| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC NOT SPECIFIED | ₹10.6 L Quoted ₹11.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹12.6 LRejected-Finance GSTIN: 09ABSFA3195K1ZR25 SHIV SAROVER COLONY GARH ROAD MEERUT 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹12.6 L | L2 | Rejected-Finance 2nd lowest |
| 3 | L3₹12.8 LRejected-Finance PLOT NO 46 SECTOR PH I 03 GREATER NOIDA UP 201306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201306 | ₹12.8 L | L3 | Rejected-Finance 3rd lowest |
| 4 | L4₹13.0 LRejected-Finance GSTIN: 09AJKPG7293CIZI34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹13.0 L | L4 | Rejected-Finance 4th lowest |
| 5 | L5₹13.2 LRejected-Finance GSTIN: 07AHBPP9135F1ZB | ₹13.2 L | L5 | Rejected-Finance 5th lowest |
| Sl No | Description | Qty | Unit | Madan Lal Jain and Sons L6 | SANJEEV ENGINEERS AND CONTRACTORS L7 | Manglam Engineers and Construction Co L4 | A.V. ASSOCIATES L2 | S.P CONSTRUCTION CO. L5 | ATHARV CONSTRUCTION L1 | Shri Kanchan Engineers L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed. | 90 | Sqm | 20 ₹1,800 | 100 ₹9,000 | 25 ₹2,250 | 50 ₹4,500 | 100 ₹9,000 | 50 ₹4,500 | 22 ₹1,980 |
| 2.00 | M & L for nominal mix concretes 1:2:4 type B-O(using 12.5 mm graded stone aggregates) as in padding on roof finished even and fair without using extra cement all as specified and directed. | 4.5 | Cum | 4,000 ₹18,000 | 7,000 ₹31,500 | 4,990 ₹22,455 | 4,500 ₹20,250 | 6,000 ₹27,000 | 3,800 ₹17,100 | 7,000 ₹31,500 |
| 3.00 | Supplying and laying APP based modified water proofing polymeric membrane reinforced with non woven polyester fabric matt (weight not less than 150 gram/sqm) of minimum 3mm thick, weight not less than 3 Kg/sqm, laid over & including 15 mm thick rendering in cement mortar 1:4 on concrete surfaces, finished the surfaces even and smooth including mixing of water proofing compound @ 3% by weight of cement over a bituminous shalitex primer @ 0.30 Kg/sqm evenly over a coat of hot bitumen 85/25 @ 1.2 Kg/sqm. The membrane shall be unrolled and bonded completely to the substrate (with overlap of 100mm on the transverse direction and 75mm on longitudinal direction and sealed by thermos fused torch) and the overlaps sealed / fused by thermos fused torch as per manufacturer instructions. A coat of non reflective bituminous aluminium paint @ 0.150 Kg/ Sqm, complete all as specified and as directed
Note :- Water proofing compound shall be measured & paid separately under respective items of BOQ | 90 | Sqm | 550 ₹49,500 | 650 ₹58,500 | 369 ₹33,210 | 490 ₹44,100 | 370 ₹33,300 | 400 ₹36,000 | 500 ₹45,000 |
| 4.00 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified & directed. | 14 | Cum | 200 ₹2,800 | 300 ₹4,200 | 250 ₹3,500 | 500 ₹7,000 | 450 ₹6,300 | 300 ₹4,200 | 200 ₹2,800 |
| 5.00 | M&L brick work with old size fly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as specified & directed. | 10 | Cum | 6,000 ₹60,000 | 6,000 ₹60,000 | 5,490 ₹54,900 | 6,000 ₹60,000 | 6,000 ₹60,000 | 6,000 ₹60,000 | 7,000 ₹70,000 |
| 6.00 | M&L old size brick work with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks Complete all as specified and directed. | 4 | Cum | 5,000 ₹20,000 | 5,600 ₹22,400 | 2,890 ₹11,560 | 2,800 ₹11,200 | 2,500 ₹10,000 | 2,000 ₹8,000 | 3,500 ₹14,000 |
| 7.00 | Dismantling mild steel or wrought iron work in roof trusses,gratings etc and similar work complete all as specified & directed | 4 | Qtl | 10 ₹40 | 1,000 ₹4,000 | 150 ₹600 | 1,000 ₹4,000 | 450 ₹1,800 | 500 ₹2,000 | 23 ₹92 |
| 8.00 | M&L for mild steel work in roof trusses,purlins,rafters,wind ties,crane gantries,posts,rails and fastenings and heavy bracket framing (Beam,Tee,Angle,Channel or Flat sections) including distance pieces,cleats etc complete all as specified and directed. | 400 | Kg | 120 ₹48,000 | 125 ₹50,000 | 95 ₹38,000 | 110 ₹44,000 | 120 ₹48,000 | 88 ₹35,200 | 111 ₹44,400 |
| 9.00 | Dismantaling asbestos cement sheets(corrugated, semicorrugatd) in roof coverings complete all as specified and directed. | 75 | Sqm | 20 ₹1,500 | 75 ₹5,625 | 15 ₹1,125 | 20 ₹1,500 | 50 ₹3,750 | 20 ₹1,500 | 23 ₹1,725 |
| 10.00 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. | 70 | Sqm | 730 ₹51,100 | 750 ₹52,500 | 675 ₹47,250 | 700 ₹49,000 | 700 ₹49,000 | 600 ₹42,000 | 700 ₹49,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹32,400
Closing Date
14 Feb 2026, 6:00 pmClosed
GE (North) Meerut Cantt
GE (North) Meerut Cantt
SPECIAL REPAIR TO BLDG NO DS-33 (JCOs LIVING) OF 92 MED REGT AT SRC LINE UNDER AGE B/R-I AND AGE E/M-I OF GE (NORTH) MEERUT CANTT
2026_MES_749014_1
8624/E8
Open Tender
Civil Works
120 days
Meerut
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (North) Meerut Cantt
₹32,400
Yes
29 Apr 2026
17 Jan 2026
21 Feb 2026
17 Jan 2026
14 Feb 2026
31 Jan 2026
Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed.
M & L for nominal mix concretes 1:2:4 type B-O(using 12.5 mm graded stone aggregates) as in padding on roof finished even and fair without using extra cement all as specified and directed.
Supplying and laying APP based modified water proofing polymeric membrane reinforced with non woven polyester fabric matt (weight not less than 150 gram/sqm) of minimum 3mm thick, weight not less than 3 Kg/sqm, laid over & including 15 mm thick rendering in cement mortar 1:4 on concrete surfaces, finished the surfaces even and smooth including mixing of water proofing compound @ 3% by weight of cement over a bituminous shalitex primer @ 0.30 Kg/sqm evenly over a coat of hot bitumen 85/25 @ 1.2 Kg/sqm. The membrane shall be unrolled and bonded completely to the substrate (with overlap of 100mm on the transverse direction and 75mm on longitudinal direction and sealed by thermos fused torch) and the overlaps sealed / fused by thermos fused torch as per manufacturer instructions. A coat of non reflective bituminous aluminium paint @ 0.150 Kg/ Sqm, complete all as specified and as directed Note :- Water proofing compound shall be measured & paid separately under respective items of BOQ
Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified & directed.
M&L brick work with old size fly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as specified & directed.
M&L old size brick work with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks Complete all as specified and directed.
Dismantling mild steel or wrought iron work in roof trusses,gratings etc and similar work complete all as specified & directed
M&L for mild steel work in roof trusses,purlins,rafters,wind ties,crane gantries,posts,rails and fastenings and heavy bracket framing (Beam,Tee,Angle,Channel or Flat sections) including distance pieces,cleats etc complete all as specified and directed.
Dismantaling asbestos cement sheets(corrugated, semicorrugatd) in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed.
S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer, complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m Complete all as specified and directed.
M & L for applying 15 mm thick rendering using ready mix plaster bags in CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately
Supply only integral water proofing compound complete all as specified & directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed.
M & L for 15 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
M&L for 2 mm thick applying a layer of JK/ Birla putty on wall surfaces including cornics etc for proper levelling of plaster complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished even and smooth in ceiling without using extra cement complete all as specified & directed.
M&L for preparing newly plastered ceiling surfaces and applying three coat of white wash on undecorated surface complete all as specified and directed.
M&L for complete removal of existing treatment , plastered or un-plastered surfaces of walls and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed.
M&L for complete removal of existing treatment , plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper white or tinted over a coat of primer complete all as specified and directed.
M&L for preparing old decorated surfaces of ceiling and applying two coats of white wash complete all as specified & directed.
M & L for old painted surface to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coats of synthetic enamel including preparation of surfaces complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed.
M&L for 25 mm thick Cement concrete type-B-0 1:2:4 (12.5 MM graded aggregate) as subbase in floorscomplete all as specified and directed
S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm screed bed in CM 1:6 complete all as specified and directed.
S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 10mm thick rendering in CM 1:4 complete all as specified and directed.
M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles, laid over screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes Complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M & L for glazed ceramic coloured / printed tiles 450mm x 300mmX7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles,over rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting & vertical Tiles complete all as specified and as directed.
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed .
M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each complete all as specifed & directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.0 Sqm each complete all as specifed & directed.
S & F 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid Moulded WPC door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S & F 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Rates inclusive of M.S. hold fast/ lugs or SS dash fasteners). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed.
S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Rates inclusive of M.S. hold fast/ lugs or SS dash fasteners). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed.
S&F powder coated anodised aluminium ventilators side hung openable type with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) incl stainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, including S&F 5.50 mm thick black glass complete all as specified and directed.
S&F powder coated anodised aluminium windows sliding type (3 shutter type) with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) incl stainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, aluminium grill with one or more rebates including S&F 5.50 mm thick black glass complete all as specified and directed.
S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 100mm complete all as specified and directed.
S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section
S & F floor door stopper of chromium plated body with rubber shoe fixed in door, overall length of cover plate 140 mm complete all as specified & directed
S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples complete all as specified & directed
S&F in repairs 20mm Dia Aluminium alloy anodised curtain rod decorative fancy type with brackets complete all as specified & directed.
M&L for Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-410-O or Fe-310-O, complete all as specified & directed
S&F in repairs stop valves, cast copper alloy, fancy type chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified & directed.
S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified & directed
S & F in repairs bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified & directed
S & F in repairs vitreous china wash basin, white flat back size 550X400 mm, (flat back or angle back type) including brackets and including cutting for and pinning in ends of brackets or erecting stand complete all as specified & directed.
S&F in repairs 15 mm dia brass chromium plated Central Hole Basin Mixer with Regular Spout with Popup Waste System with 450mm Long Braided Hoses fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstan head screwed for 15mm dia pipe fixed complete all as specified & directed
S&F in repairs Corner Glass Shelf (with Bracket) complete all as specified & directed..
S&F in repairs fancy type 600mmx450mm bevelled edge looking mirror and fixed to wooden plug with CP brass screws and cup washers complete all as apecified & directed
S&F in repair 75mm dia Cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed.
S&F chromium plated Soap dish fixed to plug with chormium plated brass screws complete all as specified & directed
S&F in repairs PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends complete all as specified & directed.
Dismatling PVC Water tank Exc 250 & n exc 500 ltr and removing from site as specified and directed
S & F Rotational moulded PVC water storage tanks 500 Ltrs capcity three layer (cylindrical vertical with closed top) hoissted and fixed in position complete all as specified & directed
S & F Ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches and wall complete all as specified and directed.
M & L for hard core of gauge not exc. 63mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed.
M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement to match the surace of tiles in foor/steps, over 15 mm thick screed bed or bedding layer in CM 1:6 complete as all specified and directed.
M&L for providing cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in copings,platform,kerbs etc including weathering, slightly rounded or chamfered angles and throating as directed by Engineer-in-charge
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed.
Surface channel in concrete 1:3:6 (40 mm graded aggregate) for drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed.concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc all as specified and directed.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make complete all as specified. Note: WPC shall be measured & paid separately.
M&L for RCC work type B-1 1:2:4 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, in shelves and precast cover slabs on manholes complete all as specified & directed.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Formwork to rough finished surface of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Removing excavated soil exceeding 250 m but not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified & directed
Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified & directed.
Demolition and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortar all as specified
M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed.
M&L for Cement concrete 1:2:4 in haunching and benching for manholes complete all as specified and directed
Taking down carefully any type of battens or conduit point wiring with conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site to match the existing complete all as specified & directed
M&L for concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FR-LSH, conforming to IS: 694-1990, PVC insulated, unsheathed copper conductor and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal box suitable for fixing moduler switches, sockets, regulator etc including modular inner frame and outer plate cover with continuous green earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated multi stranded, FRLS copper conductor cable, unsheathed and connected to common earth and earth dolly including cutting holes in or through the walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as specified and directed for One light point wiring controlled by one, one way switch/bell push button. The point wiring shall include the wiring of light/ outlets of any length from the distribution board via switch to the point.
All as described ser item no 89.00 here-in-before but one fan point control by one 1- way switch
All as described ser item no 89.00 here-in-before but exhaust fan point control by one 1- way switch
All as described ser item no 89.00 here-in-before but security light point control by one 1- way switch
All as described ser item no 89.00 here-in-before but one out let socket point 3pin 5 amps on independent board.
All as described ser item no 89.00 here-in-before but on the same board with other switches
All as described ser item no 89.00 here-in-before but using 2.5 sqmm copper conductor with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed.
S&F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and as specified.
S&F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked wirh indicator and as specified.
S&F 1 module modular blank plate complete all as specified and directed.
M&L lamp holder (Angular / Straight), insulated body, with back plate all as specified and directed.
M&L of ceiling rose, 2 phase/PVC/polycarbonate isolated body complete all as specified & directed complete all as specified & directed
S&F 15 watt LED bulb 2 pin B22 base,100 Lumems per watt,PF≥0.9, voltage surge protection complete all as specified & directed
S&F wall mounted LED tube light fitting 20 watt with polycarbonate housing with all accessories and fixing material complete all as specified and directed.
S&F 35W LED building security light energy saving & environmental friendly long life luminaire with high power LEDs as light source and electronic driver including all material required for fitting all as specified and directed
S&F of sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated FR-LSH, unsheathed, copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, single core, PVC insulated FR-LSH, unsheathed,copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing incl taking down old u/s submain wiring complete all as specified & directed.
S&F sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces incl taking down old u/s DB's complete all as specified & directed
S&F sheet metal enclosure double door, tripple pole and neutral, AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces incl taking down old u/s DB's complete all as specified & directed
S&F MCB, SP, AC, 240 volts "C" series capacity of 06 to 32Amps, 10kA and making connections complete all as specified & directed.
S&F MCB SPN 40 A, AC, 240V, 10KA, ISI Marked 'C' curve incl thimble etc complete all as specified and directed.
S&F Isolator TPN, 63A, AC, 415V, ISI/CE Marked complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
S&F Exhaust fan with louver Steel and fixing accessories 230 Volt and 250 mm sweep mounted on aluminium frame all as specified and as directed.
S&F BLDC ceiling fan 1200mm sweep with fan regulator, 210CFM air delivery 6.00, BEE 5 star energy rated minimum service value≥6,copper winded motor ,anti rust powder coated aluminium blade,double ball bearing, dynamically balanced including canopy,down rod as per site rqmt ,shackel assembly,safety pin,nut bolt etc electrical connection with flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete incl writing MES No. complete all as specified & directed
S & F electric water heater, storage type glassline coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes,hanging assembly etc connecting with 3 core flexible Cu conductor cable of appropriate size from power point to the geyser including plug top,writing MES No complete all as specified and directed
Supply ,laying commissioning ,testing of XLPE under ground LT cable 1100 volts grade of size 25 sqmm 4 core armoured PVC sheathed with aluminium conductor heavy duty laid in trench ,fixing on wall ,under road crossing through proctection pipe etc including taking down old LT UG cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out including foming of bottom surface for laying of cable / pipe etc in soft/loose soil complete all as specified and directed
Removing surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exc 1.5M above the starting point complete all as specified and directed
M&L for sand cushioning, spreading & levelling, watering and well ramming in layers not exec 25cm in soft/loose soil complete all as specified and directed
Supplying & laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and directed.
GI light grade tubing 40mm dia laid in trenches, road crossing , pasing through pipe or laid in wall/pole complete all as specified and directed
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
8624TD.pdf
Tender Documents • 1.97 MB
BOQ_838814.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid