| 1 | L1₹9.9 CrAccepted-AOC M 11 22 BADLI IND ESTATE DELHI 110042 | DELHI | NORTH DELHI | DELHI | 110042 | ₹9.9 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹11.4 Cr+₹1.5 Cr (14.9%)Rejected-AOC 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹11.4 Cr+₹1.5 Cr (14.9%) | L2 | Rejected-AOC NOT BEING L1 |
| 3 | L3₹11.8 Cr+₹1.9 Cr (19.2%)Rejected-AOC PLOT NO 13 THIRD FLOOR BANSAL PLAZA SECTOR 6 COMMERCIAL COMPLEX DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹11.8 Cr+₹1.9 Cr (19.2%) | L3 | Rejected-AOC NOT BEING L1 |
| 4 | L4₹13.7 Cr+₹3.8 Cr (38.5%)Rejected-AOC 113 1B KUNDALAHALLI BESIDE BROOKE BENGALURU KARNATAKA 560037 | BENGALURU URBAN | KARNATAKA | 560037 | ₹13.7 Cr+₹3.8 Cr (38.5%) | L4 | Rejected-AOC NOT BEING L1 |
| 5 | L5₹16.1 Cr+₹6.2 Cr (62.8%)Rejected-AOC | ₹16.1 Cr+₹6.2 Cr (62.8%) | L5 | Rejected-AOC NOT BEING L1 |
| Sl No | Description | Qty | Unit | M K ENGINEERS CO. L2 | SRIT INDIA PRIVATE LIMITED L4 | MD TRANSCON PRIVATE LIMITED L5 | Allied Engineering Works Limited L1 | M/S RADIUS SYNERGIES INTERNATIONAL PVT LTD L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Schedule 'A' Part - I
Supply, design, installation, testing and commissioning integrate and maintaining of the advanced metering infrastructure(AMI) comprising of following:-
(a) Supply, installation, testing and commissioning of smart meter AC single phase two wire, 240 volts, 50 Hz 10 to 60 Amps of different makes (not more than 33% of a particular make to ensure interchangeability at a later date) as per BIS 16444 2015 (Reaffirmed 2020) with communication technology including GPRS/RF/Hybrid (RF+GPRS)/ any other advanced technology as per CEA/TRAI regulations, prepayment / post payment features.
(b) Supply, planning, setup, tuning of RF communication infrastructure including Network Management System (NMS) & Head End System (HES) for the project area. AMI software and associated equipments should be capable of handling at least 20000 numbers of meters of different makes as per BIS 16444 2015 (Reaffirmed 2020) with 25% expansion without any additional infrastructure and cost implication to MES.
(c) Supply and set up of Meter Data Management (MDM) system.
(d) Integration of different devices of different makes/ equipment/ software covered in scope of this project with each other as per functional requirements including water charges, furniture and license fee. | 9,777 | Each Job | 6,339 ₹6,19,76,403 | 4,650 ₹4,54,63,050 Lowest | 6,775.02 ₹6,62,39,370.54 | 5,000 ₹4,88,85,000 | 4,835.05 ₹4,72,72,283.85 |
| 1.01(e) Integration/interface of the AMI system with application system like metering/billing/collection interface has to be provided in the proposed solutions to upload and process meter data from these system. (f) Server for housing and management of supplied software application with stand by server or Hosting the system to government cloud in place of server for hosting and management of supplied software application with standby server. (g) Planning, deployment and tuning of communication system including cellular network (if required) to meet the performance requirements. (h) Business intelligence, Analytics and Reporting. (j) Taking down and return of dismantled materials i.e old electric meters & connecte items.Contractor will submit last meter reading alongwith qtr/ accn No, with meter SI No before dismantling of old meters to deposit in MES stores. (k) Training and knowledge transfer/Training to the user and MES personnel for operating, acquiring data etc and administrative training to selective persons for running system. (l) All expenditure including periodic charges of telecom operator from installation till completion. (m) Supply, install and commissioning of any software updates, upgrades and patches released after support period till completion of contract under scope of agreement during defect liability period. (n) Any sundry items like connecting wires,nuts,bolts,washers,screws etc are to be required to fix the meter are deemed to be included in the quoted rate. | ||||||||
| 1.02(o) The entire infrastructure and associated Civil/Electrical works required for installation and commissioning of field equipments/ devices such as DCUs, Repeaters, Routers and access points etc. Note :- 1. The defect liability period will be 2 years from the date of completion. 2. Housing of server and standby server as per tender document to be installed at HQ Training Command and all as per direction of nodal officer in consultation with user. 3. The new smart meter should be installed as under : (i) Single Phase - JCO/OR/Civilian Type I, II, III & single Offr Accn (ii) Three Phase - Md Offr Accn/ Civ Type IV & above | ||||||||
| 2.00 | All as specified in item no - 1 above but three phase four wire, 415 volts, 50 Hz and of 10 to 60 Amps rating. | 646 | Each Job | 9,000 ₹58,14,000 | 5,600 ₹36,17,600 Lowest | 8,287.05 ₹53,53,434.3 | 7,500 ₹48,45,000 | 6,717.15 ₹43,39,278.9 |
| 3.00 | Supply and install print, copy, scan, capacitive touch wireless report printer with 12 pages per minute capacity, 600 x 600 dpi with HP, RET, 1200 dpi effective output quality 600 x 600 x2 dpi with RET, with duty cycle 3000 single sided pages per month complete all as specified and as directed. | 9 | Each | 43,000 ₹3,87,000 | 1,30,000 ₹11,70,000 | 29,133.6 ₹2,62,202.4 | 27,000 ₹2,43,000 | 19,470 ₹1,75,230 Lowest |
| 4.00 | Supply and fix desktop with processor not less than i7, 9th generation, 8GB RAM, hard disk/SSD 1TB, 4-USB port including 18.5" monitor of same make, keyboard, mouse, anti virus 5 year warranty software along with 650VA capacity UPS and provn of licensed operating system (Window 10/Latest) complete all as specified and as directed. | 7 | Each | 1,31,000 ₹9,17,000 | 1,00,000 ₹7,00,000 Lowest | 1,15,077.72 ₹8,05,544.04 | 1,00,000 ₹7,00,000 Lowest | 1,36,290 ₹9,54,030 |
| 5.00 | Material and labour for sub main wiring with two single core 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC conduit not less than 25 mm dia ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiring complete all as specified & directed by Engineer-in-Charge.
Note:- Two runs of 6 sqmm single core multistranded cable and one run 6sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | 26,390 | Running Metre | 400 ₹1,05,56,000 | 350 ₹92,36,500 | 655.51 ₹1,72,98,908.9 | 250 ₹65,97,500 Lowest | 508.81 ₹1,34,27,495.9 |
| 6.00 | Material and labour for sub main wiring with four single core 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Conduit not less than 25 mm dia ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiringcomplete all as specified & directed by Engineer-in-Charge.
Note:- Four runs of 10 sqmm single core multistranded cable and one run 10sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | 3,315 | Running Metre | 1,000 ₹33,15,000 | 520 ₹17,23,800 Lowest | 1,966.52 ₹65,19,013.8 | 550 ₹18,23,250 | 1,339.53 ₹44,40,541.95 |
| 7.00 | Material and labour for sub main wiring with four single core 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Conduit not less than 25 mm dia ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiringcomplete all as specified and as directed.
Note:- Four runs of 6 sqmm single core multistranded cable and one run 6sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | 500 | Running Metre | 600 ₹3,00,000 | 500 ₹2,50,000 | 1,092.51 ₹5,46,255 | 350 ₹1,75,000 Lowest | 800.86 ₹4,00,430 |
| 8.00 | Material and labour for sub main wiring with two single core 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Conduit not less than 25 mm dia, ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiring complete all as specified & directed by Engineer-in-Charge.
Note:- Two runs of 10 sqmm single core multistranded cable and one run 10 sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | 55 | Running Metre | 611 ₹33,605 | 4,828 ₹2,65,540 | 1,179.91 ₹64,895.05 | 450 ₹24,750 Lowest | 867.06 ₹47,688.3 |
Tender Value
₹13.2 Cr
EMD Value
₹9.9 L
Closing Date
8 Jan 2026, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF SMART METER AND ASSOCIATED INFRASTRUCTURE FOR TC AOR OF HQTC (U) AND CERTAIN LOCATIONS UNDER GE (AF) MARATHAHALLI BANGALORE
2025_MES_744130_1
801683/AF/E8
Open Tender
Civil Works
Item Rate
4252 days
GE(AF)BANGALORE
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE(AF)BANGALORE
₹9.9 L
Yes
7 Apr 2026
11 Dec 2025
15 Jan 2026
11 Dec 2025
8 Jan 2026
1 Jan 2026
12 Dec 2025 - 22 Dec 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Schedule 'A' Part - I Supply, design, installation, testing and commissioning integrate and maintaining of the advanced metering infrastructure(AMI) comprising of following:- (a) Supply, installation, testing and commissioning of smart meter AC single phase two wire, 240 volts, 50 Hz 10 to 60 Amps of different makes (not more than 33% of a particular make to ensure interchangeability at a later date) as per BIS 16444 2015 (Reaffirmed 2020) with communication technology including GPRS/RF/Hybrid (RF+GPRS)/ any other advanced technology as per CEA/TRAI regulations, prepayment / post payment features. (b) Supply, planning, setup, tuning of RF communication infrastructure including Network Management System (NMS) & Head End System (HES) for the project area. AMI software and associated equipments should be capable of handling at least 20000 numbers of meters of different makes as per BIS 16444 2015 (Reaffirmed 2020) with 25% expansion without any additional infrastructure and cost implication to MES. (c) Supply and set up of Meter Data Management (MDM) system. (d) Integration of different devices of different makes/ equipment/ software covered in scope of this project with each other as per functional requirements including water charges, furniture and license fee. | |||||
| 1.01 | (e) Integration/interface of the AMI system with application system like metering/billing/collection interface has to be provided in the proposed solutions to upload and process meter data from these system.
(f) Server for housing and management of supplied software application with stand by server or Hosting the system to government cloud in place of server for hosting and management of supplied software application with standby server.
(g) Planning, deployment and tuning of communication system including cellular network (if required) to meet the performance requirements.
(h) Business intelligence, Analytics and Reporting.
(j) Taking down and return of dismantled materials i.e old electric meters & connecte items.Contractor will submit last meter reading alongwith qtr/ accn No, with meter SI No before dismantling of old meters to deposit in MES stores.
(k) Training and knowledge transfer/Training to the user and MES personnel for operating, acquiring data etc and administrative training to selective persons for running system.
(l) All expenditure including periodic charges of telecom operator from installation till completion.
(m) Supply, install and commissioning of any software updates, upgrades and patches released after support period till completion of contract under scope of agreement during defect liability period.
(n) Any sundry items like connecting wires,nuts,bolts,washers,screws etc are to be required to fix the meter are deemed to be included in the quoted rate. | - | - | - | - |
| 1.02 | (o) The entire infrastructure and associated Civil/Electrical works required for installation and commissioning of field equipments/ devices such as DCUs, Repeaters, Routers and access points etc.
Note :- 1. The defect liability period will be 2 years from the date of completion.
2. Housing of server and standby server as per tender document to be installed at HQ Training Command and all as per direction of nodal officer in consultation with user.
3. The new smart meter should be installed as under :
(i) Single Phase - JCO/OR/Civilian Type I, II, III & single Offr Accn
(ii) Three Phase - Md Offr Accn/ Civ Type IV & above | - | - | - | - |
| 2All as specified in item no - 1 above but three phase four wire, 415 volts, 50 Hz and of 10 to 60 Amps rating. | |||||
| 3Supply and install print, copy, scan, capacitive touch wireless report printer with 12 pages per minute capacity, 600 x 600 dpi with HP, RET, 1200 dpi effective output quality 600 x 600 x2 dpi with RET, with duty cycle 3000 single sided pages per month complete all as specified and as directed. | |||||
| 4Supply and fix desktop with processor not less than i7, 9th generation, 8GB RAM, hard disk/SSD 1TB, 4-USB port including 18.5" monitor of same make, keyboard, mouse, anti virus 5 year warranty software along with 650VA capacity UPS and provn of licensed operating system (Window 10/Latest) complete all as specified and as directed. | |||||
| 5Material and labour for sub main wiring with two single core 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC conduit not less than 25 mm dia ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiring complete all as specified & directed by Engineer-in-Charge. Note:- Two runs of 6 sqmm single core multistranded cable and one run 6sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | |||||
| 6Material and labour for sub main wiring with four single core 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Conduit not less than 25 mm dia ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiringcomplete all as specified & directed by Engineer-in-Charge. Note:- Four runs of 10 sqmm single core multistranded cable and one run 10sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | |||||
| 7 | Material and labour for sub main wiring with four single core 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Conduit not less than 25 mm dia ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiringcomplete all as specified and as directed.
Note:- Four runs of 6 sqmm single core multistranded cable and one run 6sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | 500 | Running Metre | - | - |
| 8 | Material and labour for sub main wiring with two single core 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Conduit not less than 25 mm dia, ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc, screws, gutti / ravel plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 10 sqmm PVC insulated, unsheathed, FRLSH multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, yellow, & blue, Neutral-Black, and Earth-Green including taking down of old sub main wiring complete all as specified & directed by Engineer-in-Charge.
Note:- Two runs of 10 sqmm single core multistranded cable and one run 10 sqmm multistranded cable as earth wire including PVC conduit together will be measured as one unit. | 55 | Running Metre | - | - |
stage.html
html • 0.06 MB
techsummary_833232.pdf
finance_833232.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_833232.xls
BOQ • 0.30 MB
801683Tender.pdf
Tender Documents • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .