| 1 | L1₹18.5 LAccepted-AOC FUG FARM VIEW APARTMENTS KHASRA NO 40 SATBARI CHATARPUR HAUZ KHAS SOUTH DELHI NEW DELHI 110074 | NEW DELHI | SOUTH DELHI | DELHI | 110074 | ₹18.5 L Quoted ₹20.6 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹25.4 LRejected-Finance GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | ₹25.4 L | L2 | Rejected-Finance Not Found in order |
| 3 | L3₹25.8 LRejected-Finance JYOTI BAKERY 1ST FLOOR A5 HSEDRI G RZA 5 PALAM NEW DELHI SOUTH WEST DELHI DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹25.8 L | L3 | Rejected-Finance Not Found in order |
| 4 | L4₹25.9 LRejected-Finance | ₹25.9 L | L4 | Rejected-Finance Not Found in order |
| 5 | L5₹28.0 LRejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹28.0 L | L5 | Rejected-Finance Not Found in order |
| Sl No | Description | Qty | Unit | Microsys Automation India L9 | B.R. Enterprises L10 | jain associates L4 | RS GREEN INDIA CONSTRUCTION L7 | R S ENGINEERS L1 | MM ENTERPRISES L6 | HSEDRIG ENGINEERS AND CONTRACTORS L3 | M P TYAGI ENGINEERS AND CONTRACTORS L5 | AMIT ENTERPRISES L2 | Sukhram & Sons L11 | Lamba Enterprises L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and grey water supply in various locations & taking out water from trenches during repair including note down the complaints in complaint register complete all as specified and as directed
(Note:- Any material required for attending complaints shall be measured and paid separately under respective item herein after as 'Supply only'). | 2,200 | EACH COMPLAINT | 80 ₹1,76,000 | 90 ₹1,98,000 | 79 ₹1,73,800 | 99 ₹2,17,800 | 39 ₹85,800 Lowest | 100 ₹2,20,000 | 67 ₹1,47,400 | 99 ₹2,17,800 | 80 ₹1,76,000 | 100 ₹2,20,000 | 130 ₹2,86,000 |
| 2.00 | Labour only for attending day to day electric supply complaints of day to day maintenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including Note down the complaints from various locations in complaints register and distribution to the trademen complete all as directed.
(Note:-
(i) Any meterial required for atteding complaints shall be measured & paid seperately under respective item here after as 'supply only')
(ii) The suitable shift duites as deems fit shall be decision of the Engr-in-charge | 200 | EACH COMPLAINT | 70 ₹14,000 | 90 ₹18,000 | 59 ₹11,800 | 95 ₹19,000 | 68 ₹13,600 | 150 ₹30,000 | 57 ₹11,400 Lowest | 99 ₹19,800 | 70 ₹14,000 | 300 ₹60,000 | 95 ₹19,000 |
| 2.01Notes for Item No 1.01 & 1.02 :- (i) Any material required for attending complaints shall be measured & separately under respectvie items here - in- after. (ii) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate number of helpers as directed by Engineer-in-charge. (iii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 200/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. (iv) In case, after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. (v) While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' of BOQ. However, no extra payments shall be made for dewatering. (vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch as 'supply only'). (vii) All T&P required for attending the Complaints shall be provided by the contractor.) | ||||||||||||||
| 2.02(viii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc as required at site. (ix) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter, Crimpling tool, insulation tape, Hand gloves etc required at site. (x) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. All the fitting & fixtures shall be measured and paid supply only in respective items of BOQ i.e. Ser Item No. 3 to 16, 17, 18.01 to 18.05, 24, 44 to 50 and 54 to 60. (xi) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record. | ||||||||||||||
| 3.00Supply only in replacement GI Socket 'medium grade' ISI Marked superior / standard of a make of following sizes :- | ||||||||||||||
| 3.01 | 15 mm bore | 200 | EACH | 10 ₹2,000 Lowest | 18 ₹3,600 | 11 ₹2,200 | 22 ₹4,400 | 13 ₹2,600 | 15 ₹3,000 | 12 ₹2,400 | 99 ₹19,800 | 10 ₹2,000 Lowest | 25 ₹5,000 | 40 ₹8,000 |
| 3.02 | 20mm bore | 250 | EACH | 10 ₹2,500 Lowest | 24 ₹6,000 | 15 ₹3,750 | 25 ₹6,250 | 15 ₹3,750 | 20 ₹5,000 | 15 ₹3,750 | 99 ₹24,750 | 12 ₹3,000 | 30 ₹7,500 | 60 ₹15,000 |
| 3.03 | 25mm bore | 80 | EACH | 10 ₹800 Lowest | 28 ₹2,240 | 19 ₹1,520 | 25 ₹2,000 | 17 ₹1,360 | 30 ₹2,400 | 20 ₹1,600 | 99 ₹7,920 | 15 ₹1,200 | 40 ₹3,200 | 60 ₹4,800 |
| 3.04 | 40mm bore | 5 | EACH | 12 ₹60 Lowest | 75 ₹375 | 27 ₹135 | 25 ₹125 | 28 ₹140 | 50 ₹250 | 22 ₹110 | 199 ₹995 | 18 ₹90 | 55 ₹275 | 100 ₹500 |
| 3.05 | 50mm bore | 4 | EACH | 12 ₹48 Lowest | 99 ₹396 | 40 ₹160 | 45 ₹180 | 37 ₹148 | 80 ₹320 | 25 ₹100 | 199 ₹796 | 20 ₹80 | 70 ₹280 | 100 ₹400 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Jan 2026, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIR FOR ATTENDING DAY TO DAY EM EXTERNAL WATER SUPPLY COMPLAINTS AT RRRC AREA LORRY ROAD ARMY TRAINING AREA DK PART I IN THE AREA OF AGE U WS No II UNDER GE U WATER SUPPLY DELHI CANTT 10
2025_MES_746317_1
GE/WS/Token No-60 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹90,000
Yes
14 Mar 2026
27 Dec 2025
26 Jan 2026
27 Dec 2025
24 Jan 2026
10 Jan 2026
Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and grey water supply in various locations & taking out water from trenches during repair including note down the complaints in complaint register complete all as specified and as directed (Note:- Any material required for attending complaints shall be measured and paid separately under respective item herein after as 'Supply only').
Labour only for attending day to day electric supply complaints of day to day maintenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including Note down the complaints from various locations in complaints register and distribution to the trademen complete all as directed. (Note:- (i) Any meterial required for atteding complaints shall be measured & paid seperately under respective item here after as 'supply only') (ii) The suitable shift duites as deems fit shall be decision of the Engr-in-charge
Notes for Item No 1.01 & 1.02 :- (i) Any material required for attending complaints shall be measured & separately under respectvie items here - in- after. (ii) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate number of helpers as directed by Engineer-in-charge. (iii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 200/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. (iv) In case, after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. (v) While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' of BOQ. However, no extra payments shall be made for dewatering. (vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch as 'supply only'). (vii) All T&P required for attending the Complaints shall be provided by the contractor.)
(viii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc as required at site. (ix) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter, Crimpling tool, insulation tape, Hand gloves etc required at site. (x) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. All the fitting & fixtures shall be measured and paid supply only in respective items of BOQ i.e. Ser Item No. 3 to 16, 17, 18.01 to 18.05, 24, 44 to 50 and 54 to 60. (xi) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record.
Supply only in replacement GI Socket 'medium grade' ISI Marked superior / standard of a make of following sizes :-
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
Supply only in replacement GI Elbow 'Medium grade', ISI Marked superior / standard of a make of following sizes : -
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
Supply only in replacement GI Union 'Medium grade', ISI Marked superior / standard of a make of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only in replacement 'GI Nipple' of suitable length as required at site & ordered by EIC both end screwed 'Medium Grade', ISI marked superior / standard of a make of following sizes:
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
S & F in replacement PVC 'L' type Holder suitable for Aluminium rod,Float Ball etc all as required at site and complete all as specified and as directed of following Sizes:-
15 mm bore
20 mm bore
Supply only GI Reducing socket 'medium grade' ISI marked superior / standard of a make of the following sizes :-
25 mm x 15 mm bore
20 mm x 15 mm bore
25 mm x 20 mm bore
40 mmx 20mm bore
40 mmx 25mm bore
50 mmx 20mm bore
Supply only in replacement GI Reducing Elbow medium grade ISI marked of the following sizes :-
20mmx15mm bore
25mmx15 mm bore
Supply only in replacement GI Tee 'Medium grade' ISI Marked superior / standard of a make of following sizes : -
15mm x 15mm x 15mm
20 mm x 20 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 25 mm
25 mm x 25 mm x 15 mm
25 mm x 25 mm x 20 mm
40 mm x 40 mm x 20 mm
Supply only in replacement GI Solid plug heavy duty ISI Marked superior / standard of a make of following sizes : -
15 mm bore
20 mm bore
25 mm bore
S & F Lead pig bar
S & F spun yarn
S & F gland packing of any size
S & F 3 mm thick rubber Gaskets suitable for any size of flanges upto 200 mm dia
Supply only in replacement PTMT float valve with epoxy coated aluminium rod and high density plastic ball of following sizes complete all as specified and as directed
15 mm bore
20 mm bore
25 mm bore
S & F in replacement Tank Nipple suitable for HDPE water tank 20 mm dia
S&F in replacement of old gun metal gate valves with iron wheel head screwed both ends for iron pipe, ISI marked as per IS : 778 of following sizes complete all as specified and as directed
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Testing of drinking water collected from local source (bore wells /shallow wells in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, pH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from[ different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification Note 1:- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) Note 2:- Test reports so collected will be submitted to the Engr-in-Charge every month and failing to which will attaract a penaly of ₹5000/- per report and will be recovered from his RARs/Bills
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Surface dressing of uneven surfaces of the natural ground, rough excavated surfaces and filled area where ordered shall be trimed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site. depth of cutting not exceeding 15 cm complete all as specified and as directed.
S & F in replacement 15 mm bore Bib tap in replacement of old standard of PTMT any colour high pressure screwed for male/ female treaded, for UPVC pipe of size 15mm bore complete all as specified and as directed
Labour work required for taking out suction pipe from sump of any capacity 80 mm to 200 mm size screw / flanged type and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket / lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as specified and directed by Engineer - in - charge
Supply and fixing rotational moulded polyethylene water storage tank, cylindrical vertical with closed top, 500 ltrs capacity, tripple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed. Note: (i) For Pump Priming purpose in pump house.
M & L For Manual Boring under Road for insertion of Pipeline upto 200 mm dia complete all as specified and directed
S&F in replacement of GI pipe 'medium grade' ISI mark including all fittings in old/new positions in trenches/wall/floor complete and making good the distributed surfaces as per existing as directed of following sizes. (Note:- Excavation and earth work will be measured and paid separately.)
S & F in replacement of old worn out/broken cast iron/ DI fitting for flanged /spigot and socketed pipes such as bends , reducer, tee pieces , tail pieces , collar, cross , caps & plug upto 150mm bore
80mm bore
100mm bore
150 mm bore
200 mm bore
S & F in replacement PPR Pipe PN-16, SDR 7.4 of following size
20 mm bore
25 mm bore
90 mm bore
110 mm bore
Supply and fixing in replacementy of old for mild steel work for manhole cover, stair case steps made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed.
Supply, fixing, jointing & testing cast Iron Sluice Valve of following size ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm dia
100 mm dia
150 mm dia
Supply, fixing, jointing & testing Cast Iron Non Return Valve without by pass arrangement, swing type confirming to IS 5312, flanged ends pressure reating PN1.0 complete including taking out unsv NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material including replacement of SS Hexagonal nuts, bolts and washers of suitable size including replacement of flange gasket of suitable thickness shall deemed to be included in the units rate of this item
100 mm bore
150 mm bore
Supply, fixing, jointing & testing Cast Iron Foot Valve flanged ends, swing type operation with rubber sheet confirming to IS 4038 complete including taking out unsv Foot Valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material including replacement of SS Hexagonal nuts, bolts and washers of suitable size including replacement of flange gasket of suitable thickness shall deemed to be included in the units rate of this item
100 mm bore
150 mm bore
Supply, installation & testing of flanged ends Water Meter ISI marked woltman type, class 'B' of following sized and making good connection with flanged ends,with rubber sheet gasket and nuts & bolts fixing in horizontal/inclind/verticle position, including taking out UNSV water meter complete all as specified and as directed. type operation with rubber sheet confirming to IS 4038 complete including taking out unsv Foot Valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material including replacement of SS Hexagonal nuts, bolts and washers of suitable size including replacement of flange gasket of suitable thickness shall deemed to be included in the units rate of this item
80 mm bore
100 mm bore
150 mm bore
Material & Labour for painting on steel and iron surfaces with one coat of synthetic enamel paint as per existing colour scheme or pattern complete all as specified and directed
Multipurposes grease lubricant for Motors and Pumps
Supply & Fixing in Replacement of XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade of following sizes complete all as specified and directed Note : Earth work excavation will be measured and paid seperately under relevant items)
Crossectional area 16 Sqmm x 4 core
Crossectional area 25 Sqmm x 3.5 core
Crossectional area 35 Sqmm x 3.5 core
Crossectional area 50 Sqmm x 3.5 core
Crossectional area 120 Sqmm x 3.5 core
Labour only for laying existing burnt bricks sub class 'B' old size laid in trenches with equal to length of bricks across the cable for cable protection complete all as specified and as directed
Supply and spread clean dry river sand to required width at bottom and top for cable cushioning all as specified and as directed
Material and Labour Burnt bricks sub class 'B' old size laid in trenches with equal to length of bricks across the cable for cable protection all as specified and as directed
Repair/maintenance of juction box/pole box as per site including serviceable of bus bar, MCB & changing of cable or make it serviceable condition all as specified and directed.
Supply &Fixing in replacement elecrtonic timer type ST 100 for fixing in panel complete all as specified and as directed
Supply & fixing in replacement of Fully automatic Star-Delta Starter with sheet metal enclosure ML 1.5
Supply only in replacement of 3 pole power contactor Type MNX 25, 110 Amp, 415/220 volts ,50 hz coil voltage 415 volt
Supply only in replacement of 3 pole power contactor Type MNX 32, 110 Amp ,415/220 volts ,50 hz coil voltage 415 volt
Supply only in replacement of thermal over load relay type MN relay range 28-42 Amps
Supply only in replacement of thermal over load relay type MN relay range 20-32 Amps
Supply only in replacement of thermal over load relay type MN relay range 13-21 Amps
Supply and fixing in replacement LED batten arrow for multi application suitable for 18 watts with & including necessary cable connection to make it functional complete all as specified and as directed
Earthing complete with galvanised steel earth plate electrode 600 x 600 6 mm thick burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level connected to the Galvanised iron strip 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanised iron and 32 x 6 mm GI strip procted by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC 1: 2: 4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 kg/sqm and 6 mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashe and medium GI protection pipe 15 mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I complete all as specified and as directed. Note:- 1. Main Earthing strip from earth plate electrode to test point upto length of 7.t meters shall deemed to be included in the unit rate quoted against this items. 2. On testing after completion of the earthing work if the desired resistenance is not obtained, the contractor shall redo the the complete earth work without any extra cost to the department.
Material and labour in replacement for point wiring complete with 1.5 sqmm (nominal crossectional area) FRLS PVC insulated unsheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbows, reducers except conduit junction box (Junction box will be of MS) including FRLS PVC insulated unsheathed 1.5 sqmm copper earth wire, connecting to common earth dolly and including metal flush box of suitable size for fixing switches/sockets/fan regulators etc complete all as directed for the following:-
One light point/fan point/exhaust fan point/circulator fan point/bell/buzzer controlled by one 1 way switch/bell push etc.
One socket outlet point 5 Amps on the same board
One socket outlet point 5 Amps on the independent board
S&F 3 pin socket outlet 15 Amp, independent with 4 sqmm copper FRLS wire.
Supply & fixing in replacement of switch piano, flush type single pole 1 way, 5/6 Apms complete all as specified and directed.
Supply and fixing in replacement of switch Piano flush type single pole 1 way 15 Amps complete all as specified and directed.
Supply and fixing in replacment of socket outlet 6 Amp 2 in 1,3 pin complete all as specified and directed.
Supply and fixing in replacment of socket outlet 16 Amp 2 in 1, complete all as specified and directed.
Supply and fixing in replacement of Fan regulator step type complete all as specified and directed.
Supply and fixing in replacement of Ceiling rose, surface bakelite, 3 terminal, 240 volts, 5 Apms complete all as specified and directed.
S & F in replacement for fixing MCCB's following sizes in existing/new location complete all as completed.
MCCB 63 Amps 3 Pole 16 KA
MCCB 100 Amps 3 Pole 16 KA
MCCB 125 Amps 3 Pole 16 KA
MCCB 160 Amps 4 Pole 36 KA
MCCB 200 Amps 4 Pole 36 KA
MCCB 250 Amps 4 Pole 36 KA
Supply, Laying & fixing in replacement of MS Pipe (Heavy class 'C') followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following sizes including taking out the old unserviceable pipes :- Note:- (i) MS Flanges and joint shall be deemed to be included in unit quoted rate. .
80 mm dia
100 mm dia
150 mm dia
M&L distempering walls with oil bound distemper dry including washing rubbing down, filling of cracks with putty, including necessary scaffolding work etc. complete all as specified and directed
M&L apply two coat of cement base paint after prepation of surface of walls/sump including Writing letter on Wall/Sump and necessary scaffolding work etc. complete all as specified and directed
M & L for preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 6 mtr long and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide ipto 1.5 mtr from ground level including marking of pole No's with paint complete all as specified and as directed.
M&L for re-painting of LT Panels/feeder pillars with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing on feeder pillar in appropriate size of letters as directed.
supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) with top lamp including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
S & F In replacement of LED Street Light 70 Watt, 230 V, IP65/66 Protection complete all as specified and directed
Re-development of existing bore well, if any capacity size, not more than 160mtrs deep, at the pressure not less than 6 Kgs/Sqcm by disel engine driven air compressor of capacity 630 CFM with & including air pipe and connected items to achieve the minimum yield of 3 litres per second of tube well including transport complete all as specified and as directed
An amount of Rs 2,05,547.00 shall be deducted from BOQ on account of schedule of credit
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_835694.xls
BOQ • 0.46 MB
tender.pdf
Tender Documents • 0.78 MB
Download all tender documents and submit your bid