Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAdmitted-Finance | ₹2.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.9 Cr+₹35.7 L (14.1%)Admitted-Finance 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹2.9 Cr+₹35.7 L (14.1%) | L2 | Admitted-Finance |
| 3 | L3₹2.9 Cr+₹40.1 L (15.8%)Admitted-Finance | ₹2.9 Cr+₹40.1 L (15.8%) | L3 | Admitted-Finance |
| 4 | L4₹3.0 Cr+₹45.5 L (18.0%)Admitted-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹3.0 Cr+₹45.5 L (18.0%) | L4 | Admitted-Finance |
| 5 | L5₹3.0 Cr+₹45.6 L (18.0%)Admitted-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹3.0 Cr+₹45.6 L (18.0%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Gulmarg Electrical Service L2 | T.THIYAGARAJAN L1 | Sree Tirumala Enterprises L5 | BHARAT MULTITECH INDUSTRIES PVT LTD L4 | NAWAZ CONSTRUCTIONS L7 | Vandana Enterprises L3 | KAPOOR AUTOMOBILES L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard/dense Soil. | 358 | CUBIC METRE | 250 ₹89,500 | 102 ₹36,516 Lowest | 300 ₹1,07,400 | 207 ₹74,106 | 250 ₹89,500 | 300 ₹1,07,400 | 250 ₹89,500 |
| 2.00 | M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 50 to 100 mm from column/ beams outer surface and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt, other foreign particles and removal of debris to a distance not exceeding 50m including necessary scaffolding etc, complete all as specified and directed. | 703 | SQUARE METRE | 120 ₹84,360 | 45 ₹31,635 | 200 ₹1,40,600 | 153 ₹1,07,559 | 200 ₹1,40,600 | 20 ₹14,060 Lowest | 375 ₹2,63,625 |
| 3.00 | M&L for cleaning of rust/ scales/corrosion from reinforcement bars using rust remover Reebakleens RR of Fosroc or equivalent as approved by GE. The material shall be applied to the rusted metal using brush and make leaving to dry for 30 mins & washing the surface with fresh water as required to exposed reinforcement bars complete all as specified and directed.
Note : The work shall be carried out by the authorised applicator by the company | 150 | SQUARE METRE | 150 ₹22,500 | 25 ₹3,750 Lowest | 55 ₹8,250 | 360 ₹54,000 | 150 ₹22,500 | 200 ₹30,000 | 510 ₹76,500 |
| 4.00 | M&L for providing & applying inhibition coats/system to exposed reinforcement bars after cleaning & removing scales and rust completely as specified by the manufacturer. Two component inhibitor Nitozinc Primer std of Fosroc or equivalent as approved by GE having Mix density of 2.4 and solid content 57(+/-3) Adhesive bond strength > 1.5 N/mm2, 40 microns DFT per coat or equivalent as approved by GE shall be used as per manufacturer’s specification in two coats including all labours, tools and machineries, plants, scaffolding, necessary surface preparation and necessary protection after and during work.
Note item No 3 & 4 : The work shall be carried out by the authorised applicator by the company. For measurement and payment purpose 20% of structure are of concrete shall be measured irrespective of number of bars. | 150 | SQUARE METRE | 200 ₹30,000 | 100 ₹15,000 Lowest | 450 ₹67,500 | 504 ₹75,600 | 450 ₹67,500 | 300 ₹45,000 | 610 ₹91,500 |
| 5.00 | M&L for mild steel TMT bars of any dia, cut to length, bent to shape required for rebarring in structure members like column, beam, slabs including cranking, bending and welding to existing main reinforcement all as specified and directed by Engineer-in-Charge | 350 | KILOGRAM | 90 ₹31,500 | 80 ₹28,000 Lowest | 90 ₹31,500 | 108 ₹37,800 | 95 ₹33,250 | 100 ₹35,000 | 178 ₹62,300 |
| 6.00 | M&L for drilling holes into exising concrete structure for anchoring of new rebar with 10 mm dia, Shear connectors at 0.5 Mt. c/c as directed by Engr-in-Charge and fixing with anchor resin grout Lokfix P (Fosroc Make ) or equivalent as approved by GE. Drilling hole diameter: 14 mm, Drilling hole depth: 100 mm including cleaning, cutting, fabricating, chemicals, tools, plants, machineries, labor, electricity, etc complete as directed by Engineer-in-charge. | 225 | KILOGRAM | 350 ₹78,750 | 120 ₹27,000 Lowest | 340 ₹76,500 | 126 ₹28,350 | 1,200 ₹2,70,000 | 300 ₹67,500 | 275 ₹61,875 |
| 7.00 | M&L for providing and executing injection / pressure grouting in cracks in the parent concrete by fixing PVC nipples at 150 mm to 200 mm distance or specified distances as directed and detailed specifications. Pressure grouting using low viscous epoxy grout Monopol of Krishna conchem or Conbextra EP10 (M) of Fosroc make or equivalent as approved by GE shall be done at required pressure etc. complete as per manufacturer instructions, labour, tools tackles etc complete as directed by Engr-in-Charge.
Note: (i) Payment shall be made on basis of quantity of actual grout consumed based on coverage area as per manufactures instructions.
(ii) The work shall be carried out by the authorised applicator by the company | 520 | KILOGRAM | 250 ₹1,30,000 | 175 ₹91,000 Lowest | 1,200 ₹6,24,000 | 999 ₹5,19,480 | 1,200 ₹6,24,000 | 1,400 ₹7,28,000 | 1,240 ₹6,44,800 |
| 8.00 | M&L for providing and applying bond coat on the prepared surface to receive new polymer mortar / polymer modified concrete, with two components epoxy based bonding coat in one full coat. Laying of reinforcement polymer mortar or micro concrete shall be completed within the overlay time of bonding coat. This coat act as bonding agent between old and new concrete and also acts as ‘barrier coat’ to the migration of chloride ions from host concrete. @ 2.6 sqm/lit or as per manufacture’s instruction to old concrete surfaces of columns, beams and similar structural members all as specified and as directed.
Make: FOSROC or equivalent as approved by GE
Note : The work shall be carried out by the authorised applicator by the company | 573 | SQUARE METRE | 250 ₹1,43,250 Lowest | 650 ₹3,72,450 | 725 ₹4,15,425 | 720 ₹4,12,560 | 650 ₹3,72,450 | 700 ₹4,01,100 | 700 ₹4,01,100 |
| 9.00 | M&L for non shrink, cementitous micro concrete (compressive strength minimum of M-40) mixed with 12.5 mm graded stone aggregate using Renderoc RG of Fosroc or equivalent as approved by GE by weight (18 Kg Aggregate : 25 Kg Renderoc RG) respectively (as per manufacturer’s instruction) laid in average thickness 80 to 100 mm in surface, including necessary water tight steel form work complete all as specified and directed. | 33 | CUBIC METRE | 20,000 ₹6,60,000 Lowest | 35,000 ₹11,55,000 | 35,000 ₹11,55,000 | 33,300 ₹10,98,900 | 42,000 ₹13,86,000 | 35,000 ₹11,55,000 | 49,880 ₹16,46,040 |
| 10.00 | M&L for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces complete all as specified and directed.
Make : Concure WB white of FOSROC or equivalent as approved by GE | 633 | SQUARE METRE | 150 ₹94,950 | 85 ₹53,805 | 75 ₹47,475 | 45 ₹28,485 Lowest | 120 ₹75,960 | 80 ₹50,640 | 52 ₹32,916 |
Tender Value
Refer Docs
EMD Value
₹3.9 L
Closing Date
31 Dec 2020, 6:00 pmClosed
Shri Abhay Manglik, SE, IDSE
HQ Commander Works Engineer No 2, Brichgunj, Junglighat Post, Port Blar-744 103
ADDITION AND ALTERATION TO BLDG NO P-66 TO P-71, P-305A (A COY COOK HOUSE), P-306A (B COY COOK HOUSE), P-315 (URC), P-322 (MT SHED), P-323 (TECH STORE), P-325 (MT GUARD ROOM), P-326 (MT OFFICE), P-482, P-483 (MT VEH SHED), P-203/01 TO 203/5 AT BRICH
2020_MES_400982_1
80199/E8
Open Tender
Civil Works
Item Rate
240 days
PORT BLAIR
A Class
8 documents required · 8 mandatory
₹2,000
GE Brichgunj
₹3.9 L
Yes
5 Jan 2021
5 Dec 2020
5 Jan 2021
5 Dec 2020
31 Dec 2020
24 Dec 2020
5 Dec 2020 - 12 Dec 2020
Amount
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard/dense Soil.
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 50 to 100 mm from column/ beams outer surface and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt, other foreign particles and removal of debris to a distance not exceeding 50m including necessary scaffolding etc, complete all as specified and directed.
M&L for cleaning of rust/ scales/corrosion from reinforcement bars using rust remover Reebakleens RR of Fosroc or equivalent as approved by GE. The material shall be applied to the rusted metal using brush and make leaving to dry for 30 mins & washing the surface with fresh water as required to exposed reinforcement bars complete all as specified and directed. Note : The work shall be carried out by the authorised applicator by the company
M&L for providing & applying inhibition coats/system to exposed reinforcement bars after cleaning & removing scales and rust completely as specified by the manufacturer. Two component inhibitor Nitozinc Primer std of Fosroc or equivalent as approved by GE having Mix density of 2.4 and solid content 57(+/-3) Adhesive bond strength > 1.5 N/mm2, 40 microns DFT per coat or equivalent as approved by GE shall be used as per manufacturer’s specification in two coats including all labours, tools and machineries, plants, scaffolding, necessary surface preparation and necessary protection after and during work. Note item No 3 & 4 : The work shall be carried out by the authorised applicator by the company. For measurement and payment purpose 20% of structure are of concrete shall be measured irrespective of number of bars.
M&L for mild steel TMT bars of any dia, cut to length, bent to shape required for rebarring in structure members like column, beam, slabs including cranking, bending and welding to existing main reinforcement all as specified and directed by Engineer-in-Charge
M&L for drilling holes into exising concrete structure for anchoring of new rebar with 10 mm dia, Shear connectors at 0.5 Mt. c/c as directed by Engr-in-Charge and fixing with anchor resin grout Lokfix P (Fosroc Make ) or equivalent as approved by GE. Drilling hole diameter: 14 mm, Drilling hole depth: 100 mm including cleaning, cutting, fabricating, chemicals, tools, plants, machineries, labor, electricity, etc complete as directed by Engineer-in-charge.
M&L for providing and executing injection / pressure grouting in cracks in the parent concrete by fixing PVC nipples at 150 mm to 200 mm distance or specified distances as directed and detailed specifications. Pressure grouting using low viscous epoxy grout Monopol of Krishna conchem or Conbextra EP10 (M) of Fosroc make or equivalent as approved by GE shall be done at required pressure etc. complete as per manufacturer instructions, labour, tools tackles etc complete as directed by Engr-in-Charge. Note: (i) Payment shall be made on basis of quantity of actual grout consumed based on coverage area as per manufactures instructions. (ii) The work shall be carried out by the authorised applicator by the company
M&L for providing and applying bond coat on the prepared surface to receive new polymer mortar / polymer modified concrete, with two components epoxy based bonding coat in one full coat. Laying of reinforcement polymer mortar or micro concrete shall be completed within the overlay time of bonding coat. This coat act as bonding agent between old and new concrete and also acts as ‘barrier coat’ to the migration of chloride ions from host concrete. @ 2.6 sqm/lit or as per manufacture’s instruction to old concrete surfaces of columns, beams and similar structural members all as specified and as directed. Make: FOSROC or equivalent as approved by GE Note : The work shall be carried out by the authorised applicator by the company
M&L for non shrink, cementitous micro concrete (compressive strength minimum of M-40) mixed with 12.5 mm graded stone aggregate using Renderoc RG of Fosroc or equivalent as approved by GE by weight (18 Kg Aggregate : 25 Kg Renderoc RG) respectively (as per manufacturer’s instruction) laid in average thickness 80 to 100 mm in surface, including necessary water tight steel form work complete all as specified and directed.
M&L for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces complete all as specified and directed. Make : Concure WB white of FOSROC or equivalent as approved by GE
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 20 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign matters, complete all as specified and directed.
M&L for application of 10 to 20mm thick in two layers with high build polymer modified cement mortar (1:2.5) mixed with 5 kg SBR per 50 Kg bag of cement in ceiling surface over a coat of bonding agent Nito Bond SBR in the ratio of 1:1:3 (1 Ltr SBR + 1 Ltr water + 3 kg cement) including applying three coats of white wash on exposed ceiling surface complete all as specified and directed. Note : The work shall be carried out by the authorised applicator by the company
Hardcore of broken stone of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified.
M & L for post construction anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12mm dia holes with cement sand mortar 1:2 to match existing floors.complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded aggregates) for foundations,filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC.1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete for drain and similar work, complete all as specified and as directed
.M&L for cement concrete in surface channel and drain in type C2 ,1:3:6(40 mm graded stone aggregate) finish even and smooth including form work ,complete all as specified and as directed
M&L PCC Type B0, 1:2:4 (using 12.5 mm graded stone aggregate) in roof kerbs, mud stops or chamfered on edges,complete all as specified and as directed .
M&L for PCC type B1 ,1:2:4 (using20 mm graded aggregate) in coping including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed
M&L for precast cement concrete solid block masonry with solid blocks using precast cement concrete type C1, 1:3:6(using 20mm graded stone aggregate), exc. 10cm in width, set in CM 1:4 complete all as specified.
M&L RCC M-30 (design mix )using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as directed.
M & L for RCC M-30 (design mix) using 20mm graded stone aggregated for chajja, fins, facia, etc., all as specified and as directed by Engineer-in-Charge.
M&L RCC M-30 ( design mix) using 20mm graded aggregate in foundations footings, plinth beams, bases for columns, etc all as specified and as directed by Engineer-in-Charge.
M&L RCC M-30 ( design mix) using 20mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span,all as specified and as directed by Engineer-in-Charge.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. all as specified and as directed
All as per serial item No 25 above, but add or deduct for each 25 mm girth or part thereof over or under 30cm girth complete all as specified and as directed
Supply only Integral water proofing compound
Cutting holes for inserting hold fasts in PCC block masonry built in cement mortar and making good disturbed portion in PCC type B1,1: 2 :4(using 20 mm graded stone aggregate) or in cement mortar 1:3 as required, depth of embeded portion exceeding half brick but not exceeding one brick for full brick walls, complete all as specified and as directed by Engineer-in-charge.
M & L for granite slab 18 -20mm thick as in cooking platform/ stair steps and riser , rounded on edge bedded in 15mm thick ,in cement mortor 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and as directed by Engineer-in-charge
Use and waste of formwork using steel shutter flat or curved to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter rough finished surfaces of concrete all as specified
Use and waste of formwork using steel shutter flat or curved to sides of concrete slab,chajjas,fins facia, para pets and similar work vertical or to batter fair finished surfaces of concrete all as specified
Use and waste of formwork using steel shutter flat or curved to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. fair finished surfaces of concrete all as specified.
S&F second class hard wood boarding 20mm thick planed on both side with butt joints fixed with nails in any situation (except flooring and skirting) as in eaves board complete.
S & F second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
S & F 35 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a).all as directed by Engr-in-Charge. Note :- Glass/Wire mesh shall be measured and paid separately
S & F 30 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a).all as directed by Engr-in-Charge. Note :- Glass/Wire mesh shall be measured and paid separately
S & F 30 mm thick second class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats all as specified.
S & F 35 mm thick second class hard wood, plain framed, panelled shutter (two panel) with lock rail with panels of 12mm thick timber flat on both sides ( feather edged). The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed by Engr-in-charge
S & F second class hard wood small fittings such as brackets, door stoppers etc articles not exceeding 200 cubic centimetre each, complete all as specified and as directed by Engineer-in-charge.
Taking down chowkats or frame with shutter (without taking off shutter from frame) area not exc 1.5 sqm each all as specified.
Taking down chowkats or frame with shutter (without taking off shutter from frame) above but are exc 1.5 Sqm but n.exc 4.00 Sqm all as specified.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC `C' channel having at PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and as specified.
Aluminium anodised barrel tower bolts type of extruded section and fixed of size 150 mm all as specified.
Aluminium anodised barrel tower bolts of extruded section and fixed of size 100 mm all as specified.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips to sheet, cast or extruded sections and fixing bolts or cast aluminium alloy and fixed all as specified.
Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 100mm Size all as specified.
Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 , 75 mm Size all as specified.
Continuous(piano) hinges, 40mm width of flaps (when open) made of brass bright finish etc complete all as specified.
Extruded Aluminium alloy handles, fabricated type, anodised of size150 mm long complete all as specified.
Extruded Aluminium alloy handles, fabricated type, anodised of size 100 mm long .
Drawer brass handles, projecting drop (50mm to 65mm) on screwed plate for kitchen cabinet shutters/drawers etc completed all as specified and directed.
S&F aluminium anodised tubular towel rail 20mm dia complete all as specified .
S&F in repairs Brass Chromium plated tubular towel rail, 20mm dia, D type, 60cm long, between flanges complete all as specified and as directed by Engineer-in-Charge.
S&F floor door stoper overall length of cover plate 140mm of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as specified.
S&F Door closer hydraulically regulated, aluminium extrected sec body designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg and fixed complete all as specified and directed.
Supply only aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples complete all as specified and directed by Engineer-in-Charge.
S & F aluminium powder coated (colour as directed) sections (minimum 50 micron) grey colour for frames and shutters(openable/fixed /slidingshutters) of door / window / ventilator/ partition including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, all as specified and as directed. Make : Jindal/Hindalco/ Indalco. Note:- Weight of various Aluminium sections shall only be considered for measurement for payment. However cost of rubber packing ,locking arrangement for sliding shutters and other consumable shall deemed to be included in the rate quoted . Glass panels, prelaminated particle boards, aluminium wire cloth aluminium grills, aluminium mongories as applicable will be measured and paid separately as supplied only.
S & F aluminium anodised sections (minimum 15 micron ) for frames and shutters(openable/fixed /slidingshutters) of door / window / ventilator/ partition including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, all as specified and as directed. Make : Jindal/Hindalco/ Indalco. Note :- Weight of various Aluminium sections shall only be considered for measurement for payment. However cost of rubber packing ,locking arrangement for sliding shutters and other consumable shall deemed to be included in the rate quoted . Glass panels, prelaminated particle boards, aluminium wire cloth aluminium grills, aluminium mongories as applicable will be measured and paid separately as supplied only.
S&F mild steel flat iron 40 x 3mm as in wind tie / hold fast including all necessary drilling, bolting or riveting etc., confirming to Fe 290. all as specified .
S&F Mild steel bolts exc 12mm n' exc 20mm dia , purpose made, with hexagonal or square head one end and screwed the other, or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long all as specified.
M&L mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified.
Mild steel TMT bars 6 to 8 mm dia., cut to length, bent to shape required, for stirrups or distribution bar including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified.
S & F rolled mild steel joist, channel, angle or tee sections/Hollow sqaure/rectangular sections, fixed independently, without connecting plates, etc. (Cut to ordinary lenghts i,e. within 20mm of the length indicated) in Fe 410-0W (gde E-250) quality A all as specified.
S&F plates plain channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment in Fe- 410-W(Gde E-250) quality B all as specified and directed.
S&F roof trusses (framed), trussed, purlins, trusses gantries, rails and fastenings and heavy bracket framing (beam,tee,angle,channel or flat sections) including distance pieces, cleats etc. in FE 410W-(Grade E-250) quality B all as specified and directed.
S & F MS steel work in tubular /post/trusses/purlin including special shaped washers base and bed plate cleat nut and bolt etc., complete using but welded tubes confirming to IS 1161- 1979 graded St 240 complete all as directed . Note for Item Ser No 64 to 67 : The structural design shall be approved by GE in writing before execution of work.
M&L steel rolling shutters, with thickness of lath1.25 mm without ball bearing, as specified including top cover, anchoring rod, hasp and staple and applying two coats of synthetic enamel paint over one coat of primer; erected in position as indicated, complete all as directed.
M&L false ceiling with aluminium grid work (size of grid 605x605mm) with 35x25x1.5mm main tee and 25x25x1.4mm, cross tee and wall angle and suspended with 3.15mm dia, GI wire, hooked to roof with needful adjustment bolts at an interval of 1.20m, centre to centre staggered and board with Eco board, decorative type, size 600x600x4mm thick, finished with two coats of oil bound distemper over a coat of primer on exposed surfaces, complete all as specified and as directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof covering,ridges/cladding to wall, fixed with self tapping screws as specified.
Material and Labour for waterproofing treatment using APP modified polymeric membrane over existing RCC roof slab with following specifications including cleaning of the surfaces to receive the treatment including taking down existing roof treatment cleaning scrubing down with watercomplete as directed by Engr-in-Charge :- (a) Applying bitumen primer @ 0.4 Litres/Sqm with density of 0.87 to 0.89 Kg/Litre at 25 degree C on the prepared dry roof surfaces. (b) Applying a coat of hot blown bitumen grade 85/25 @1.2Kg per SqM (c) Laying 3 mm (minimum) thick APP membrane weight not less than 3.50 kg per sqm by torch application with minimum 10 cm side lap and 15 cm end lap. The laying of membrane shall be got done through an authorised applicator of manufacturer of APP membrane only.
S & F 19/20mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination & other side balancing white lamination, fixed with screws including 4mm thick teak wood beading on edges and fixed in kitchen cabinet shutters/partition or timber frame work etc completed all as specified and directed by Engineer-in-charge.
Supply only 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on one side with decorative choice lamination and other side white lamination fixed to Aluminium frame etc all as specified and directed by Engineer-in-Charge .
S & F 12mm thick Veneered decorative ply wood, grade I (with BWR resin) decorative veneers on both faces, fixed with scews including 4mm thick teak wood beading and fixed in kitchen cabinet shutters/partition or timber frame work etc completed all as specified and directed by Engineer-in-charge. .
M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement including crushed stone dust 40mm thick for chushioning and no pigment over cushioning complete all as specified and as directed. Note :- Sand cushioning shall be measured and paid separately as supply only under relevant item.
M&L for rendering in CM 1:4, 10mm thick with Water proofing compound 3% by weight of cement finished even and fair all as directed by Engineer-in-Charge. Note : Water proofing compound shall be measured and paid seperately.
M&L polished kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including screed bed 20 mm thick in CM 1:4 complete all as specified and directed.
M&L polished kota stone 20-25 mm in walls thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including screed bed 15 mm thick in CM 1:4 complete all as specified and directed.
M&L PCC type B- 2, 1:2:4 (40mm graded aggregate) 150 mm thick as in sub floors,sub base ,floors and pavings,etc all as specified.
M&L PCC type C2,1:3:6 (Using 40 mm graded stone aggregate), 75mm thick as in plinth protection, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed.
M&L PCC type C2 ,1:3:6(using 40 mm graded stone aggregate) as in sub bases to floor 75 mm thick all as specified .
M&L PCC type C2,1:3:6 ( using 40 mm graded stone aggregate) as in sub bases to floor 100 mm thick all as specified .
M&L PCC type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab 40 mm thick all as specified
S & F designer coloured glazed ceramic tiles 300mm x 450mm, 7-8mm thick on vertical surfaces such as skirting & dados etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces etc including backing coat of 10mm thick CM 1:3 all as specified.
M&L for coloured joint free non Skid ceramic tiles 7 to 8mm thick (square) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified .
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15 mm thick in CM 1:4.complete all as specified.
M&L for non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm and not exceeding 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15mm thick screed bed in CM 1:4 complete all as specified.
M&L vitrified ceramic tiles light shade 600mm x 600mm ,10mm thick , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over and including screed bed 15 mm thick in CM 1:4 all as specified.
M&L chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry in floors finished with grey cement and pigment over cement screed 20 mm thick in CM 1:4 all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing coat) and rubbish off the premises all as directed.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement all as specified. .
M & L rendering 5 mm thick in CM I:4 over backing coat of 10 mm thick in C M 1:6, finished even and smooth without using extra cement etc complete, cement mortar for rendering 5mm thick shall be mixed with water proofing compound @3% by weight of cement and finished even and smooth without using extra cement all as specified and directed (WPC shall be measured and paid separately).
M&L applying cement slurry 3 kg/sqm as in wear proof topping and rendering 5 mm thick in CM 1:3 finished even and smooth without using extra cement on ceiling all as specified.
.M&L for 15 mm thick rendering on fair face of brick or concrete surfaces on walls in CM 1:4 finished even and smooth without using extra cement all as specified.
M&L extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in drip moulds n. exc 15 cm in width or girth for RCC chajjas etc ; including cutting to edges, all mitres and stopped ends all as specified and directed.
Taking down cement plaster of any description from wall/ceiling including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L two coats of acrylic emulsion paint including preparation of old decorated surfaces, plastered or unplastered surfaces of ceiling complete including taking down of existing treatment all as specified and directed by Engineer - in -Charge.
M & L for preparation of new plastered ceiling surfaces and applying two coats of acrylic emulsion paint over a coat of primer all as specified and directed.
M&L two coats of acrylic emulsion paint to new plastered wall surfaces over a coat of primer incl preparation of surfaces
M&L acrylic emulsion paint two coats including preparation of surfaces old decorated, plastered or unplastered surfaces of wall complete including taking down existing treatment all as specified and directed by Engineer - in -Charge.
M&L applying two coats of cement base paint over a coat of primer on new plaster or untreated surfaces on walls including preparation of surfaces all as specified.
M&L applying two coats of cement base paint on old plaster or untreated surfaces on walls including preparation of surfaces all as specified.
Supply only sheet glass 4 mm thick ordinary quality glass pane n.exc 0.50 sqm in each panes. and glazing with PVC rubber gasket suitable for aluminium framing complete all as specified and as directed.
Supply only 3 mm thick figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane.
M&L preparation of new or previously untreatead wood and wood based surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified.
M&L preparation of new or previously untreatead wood and wood based surfaces of any description n exc 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified.
M&L for one coat of synthetic enamel paint including perparation of old wooden surfaces over 10 cm width or girth complete all as specified.
M&L preparation of old painted wood and wood based surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) complete all as specified.
M& L preparation of wood and wood based materials and treating ends of posts, backs of chowkats etc area tarred exceeding 0.10 Sqm but not exceeding 0.50 Sqm each treated with tar or coal tar black paint, complete all as specified and as directed by Engineer-in-charge.
M/L two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of new or previously untreated steel surfaces of any description over 10cm width or girth complete all as specified.
M&L one coat of synthetic enamel paint including preparation of previously treated steel surfaces of any description, not otherwise described, over 10 cm width or grith all as specified and directed.
M&L preparation new steel surfaces of any description n.exc 10cm width or girth when unconnected with other painting or when painted in a different tint, and applying two coats of synthetic enamel paint over a coat of zinc chrome primer, complete
Taking up or down, 15mm dia bore GI tubing, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 20 mm dia bore GI tubing ,including removal from site, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 25mm dia bore GI tubing, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Rotational moulded polyethlene water storage tank, double layered 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I complete including float valve 25mm dia suitable for inlet all as specified and directed.
S&F Bib tap cast copper alloy chromium plated, 15 mm dia with crutch or butter-fly handle, screwed down, screwed for iron pipe or for brass ferrule etc all as specified and directed.
S&F Pillar taps , cast copper alloy , with capstan heads , chromium plated , screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm and fixed in repairs, all as specified.
S&F stop cock, cast copper alloy chromium plated, 15 mm dia screwed down high pressure, with long screwed both ends for iron pipe or for unions complete all as specified and as directed
S&F PVC connection both end brass union 15 mm dia & check nuts of length 450 mm long.
M&L 110mm bore PVC(SWR) pipe in any length with rubber rings joints, fixed in walls complete all as specified and directed by Engr-in-Charge
M&L 75mm bore PVC(SWR) pipe in any length with rubber rings joints, fixed in walls complete all as specified and directed by Engr-in-Charge
S&F PVC(SWR) bends bore of pipe 110mm any radius all as specified and directed.
S&F PVC(SWR) bends bore of pipe 75mm any radius all as specified and directed.
S&F PVC(SWR) 110mm dia single(single T) equal or unequal complete all as specified and directed.
S&F PVC(SWR) 75mm dia single(single T) equal or unequal complete all as specified and directed.
S&F PVC(SWR) 110mm dia double (double T) equal or unequal complete all as specified and directed.
S&F PVC(SWR) 110mm dia vent Cowls 110mm bore of pipe all as specified and directed.
M&L cast iron Nahani trap,75mm dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repairs sink with drainage board, made up of stainless steel, 1mm thick for kitchen or laboratory with plug washers and waste fittings, including bedding in cement mortar 1:3 into dwarf wall or cantilever brackets and connecting union to pipe, over all size 915mm x 460mm, bowl size 410 x 330 x 160mm etc, complete all as specified and as directed by Engineer-in-Charge.
S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified.
S & F in repairs PVC flushing cistern 10 litres capacity syphonic action type, low level, white with inlet, ball valve, float, handle and flush pipe, etc complete all as specified and directed.
S&F in repairs urinal vitreous china white bowl, flat back size of 465x355x265mm with grating and union for discharge pipe including fixing plug and bedding in CM 1:2 all as specified.
S&F in repairs vitreous China wash hand basin of size 550 x 400mm white flat back including chromium plated pillat tap, waste coupling, including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed by Engineer-in-Charge.
S&F stainless steel, plate rack of size 750 x 780 mm with all fittings as directed by Engineer-in-Charge.
S&F 3- layer PP-R Polypropylene random copolymer) pipes SDR 11, UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings fixed on floor/wall/ceiling/laid in trenches complete all as specified and as directed for the following sizes:-
20mm outer dia pipes
25mm outer dia pipes
32mm outer dia pipes
50mm outer dia pipes
S&F 25mm external dia PPR Ball valves complete all as specified and as directed by Engineer-in-charge.
S&F in repair shower arm 190mm long light body with wall flange & exclusive shower single flow with revolving ball joint,complete all as specified and as directed by Engineer-in-Charge.
Scarifying or picking gravelled, macadam or bituminous mcadan surfaces in area n.exc 400 sqm and depth exceeding 50mm and not exceeding 100mm all as specified.
M&L for 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compund, grade 'B' etc., all as specified and directed.
M&L for contraction (dummy) joints 50 mm deep(ie 1/3 rd of total slab thickness) x 10mm wide filled with sealing compund, grade 'B' etc., all as specified and directed.
Demolition of precast cement concrete block as in wall, drain etc built in cement mortar all quoins, arches piller etc. complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) all as specified and directed.
Demolition of cement concrete reinforced of any description and in any position complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete of any description and in any position complete all as .as directed .
Demolition of reinforced cement concrete such as roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified and all as directed.
Dismantling boarding, any description, fixed in any position with nails all as directed .
Dismantling mild steel work of any description not otherwise provided all as directed .
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings all as directed ..
Dismantling of ceiling boards of any description and any thickness, fixed in any position including frame work if any , complete all as directed .
Dismantling of CI drain pipes,50 to100 mm dia, jointed in cement motar all as directed .
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including sperading and punning down including watering consolidation complete all as specified and directed for cable protection. Note:- Punned thickness shall be measured and paid.
S&F GI tube light grade 40mm bore galvanised with all fittings for cable protection laid in trenches including taking down of old U/S pipe complete all as specified and as directed. .
Dismantling and taking up old LT UG cable of any size and description all as directed.
M & L for cutting existing 50mm GI water mains and insertion of Tee 50x50mm including all necessary GI specials for taking branch connection for PR-R pipe 50mm dia with all joints and testing complete all as directed and specified by Engineer-in-charge.
S&F unreinforced precast cement concrete cable cover Class LV, Type I, flat, size 250mm x 150mmx40mm in trenches for cable protection embossed with Electric on the top surface complete all as specified and directed.
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of following cross sections all as specified and directed:-
Cross section area 2 core 6 sqmm .
Cross section area 2 Core 10 sqmm .
Cross section area 4 Core 10 sqmm .
Cross section area 4 Core 16 sqmm .
Cross section area 3.5 Core 25 sqmm .
Supply install ,testing and commissioing of LT feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type,dust and vermin proof (CPRI approved) with 200 A rated TPN bus bar including PVC heat shrinkable sleeve powder coated painting, TPN 63 Amp MCCB, 16 KA as incomer,outgoing SPN MCBs 6 to 32 Amps 10 KA -03 Nos, TPN, MCB 6-32A, 10 KA-4 Nos complete all as specified and as direted.
Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including non metallic rigid PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper single core FRLS cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: -
One light point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on independent board.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper single core FRLS cable 1100Volt as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: -
One light point point controlled by one switch
One Exhaust fan point controlled by one switch
One fan point controlled by one switch and one regulator
One bell point controlled by one switch
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No.163 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 2.5 Sqmm size and 2.5 Sqmm earth continuty conductor, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed Engineer-in-Charge
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed by Engineer-in-Charge
Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge.
Supply and fix bell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch socket outlet 3 & 2 pin (mult pin) 5 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge
S & F in Single Pole and Neutral enclosure with two pin earth Plug and Socket complete with one MCB SPN 16 Amps 10 KA fixed on wall/concealed in wall complete all as specified and as directed.
S&F metal enclosure distribution board SPN, 4 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed.
S&F metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed.
S&F MCB single pole, 240 volts, 5 to 32 Amps 10 KA all as specified and as directed.
Taking down and refixing only serviceable MCB single pole, 240 volts, 5 to 32 Amps 10 KA all as specified and as directed.
S&F MCB SPN 240 volts, 5 to 32 Amps 10 KA all as specified and as directed.
S&F TPN MCB 6-32A, 16 KA all as specified and as directed.
S&F ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specified and as directed by Engineer-in-Charge
Taking down and refixing only serviceable ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specified and as directed by Engineer-in-Charge
Taking down and refixing ceiling fan 1200 mm sweep and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed
S&F ventilating fan Celso suitable for on working of AC 230 V ,50 Hz 200 mm sweep ,incl louvers Wall Cutting/Block masonry/Cement mortar incl labour complete all as specified. Make as approved by GE .
Taking down and refixing old serviceable exhaust fan and connecting up including provinding of cable from ceiling rose/connector to fan complete all as specified and as directed.
Taking down and refixing 4 feet LED fitting including accessories and connecting the twin core cable to existing ceiling rose all specfied & directed .
S&F New generation energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LED 25 w as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
S & F LED mirror light fitting 1 x 10 Watt provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block,complete all as specified and directed by Engineer-in-Charge
S&F sheet metal enclosures Loadline distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs 32A MCB, TPN, 10 KA as incomming complete all as specified and as directed including taking down old MCB DBs complete. Note:-MCB will be measured and paid separatly under relevent item .
S&F fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge.
M & L for sub main wiring complete with two runs of 4 Sqmm, FRLS, single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs etc with one run of 4.0 sqmm FRLS single core multistranded copper conductor 1100V as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable, one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
M & L for sub main wiring complete with two runs of 6 Sqmm, FRLS, single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6.0 sqmm FRLS single core 1100 volt, multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Supply and fixing GI wire 4 mm dia for earting purpose complete all as specified and directed by the Engr-in-Charge
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S&F 25 mm bore PP-R valve(brass insent) ISI Marked, screwed both ends suitable for PR-R pipe. complete all as specified and directed.
S&F 50 mm bore PP-R gate valve ISI Marked, screwed both ends suitable for complete all as specified and directed.
M & L for Construction of valve chamber of 600 mm x 600 mm x 600 mm internal size suitable for sluice valve,with PCC 1:4:8 type(D2) (using 40 mm graded aggregate) for foundation and hollow block masonary wall 200mm thick in cement mortar (1:4), 40 mm thick PCC (1:2:4) type B1 (using 20mm graded aggregate) coping, rendering in CM 1:4, 15 mm thick including provision of mild steel sheet cover 3 mm thick on 40x40x6mm angle iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and includng necessary earth work on any type of soil etc. including removal of surplus soil and rubbish not exceeding 50m distance, including demolition of old valve chambers complete all as directed and specified by Engineer-in-charge.
Supply, installation, testing and commissioning horizontal open well submersible pump 5 HP , 3.7KW SS body discharge 12.5 LPS, head 20M, 380V, 2900 rpm. The rate are inclusive of suitable DOL starter panel out door type as per manufacture recommendation and foundation complete. Make Kirloskar, Model KOS-527 + *or equivalant in sinitac/CG/KSB/Grumfoss, Jyoti Note : Contarctor shall be given guarantee for two years from the date of completion to GE.
Supply and laying on ground HDPE pipes with complete jointing materials & accessories etc of size 75mm OD pressure rating of PN-16, PE-100, pressure 12.5Kg/Sqcm as per BIS 4984-2005 all as specified. Note :- Excavation and earth work shall be measured and paid separately.
Supply and laying on ground HDPE pipes with complete jointing materials & accessories etc of size 63mm OD pressure rating of PN-16, PE-100, pressure 12.5Kg/Sqcm as per BIS 4984-2005 all as specified. Note :- Excavation and earth work shall be measured and paid separately.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm using excavated soil.
Removing Excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.
Gulmarg Electrical Service
Vandana Enterprises
BHARAT MULTITECH INDUSTRIES PVT LTD
Sree Tirumala Enterprises
KAPOOR AUTOMOBILES
NAWAZ CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .