Tender Value
₹39.8 L
EMD Value
₹79,700
Closing Date
6 Apr 2021, 6:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIR/MAINT OF TRANSFORMERS , FILTERATION OF TRANSFORMER OIL , REPAIRS/RENEWALS OF HT AND LT CABLES AND CONNECTED WORKS UNDER AGE E/M-II IN GE (C) KIRKEE
2020_MES_377426_4
CA No CWE/ KKE/ TOKEN-12 OF 2020- 21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹79,700
Yes
24 Jun 2021
25 Mar 2021
8 Apr 2021
25 Mar 2021
6 Apr 2021
25 Mar 2021
25 Mar 2021 - 27 Mar 2021
Amount
Dismantling and taking out steel poles/struts of any size including excavation & earthwork complete all as specified and as directed.
Supply and erection of steel tubular swaged poles welded with cast iron base plate of size 30cmx30cmx6mm thick finial taper plug bolts nuts & screws as specified type 410 SP 55, 11m long in truly vertical position till setting of PCC foundation complete including painting with two coats of aluminium paints of approved quality over one coat of red oxide primer as on exposed surfaces & two coat bituminous paint for embedded portion complete all as specified and as directed. Note :- Excavation of post hole, PCC required for foundation and coping will be measured & paid under relevant items of Sch 'A'.
M&L for foundation for Tubular swaged type Pole including excavation of size not less than 0.65X0.55X1.95 mtr and getting out for pole foundation including filling in with PCC type D2 1:4:8 with 40 mm graded stone aggregate of size 0.65X0.55X 0.15mtr as in lean concrete and including Coping of pole with PCC type C1 1:3:6 with 20 mm graded aggregate (of size-0.65x0.55x1.8mtr below G.L.+0.45x0.45x0.45 mtr above G.L with fine finishing) and including removing surplus soil to a distance n.exceeding 50 m and making good surface complete all as specified and as directed.
Supplying, installing, testing and commissioning HT 22 KV, 400 Amp outdoor type gang operated single air-break switch, triple pole, tilting type, vertical mounting, mechanically operated consisting of hot dip galvanised channel iron base having 2 Nos 11 KV Post type insulator in stack - 3 stack per phase, copper or copper alloy high pressure heavily tinned contacts, flexible copper braided tape ,MS arcing horns capable of breaking the magnetizing current with operating mechanism worked from ground level complete with horizontal connecting square bar, GI pipe of size not less 25mm dia, medium grade and of suitable length as down rod levers coupling & operating handle with locking arrangement connected with new ACSR conductor (jumper) - set of 3 duly logged incoming and out going with steel nut bolts and washers including dismantling and taking out old switch and connections complete complying to IS 9921/1985 (Part I to IV) or its latest amendment all as specified and directed by Engr-in-Charge. NOTE - The quoted rate is deemed to be inclusive of cost of cutting, welding, drilling etc. and other jobs including. cost of nut, bolts, washers, etc. minor items required for the efficient operation of GOD. and removing of old GOD complete all as specified and as directed.
Supplying, installing, testing and commissioning outdoor type gang operated double air-break switch, triple pole, centre rotating with earth switch Turn N Twist type, mechanically operated with blades rotating in horizontal plane having live parts shall be of anti-rusting and non-corrosive metal with MS channel insulators base (not less than 100x80x550MM or as per manufacturers size), having current carrying components of hot galvanised non-ferrous, 02 post type suitable size and rating insulators (as per OEM) stacks per pole provided with double roller or double ball-bearings so designed so to having simultaneous make and break of all phases, having handle for manual operation made of 25 MM dia GI pipe; Line earth switches shall consist of three earthing links per isolator with each grounding blade provided with the flexible copper connections of suitable size (as suggested by OEM) and of adequate length for connection between the operating shaft and the frame complete and having following specifications complete all as specified and as directed including dismantling and taking out old switch and connections complete - (a) Nominal voltage : 22 kV (b) Maximum voltage : 24 kV (c) Frequency : 50 Hz (d) Number of phases : 3 (e) Solidly earthed, (f) Rated current (Amps.) : 400 NOTE - The quoted rate is deemed to be inclusive of cost of cutting, welding, drilling etc. and other jobs including cost of nut, bolts, washers, etc. minor items required for the efficient operation of GOD and removing of old GOD from site complete all as specified and as directed.
Supply and install drop out lift of HT 22 KV, 200 Amps fuse link consisting of channel iron base having 2 Nos 11 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphorous bronze contact complete manufactured as per latest IS complete all as specified and as directed. NOTE - The quoted rate is deemed to be inclusive of cost of cutting, welding, drilling etc. and other jobs including cost of nut, bolts, washers, etc. minor items required for the efficient operation of DO fuse unit and removing of old DO unit
Supply and laying in replacement, in trenches /ducts/fixing on pole/STR with suitable size of GI clamps made out of GI strip 32 mm x 6 mm, XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 core x 120 sqmm with aluminium conductor suitable for 22 KV (E) grade as per relevant IS including latest amendment for IS testing, commissioning along with S&F for HT cable route indicator for every 100 m or at turning with suitable PCC Foundation of PCC 1:3:6 type C1 complete all as specified and as directed including taking out old burnt out cable alongwith cable covers. Note:- (a) Earth work, EHV cable cover, sand cushioning & GI pipe will be measured and paid separately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above.( C) The cost of straight through joint required for laying of new cable continuously shall be included in the rate of cable in RM.
Supply, laying in replacement, in trenches /ducts/fixing on pole/STR with suitable size of GI clamps made out of GI strip 32 mm x 6 mm, XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 300 sqmm with aluminium conductor suitable for 22 KV (E) grade as per relevant IS including latest amendment for IS testing, commissioning along with S&F for HT cable route indicator for every 100 m or at turning with suitable PCC Foundation complete all as specified and directed including taking out old burnt out cable along with cable covers. Note:- (a) Earth work, EHV cable cover, sand cushioning & GI pipe will be measured and paid separately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above. ( C) The cost of straight through joint required for laying of new cable continuously shall be inclued in the rate of cable in RM.
Excavation in trenches for not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth n.exc.10 Sqm on plan and getting out in soft/loose soil including taking out faulty cable and cable covers and GI pipe complete all as specified and directed. Note: The contractors are advised to visit the site before quoting the rate as almost all area is paved & rockey area.
Supply, spreading and leveling 20mm graded crushed stone aggregate in various E&M installations complete all as specified and as directed.
M&L for spreading, filling in and mixing Fine aggregate (sand/stone dust) as cushioning to underground HT cable complete all as specified in SSR Part-I and as directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat, size 300mmx 180mm x 40mm complete all as specified and as directed.
Dismantling of ACSR conductors of service feeder or distribution span complete all as specified and directed.
M&L for drawing bus bar 3 phase with aluminium conductor, steel reinforced DOG (size 1 of 6/1 x 4.72 mm) complete all as specified and as directed.
M&L notice plate of 1.6 mm thick mild steel sheet vitreous enameled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 22 KV of size 25 x 20 cm.
Dismantling of unserviceable cross arms of MS Chanel/angle sections etc complete all as specified and directed.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat one under coat and two finishing coat of aluminium paint complete all as specified and as directed.
Dismantling of unserviceable insulator any type and any size complete all as specified and as directed.
M&L for disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 22 KV complete all as specified and directed.
M&L for pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut of 22 KV grade complete and as specified and directed.
M&L for pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut of 11 KV grade complete and as specified and directed.
M&L for fixed type top contact for DO fuse units 22 KV, 400 Amp in replacement suitable for fixing on existing insulators or as per existing shape & size complete all as specified and directed.
M&L for fixed type bottom contact for DO fuse units 22 KV 400 A in replacement suitable for fixing on existing insulators or as per existing shape & size complete all as specified and directed.
S&F Male contact (Gun metal) suitable for vertical operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete all as specified and directed.
S&F Female contact (Gun metal) suitable for vertical operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete all as specified and directed.
S&F Tinned copper flexible jumpert (Gun metal) suitable for vertical operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete all as specified and directed.
S&F MS Jumper carrier (Gun metal) suitable for vertical operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete all as specified and directed.
S&F Back connector plate suitable for vertical operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete all as specified and directed.
S&F Fixed contact gunmetal assembly suitable for horizontal operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete satisfaction of Engr-in-Charge complete all as specified and directed.
S&F Fixed Moving contact pipe/streep gunmetal assembly suitable for horizontal operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete satisfaction of Engr-in-Charge complete all as specified and directed.
S&F Fixed Arching horn suitable for horizontal operating type GOD 22 KV grade, 400 Amps rating in position as in replacement including testing and commissioning to the complete satisfaction of Engr-in-Charge complete all as specified and directed. NOTE :- rate quoted for item No 27 to 33 are deemed to be included any nut bolt,washers or any hard ware required for fixing the contacts and no any extra cost shall be given for this.
Dismantling rusted/unserviceable GI pipe, operating handle with bracket of any size of GOD complete all as specified and directed.
M&L GI pipe of size not less 25mm dia, medium grade, as down rod levers coupling & operating handle of the existing GOD cut to suitable length including fixing up the same and commissioning of the respective GOD complete. NOTE - The quoted rate is deemed to be inclusive of cost of threading, cutting of pipe include cost of nut, bolts, washers, etc. minor items required for the efficient operation of GOD.
S&F galvanized steel pipe medium grade 100mm dia with including fittings complete as specified and directed.
M & L for servicing, greasing, cleaning of GOD, adjustment of its operation, cleaning and checking (for any type of damage) of insulators and lightening arresters incl. tightening of all loose nuts & bolts on the HT structure at site complete all as specified and directed by Engineer-in-Charge. NOTE :- 1. All the necessary tools, tackles and ladder shall be arranged by the contractor for the subject work. 2. Contractor has to arrange for necessary cleaning agent (petrol, diesel, CRC 2-26 etc.) and lubricating material like petroleum Jelly, grease, oil and lubricating sprays if any, as required for subject work. 3. Major spares required to be replace during servicing will be measured and paid under relevant item as specified in the schedule here forth.
S&F HT bushing with brass spindle nut bolt washers etc. For 100/ 250 KVA transformer as per existing size and shape complete all as specified and directed.
S&F HT bushing with brass spindle nut bolt washers etc. for 500/750 KVA transformer as per existing size and shape complete all as specified and directed.
S&F HT bushing with brass spindle nut bolt washers etc for 1000/1250 KVA transformer as per existing size and shape complete all as specified and directed.
S&F HT bushing with brass spindle nut bolt washers etc. for 1500 KVA transformer as per existing size and shape complete all as specified and directed.
S&F LT bushing with brass spindle nut bolt washers etc. for 100/250 KVA transformer as per existing size and shape complete all as specified and directed.
S&F LT bushing with brass spindle nut bolt washers etc. for 500/750 KVA transformer as per existing size and shape complete all as specified and directed.
S&F LT bushing with brass spindle nut bolt washers etc. for 1000/1250 KVA transformer as per existing size and shape complete all as specified and directed.
S&F LT bushing with brass spindle nut bolt washers etc. for 1500 KVA transformer as per existing size and shape complete all as specified and directed . Note : 1 .HT/LT bushing of transformer to be fixed in replacement. 2 . The rates quoted is deemed to be included the cost of necessary labour charges for draining out transformer oil, opening of top cover by unscrewing nut, bolts washers and suitable size pad type bus bar aluminium and nut patch washers etc and refixing/refilling of etc complete.3. The cost of neoprene gasket and transformer oil if required shall paid in relevant item of this schedule.
S&F in renewal silica jell breather assembly for indoor/outdoor transformer of capacity up to 500 KVA complete all as specified and directed . Note : The rates quoted is deemed to be included the cost of necessary labour charges and misc items like GI sockets reducer bend etc required for fixing .
S&F in replacement silica jell breather assembly for indoor/outdoor transformer of capacity 750 to 1500 KVA:- Note : The rates quoted is deemed to be included the cost of necessary labour charges and misc items like GI sockets reducer bend etc required for fixing .
S&F Neoprene top cover gaskets suitable for 100 to 500 KVA transformer complete all as specified and directed .
S&F Neoprene top cover gaskets suitable for 750 to 1500 KVA transformer complete all as specified and directed .
Dehydration including filtration and cleaning of transformer oil by dehydrating machine including testing of sample before and after dehydration and filtration all as specified and directed. Note: Contractor to arrange the dehydration machine and testing kit without any extra cost to Govt.
Supply & Filling /pouring of transformer oil of low viscosity having dielectric strength not less than 60 KV (dielectric strength test should be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site) complete all as specified and directed .
S&F in Repairs Dial type temperature gauge with suitable spindle dia, dual calibration in degree celsius and degree Fahrenheit, range 0 to 100˚c and equivalent degree Fahrenheit complete with S&F capillary tube and sensor complete all as specified and directed .
M&L for replacement of existing unserviceable silica Jell granules with new Self-indicating Orange to Green Silica Gel granules from transformer breather assembly complete all as specified and directed .
M&L for taking down burnt jumpers and M&L for jumper connection between GOD and drop out fuses and transformers with Jumpers made with 120 sqmm copper conductor cable single core 1.5 mtr long with copper lug heavy duty crimped both ends and PVC sleeves ,GI / steel high tension nut bolt washer etc. complete all as specified and directed.
S&F DO fuse 10 to 20 Amp Cap with 45 CM long copper connecting wire complete all as specified and directed .
S&F DO fuse 40 to 60 Amp with 45 CM long copper connecting wire complete all as specified and directed .
S&F DO fuse 100 Amp with 45 CM long copper connecting wire complete all as specified and directed .
M&L in repairs 'T' type connector made out of cast aluminium suitable for ACSR conductor complete all as specified and directed.
M&L in repairs 4 'U' bolt hardware made of cast aluminium suitable for end disc. insulator complete all as specified and directed.
M&L in repairs Heat shrinkable outdoor type end termination cable jointing kit suitable for earthed 3 core 120/185 sqmm HT 22KV XLPE aluminium conductor cable including disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit including testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/M-Seal/Denson. NOTE- a. The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. b. Contractor has to arrange proper electrical shutdown after informing to department concerned.
M&L in repairs Heat shrinkable indoor type end termination cable jointing Kit suitable for earthed 3 core 120/185 sqmm HT 22KV XLPE aluminium conductor cable including disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit including testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/M-Seal/Denson. NOTE- a. The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. b. Contractor has to arrange proper electrical shutdown after informing to department concerned.
M&L in repairs Heat shrinkable indoor type end termination cable jointing Kit suitable for earthed 3 core 300 sqmm HT 22KV XLPE aluminium conductor cable including disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit including testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/M-Seal/Denson. NOTE- a. The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. b. Contractor has to arrange proper electrical shutdown after informing to department concerned.
M&L in repairs Heat shrinkable outdoor type end termination cable jointing Kit suitable for earthed 3 core 300 Sqmm HT 22KV XLPE aluminium conductor cable including disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit including testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/M-Seal/Denson. NOTE- a. The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. b. Contractor has to arrange proper electrical shutdown after informing to department concerned.
M&L in repairs Heat shrinkable straight through cable jointing kit suitable for earthed 3 core 185/120 sqmm HT 22KV XLPE aluminium conductor cable including. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit including testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/ XICON/ M-Seal/Denson. NOTE- (a). The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. (b). Contractor has to arrange proper electrical shutdown after informing to department concerned. (c). Cost of connected excavation, soil removal, returning filling in, sand cushioning and cable covers will be measured and paid in the respective items of the Schedule.
M&L in repairs Heat shrinkable straight through cable jointing kit suitable for earthed 3 core 300 sqmm HT 22KV XLPE aluminium conductor cable including. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit including testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/ XICON/ M-Seal/Denson. NOTE- (a). The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. (b). Contractor has to arrange proper electrical shutdown after informing to department concerned. (c). Cost of connected excavation, soil removal, returning filling in, sand cushioning and cable covers will be measured and paid in the respective items of the Schedule.
Disconnecting HT/LT XLPE cable of any size from structure/pole/transformer/MOCB/LT Panel for finding fault and M&L for defect rectification HT/LT cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The fault locating equipments will be brought to site within the 12 hours of instruction from Engr-in-Charge complete all as specified and as directed. Note :- Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and has to be rectified within 12 hours after notification, failing which Rs 500/- per day per complaint will be recovered from the dues to the contractor.
Disconnecting HT/LT terminations/cables, connected earthing strips from transformer, taking down the transformer from plinth/platform, loading it on a vehicle, transporting the same to a new location as directed by Engr-in-Charge, unloading and placing the transformer on plinth/platform, connecting HT, LT and earth termination connections, charging, testing and commissioning the transformer of rating up to 1500 KVA complete all as specified and as directed. NOTE - (a). Quoted rate is deemed to be inclusive of all items, not specified above, required for efficient installation and operation of transformer. (b). Any damage/loss to govt property will be make good by the contractor at his own cost. (c). On receipt of complaint the Job shall be completed within 24 Hrs failing to which Rs. 1000/- per day will be recovered as penalty.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 Mpa working pressure complete all as specified and as directed. NOTE - (a). Cost of cutting out of trench for accommodating the machine and making good to the surface after completion of the job are deemed to be inclusive in the quoted rate. (b). Contractor has to rectify any damage to cables, pipes or other govt. property free of cost to the complete satisfaction of Engr-in-Charge. (c). Any extra excavation or the any other connected jobs required other than as mentioned in the scope of work will be measured and paid under the relevant items of this schedule.
Disconnecting HT/LT and earth termination connections of electric outdoor/indoor type transformer of capacity up to 1250 KVA and lowering down/getting out from 2/4 pole structure/PCC platform/inside sub station for major repair/minor repair , loading into the vehicle, transporting to and fro the same to workshop for carrying out repairs and reconnecting HT/LT connections at site after repair and charging the transformer on load, commissioning and testing including insulation testing at site complete all as specified and as directed. NOTE - Rate is deemed to be inclusive of transportation, T&P and manpower required.
Draining out transformer oil, dismantling top cover along with conservator tank, taking out core and coil assemblies after disconnecting connections, rewinding of burnt out HV/LV coil with same size and type of super enameled copper conductor and number of turns to get the same rating and insulating material such as paper insulator sleeves, heating etc. Putting back the core and coil assemblies into the tank after removing sludge and replacement of HT & LT bushing complete with brass terminal, refixing top cover and conservator including replacement of gasket, nut, bolts & washers all to the complete satisfaction of Engineer - in - charge for the transformer of capacity up to 1250 KVA complete all as specified and as directed. NOTE - Cost of material and labour required for replacement of nuts, bolts, washers of suitable sizes, rubber gaskets of approved quality and size is deemed to be inclusive in the quoted rate.
M&L for installation and commissioning of transformer of capacity up to 1250 KVA in place of unserviceable transformer on hire basis for 10 days when ordered complete all as specified and as directed. NOTE :- Repairing of unserviceable transformer have to be completed within 10 days duration & no extra cost will be paid toward hiring charges beyond 10 days. Moreover contractor will not be allowed to shift the hired transformer until it is replaced by the repaired transformer and it shall be responsibility of the Contractor. Anything goes wrong in the hired transformer, no extra cost will be paid towards repairing of hired transformer and it shall be the responsibility of the Contractor. Contractor should check the available infrastructure and to be sure regarding safety of transformer before installation. The rate quoted is deemed to be inclusive of transportation cost, connecting incoming & outgoing cables, earthing leads, lifting/lowering arrangements, labour charges. Cost of materials and labours required for replacement of cable aluminium lugs as suitable for the existing sized cables, nuts, bolts and washers of suitable size is deemed to be inclusive in the quoted rates.
Supply only material for rewinding of HT coils with super enameled copper winding wire of appropriate gauge and proper number of turns to get the same capacity along with insulating materials e.g. leathered paper insulation, cotton tape, empire tape, wooden blocks, PVC sleeves, soldering job, varnishing and heating, drying etc. complete to the satisfaction of Engr- i n - Charge complete all as specified and as directed.
Supply only material for rewinding of LT coils with super enameled Class B copper strip with Electrical Grade Insulating Kraft paper all confirming to IEC-60554-3-5 (1984) and proper number of turns to get the same capacity along with insulating materials e.g. leathered paper insulation, cotton tape, empire tape, wooden blocks, PVC sleeves, soldering job, varnishing and heating, drying etc. complete to the satisfaction of Engr- i n - Charge complete all as specified and as directed.
M&L for replacing unserviceable drain valve 50mm size of various transformers after draining out transformer oil and refilling the oil into the transformer after filtration to get required dielectric strength 60 KV complete all as specified and as directed.
M&L anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately) complete all as specified and as directed.
S&F in repairs heavy duty station class, Gap less type Metal oxide lightning arrestors, 22 KV of 9KA rupturing capacity complete with all fittings distribution class suitable for 22KV earthed system discharge capacity 65 Kilo Amps complete all as specified and directed. Make:- BHEL/ ELPRO/ CG Note: Modifications to support structure as per OEM Requirements shall be the scope of Contractor. No Extra payment will be entertained on this account
S&F in repairs heavy duty station class, Gap less type Metal oxide lightning arrestors, 11 kV of 9kA rupturing capacity complete with all fittings distribution class suitable for 11KV earthed system discharge capacity 65 Kilo Amps complete all as specified and directed. Make:- BHEL/ ELPRO/ CG Note: Modifications to support structure as per OEM Requirements shall be the scope of Contractor. No Extra payment will be entertained on this account
Testing of transformers of various capacities installed at various locations under GE (C) Kirkee by performing following tests - 1.IR Value on L.V & H.V side using 500 V & 5KV Megger respectively, 2.Ratio on all the taps, 3.Magnetic Balance tests on L.V & H.V., 4.Vector group, 5. Magnetizing current, 6.Winding Resistance Test on H.V & LV terminals. Note : i) Contractor should make his own arrangement of testing equipments and electric supply so required. (ii) A detailed Test Report should be submitted to Engr-in-Charge.
M&L for earthing complete with pure copper solid bar 25 mm outer dia electrode, including testing, 3 mtr long and having suitable hole on top to connect earthing strip with nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 200 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with copper strip 25x3 mm with minimum two Nos of copper/ GM nut bolts and connected to test point from earthing pit. The earthing should be filled with carbon based earthing compound. The resistance of the compound should be less than 0.1 Ohms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between 7-9. Connected to the earthing test point, Fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning filling & removal of extra soil , to achieve earth resistance value less than 3 Ohms including testing complete all as specified and as directed. Make U-Protect or equivalent NOTE : - (i). Earthing strip GI/copper upto 7.5m will be measured and paid under this item only. (ii). Quoted rate is deemed to be inclusive of cost of demolition of old earthing as directed by Engr-in-Charge. (iii). The new earthing so constructed must have resisitance value below 3 ohms. If the aforesaid resistance value is not achieved contractor has to make proper aadditions/alterations to the newly constructed earthing at his own cost. (IV) The earthigs are to be done in arockey area.
M&L copper earth continuity conductor or main earthing lead of size 20x3mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and as directed.
S&F Buchholz Relay 25/50 mm size with round flange Four/six hole as per existing model EE2/EE3 type with wiring as per existing and oil flow as per existing rating, working at normal ambient temperature (0-50 C) suitable for 22KV/415V including nut bolt gasket & connecting and testing complete all as specified and as directed. Make :Cedaspe/Atvas Baif/ Yogya/Sukrut.
Star Electrical
PAMS ENTERPRISES
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .