Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: microtek
Model: Microtek UPS Twin Guard Pro+ 1000VA 1 B VASHISHT NAGER BABYAL ROAD NEAR HARYANA GRAMIN BANK AMBALA CANTT AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: microtek
Model: Microtek UPS Twin Guard Pro+ 1000VA | ₹1.4 L | L1 | Qualified |
| 2 | L2₹1.5 L+₹8,225 (5.75%)Qualified Make: microtek
Model: Microtek UPS Twin Guard Pro+ 1000VA CHANDRASEKHARPUR BHUBANESWAR ODISHA 751016 INDIA | KHORDHA | ODISHA | 751016 | Make: microtek
Model: Microtek UPS Twin Guard Pro+ 1000VA | ₹1.5 L+₹8,225 (5.75%) | L2 | Qualified |
| 3 | L3₹1.5 L+₹10,850 (7.59%)Qualified Make: LUMINOUS
Model: 1000VA LUMINOUS UPS UNO 1KVA A 103 BHARAT NAGAR NEW FRIENDS COLONY NEW DELHI SOUTH DELHI DELHI 110025 | SOUTH EAST DELHI | DELHI | 110025 | Make: LUMINOUS
Model: 1000VA LUMINOUS UPS UNO 1KVA | ₹1.5 L+₹10,850 (7.59%) | L3 | Qualified |
| 4 | L4₹1.6 L+₹14,490 (10.1%)Qualified Make: MICRO POWER
Model: MICRO POWER MPT1000L KALI MANDIR ROAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Make: MICRO POWER
Model: MICRO POWER MPT1000L | ₹1.6 L+₹14,490 (10.1%) | L4 | Qualified |
| 5 | Disqualified Make: zebronic
Model: zebronic) (Zebronics UPS ZEB-U1200) 2 SHAH MARKET KATPIECE GALI BOMBAY BAZAR KHANDWA MADHYA PRADESH 450001 | EAST NIMAR | MADHYA PRADESH | 450001 | Make: zebronic
Model: zebronic) (Zebronics UPS ZEB-U1200) | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
19 Jul 2018, 8:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 35 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 1.0/800 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for printer (not through inverter) Yes Yes 1/4 Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - 2/4 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date NTS/OFFLINE UPS/06/DT-29.6.2017 - Name Of Lab NISAKI TECHNOLOGY SUPERVISES - Address of Lab BANGLORE - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dhanesh E P 761052
ARMY AIR DEFENCE RECORDS
GOPALPUR MILITARY STATION
GANJAM
ODISHA-761052 35 25
321311
GEM/2018/B/45568
Line Intractive UPS with AVR
25 days
Odisha; Ganjam
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 35 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 1.0/800 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for printer (not through inverter) Yes Yes 1/4 Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - 2/4 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date NTS/OFFLINE UPS/06/DT-29.6.2017 - Name Of Lab NISAKI TECHNOLOGY SUPERVISES - Address of Lab BANGLORE - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dhanesh E P 761052 | - | - | - |
| ARMY AIR DEFENCE RECORDS | - | - | - |
| GOPALPUR MILITARY STATION | - | - | - |
| GANJAM | - | - | - |
| ODISHA-761052 35 25 | - | - | - |
Exempted
19 Jul 2018
11 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_321311.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .