Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.5 L+₹1.5 L (5.05%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹33.0 L+₹3.0 L (10.1%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹34.1 L+₹4.1 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
8 Apr 2023, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
SPECIAL REPAIRS TO BLDG NO 11C AND PROVN OF INCINERATOR FOR FEMT AND NEW HQ ADM BUILDING AT MCEME UNDER GE MCEME SECUNDERABAD
2023_MES_585387_1
GE/MCEME/TOK/57 OF 22-23
Open Tender
Civil Works
Item Rate
180 days
GE MCEME SECUNDERABAD
Class D category a(I)
9 documents required · 9 mandatory
₹500
GE MCEME SECUNDERABAD
₹73,000
Yes
21 Apr 2023
11 Mar 2023
10 Apr 2023
11 Mar 2023
8 Apr 2023
27 Mar 2023
Amount
Dismantling of asbestos cement (corrugated,semi corrugated etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws' complete all as specified and directed by Engineer-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position unframed work, complete all as specified and directed by Engineer-in-Charge.
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates, Fe410-W (Gde-E-250) quality-A, complete all as specified and directed by Engineer-in-Charge.
S& F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, etc complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed by Engineer-in-Charge.
M&L preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote, etc complete all as specified and directed by Engineer-in-Charge.
S&F for Polycarbonate transperant corrugated sheeting 3 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and directed by Engineer-in-Charge.
S&F prepainted steel windows/ventilators ( ECO–4000 Series Windows (Double Rebate Windows) or equivalent) fabricated from roll framed sections made of galvanized steel colour coated/powder coated (Base steel as per IS-513 “D” quality galvanized as per IS-277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm. Sections for Frame should be of 72x55mm, Section for Mullion should be of 72x50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12x12mm, and Section for Fly Mesh should be of 40x20mm Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter including SS Pivot Hinges–1 set, Seccolor Handle & Seccolor Stay and 4mm Plain Float Glass and Stainless Steel 32 gauge Fly mesh of 25 holes per SqCM and powder coated Grill made of 10mm sq. MS Bars welded at 150mm c/c, 6x12mm MS flat and fixed to window frame with screws , complete all as specified and directed by Engineer-in-Charge. (Make : NCL/TATA/Equivalent)
Taking down,Chowkhats or frames exc. 1.5 sq. m and n.exc. 4 Sqm each, but with shutters (without taking off shutters from the frames), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames not exc 1.5 sqm each(without taking off shutters from the frames), etc complete all as specificed and as per directed by Engineer-in-Charge.
S/F pressed steel door frame 125 x 60mm with one or more rebats including fixing lugs, hinges, lock strike plate etc complete all as specified and directed
S/F pressed steel door frame 105 x 60mm with one or more rebats including fixing lugs, hinges, lock strike plate, complete all as specified and directed by Engineer-in-Charge.
S & F 2nd class hardwood,Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints,etc complete all as specified and directed by Engineer-in-Charge.
S & F 35 mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on face is covered with decorative face veneer both sides , complete all as specified and directed by Engineer-in-Charge.
S&F of 35mm thick Second class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc. divided in to square with plain chamfered or rounded mitred and rebated sash bars, any numbers, edges of framing plain chamfered or , complete all as specified and directed by Engineer-in-Charge.
S&F 2nd class hard wood 35mm thick, plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, the sizes of members of shutters shall be, etc complete all as specificed and as per directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated surface of wood or wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enemal paint over a coat of pink primer, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F 100 mm long butt hinges extruded aluminium alloy with brass/bronze hinge pin in lieu of mild steel min , complete all as specified and directed by Engineer-in-Charge.
S/F 150mm size aluminium anodised handles, fabricated type , complete all as specified and directed by Engineer-in-Charge.
S/F 150mm long aluminium anodised barrel tower bolt of extruded section , complete all as specified and directed by Engineer-in-Charge.
S & F for Floor door stopper of brass body and tongue, anodised,with hard drawn steel spring, fixed in floor, Overall length of cover plate 140 mm,etc complete all as spd and directed.
S&F 300mm long MS ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed by Engineer-in-Charge.
Dismantling boarding, any description fixed in any position with nails, complete all as specified and directed by Engineer-in-Charge.
M & L for 18 mm thick, Plywood, grade BWR, type BB, fixed with screws to timber frame work in repairs, complete all as specified and directed by Engineer-in-Charge.
M & L for 0.9 mm thick, Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
S & F for Butt hinges 75mm in size, medium weight, cold rolled mild steel, and fixed, size of hinges in 25 mm, complete all as specified and directed by Engineer-in-Charge.
S & F for Brass handles, cast type, polished bright, Size of handle in 100 mm,complete all as specified and directed by Engineer-in-Charge.
S&F 50 mm long Magnet ball catcher made out of PVC fixed to shutter and chowkhats with SS screw all as specified and directed by Engr-in-Charge.
S&F 100 mm size Hasp and staple, Aluminium anodised, wire type, including bolt to hinge plate and fixed with screws complete all as specified and as directed.
M & L Granite (of any type) work (table rubbed and polished) 18-20 mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc , etc complete all as specified and as per directed by Engineer-in-Charge.
Rounding off edges of granite platform/urinal partition, etc complete all as specified and as per directed by Engineer-in-Charge.
M&L for dismantling stone slabs and tiles laid dry and pointed of any description or thickness in floors, aprons etc.complete all as specified and directed by Engineer-in-Charge.
M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick screed bed or bedding layer of cement mortar 1:6 laying floor finishes complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc and jointed in neat cement slurry 15mm thick screed bed or bedding layer of cement mortar 1:6 laying floor finishes and pointed in white or coloured cement to match , etc complete all as specificed and as per directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles 450x300x7mm thick, vertical surfaces such as dados, incl 10mm thick rendering in CM 1:3 to receive tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match, etc complete all as specificed and as per directed by Engineer-in-Charge.
M & L 75mm thick PCC 1:3:6 type C-2 using 40mm graded aggregate as in plinth protection, complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, TMT bars,etc, complete all as specified and directed by Engineer-in-Charge.
S & F for Collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, etc complete all as spd and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge.
M&L brick work with sub class 'B' bricks old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Taking down of cement plaster on brick or stone walls,/ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick cement plaster in two layers (5mm thick in CM 1:4 with using water proofing compound over 10mm thick in CM 1:6) on external surfaces of brick work or concrete surfaces even and smooth without using extra cement, complete all as specified and as per directed by Engineer-in-Charge.
Supply only Integral water proofing compound, etc complete all as specificed and as per directed by Engineer-in-Charge.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-in-Charge.
M&L Rough cast plaster as specified ,etc complete all as specified and directed by Engineer-in-Charge.
Demolition of Lime concrete / Mud phuska / PCC of any description and in any position not otherwise specifically provided for renewal including removal of demolished material beyond the Md land to a distance exceeding 500mtr not exceeding 1.5KM completed all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in floor / roof padding, complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 10mm thick in cm (1:3) on concrete surfaces of roof padding with integral water proofing compound (water proofing compound to be paid separately ) finished even & smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L APP based polymeric membrane minimum weighting 3 kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gm/Sqm) laid on primed surface by forced application over a coat of a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces, complete all as specified and directed by Engineer-in-Charge.
S&F 1000 Ltr capacity of rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) three layered hoisted and fixed in position including dismantling all as specified in SSR Part-I), etc complete all as specified and as per directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 15 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 20 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 25 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F steel water tubing medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe 15 mm, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F steel water tubing medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe 20mm, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F steel water tubing medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe 25mm, etc complete all as specificed and as per directed by Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required of brick walls and pointed in cement mortar 1:3 for concealed water tubing etc cutting not exc 10 cm girth, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in repairs chromium plated fancy type stop cock copper alloy 15mm bore screwed down high presure with crutch or butterfly handle screwed both ends for iron pipes, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in rep CP bib taps cast copper alloy with crutch or butterfly handle, screwed for iron pipe of dia 15mm, fancy type, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in repairs Gun metal globe or gate valve 20mm bore dia of pipes, with iron wheel head screwed both ends for iron pipe and fixed, etc complete all as specified and as per directed by Engineer-in-Charge.
S&F in repairs 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete, screwed for iron pipe or for brass ferrule of 20mm dia, etc complete all as specified and as per directed by Engineer-in-Charge.
S&F PVC (SWR) 100/110mm bore single socketed pipes in any length with rubber ring joints fixed to wall with pvc clamps including taking down old pipes, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F PVC (SWR) bend/shoe for 100/110mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) gully grap 125/110mm setting and jointing with solvent cement and preparation of trap hole, etc complete all as specificed and as per directed by Engineer-in-Charge.
Excavation in trenches n.exc 1.50m wide and n.exc. 1.50m depth and getting out in hard/dense soil , complete all as specified & directed by Engr-in-Charge.
Excavation in trenches exc 1.50m wide and n.exc. 3.00m depth and getting out in hard/dense soil, complete all as specified & directed by Engr-in-Charge.
Returning, filling in incl spreading, leveling, watering and well ramming in layers n. exc 25cm all as specified.as in soft /loose soil, complete all as specified & directed by Engr-in-Charge.
Removing excavated materials n'exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point in soils, complete all as specified & directed by Engr-in-Charge.
M&L salt glazed stone ware drain pipes 100mm dia bore (Grade 'A' pipe) laid in trenches and jointed as specified incl demolition and breaking up, complete all as specified & directed by Engr-in-Charge.
M&L salt glazed stone ware drain pipes 150mm dia bore (Grade 'A' pipe) laid in trenches and jointed as specified incl demolition and breaking up, complete all as specified & directed by Engr-in-Charge.
M&L Reinforced concrete pipes 150mm dia bore, class NP3, laid and jointed complete with collars laid in trenches and jointed as specified incl demolition and breaking up, complete all as specified & directed by Engr-in-Charge.
M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 100mm dia SWG pipe, complete all as specified & directed by Engr-in-Charge.
M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150mm dia SWG pipe, complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:4:8, type D2 (using 40mm graded stone aggregated) as in foundations, filling and mass concrete, complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregated) set in CM 1:4 as in benching to manholes/drain surface, complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregated) as in coping incl necessary form work, complete all as specified & directed by Engr-in-Charge.
Demolition of cement concrete of any description in any position (Reinforced), complete all as specified & directed by Engr-in-Charge.
S&F TMT bars 6mm dia and over upto and incl 8mm dia as in reinforced, incl binding with and incl MS wire (annealed) not less than 0.9mm dia , complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregate as in pre-cast cover slabs for manholes incl necessary form work set in CM 1:4, complete all as specified & directed by Engr-in-Charge.. (Reinforcement will be measured & paid separately)
M&L 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces of walls finished the surface even & smooth without using extra cement, complete all as specified & directed by Engr-in-Charge.
M&L for Two coats of Distempering with oil emulsion distemper on newly plastered surfaces of walls over two coat of wall care putty over a coat of alkali resistance primer including preparation of wall surfaces, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation newly plastered surfaces of wall and cornices and applying two coats of acrylic weather proof painting over one coat of primer on wall over two coat of wall care putty to make surfaces smooth and good, complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old decorated wall surface and applying two coats of OBD over two coat of wall care putty, complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatement including preparation of old decorated surfaces of wall and cornices and applying two coats of acrylic weather proof painting on wall to make surfaces smooth and good, complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base etc., complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushion/bed for laying interlocking tiles / paver blocks, complete all as specified and directed by Engineer-in-Charge.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with gery cement and no pigment, , complete all as specified and directed by Engineer-in-Charge.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n. exc 30cm high with synthetic enamel paint of painted wall surfaces, complete all as specified and directed by Engr-in-Charge. (Note : Work to be carried out from ground floor to fourth floor of bldg height)
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/ dense soil, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base etc., complete all as specified and directed by Engineer-in-Charge.
M & L for firebrick work in linings to fire places, flues, etc. (other than in chimney shafts), set, jointed and pointed in fireclay etc complete all as spd and directed.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:3) finished even & smooth (without using extra lime or cement ) complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) finished even & smooth (without using extra lime or cement) complete all as specified and directed by Engineer-in-Charge.
M&L RCC type B1 (1:2:4) using 20mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
S& F Framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel'), etc complete all as spd and directed.
S & F 1.00 mm thick Plain, galvanised, mild steel sheeting, in valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of cement base paint over a coat of primer including preparation of newly plastered surface on walls complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C2 (using 40mm graded agg) as in foundation filling and mass concrete etc complete all as spd and directed complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface with broken stone or boulders complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes, complete all as specified and as directed by Engr-in-Charge.
M & L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments, complete all as specified and as directed by Engr-in-Charge.
Formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat complete all as specified and directed by Engineer-in-Charge.
M&L Mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending spirally including mild steel wire not less than 0.9 mm dia or securing with clips.
M&L mild steel TMT bars 8mm dia and over cut to length bent to shape required including cranking, bending spirally including mild steel wire not less than 0.9mm dia or securing with clips for stirrups
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit wiring including Tee, Junction boxes and provision of modular terminal boxes and covered with modular cover plate with frame of suitable size including suitable screws with washer for mounting modular switch, modular sockets and modular regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way Modular switch 5 amps, SP complete all as specified and directed by Engineer-in-Charge.
All as per item No. 113 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and directed by Engineer-in-Charge.
All as per item No. 113 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge.
All as per item No. 113 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed by Engineer-in-Charge.
All as per item No. 113 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Modular Switch , 1 module, 6 Amps capacity 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Modular Switch , 1 module, 16 Amps capacity 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Modular socket outlet 6 Amps 2 /3 pin 2 module complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Modular socket outlet 6/16 Amps 2 /3 pin 2 module complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including two run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Four runs of cable, two run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From Panel board to TPN DB)
Material and labour for concealed Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including two run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Four runs of cable, two run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From TPN DB to 3 Ph ind sockets)
Material and labour for concealed Submain wiring with 2 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From TPN DB to SPN DB)
Material and labour for concealed Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From DB to 1 ph Ind sockets)
S & in replace of Vertical type MCCB TPN DB 4 way double door suitable for MCCB 100 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed.
Supply and replace MCCB 4P, 415V,16KA, 100 amps suitable for Vertical MCCB DB complete all as specified and directed by Engineer-in-Charge.
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface.
Supply and fix in repair MCB SPN 40 Amps 240 volts for fixing on MCB DB complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair MCB TP 40 Amps 240 volts for fixing on MCB DB complete all as specified and directed by Engineer-in-Charge.
Suppy and fix in repair single phase 240 V sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and directed by Engineer-in-Charge.
Suppy and fix in repair three phase 415V sheet metal enclosure with a three pin and earth plug and socket complete with one three pole MCB 32A complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED wall mounted batten light fitting with polycarbonate housing and integrated electronic driver 1x 20W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fix LED energy efficient security light fitting of capacity of 40 W including suitable dia GI pipe bracket for fixing the light on wall all as specified and directed. NOTE : GI bracket, clamp, nut and bolt etc will be measured in separate item.
Supply and fixing galvanised iron tube bracket of 40 mm dia light grade and 1.2 m length for fixing bldg security light, with all fixing arrangement including necessary clamp, nut and bolts etc as required size all as specified and directed
S & F Exhaust fan metal body , 450 mm sweep , single phase ,50 HZ , with louver and connecting up with and incluiding provision of PVC insulated copper flexible cord of size 23/0.019, 3 core from ceiling rose to connection of exhaust fan and including material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge. Note : cost for material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface will be measured and paid in seperate item.
M&L for making hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface including cement work and painting to the wall matching to the existing complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.) complete all as specified and directed by Engineer-in-Charge.
K LAKSHMAN SINGH AND CO
SAI RUPA CONSTRUCTIONS
RAM CHARAN CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .