Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L1 | Accepted-AOC First lowest bidder | |
| 2 | L2₹1.4 L+₹399 (0.28%)Rejected-AOC | L2 | Rejected-AOC second lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Documents not submitted as per tender condition |
| Sl No | Description | Qty | Unit | Mahalaxmi Enterprises L1 | J S Electronics L2 |
|---|---|---|---|---|---|
| 1.00Repairing, servicing and replacement of different parts of medical equipment in various department of Dr. R. N. Cooper Hospital. | |||||
| 1.01 | Repairing and replacement of 3CX2.5Sqmm heater wiring (4 Mtr) and cyramic connector of autoclave machine in Ortho OT | 1 | Nos. | 2,470 ₹2,470 Lowest | 2,475 ₹2,475 |
| 1.02 | Replacement of Laryngoscope handle in ANC/ PNC department | 1 | Nos. | 453 ₹453 Lowest | 455 ₹455 |
| 1.03 | Repairing and replacement of parts of BP apparatus in ENT/ opthal/ skin ward (Cuff, Balloon, valve) | 2 | Nos. | 680 ₹1,360 Lowest | 695 ₹1,390 |
| 1.04 | Replacement of 12V DC SMPS with 2 Mtr power cord (3CX2.5Sqmm) of phototherapy machine in ANC/ PNC ward | 1 | Nos. | 1,815 ₹1,815 Lowest | 1,820 ₹1,820 |
| 1.05 | Replacement of 230V/12V DC, 2 Amp L.V. transformer of phototherapy machine in ANC/ PNC ward | 1 | Nos. | 2,430 ₹2,430 Lowest | 2,433 ₹2,433 |
| 1.06 | Replacement of 6V DC, 5W LED bulb of phototherapy machine in ANC/ PNC ward | 6 | Nos. | 85 ₹510 Lowest | 87 ₹522 |
| 1.07 | Repairing and replacement of parts of BP apparatus in ANC/ PNC ward (Cuff, Balloon, valve) | 2 | Nos. | 680 ₹1,360 Lowest | 695 ₹1,390 |
| 1.08 | Replacement of Air pump bearing (No.- 371, ceramic) and 20mm pressure valve of portable suction machine in NICU ward | 1 | Nos. | 2,470 ₹2,470 Lowest | 2,472 ₹2,472 |
| 1.09 | Replacement of belt (Nilon 703 no.) of portable suction machine in NICU ward | 1 | Nos. | 1,608 ₹1,608 Lowest | 1,610 ₹1,610 |
Tender Value
Refer Docs
EMD Value
₹1,700
Closing Date
13 Oct 2025, 1:00 pmClosed
Dean Dr. R. N. Cooper Mun. Gen. Hospital
Dr. R. N. Cooper Mun. Gen. Hospital
Repairing, servicing and replacement of different parts of medical equipment in various department of Dr. R. N. Cooper Hospital.
2025_MCGM_1224320_1
HO/1194/RNCH/DTD. 05.09.2025
Open Tender
Electrical Works
Item Rate
30 days
Dr. R. N. Cooper Mun. Gen. Hospital. Vile Parle W
Please refer Tender documents.
3 documents required · 3 mandatory
₹429
₹1,700
30 Apr 2026
1 Oct 2025
13 Oct 2025
1 Oct 2025
13 Oct 2025
1 Oct 2025
Amount
Repairing, servicing and replacement of different parts of medical equipment in various department of Dr. R. N. Cooper Hospital.
Repairing and replacement of 3CX2.5Sqmm heater wiring (4 Mtr) and cyramic connector of autoclave machine in Ortho OT
Replacement of Laryngoscope handle in ANC/ PNC department
Repairing and replacement of parts of BP apparatus in ENT/ opthal/ skin ward (Cuff, Balloon, valve)
Replacement of 12V DC SMPS with 2 Mtr power cord (3CX2.5Sqmm) of phototherapy machine in ANC/ PNC ward
Replacement of 230V/12V DC, 2 Amp L.V. transformer of phototherapy machine in ANC/ PNC ward
Replacement of 6V DC, 5W LED bulb of phototherapy machine in ANC/ PNC ward
Repairing and replacement of parts of BP apparatus in ANC/ PNC ward (Cuff, Balloon, valve)
Replacement of Air pump bearing (No.- 371, ceramic) and 20mm pressure valve of portable suction machine in NICU ward
Replacement of belt (Nilon 703 no.) of portable suction machine in NICU ward
Replacement of pressure valve bolt (5/8) of autoclave machine in CSS department Sr. no. 205
Replacement of power card (230V AC supply, 12V DC) of X-ray view box in X-ray department
Replacement of toggle (230V, 5Amp) switch of X-ray view box in X-ray department
Replacement of 0.5HP motor, bearing & carbon brush of suction machine in Male Medical Ward (Bearing- 371 No. ceramic body, motor belt- Nilon, 703 no. ID- 20200500375 ID- 20200400632
Replacement of 12V DC, 12W LED bulb of Hot air oven in OPD-12
Replacement of 3KW Heater coil of Hot air oven in OPD-12. (230V AC)
Replacement of 230V AC, 24V DC, 10Amp relay of fridge in Psy ward
Replacement of fan of 273Ltr fridge in Psy ward
Repairing and replacement of parts of BP apparatus in All OPD (Cuff, Balloon, valve)
Replacement of 0.5HP motor of suction machine in OPD no. 22. (Bearing no. 371, carbon brush & toggle switch)
Replacement of 12V DC, 12W LED light of Hot Air oven in OPD-12
Replacement of Sensor of Hot Air oven in OPD-12
Repairing and rewinding of 0.5HP motor suction machine in Gynec OT, B wing (Bearing no. 371, carbon brush & toggle switch)
Replacement of (230V AC to 24V DC) Control box of X-ray view box in ENT OT
Replacement of power 3CX2.5Sqmm cord of X-ray view box in USG department
Replacement of (230V, 3Amp) ON/OFF switch of X-ray view box in USG department
Replacement of 8mm Door gasket of autoclave machine in CSS department
Replacement of (230V AC to 24V DC) Control box of Triple Dome lights in Major OT
Replacement of PCB card of Triple Dome lights in Major OT
Replacement of 12V, 1600mAh Battery of Syringe pump in casualty department
Replacement of Ambubug in Male Surgical ward
Repairs of side guard and replacement of wheels of fowler beds in Male Surgical ward
Replacement of 12V DC SMPS Box of X-ray view box in Male Surgical ward
Replacement of 230V, 3 Amp ON-OFF switch of X-ray view box in Male Surgical ward
Rewinding of 05HP suction motor in CSS department
Replacement of 2" PVC pipe in CSS department
Replacement of sensor in CSS department
Replacement of 230V AC, 24V DC, 10Amp relay in CSS department
Replacement of (230V AC to 24V DC) control box of shadow lamp in Labor ward/ C-OT
Replacement of 24V DC, 100W LED bulb of shadow lamp in Labor ward/ C-OT
Replacement of holder of shadow lamp in Labor ward/C-OT
Replacement of 3KW coil of sterilizer in Gynec OT
Replacement of 12V DC SMPS board of mobile light in Labor ward/ C-OT
Replacement of 3KW sterilizer coil in Male Medical ward
Replacement of washing machine regulator control box in male medical ward
Replacement of 230V AC, 24V DC, 10Amp relay in male medical ward
Replacement of 3KW sterilizer coil in Female Ortho ward
Replacement of 3KW sterilizer socket with wire in Female ortho ward
Replacement of 3KW sterilizer coil in OPD-7
Replacement of 8mm door gasket of Fridge in OPD-11
Replacement of 230V AC, 24V DC, 10Amp relay of fridge in OPD-11
Replacement of 230V, 9W UV tube lights of X-ray view box in ortho OT
Replacement of speed regulator SMPS of washing machine in Male Medical ward
Replacement of 230V AC, 24V DC, 10Amp relay of washing machine in Male Medical ward
Replacement of 6W LED bulb of Non Contact of Tonography machine in 22 no. OPD.
Replacement of 12V DC SMPS of LED bulb of Non Contact of Tonography machine in 22 no. OPD.
Replacement of 0.5HP motor, bearing & carbon brush of suction machine in MICU
Replacement of 12V DC SMPS Box of X-ray view box in Peadiatric ward
Replacement of 230V, 6Amp ON-OFF switch of X-ray view box in Peadiatric ward
Replacement of (230V AC to 24V DC) Control box of X-ray view box in Peadiatric ward
Replacement of 3CX2.5Sqmm power cord of X-ray view box in Peadiatric ward
Replacement of 3KW heater coil of Autoclave machine in CSS department
Servicing of filter of patient warmer in AICU department
Replacement of 0.5HP motor, bearing and belt of suction machine in Labor ward
Replacement of (230V AC to 24V DC) Control box of X-ray view box in Male Surgical ward
Replacement of 230V, 6Amp power cord of X-ray view box in Male Surgical ward
Repairs and welding of fowler beds in PICU
J S Electronics (BID ID -6908789)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
SBD.pdf
Tender Documents • 0.81 MB
BOQ_2113229.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .