Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC GUDUPAHI CHANDIPUR BALASORE ODISHA 756025 | CHANDIPUR | BALASORE | ODISHA | 756025 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.9 L+₹7.1 L (20.3%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹42.6 L+₹7.8 L (22.3%)Rejected-Finance SRIKONA CHANDIPUR BALASORE 756 025 | BALASORE | BALASORE | ORISSA | 756025 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹45.6 L+₹10.7 L (30.7%)Rejected-Finance AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹46.1 L+₹11.3 L (32.4%)Rejected-Finance SHOPING COMPLEX CHANDIPUR BALASORE 756025 | BALESHWAR | ODISHA | 756025 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
14 Mar 2023, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
PROVN OF ENVIRONMENTAL CHAMBER OPERATION ROOM AND OPEN SHED AT PXE CHANDIPUR
2023_MES_582508_1
8806/CDP
Open Tender
Civil Works
Item Rate
180 days
Chandipur
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹69,000
Yes
28 Mar 2023
23 Feb 2023
16 Mar 2023
23 Feb 2023
14 Mar 2023
9 Mar 2023
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I {BUILDING WORK (B/R PORTION)}
Surface dressing n exc. 15 cm deep. In soft/loose soil complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil complete all as specified and directed.
Excavating over areas, exc 1.5 m deep n exec 3.0 m deep and getting out - Soft/loose soil complete all as specified and directed.
Boring for Bored cast in situ piles 9 metres in soil and getting out and disposal of spoil to a distance 50 metres using DMC method (Direct mud circulation) (450 mm) complete all as specified and directed.
M&L for treating the bottom and sides of excavation with ATT at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L treating the backfill in contact with foundation with ATT at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L treating the top surface of filled earth with ATT at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L treating the soil under plinth protection with ATT at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L Cement Concrete in foundation, filling and mass concrete Type D2, 1:4:8 ( 40 mm graded aggregate ) complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions. quare,Rectangle or Polygon (Substructure/Superstructure) complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed.
M&L for RCC, M-30 (design mix) using 20mm graded Aggregates in foundation, including rafts, footings, foundation beams, plinthbeams, bases for columns, etc, basement slab, under rimmed piles and mass concrete complete all as specified and directed.
M&L RCC, M-30 (design mix) using 20mm graded Aggregates in column, pillars, piers, posts and struts. (Substructure/Superstructure)complete all as specified and directed.
M&L RCC, M-30 (design mix) using 20mm graded Aggregates in slabs supported on walls, beams and column in floors, roof, landings, balconies, canopies, deck slabs and in shelves and the like.complete all as specified and directed.
M&L RCC, M-30 (design mix) using 20mm graded Aggregates in chajjas complete all as specified and directed.
M&L RCC, M-30 (design mix) using 20mm graded Aggregates in beams, cantilevers, bressumers, lintel over 1.5 mt span complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm Soft soil/loose soil complete all as specified and directed.
M&L for sand filling under floors or in foundation including watering and consolidation as in Plinth Filling complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
S&F Steel/Reinforcement Bars Mild steel bars (Fe 500D) (CRS) 10 mm dia and over, cut to length, bent to shape requied, including cracking, bending soirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clips quality conforming to TMT bars complete all as specified and directed.
S&F for Steel/Reinforcement Bars Mild steel bars (Fe 500D) (CRS) 6 to 8 mm dia, cut to length, bent to shape requied, including cracking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clips quality conforming to TMT bars complete all as specified and directed.
S&F for Steel/Reinforcement Bars (Fe 500D) (CRS) 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls,built in cement mortar 1:6 complete all as specified and directed
M&L for 10 mm thick cement plaster in C:M 1:6 finished above dado/ skirting including 1.5 mm thick wall care putty on internal wall surfaces complete all as specified and directed
M&L for 15 mm thk cement plaster intwo layers of 15 mm and 5 mm C:M 1:4 and outer laye of 5 mm thick with liquid water proofing compound. External plaster complete all as specified and directed. Note : Liquid WPC shall be measured and paid separately.
Supply only liquid Water Proofing compound.
M&L 5 mm thick cement plaster in CM 1:3 on soffit of RCC slab, beams , lintel and projection Ceiling Plaster complete all as specified and directed
M&L for double charged Vitrified ceramic tiles 7-8 mm thick area of each tile exc 0.11 but n exc 0.18 over 20 mm bedding layer in CM 1:6 over 75 mm thick PCC 1:3:6 type C2 over 75 mm thick sand coushing over 150 micron polythene film over rammed earth complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick of size 400x400 mm over 20 mm bedding layer in CM 1:4 over 75 mm thick PCC 1:3:6 type C2 over over 75 mm thick sand coushiing over 150 micron polythene film over rammed earth complete all as specified and directed.
M&L double charged Vitrified ceramic tiles 7-8 mm thick high as in skirting over 10 mm thick screed 1:4 to match the floor finish/border as specified.
M&L for Glazed ceramic tiles (glossy finished) 7-8 mm thick of size 400 x 300 as in skirting/dado set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed in CM 1:4 as specified.
M&L for preparing surfaces plastered or unplastered on wall applying two coats of oil bound distemper over a coat alkali resistant primer complete all as specified and as directed.
M&L for preparing surfaces plastered or unplastered on wall two apply coats of exterior emulsion weather paint over a coat of exterior wall primer complete all as specified.
M&L for preparing surfaces plastered or unplastered on ceiling apply two coats of oil bound distemper over a coat of interior primer complete all as specified.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces except aluminium portion not otherwise described, over 10cm width or grith complete all as specified.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces except aluminium portion not otherwise described, over 10cm width or grith complete all as specified.
S&F 2nd class hard wood plain , solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints.
S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing complete all as specified and as directed.
S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame complete all as specified and as directed.
S&F 35mm thick factory made 2nd class hardwood shutters plain framed, panelled shutter ( two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part 1) kiln seasoned and chemically pressure treated.
S & F powder coated (Thickness or powder coating not less than 50 micron) aluminium window and ventilator shutters, fixed type (three tire, two Nos glass and one No wire mesh window shutter) without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. (Note : S&F rates, include for handles, hinges, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames as required.
S&F Aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (Note : Min thickness of power coating should not be less than 50 micorn)
S&F Aluminium handles, cast type,anodised-100 mm complete all as specified
S&F 150mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified
S&F Butt hinges, heavy weight, cold rolled mild steel, and fixed- 75 mm complete all as specified
S&F Aluminium anodised, barrel tower bolts of extruded section and fixed - 150 mm complete all as specified
Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane 5 mm thick.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application including applying of one coat of cold bituminous primer @ 0.40 Liters/Sqm over a coat of 10 mm thick cement plaster in CM 1:4 mixed with liquid WPC as per manufacturer's instruction complete all as specified.
S&F Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I - 500 Litres complete all as specified.
S&F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed- 25 mm complete all as specified
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement of outer dia 75 mm complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified
S&F Vitreous China wash basin, white, flat back, size 630x450mm excluding excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 25 mm dia complete all as specified.
S&F Bib taps, brass chromium plated with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed to 15 mm bore pipe complete.
S&F Stop cock / angular stop cock, brass chromium plated with crutch or butterfly handle, screwed for iron pipe or for unions fixed to 15 mm bore pipe complete.
S & F in viterous china wash down water closet pan (Pedestal pattern) white incl 'P' or 'S' trap and making good the disturbed surface to match with the existing complete all as specified and as directed.
Supply and fixing 10 litre capacity PVC low level valve less syphonic action type flushing cistern (dual flush) white, with inlet, ball valve, float and handle including brackets, flush pipe and bends complete all as specified and as directed.
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including spreader complete all as specified.
S&F PVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as specified.
Supplying and Laying CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with outer dia 16 mm including taking down complete all as specified.
Supplying and Laying CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with outer dia 20 mm including taking down complete all as specified.
Supplying and fixing of 20 mm dia brass CPVC gate valve complete all as specified.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors - 110 mm complete all as specified
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors - 75 mm complete all as specified
S&F PVC waste pipe 32 mm bore complete all as specified
S&F 110 mm dia PVC vent cowl complete all as specified
S & F brass CP Health faucet with 8mm dia, 1.2 Meter long flexible tube & wall hook all as specified & directed by Engineer-In-Charge.
SCHEDULE 'A' PART-II {BUILDING WORK (E/M PORTION)}
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 4 Sqmm (phase & neutral) and one run of 4 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
S&F Switch piano flush type, single pole one way 5 Amps 230 Volts all as specified.
S&F Switch piano flush type, single pole one way 16 Amps 230 Volts all as specified.
S&F socket 6 A, 3pin, 230 Volts flush type all as specified directed.
S&F socket outlet 2 in 1, 16 A, 3pin, 230 Volts flush type all as specified directed.
S&F ceiling rose surface bakelite 65 x 50mm with three terminals with ISI mark all as specified and directed.
S&F ceiling fan complete with blades, down rod, electronic regulator and accessories, 230V, 1400mm sweep, min air delivery 245 m3/min with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete including necessary pvc insulated flexible wire 3 core of suitable size for connecting from ceiling rose to connector etc ,all as specified and as directed
Supply, install & testing exhaust fan Metal Body 300 mm sweep heavy duty 1400 RPM complete fixed to wall with suitable size bolts, grouted to wall and connecting up including provision of cable from connector to fan with three core flexible cable of suitable size with copper conductor from ceiling rose to exhaust fan.
S&F 20W (1'x4') wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation, with necessary wiring, including all required accessories for light fitting with fixing arrangement.
S&F 10W (1'x2') wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation, with necessary wiring, including all required accessories for light fitting with fixing arrangement.
S&F in repair LED Bldg security light fitting 35 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories complete all as specified and as directed.
Supply and fix on wall with bracket arm made out of GI medium grade tube of 40mm dia,1.5 meter long bend to shape 120 degree and 2 Nos of MS Clamp 25x4mm of required lengh/size with one coat of red oxide & two coat of silver metallic paint complete.
Supply and fix circuit/sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through in pvc concealed conduit 20 mm bore medium grade complete all as specified and as directed by the Engr-in-Charge.. Note : (i) Two runs of 4 Sqmm and one run of 4 Sqmm cable shall measured as one length.
Supply and fixing of MCB DB double door made of sheet steel phosphates powder painted with bus bar, neutral link,earth bar and din rail double door type SPN 8 way 240 V (Blank slots covered by Blanking plate)
S & F MCB SP 06 to 32 Amps `C` series, breaking capacity 10 kA complete all as specified and as directed.
S & F MCB SPN 32 Amps `C` series, breaking capacity 10 kA complete all as specified and as directed.
Supply and laying GI pipe light grade (ISI Marked) of size 40 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as directed and specified by Engr-in-Charge.Make: TATA/Jindal/Prakash Note :- Unit rate quoted is deemed to be inclusive of MS clamps along with nuts/bolts/washers etc. if required to be fixed on pole /wall.
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 25 mm x 4 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a disance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I complete all as directed and specified.
SCHEDULE 'A' PART-III (AIR CONDITIONING)
Supply and instalation air cooled split unit air conditioner,electric driven,single phase of capacity of 2 TR,BEE 5 star rated. Note : Quoted rate shall deemed to be included for additional items required for instration of AC. For this account nothing extra shall be admissible by Deptt.
Supply and fix automatic voltage stablizer for automatic operation single phase naturally air coled indoor tyhpe & designed for input varriation between 170 volts to 250 volts with output voltage stablizer at 230 volts with accuracy of + 2.5% and capacity 5 KVA complete all as spd and directed.
SCHEDULE 'A' PART-IV (COVER SHED)
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
M & L for PCC (1 : 2 : 4) type B1 using 20 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
S & F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161 - 1979 grade St.-240 completed all as specified and directed.
S & F for Bands, straps, plates, angle cleats for securing purlins to tubular trusses or rafters, wind ties etc conforming to Fe-410 or Fe 310-0 completed all as specified and directed.
S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as completed all as specified and directed.
Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.
SCHEDULE 'A' PART-V (HARDSTANDING)
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75 mm thick PCC (1 : 4 : 8) type D2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed.
M & L for 25 mm thick Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Removing excavated materials (soil) n. exc 50 m and depositing where directed at a level n.exc 1.50 m above from the starting poing complete all as specified and directed.
SCHEDULE 'A' PART-VI (WATER SUPPLY)
Excavating in trenches n.exc. 1.5 M wide and n.exc. 1.5 m in depth for foundation etc in soft/loose soil.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc. 25 cm all types of soil etc complete all as specified and directed.
Removal excavated material not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc. complete all as specified and directed.
S&F steel water tubing galvanised medium grade 40 mm bore with all fitting fixed to walls or laid in floor complete.
S&F steel water tubing galvanised medium grade 25 mm bore with all fitting fixed to walls or laid in floor complete.
Supply and fix Gun metal globe or gate valve ISI marked high pressure with iron wheel head screwed both ends for 25 mm dia iron pipe line complete all as specified and as directed. Make - Zoloto/Kartar/Lakshmi/Venus or equivalent model of make as per Appendix -A.
Supply and fix Gun metal globe or gate valve ISI marked high pressure with iron wheel head screwed both ends for 40 mm dia iron pipe line complete all as specified and as directed. Make - Zoloto/Kartar/Lakshmi/Venus or equivalent model of make as per Appendix -A.
Material and labour for cutting of the existing GI pipe of existing dia for inserting branch connection complete all as specified and as directed.
SCHEDULE 'A' PART-VII (EXTERNAL ELECTRIFICATION)
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 70 Sqmm 3.5 Core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and as directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removal of excavated soil to a distance n. exc 50 m above the starting point complete all as specified and directed
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 25 mm x 4 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a disance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I complete all as directed and specified.
Taking down serviceable PCC electric pole 9 meters long from its own position and re-install on new place within 10 meter with necessary earth work, PCC foundation in 1:3:6, type C-2 and coupling for the same with electric connection complete all as per directed.
S & F MCCB, 4 pole, 63 Amps, 415 Volts , 25 KA adjustable thermal and magnetic setting with enclosure outdoor type complete all as directed.
SCHEDULE 'A' PART-VIII (SEWAGE DISPOSAL)
Excavating in trenches n.exc. 1.5 M wide and n.exc. 1.5 m in depth for foundation etc in soft/loose soil.
M & L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M & L for PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), cast in situ, in benching, coping and the like etc including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed.
M & L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 (Using locally availably best quality brick) complete all as specified and directed.
Extra for forming fair finish to drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped end etc complete all as specified and directed.
Add or deduct from ser item No.5 above for each 25mm girth or part there of over and under 30cm. (Note: this item is only for adjustment of rates).
M & L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces of walls in cement mortar (1:4) mixed with liquid WPC @ 0.40% by the weight of cement or as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and as directed. (internal surfaces) Note: WPC will be measured and paid separately as “Supply” only.
M & L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces of walls in cement mortar (1:4) finished even and fair complete all as specified and as directed. (external surfaces)
Supply only liquid water proofing compound (WPC) of best quality complete all as specified and as directed.
M & L for precast reinforced cement concrete (1:2:4), type B1 (using 20 mm graded stone aggregate) as in cover slab, shelves and similar articles with plain faces including necessary form work and set in cement mortar (1:4) complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately.
S & F for MS TMT bars (Fe 500D) 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
M & L for 150 mm bore reinforced concrete pipes, class NP2, laid and jointed with collars complete all as specified and as directed.
M & L for PCC (1:3:6) type C-2, using 40 mm graded stone aggregate as in concrete bed to drain pipe including packing under and haunching against sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc. 25 cm all types of soil etc complete all as specified and directed.
Removal excavated material not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc. complete all as specified and directed.
M & L for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete for 10 users complete all as per manufacturers's instruction.
M & L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20 M x 3.00 M effective depth complete all as specified and as directed.
RANA ENTERPRISES
vaishnaveedevienterprises
DS ENTERPRISES
MS VIDYANJALI
M/s Manas Ranjan Bera
M/S JANAKI ENTERPRISES
M/S DK MUKHERJEE CO
Bidder Name
RANA ENTERPRISES
DS ENTERPRISES
MS VIDYANJALI
M/S JANAKI ENTERPRISES
vaishnaveedevienterprises
M/S DK MUKHERJEE CO
M/s Manas Ranjan Bera
M/s MANIK SETHI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .