Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Due to lowest bid | |
| 2 | L2₹20.1 L+₹1.5 L (8.12%)Rejected-Finance | L2 | Rejected-Finance Due to higher bid | |
| 3 | L3₹20.8 L+₹2.2 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Due to higher bid | |
| 4 | L4₹21.6 L+₹3.0 L (16.2%)Rejected-Finance | L4 | Rejected-Finance Due to higher bid | |
| 5 | L5₹24.5 L+₹5.9 L (31.9%)Rejected-Finance | L5 | Rejected-Finance Due to higher bid |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 Mar 2024, 6:00 pmClosed
GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
REPAIR REWIRING OF FAN EXHAUST FAN UNDER AREA OF AGE EM OF GE (WEST) FEROZEPUR CANTT
2024_MES_644039_1
802024/GE-01/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹60,000
Yes
24 Apr 2024
28 Feb 2024
2 Apr 2024
28 Feb 2024
26 Mar 2024
13 Mar 2024
Amount
Taking down defective ceiling fan from existing location of Md Accomodation and OTM Accomodation area and dismantling of ceiling fan sweep 1200/1400 mm including fan blade, down rod, coupling, decorative caps, condenser housing, stator and rotar and replacement of defective parts complete all as specified including complete overhauling as per manufacturers instructions, reassembling and testing of 24 hours complete and after repair refix at existing location of MD Accomodation and OTM complete all as specified and directed. Notes : 1. Repair/maintenance work will be carried out at site OTM and Md Accomodation. 2. Emergency/genuine complaint should be done by contractor within 24 hours if not done a recovery of amounting to ₹ 350 will be charged.
All as per srl item No 01 here in before but Wall mounted fan of 450 mm.
All as per srl item No 01 here in before but Exhaust fan of 230 mm (9'') and 300mm (12").
All as per srl item No 01 here in before but Exhaust fan of 380 mm (15") and 450 mm (18'').
Taking out the old burnt out winding from the fan, rewinding with super enameled superior quality copper conductor winding with similar gauge & size as per original including sleeves, varnishing etc of ceiling fan 1200/1400 mm complete and repaired fan should be refixed at existing location of MD/OTM accommodation after testing of 24 hours complete all as specified and directed.
All as per item No 5 here in before but wall mounted fan 450mm.
All as per item No 5 here in before but Exhaust fan of 230 mm (9'').
All as per item No 5 here in before but Exhaust fan of 300 mm (12'') and 380mm (15").
All as per item No 5 here in before but exhaust fan of 450 mm (18'').
S&F in repair/replacement of motor with copper winding suitable for 200/250/300 mm plastic exhaust fan/ventilating fan/Air circulating fan/Fresh Air fan including disamantiling and refitting and connection of exhaust fan complete and repaired fan should be refixed at existing location of MD/OTM accommodation after testing of 24 hours complete all as specified & directed.
M&L for two coat of painting for ceiling fans/wall mounted fan/exhaust fan complete with synthetic enamel paint by spraying including writing CA No and MES No in black paint filling cavities with filler after cleaning all dust etc complete all as specified and directed.
S&F in repalcement flexible 2 core copper conductor cable of size 0.75 sqmm wire PVC insulated super conductor twin core for replacement from ceiling rose to ceiling/exhaust fan complete all as specified and directed. Make : Havells/Anchor/Polycab/Finolex
S&F in repalcement capacitor of 2.5 MFD and after repair refix at existing location of MD/OTM accommodation all as specified & directed. Make : EFCOS/ASIAN/Bajaj/Havells
S&F in repalcement capacitor of 4 MFD and after repair refix at existing location of MD/OTM accommodation all as specified & directed. Make : EFCOS/ASIAN/Bajaj/Havells
S&F in repalcement Ball bearing Suitable for ceiling fan of sweep (200/1400mm) 48" duly greased packed in suitable size (6201/6202) packing and after repair refix at existing location of MD/OTM accommodation all as specified & directed. Make : NBC/SKF/TATA
S&F in repalcement of complete hanging clamps upper and lower bolt, nut, washer, split pin, rubber reel of requred size complete all as per specified and directed. Note : Repair/maintence work will be carry out at site OTM and Md Accomodation.
S&F in repalcement of fixing screw of fan blade any size and after repair refix at existing location of MD/OTM accommodation all as specified & directed.
S&F in repalcement Bush suitable for any type of ceiling fans/ wall mounted fan/ exhaust fan, incl mechanical laithe work all as specified and directed.
S&F in repalcement shaft suitable for any type of ceiling fan including mechanical laith work etc and after repair refix at existing location of MD/OTM accommodation all as specified & directed
S&F in repalcement plastic canopy (set of 02) with screw suitable for 1200/1400mm sweep and after replace, refix at existing location of MD/OTM accommodation all as specified & directed
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 Volts, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 with brushless direct current motor (BLDC) complete all as specified and directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 Volts, 50 Hz, RPM 1200, Copper winding of sweep 200/250mm complete all as specified
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 Volts, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified
S&F exhaust fan, steel body AC single Phase 230 Volts of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
S&F exhaust fan, steel body AC single Phase 230 Volts of size 380mm sweep with, blades, and frame and louvers complete all as specified and directed.
S&F exhaust fan, steel body AC single Phase 230 Volts of size 450mm sweep, heavy duty with, blades, and frame and louvers complete all as specified and directed.
S&F ceiling fan blade 1400 mm of Make Crompton made out of aluminium sheet 14 guage duly painted each (set of Three) and after replace refix at existing location of MD/OTM accommodation complete all as specified & directed.
S&F ceiling fan blade 1200 mm of Make Crompton made out of aluminium sheet 14 guage duly painted each (set of Three) and after replace, refix at existing location of MD/OTM accommodation complete all as specified & directed.
S&F of Exhaust fans M S frame complete with legs (set of four) including rubber as per sample for 380 mm (15") and 450 mm (18") sweep complete including removal of old unserviceable frame and after replace, refix at existing location of MD/OTM accommodation complete all as specified & directed.
S&F wall mounted fan of size 450 mm sweep AC single phase 230 Volts complete all as specified & directed.
S&F wall mounted fan sweep of size 450mm complete all as specified and directed.
S&F in replacement of fan blade for Exhaust fan 9" & 12" and after repair refix at existing location of MD/OTM accommodation complete all as specified & directed.
S&F in replacement of fan blade for Exhaust fan 15" & 18" and after repair refix at existing location of MD/OTM accommodation complete all as specified & directed.
S&F down rod 15mm dia of 18"/24" in length alongwith hole at one end and cut for hanging of fan and after replace, refix at existing location of MD/OTM accommodation complete all as specified & directed
Guru Kirpa Trading Company
M/s Manoj Construction Co.
M/s Shri Krishna Enterprises
manoj and company
GS and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .