Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.0 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹42.8 L+₹4.1 L (10.6%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | 2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | 3₹44.6 L+₹5.9 L (15.3%)Rejected-AOC | 3 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 4 | 4₹45.6 L+₹6.9 L (17.9%)Rejected-AOC KARNATAKA | RAICHUR | KARNATAKA | 584123 | 4 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 5 | 5₹48.9 L+₹10.3 L (26.6%)Rejected-AOC | 5 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Jul 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
Cleaning and painting of OH tank, repair of valve, pit chamber, sign board and connected items under GE Satwari
2020_MES_347458_1
GEJM-49/20-21
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
GE SATWARI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SATWARI
₹96,000
Yes
7 Aug 2020
15 Jun 2020
15 Jul 2020
15 Jun 2020
13 Jul 2020
29 Jun 2020
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of pipes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft loose soil all as specified and directed.
Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified.
Removing excavated surplus materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
Note for item No 1 to 3 :- During the excavation any damage to the existing services like telephone cable,electric cable, sewage line etc will be repaired by the contractor at his own risk & cost. No extra payment will be born by the dept. on this account.
Material and labour for removal of deposited scales from inside the Over head reservoir of capacity 2.0 lakhs gallons with the help of wire brush and pressure pump of pressure not less than 50 to 80 bar, from the overhead tank and white washing the inner surface of the tank all as directed by Engr-in Charge
Description all as per Srl No 5 but of size 1.0 Lakhs gallons
Description all as per Srl No 5 but of size 0.7 Lakhs gallons
Description all as per Srl No 5 but of size 0.5 Lakhs gallons
Description all as per Srl No 5 but of size 0.25 Lakhs gallons
Material and labour for scrubbing the walls of over head reservoir from outer surface with iron brushes and cleaning the wall of 2.0 Lakh gallons cap all as directed and removing the dust/soil material and preparing the surfaces for colour washing and applying two coats of cement based paint on the outer surface of the tank and staging with providing two coats of enamelled paint on the CI/ MS pipes and rails and grills all as specified and directed. Engr-in Charge
Description all as per Srl No 10 but of size 1.0 Lakhs gallons
Description all as per Srl No 10 but of size 0.7 Lakhs gallons
Description all as per Srl No 10 but of size 0.5 Lakhs gallons
Description all as per Srl No 10 but of size 0.25 Lakhs gallons
Material and labour for removal of deposited scales from inside the under ground sump of capacity 1.0 lakhs gallons with the help of wire brush and pressure pump of pressure not less than 50 to 80 bar, from the UG Sump and white washing the inner surface of the sump all as directed by Engr-in Charge
Description all as per Srl No 15 but of size 0.5 Lakhs gallons
Material and labour for scrubbing the walls of under ground sump from outer surface with iron brushes and cleaning the wall of 1.0 Lakh gallons cap all as directed and removing the dust/soil material and preparing the surfaces for colour washing and applying two coats of cement based paint on the outer surface of the sump with providing two coats of enamelled paint on the CI/ MS pipes and rails and grills all as specified and directed. Engr-in Charge
All as per Srl No 17 but of size 0.5 Lakhs gallons
Material and labour for painting and writing letters "SAVE WATER" in Black letter size 36"X18" on dome of over head water RCC tank and UG Sump , writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white enamel paint over black background of any capacity over head tank and UG Sump all as directed Engr-in-charge
Testing of water by the approved govt lab authority’ and test the following perameter of water :- PH range, Total solids, total hardness, Floride, Nitrites, Nitrates, Lead Arsenic, Ammonia, Chlorides, Cadmium, Cyanide, Mercury Iron, Management, Surphate, Phernolic and submission the report to Deptt or as directed by Engr-in-charge Note :- water collected on present of medical staff / MES staff and empty collection sample bottle will be provide by the contractor
Dismentaling/broken of brick masonary valve pit of any size ,complete all as specified and directed.
Material and labour for construction of brick masonary valve pit built in cement mortar 1:6 of size 120cm x 120cm x110cm (internal dimension) over 15cm thick PCC 1:3:6 type C-2 sub base extended alround 15cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and plus pointing to brick wall surfaces externally as work proceeds complete with MS sheet cover 3.15 mm thick with handle and locking arrangement, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fashioners length not less than 15cm - 04 Nos) and painting with a coat of synthatic enamel paint over a coat of red oxide, complete all as specified and directed.
Description all as per Srl item No 22 here in before but of size 100cm x 100cm x 100cm (internal dimension).
Supply and fixng in replacement Cast iron Non return valve (NRV) 150 mm bore complete conforming to IS 1969 double flanged and drilled including bolts, nuts, washers, gasket etc complete and dismantling of old one complete all as specified and directed. make : KIRLOSKAR, LEADER, ZOLOTO, L&T (AUDCO)
Supply and fixng in replacement Cast iron Non return valve (NRV) 100 mm bore complete conforming to IS 1969 double flanged and drilled including bolts, nuts, washers, gasket etc complete and dismantling of old one complete all as specified and directed. make : KIRLOSKAR, LEADER, ZOLOTO, L&T (AUDCO)
Supply and fixing in replacement cast iron body sluice valve heavy duty class PN 1.6 flanged ends any pattern with cast iron wheel & mild steel spindle ISI marked confirming to IS-14846 of 2000 for 80mm bore pipe with jointing material ,flanged joint,rubber gasket 6mm thick, nuts & bolts, washer complete all as specified and directed. Make:- KIRLOSKAR, LEADER, ZOLOTO, L&T (AUDCO)
Description all as per Srl item No 26 here in before but 100mm bore pipe
Description all as per Srl item No 26 here in before but 150mm bore pipe
Description all as per Srl item No 26 here in before but 200 mm bore pipe
Burning out old leaking lead joints in position and removing old lead from 80mm bore CI pipe/ fittings and keeping aside for further disposal (earth work shall be measured and paid separately).
Description all as per Srl item No 31 here in before but for 100mm bore pipe.
Description all as per Srl item No 31 here in before but for 150mm bore pipe.
Description all as per Srl item No 31 here in before but for 200 mm bore pipe.
Material and labour for run lead joint including all jointing material such as lead, spun yarn etc for 80mm bore cast iron spigot & socketed pipe & fittings. (Exc earth work will be measured & paid for separately.
All as per item No 34 here in before but for 100mm bore cast iron spigot & socketed pipe & fittings.
All as per item No 34 here in before but for 150mm bore cast iron spigot & socketed pipe & fittings.
Description all as per Srl item No 34 here in before but for 200 mm bore pipe.
M & L for welding the existing leakage GI Pipe line any size by using electric welding machine & welding electrode . Note :Earth work shall be measured and paid separately under respective item of shedule
Supply and fixing self closing PVC bib taps 15 mm dia screwed with existing GI pipe complete ISI marked all as specified and directed.
Supply and fixing in replacement Ball valve, screwed both ends for iron pipe of 25 mm bore ISI marked. all as specified and directed
Supply and fixing in replacement Gate valve, screwed both ends for iron pipe of 20 mm bore ISI marked. all as specified and directed.
Supply and fixing in replacement Gate valve, screwed both ends for iron pipe of 25 mm bore ISI marked. all as specified and directed.
Supply and fixing in replacement Gate valve, screwed both ends for iron pipe of 40 mm bore ISI marked. all as specified and directed
Supply and fixing in replacement butterfly valve, screwed both ends for iron pipe of 50 mm bore ISI marked. all as specified and directed.
Supply, fix, installation and testing (replacement) of ultra sonic non contact sensor for level monitoring for overhead tank with following specification:- Principal:- Ultrasonic sound waves water level sensing. O/P Port:- 4-20 ma/0-20 V Data Transmitting out put port SCADA Operation output port Range 8 Meters with anti theft device (micro controller based). make: Unison/Crystal/Banner/As per OEM of automation panel.
Material and labour for Cast iron fitting for CI spigot socketed/ flanged pipe bend (any type radius and angle) tapers any type (straight, bends increasing, decreasing or double socket etc) tee pieces, single branch 'Y' junction double branch cross (all socket or socket spigot or flanged) collars, cap and plugs upto 200 mm bore connection pieces one end flanged and other socket or spigot and bell mouth piece one end flanged and other end tapering as bell mouth complete all as specified and directed.
Supply & fixing in repairs of fabricated from steel including nuts, bolts, washers, welding, bending, drilling holes for bolts in any shape or size as directed inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified.
Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for supporting of CI/GI pipes,header etc all as specified and directed.
S & F in replacement of Air termination single pointed aluminium rod 12 mm dia and 300mm long fixed with 40mm dia, 4 mtr long GI Pipe incl providing flat iron clamps, nuts & bolts, embedding the GI pipe in PCC M-10 block (nominal mix) of size 30 x 30 x 40cm and connecting complete all as specified directed by Engr-in-charge. Note: GI pipe,and Pcc will be measured and paid separately.
S & F in replacement of GI tubing (light grade) 40mm dia for holding of air termination rod.
S & F in replacement of Aluminium strip 25 x 3.15 mm on OH tank with saddle on min distance of 0.5 mtr through out the aluminium strip including nuts, bolts, washers, serew complete as indicated or directed by Engineer-in- Charge.
S & F in replacement of GI strip 32 x 6mm as earth continuity conductor for loop earthing complete with fixing of seddles, nuts bolts, washers, screws complete all as specified and directed.
Cement concrete M-15 (Nominal mix) using 20mm graded crushed stone aggregates in PCC block and fixing post complete all as specified.
M&L For Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground to a depth not less than 3 mtr below normal ground level with top edge of earth plate at a depth not less than 2.25 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal, magnicium sulphate, common salt and connected with in and including GI strip of size 32x6mm by means of stainless steel bolts, nuts, check nuts and washers connected to test point 40mm bore of GI pipe (light grade) from earth plate up to testing point for protection of GI strip and 20 mm bore GI pipe (medium grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with suitable size of handle made out of 8mm dia MS bars and angle iron 40 x 40x 3mm frame for cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 2009 complete all as specified. RCC cover shall be painted with red paint over a primer coat and the rate include in the unit rate of item.
M &L in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3nos 8mm dia 25mm long hex head screw.
M &L for Cleaning of trenches/ duct and getting out loose sand/soil , spoils, rubbish, dry leaves etc and removing and depositing at 200m distance etc complete
M &L for Demolition of PCC in ground floor & pavings not exc 15 cm thickness below or above ground level etc complete.
M &L for Demolition of brick work or stone bouldern masonary built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr as specified.
M&L for bricks work with subclass 'B' bricks old size straight or curved on planexc 6m mean radius built in CM (1:4) etc complete all as specified and as directed
M & L Cement concrete type D2 1:4:8 using 40 mm graded aggregate in sub base complete all as specified and as directed.
M&L for 50mm thick cement concrete 1:2:4 type B-I using 20mm graded stone aggregate as in flooring etc complete and all as specified and as directed.
M&L rendering 15mm thick in cement plaster 1:6 on fair faces of brick work and surface finished even and smooth without using extra cement etc complete all as specified and as directed.
M&L Demolition of cement concrete (Reinforced) in ground floor & pavings not exc 15 CM thickness below or above ground level ( reinforcement cut as required to facilitate demolition) etc complete all as specified and as directed.
M&LProviding precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slab (Manholes/Drain) and similar articles including necessary moulds/formwork complete all as specified
M&L TMT bar 10 mm dia and over , cut to length, bend to as required including cranking, bending an binding with annealed wire not less than 0.9 mm dia complete all as required.
M&L PCC type B1 1:2:4 (20mm graded aggregate ) as in coping etc complete
M&L for Sand filling under floors or in foundation including watering and consolidation etc complete and all as specified and as directed
Supply, installation, testing & commisioning (replacement) of high torque motorize valve with gears and adopters self lubricating type, weather proof with gears and adopters self lubricating type, weather proof with protection against, over voltage Jamming of valve and over current protection with manual by-pass arrangement to open/Close the valve on power failure having following features:- (a) Valve size:-150 mm bore (b) Designed line pressure 4 Kg/sq cm (c) Operating angles:-90 degree (d) Disc Material:- CI with nylon coating (e) Valve type:-Butterfly valve PN 10 with geared motor on top. (f) SCADA output pot. (g) Anti theft device micro controller based (h) Torque 35 Nm running time 20s (i) Close off pressure 1200 KPA (j) Operating voltage 230 V AC with 2 in built auxiliary switches, IP 67 with control relay 24/12V & 2 Nos change over. Make: KIRLOSKAR, LEADER, ZOLOTO, L&T,BELIMO
All as per Srl item No 68 here in before but of size 100 mm bore
All as per Srl item No 68 here in before but of size 80 mm bore
All as per Srl item No 68 here in before but of size 50 mm bore
All as per Srl item No 68 here in before but of size 200 mm bore
Supply and fix PVC copper conductor cable of size 3X1.5 Sqmm under ground or alongwith overhead tank complete as directed by Engr-in-Charge .Make :Havells/HPL
Supply & fixing on wall/ laying in ground 4 pair X 1.5 Sqmm PVC insulated & PVC copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all as specied and directed. Make: L&T/ Grandlay/ KEI
Supply & fixing on wall/ laying in ground 6 pair X 1.5 Sqmm PVC insulated & PVC copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all as specied and directed. Make: L&T/ Grandlay/ KEI
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 1000 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts.
Material & Labour for cutting of shurbs/branches of trees/plant inside and outside around the installation by necessary T&P and spreading of Bleaching power around it incl cleaning of algie from bulding wall, terrace, floor and making installation presentable as directed by Engr-in-Charge.
Material and labour for providing following chart and equipment at installation (a) First aid Box-01 No (b) Electrical shock treatment chart duly framed -01 No (c) Fire fighting Chart (life saving instruction) duly framed duly framed - 01 No (d) Fire safty poster (Know the correct fire extinguiser) -01 No (e) Water supply distribution diagram duly framed -01 No (f) Wooden Display board with sliding glass cover in aluminum frame chanel of Size (2 X 1.2 X .08) mtr all as specified and directed.
Material and labour for providing following chart and equipments at installation (a) First aid Box-01 No (b) Electrical shock treatment chart duly framed -01 No (c) Fire fighting Chart (life saving instruction) duly framed - 01 No (d) Electric supply distribution diagram duly framed-01 (e) Water supply distribution diagram duly framed -01 No (f) Wooden Display board with sliding glass cover in aluminum frame chanel of Size (2 X 1.2 X .08) mtr all as specified and directed.
Material and labour for providing tripod stand with fwg spcifiecation: GI pipe Heavy duty 50 mm dia, Clamping arrangemene for hanging of chain pulley at one end including painting and polishing all as specified and directed. Note: Length of tripod should not be less than 5 mtr
Material and labour for display board of size 5 feet x 4 feet of thickness 6 inch duly made on white polyvinyl sheet exactly showing the locations of the yard and the machinary and equipments installed in the sub-station duly marked properly with the details of machinary installed with Nos, capacity/ rating and make etc with computer print letter of approved size on poly vinyl sheet, both duly illuminated with 07 watts LED bulbs 04 nos, with holder and necessary connection wire and accessories, at the back side of chart for prominent appearance duly encased in a Galavanied steel sheet frame enclosure and alongwith MES monogram and supported with 40 mm steel pipes duly polished 8 feet long grouted in PCC 1:4:8 of size 20 cm X 20 cm x 45 cm in ground including all civil works complete all as specified and approved by the Engr-in-Charge.
Supply and fixing fire bucket with hanging arrangement as per sample given duly coated with red colour as per fire order all as specified and directed
M&L for PCC M-10 (Nominal mix) using 40mm graded aggregate as in foundation.
Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a line surface.
M&L for MS work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS-1239 (Part I-1990).
M&L for Roof trusses (framed), purlins, rails and heavy bracket frame (beam, tee, angle, channel or flat section) including distence pecies, cleats etc Gde Fe-410-S.
S&F 0.63 mm th CGI sheeting, Cl-4 with two corrugation side lap, fixed with 'L' type or 'J' type cranked hook bolts washers in roof.
S&F 0.80 mm thick mild steel plain, black sheet as in ridge, hip, valley gutter, drip and straight flushing (length & girth as fixed) fixed with L'-type or 'J'-type or cranked hook bolts.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded agg) as in Sub-base to floor finishes.
M&L for 40 mm thick cement concrete (M-15), type B1 (using 20mm graded agg) as in flooring finished even and smooth using extra cement.
Rendering 10 mm thick on fair face of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified.
M&L for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer.
Preparing newly plastered or concrete surfaces of wall and applying two coats of cement based paint over a coat of white wash.
Supply and fix in replacement Air termination, single pointed rod 12 mm dia and 300 mm long in existing GI pipe of 20-25 mm dia on over head water tank all as specified and directed.
M&L for PCC block of size 30 x 30 x 30 cm type B-1, 1:2:4 (20 mm graded aggregate) with and including embedded 25 mm dia GI pipe medium grade 1.00 mtr long for fixing air termination including all necessary fixing arrangement on over head water tank all as directed.
S&F integral LED Aviation light comprising of aluminium housing with polycarbonate enclosure including taking down old one.Make:- Bajaj - Ordering product code-110731, Luminare type - BGAV302 LED, C&S cat part No LTAL 100 or equivalent.
Supply and fixing PVC Conduit of size 20 mm dia for holding the service wire for connection of Avation light on the roof of over head tank complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised iron strip 25 X 6 mm by means of nuts,bolts & washer etc. Earth strip connected upto main earth point/DBs alongwith 40 mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work all as specified and directed.
SATISH AND CO
M/S RAJ ENGINEERS
Dee Ess Construction Co
BMMJ TRADERS AND ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .