Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr | L1 | Accepted-AOC ACCEPTED BEING LOWEST AND QUOTED AMOUNT FOUND REASONABLE. |
| 2 | L2₹2.4 Cr+₹3.2 L (1.33%)Rejected-Finance 3 333 F M P ARCS VENGACHUVADU VAZHAKKULAM P O CHAITHANYA BUILDING SA ROAD KADAVATHRA MUVATTUPUZHA ERNAKULAM 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | ₹2.4 Cr+₹3.2 L (1.33%) | L2 | Rejected-Finance Rejected being not lowest. |
| 3 | L3₹2.7 Cr+₹30.0 L (12.5%)Rejected-Finance CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | ₹2.7 Cr+₹30.0 L (12.5%) | L3 | Rejected-Finance Rejected being not lowest. |
| 4 | Rejected-Technical | - | - | Rejected-Technical The bidder has not submitted EMD alongwith Cover 1. DD against EMD submtted later is drawn on 09 Dec 20 after the bid submission end date of 07 Dec 20. Working capital certificate not submitted. Solvency certificate submitted for less amount. |
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
7 Dec 2020, 6:00 pmClosed
CHIEF ENGINEER NAVAL WORKS KOCHI
CE NW KOCHI MILITARY ENGINEER SERVICES KATARIBAGH NAVAL BASE POST KOCHI 682 004
PROVN OF 11 KV 500 KVA COMPACT SUBSTATION ALONG WITH ALLIED WORKS FOR NCN PROJECTS AT INS DWEEPRAKSHAK KAVARATTI
2020_MES_381189_2
890967
Open Tender
Civil Works
Lump-sum
450 days
KAVARATTI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
Yes
GE NAVY LAKSHADWEEP
₹3.6 L
Yes
4 Feb 2021
18 Nov 2020
9 Dec 2020
18 Nov 2020
7 Dec 2020
23 Nov 2020
Amount
Total amount of Sch 'A' part-I ( Building Works)
Total amount of Sch 'A' part-II (Excavation & earthwork)
Total amount of Sch 'A' part-III (Internal Water Supply)
Total amount of Sch 'A' part-IV (Internal Electric Supply)
Total amount of Sch 'A' part-V ( External Electric Supply)
Total amount of Sch 'A' part-VI (Sewage Disposal)
Total amount of Sch 'A' part-VII (Road/ hardstanding/ Path)
Total amount of Sch 'A' part-VIII (Compound wall/ Retaining wall)
SCH. 'A' PART - IX (MISCELLANEOUS ITEMS) Note :- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Internal Water Supply:- Angular stop cock, chromium plated, cast copper alloy, screwed down, screwed for CPVC pipe 15/16 mm bore Make Jaquar code No CON-059KN or equivalent of other make specified in the list of manufacturer complete all as specified
Concealed stop cock, long body chromium plated, cast copper alloy, screwed down, screwed for CPVC pipe 15/16mm dia bore of Make Jaquar code No CON-069KN or equivalent of other makes specified in the list of manufacturers complete all as specified
Health Faucet Make jaquar Cat Part No. ALD-579 or equivalent of other make specified in the list of manufacturer with 1.0 Mtr flexible tube 16mm dia (outer), low density polythene, suitable for cold water application complete with union and teflone washers and holder to suit 15mm angle cocks complete all as specified
Cutting existing CPVC pipe 40 mm dia and inserting bend complete all as specified
INTERNAL ELECTRIFICATION :- Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. with and including heavy duty non metalic regid PVC concealed conduit medium duty and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with galvanised modular mild steel/pressed steel sunken boxes (with earth dolly) duly electroplated, covered with modular frame and base plate for fixing of modular switches, sockets and fan regulators etc, including one run of PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- (NOTE: (i) Switches, sockets, regulators to be measured and paid for separately.
(a) All as per item No. 14 here-in-before but for One light point controlled by one 5/6 amps one way switch complete all as specified
(b) All as per item No. 14 here-in-before but for One ceiling fan/exhaust point controlled by one 5/6 amps one way switch complete all as specified
(c) All as per item No. 14 here-in-before but for One Socket outlet, three pin, 5 /6 Amp, independent controlled by one 5/6 amps one way switch complete all as specified
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. with and including heavy duty non metalic regid PVC concealed conduit medium duty and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with galvanised modular mild steel/pressed steel sunken boxes (with earth dolly) duly electroplated, covered with modular frame and base plate for fixing of modular switches and sockets etc, including on run of PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 15/16 amps socket outlet independent board:- (NOTE: Switch and socket to be measured and paid for separately)
Submain wiring with 2 runs of 2.5 Sqmm PVC insulated unsheathed copper conductor multistranded FRLS cable drawn in and including PVC rigid non metallic conduit and its accessories laid in concealed in wall/roof/floor etc including one run of 2.5 Sqmm multi stranded copper conductor cable for earth continuity wire with junction box covered with laminated sheet 3mm thick and other accessories complete all as specified and as directed. (Note: Three runs of 2.5 sqmm wire and one run of PVC rigid non metallic concealed conduit shall be measured as one run only
Earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix) cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.03 of SSR Part-I(2009), connecting to earthing test point all as specified including testing on completion.
Decorative Ultra slim linear 20W, 4 feet LED lighting fixture with extruded aluminium heat sink, environmental friendly, energy efficient prewird with lamp, AC, 230V, ISI marked. Make : Havells model No. LHEXBHP7PN1W020 or equivalent of Crompton Greaves / Philips complete all as specified
Decorative Ultra slim linear 10 W, 2 feet LED lighting fixture with extruded Aluminium heat sink, environmental friendly, energy efficient prewird with lamp, AC, 230V, ISI marked. Make : Havells model No. LHEXBHP7PN1W010 or equivalent of Crompton Greaves / Philips complete all as specified
Energy saving new generation long life ersalite pressure die cast aluminium IP 66 luminaire (security light) with high power LED 45W, 5000K Make Havells Model No.LHETAXU7PN6J045 or equivalent in Phillips/Bajaj complete with GI bracket of suitable dia and length 1.0 Mtr fixed to wall with suitable MS clamps and single core multistranded copper conductor cable of 1.5 Sq mm from ceiling rose/connector to fitting complete all as specified
MCB SP 6 to 32 A, AC, 230V, 10KA. complete all as specified
MCB SPN 20 to 32 A, AC, 230V, 10KA. complete all as specified
Ceiling fan, copper wound having service value > 4.5 as per IS 374.2019 (2 star) complete with down rod, canopy, mounting clamp etc. AC, 230V, 1200mm Sweep without regulator including 1.50 Sqmm 3 core flexible Copper cable from fan connector to ceiling rose complete all as specified .
Exhaust fan, Copper wound, PVC / Polycarbonate body and louvers complete AC, 230V, 250mm Sweep connect to ceiling rose complete all as specified
EXTERNAL ELECTRIC SUPPLY : Supply and Installation of 11 KV Compact Sub Station with non extensible RMU consisting of following :- A . HT SWITCHGEAR 11kV, 630Amps, 21KA for 3 Sec. Non-Extensible Ring Main Unit with Metering Panel Compact Switchgear Consisting of One No. Vacuum Circuit Breaker In SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection, earth fault protection and thermal over load relay for transformer. Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm aluminium unarmorured XLPE Cable . B. TRANSFORMER 500 KVA, 11KV/415V DYn11 DRY Transformer type of design with Off load tap switch of rating +5% to -10% @2.5%. (IS Tol.2026) and WTI (Winding temparature Indicator), copper wound complete all as specified. C. LOW VOLTAGE SWITCHGEAR-1600 A COPPER BUS BAR LT ACB (Air circuit breaker) INCOMER CUM OUTGOING 415 V , 1600Amps 4P,50 KA fixed ACB Microprocessor based release
D . OUTDOOR ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel of thickness not less than 2mm. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for Transformer compartment. The enclosure exterior shall be powder coated (colour Light Grey & D.A.Grey). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. E. INTERCONNECTION AND EARTHING Interconnection between HT switchgear & Transformer using 1Cx3x95Sq.mm XLPE Single core cable & Interconnection between Transformer & LT switchgear using aluminium Busbars. Internal earthing connections by using 50x6 mm Copper Strips.
Note:- (a) Packge Sub-Station is indoor plinth mounted type. Rate quoted shall be inclusive of errection, testing and commissioning including Civil worka for package substation as per OEM specifications (b) Package Sub-staion complete with the internal interconnections & all other miscellaneous items required for satisfactory completion of job shall deemed to be included in the rate quoted.
Supply , install, commissioning and testing of three phase, 50 Hz indoor type oil cooled Servo Voltage Stabilizer of capacity 500 KVA microprocessor based technology for automatic operation, manually oil cooled, copper wound and designed for following specifications :- (a) Input variation between 340V to 480V. (b) Output voltage stablilized at 415V with accuracy + 1%. (c) Rate of correction 70V Per Sec. (d) Response time less than 10 millisecond. (e) Insulation Resistance (IR) more than 500 Mega Ohms on 500V DC. (f) Breakdown strength 2500KA for 2 Min. (g) Efficiency 98%. (h) Digital volt and ammeters. (j) Connection Delta/ Star protections circuit includes electronic over voltage trip, electronic under voltage trip, overload and short circuit protection single phasing prevention & cut off phase reversal protection & cut off metering LCD type input voltae P-N output voltage P-P load current in all phases frequency.
Supply , install, commissioning and testing of three phase four wire ,indoor type oil cooled Ultra Isolation Transformer of capacity 500 KVA , 50 Hz microprocessor based technology, naturally oil cooled, copper wound & designed for following specifications :- (i) Ratio 1:1 (ii) Regulation Better than 3.5% (iii) Efficiency 98 % (iv) Power Factor 0.8 Lead to .8 Lag (v) Di-Electric strength 3kv for 60 Sec (vi) Insulation Resistance Better than 500 Mega Ohms (vii) Coupling Capacitance 0.01pF for 100 dB (viii) Leakage Current < 20 Micro Amps (ix) Common Mode Attenuation 100 db./ 120 db. (x) Operating temperature 0˚ C - 45˚ C Ambient Protections circuit includes Electronic over voltage trip, Electronic under voltage trip, Overload and short circuit protection. Single phasing prevention & cut off Phase reversal protection & cut off Metering LCD type Input voltage P-N Output voltage p-p Load current in all phases Frequency
Design, supply, install, testing and commissioning of 11kV, 630 A, 21 kA,3 Way RMU (1. Breaker + 2. Isolator +3. Breaker ) , SF6 insulated, inside robotically welded stainless steel (non ferrite, non magnetic grade) tank having minimum thickness of 3mm with IP67 degree of protection, outdoor fixed type (IP-54), triple pole, single break three positions as out going (ON, OFF and Earth) having (IDMTL + INST.) protection, earth fault protection and able to measure the three phase HT 11 KV Voltages and currents with prewired CT of ratio 50/5 A, 50 VA - 3 Nos and three phase PT of ratio 11 KV/ 110 V, 200 VA burden - 01 No with remote and manual operation of HT VCB with copper bus bar and copper earth bar fitted with fixed type voltage indicator device as per IS 61958-1, compactable with front end bottom entry cables and 03 nos terminal protectors for cable side, fully rated with earth switch, Red/Green push button for ON/OFF operation, air insulated cable boxes and 3 sets of right angle boots suitable for bottom entry front termination of PVC unsheathed armoured aluminium cable of size 3 core 185 sqmm, including extension kit,adpater box etc.. required for satisfactory completion of job complete all as specified by the Engineer - in - charge. Note : Cost of PCC for base as recommended by OEM and other misc items required for satisfactory completion of job is deemed to be included in the rate quoted by the contractor.
Supply ,install testing and commissioning of cubical Metering Panel , Outdoor Type made out of 3mm thick mild steel, double door, powder coated with locking arrangement & consisting of: (a) 11kV Indoor Single-Phase Resin Cast Current Transformer, Ratio 50/5, Accuracy Class 0.2S, 50VA Burden – 3 Nos (b) 11kV Indoor Three Phase Potential Transformer, Ration 11kV /110V, Accuracy Class 0.2, Burden 100VA – 1Nos (c) TOD Meter - Trivector Energy meter 3 Phase 4 Wire HT CT/PT Operated, Unidirectional, Accuracy Class 0.2S for both Active and Reactive Energy, Current Rating 5A Secondary, Static with TOD Register having ISI Mark, suitable for measurement of active energy kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz - 1 Nos With necessary connections as per SEB TMR Division including Test Terminal Block, Control Fuse etc. complete all as specified Note : Contractor is responsible for calibration of CT/PT and trivector meter at TMR division of Kerala State Electricity Board, Angamaly, Kochi and submit the same to GE (Navy) Lakshadweep for obtaining the approval from Lakshadweep Electricity Department
Supply, install, testing and commissioning of 11 KV 630A, 21 KA, SF6 gas insulated motorized extensible 1 way VCB, type MCRV Fully weather proof with IP54 degree of protection for outdoor type application having thickness of minimum 3mm , all switching functions are enclosed in SF6 gas insulated robotically welded and sealed stainless steel tank with leakage rate of less than 0.1% per year, internal arc classified and type tested as per IEC 62271 standards, fully interlocked operation with padlocking facility for maximum operator protection and safety.Provision of cable termination suitable for cable of size up to 3 core x 185 Sqmm at front bottom side of the VCB should comply the following technical specifications:- (i) Rated voltage 12/15.5 KV. (ii) Rated current 630 A. (iii) Power frequency with stand voltage 28 KV. (iv) Short circuit breaking current 21KA/3Sec. (iv) Impulse with stand voltage 75 KV. (v) Making current 52.5 KAp. (vi) Ingress protection for enclosure IP 54. (vii) Ingress protection for tank IP 67. (viii) Internal arc rating 21.20 KA /1 Sec
Supply, Install, Testing and commissioning of automatic power factor controller (APFC) panel indoor type made of CRCA sheet enclosure of thickness not less than 2mm thick powder coated of approved color of capacity 240 KVAR, 07 stages (50 KVAR x 3 No, 25 KVAR x 3 Nos & 15 KVAR x 1 No) 3 pole, 440 V, 50 Hz with APP type capacitors with 7 % detuned harmonics filters, consisting of the following:- (i) MCCB, 400 A, 50 KA, 4 pole, 415 V with microprocessor based release as incomer (ii) Microprocessor controller for auto power factor correction having auto/manual modes (iii) Copper bus bar of current rating 400 a for R,Y,B & N (iv) R,Y,B indicating lamps digital multi function meter for indicating power factor, active power, reactive power, apparent power, voltage & current (v) MCB,3 pole power contactor, auxiliary contactors of desired rating for switching ON/OFF of capacitor banks of desired rating for switching on/off of capacitor banks. (vi) In connecting PVC insulated FRLS cables of size single core 25 sqmm with copper lugs and all other misc works required for satisfactory completion of job included in the rate quoted by the contractor.
Cutting the existing road to a size of 25 cm x 25 cm , 3 metre long for laying the GI pipe, light grade of 80mm bore as mechanical protection for HT UG Cable complete including making good the cut portion by filling hardcore 10cm thick and finishing with PCC 1:2:4, 15 Cm thick complete and removing the excavated materials complete all as specified
XLPE insulated PVC round, unarmoured, electric power cables (heavy duty) with multi stranded copper conductor, 1100 Volts grade, of size single core 95Sqmm complete all as specified
Cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 Core 185 Sqmm complete all as specified
Chemical earthing with copper earth plate 90x60cmx5mm and copper earth strip 50x6mm complete all as specified
SEWAGE DISPOSAL : Provision of 10 users capacity hume pipe septic tank designed to carry sewage and sullage water including excavation in any type of soil, returning/filling and removal of soil , PCC 14:8 below in ffoundation , vent shaft connection pipe etc complete all as specified and as shown on drawings (TD/A/157, Sheet No 1/1)
Construction of soakage well of size 1.8 m dia x1.5 m depth with excavation in any type of soil, foundation in PCC 1:3:6, wall of honey combed masonry with top ring M25 concrete including intercepting chamber and screen chamber made of PCC block masonry with cement mortar , RCC cover slab in M25 interconnecting pipes complete filled with bricks bats complete all as specified and as shown on drawings (TD/A/162, Sheet No 1/1)
Linsta Services
Classic Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .