) Fuel Tank : Fuel tank of 12 hours capacity will be installed as per the manufacturer's requirement including all necessary connections from fuel tank to engine and overflow engine to tank and for overflow. (d) Sound Proof Canopy - The canopy shall be provided as per latest CPCB norms to reduce noise pollution . (e) Alternator : 200 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor burshless type, screen protected , revolving field, self excited, self regulated through an AVR confirming to relevant BS/IS. Engine and Alternator shall be mounted on specially designed base plate of rigid welded consturctions with anti vibraton pads. The engine and alternator shall be placed on foundation including necessary civil works as per the manufacturer's recommendations/site requriement.
14.16 Contd... (f) Control Panel : The standard microprocessor based control panel shall be fabricated out of 14 CRCA sheet and powder coated inside and outside and shall display as follows :- (i) Voltage of all three phases. (ii) Current of all three phases. (iii) Frequency. (iv) Bus bar chamber with aluminium busbar of cap 500 amps - 04 nos.. (v) C.T of suitable current rating-03 Nos make : AE/KAPPA/Electric field (vi) MCCB TPN of appropriate capacity - 01 Nos. (vii) Instrument fuses duly wired and ferruled. (g) Engine and Alternator protective functions includes - low lub oil pressure, high engine water temp warning / shutdown, low coolant temp warning, low and high battery volate warning, weak battery warning, cranking lockout, high and low AC voltage shutdown and under and over frequency shutdown/warning. Notes :- (i) Foundation for the DG set shall be as per the manufacturer's recommendations. No extra payment for same shall be given to contractor for foundation & transportation of DG set. (ii) Connections of alternator, control panel to the change over switch in LT panel with XLPE insulated armoured cable of appropriate size 110 V grade including copper tube terminals. cable will be measured separately under relevant item.
14.16 Contd... (iii) Semi rotary hand operated fuel pump for filling fuel tank from 200 ltrs barrels including all accessories shall be supplied by the contractor and the cost is deemed to be included in the quoted rate. (iv) Maintenance and operation manual, spare parts catalouge with normal maintenace tools, routine maintenance chart, shall be provided for engine and alternator by the contractor and the cost is deemed to be included in the quoated rate. (v) manufacturing schedule of the engine manufacturer :- The complete generator set including control panel, base frame, coupling shall be from engine manufacturer workshop incise of Make M/S Greaves Cotton and Mahindra and mahindra. But in case of make M/S Kirloskar at one of theri twelve authorized GOEMs for looking after this region, the same shall be assembled by M/S Sudhir Gen Set,s their auth GOEMs for this regions. The contractor will produce certificate from engine manufacturer/auth GOEMs that complete generator set has been assembled/tested at engine manufacturers/GOEMs workshop (vi) List of normal spares :- Contractor shall supply following normal spares for two years. Cost of spares is deemed to be included in the quoted rate (a) Fuel filters complete set - 02 sets, (b) Oil filters - 02 sets, (c) Fan Belts - 02 Sets (vii) Precommissioning test shall be carried out by rep of Accepting officer within overall cost quoted by the contractor. All testing arrangement without POL shall be made by the contractor.
Cutting into existing bituminous carpet road/PCC hard standing upto a depth of 30cm for laying of UG cable/GI pipe and making good the disturbed surfaces to match with the existing
Supply and fix junction box water proof outdoor type made out of SMC sintex make of exterenal dimensions 250 x 250 x 105 mm single door type hinged with locking arrangement front operated with one number MCB 06 Amps capacity for housing 3 phase and neutral busbar including connecting the incoming/outgoing cables including cable glands SMC coated clamps bolts etc all as directed and fixed to the existing poles with mild steel flat of size 25 mm x 4 mm Make - Sintex Cat GSJB 2520 or equivalent.
M & L for construction of brick masonary platform 3x2.5x1.2 mtr for transformer with XPM fencing with weight not less than 4kgs/Sqm and angle iron 50x50.x6 mm for suport gate with locking arrangement PCC floor including excavation and earth work, platform white washing, Painting of fencing and frame work as per CEUZ Drg No. 1033/90 complete all as specified and directed.
Supply and fixing Ductile iron pipes as per IS 8329(2000) of 80 mm dia K-9 , both end flanged complete with nuts ,bolts, washers and rubber fibre board gasket joint in any length, laid in trenches or under roads etc as directed by Engr in Charge.
Supply and fixing Ductile iron pipes as per IS 8329(2000) of 100 mm dia K-9 , both end flanged complete with nuts ,bolts, washers and rubber fibre board gasket joint in any length, laid in trenches or under roads etc as directed by Engr in Charge.
Supply and fixing Ductile iron pipes as per IS 8329(2000) of 150 mm dia K-9 , both end flanged complete with nuts ,bolts, washers and rubber fibre board gasket joint in any length, laid in trenches or under roads etc as directed by Engr in Charge.
Supply and fix CI Air valves with single air outlets confirming to IS 14845 of size 50 mm dia bore and fixing up in CI water supply main of size 80 mm dia
Construction of valve pit of size 120x120x120 cm (internal dimension) including necessary excavation earth work in any soil, including 150 mm thick PCC 1:4:8 type D-2 of size 186x186 cm as foundations, 230mm thick brick wall in CM 1:6, internal plastering 15mm thick in CM 1:4 ,50 mm thick PCC 1:2:4 type B-1 in coping MS cover including welding & fabricated out of 3 mm thick MS sheet fixed on MS frame angle iron 40x40x6 mm thick with 4 Nos hod fast made out of flat iron 30x3mmx300mm long with hinges and locking arrangement and painting MS work with two coats of synthetic enamel paint over red oxide complete all as specified and directed
Construction of valve pit of size 90x90x90 cm (internal dimension) including necessary excavation earth work in any soil, including 150 mm thick PCC 1:4:8 type D-2 of size 186x186 cm as foundations, 230mm thick brick wall in CM 1:6, internal plastering 15mm thick in CM 1:4 ,50 mm thick PCC 1:2:4 type B-1 in coping MS cover including welding & fabricated out of 3 mm thick MS sheet fixed on MS frame angle iron 40x40x6 mm thick with 4 Nos hod fast made out of flat iron 30x3mmx300mm long with hinges and locking arrangement and painting MS work with two coats of synthetic enamel paint over red oxide complete all as specified and directed
Supply installation testing and comissioning of pumping set Centrifugal driven single stage, 3 phase, 415 volts,50 HP, discharge range from 1450 LPM, speed 1440 rpm, head 80 Mtr complete inclusive of three phase star-delta starter including cable for making connections between panel to motor and PCC 1:4:8 in foundation as directed by manufacturer/Engr-in-charge.
Cutting into existing bituminous carpet road/PCC hard standing upto a depth of 30cm for laying of UG cable/GI pipe and making good the disturbed surfaces to match with the existing
M&L for making arrangements for stand posts for reused pipe extracted from STP with 0.60 cm height from ground with using 20mm dia GI medium grade pipe alongwith PVC bib tap 20 mm dia including painting complete stand post with red colour synthetic enamel paint and warning to be issued on metal plate of size 300x150x4mm in both Hindi & English displaying water not fit for drinking, complete all as specifid and directed.
Outsourcing of manning and operation of Sewage Treament Plant in (02) two shifts per day of 08 hours each (1st shift starting from 0600 to 1400 hours, 2nd shift from 14000 to 2200 hours) by deploying one experienced skilled operator for each shift during the defect liability of original contract STP. The operator to be present daily, scope of work will be described in notes given below, complete all as specified and directed. Notes : Contractor shall get th water tested from any Govt approved lab on quarterly basis and report thereof be submitted to GE (N) Akhnoor
Comprehensive repair/ maintenance and outsourcing of manning and operation of Sewage Treatment Plant in (02) two shifts per day of 08 hours each (1st shift starting from 0600 to 1400 hours, 2nd shift from 14000 to 2200 hours) by deploying one experienced skilled operator for each shift. The operator to be present daily, scope of work will be described in notes given below, complete all as specified and directed. Quoted rate shall include the aspect mentioned below. Scope of Work (i) Stacking the sludge properly (ii) Cleaning the blockages in any pumps/ pipe lines (iii) Supplying/ distributing the treated water regularly as per the directions (iv) Complete cleaning of grits and channels daily (v) Brooms and cleaning materials will be arragned by the contractor. (vi) During the cleaning safety equipments will be supplied and arranged by the Contractor. (vii) Removing the algae/ sludge in the tube steller and keeping the surrounding area clean. (viii) Mixing of chemicals as directed. (ix) Daily, weekly, monthly, quarterly, half yearly and yearly maintenance of equipments (x) All consumable chemical required for STP shall be provided by the contractor. (xi) Fuel and lubricant for running of DG set shall be provided by the Deptt.
Srl No. 14.32 Contd.... Notes :- (a) Cost of spare parts, which shall be replace/ repair during operation deemed to be included in rate quoted by contractor and no extra shall be measured and paid in replacement/ repair in respective items. (b) Contractor shall get the water tested from any Govt approved lab on quarterly basis and report thereof be submitted to GE (N) Akhnoor
Dee Ess Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .