Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC 7 2 1813 5 A ADJ TO POST OFFICE INDUSTRIAL ESTATE SANATHNAGAR HYDERABAD TELANGANA 500018 | MEDCHAL MALKAJGIRI | TELANGANA | 500018 | ₹3.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.8 Cr+₹14.1 L (3.89%)Rejected-Finance 2ND STAGE BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | ₹3.8 Cr+₹14.1 L (3.89%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹5.9 Cr+₹2.3 Cr (64.3%)Rejected-Finance E 128 SECTOR 63 NOIDA NOIDA NOIDA UTTAR PRADESH 201301 INDIA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹5.9 Cr+₹2.3 Cr (64.3%) | L3 | Rejected-Finance Rejected |
| 4 | Rejected-Technical | - | - | Rejected-Technical Techno Commercially rejected |
| 5 | Rejected-Technical | - | - | Rejected-Technical Techno Commercially rejected |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
29 Nov 2024, 2:30 pmClosed
General Manager (Contracts)
Indian Oil Corporation Limited (Pipelines Division) A-1, Udyog Marg, Sector-1, NOIDA (UP) 201 301, INDIA
Design, Supply, installation, testing and commissioning of Instrumentation, PLC-based Control System, Fire and Gas Alarm detection system at Meeramandali CUF and T-point station under Meeramandali CUF Project and AMC for a per of 5 years after DLP
2024_PLHO_180859_1
PLCC/Meeramandali Control Systems/TandI/24107
Open Tender
Instrumentation - All
Works
275 days
Odhisha and West Bengal
Please refer Tender documents.
9 documents required · 9 mandatory
₹99,000
Yes
Online through VC
11 Feb 2025
22 Oct 2024
2 Dec 2024
22 Oct 2024
29 Nov 2024
30 Oct 2024
23 Oct 2024 - 29 Oct 2024
25 Oct 2024
Amount
CONTROL SYSTEM WORKS
10 SUPPLY
Dual Redundant, hot standby, PLC (microprocessor based) system, fault avoidant, complete with Processor, I/O modules, Serial interface modules, Media Converters, Relay Modules,TBs, MCBs, Data Panel (wherever applicable), interconnecting cables, data cables, Managed L-2 Switches (2 Nos with min 16 Ports each) with optical as well as copper ports , Marshalling Panels, rack power supply (dual-redundant), interrogation power supplies (dual-redundant), software auto-manual stations, emergency shutdown switch, diagnostics, firmware, power distribution cabinets, Lightning protection devices and all installation materials etc. so as to make the system complete in all respects as per system configuration, I/O list and tender specifications.
Meeramandali CUF station
Active Barriers as per technical specifications
For DI
For AI
For A/O
For Pulse
Surge Protection Devices as per technical specifications
For Analog signals (AI/AO)
For RS 232/485 signals
For LAN application
3 Phase 4 wire (415 V) TT applications
1 Phase 2 wire (230 V) applications
Flow Computer complete with software for meter proving and tables as per API for petroleum products, turbine / mass flow meter inputs, Density meter inputs, Barriers for pulse inputs, TBs for all IOs etc as per the tender specifications & data sheet.
Process PLC Programming Terminal as per tender specifications, along with accessories and softwares as per scope of work and technical specifications.
Server cum Operator work station as per tender specifications for Control System HMI , along with accessories and softwares as per scope of work and technical specifications.
Supply of 23" Display Monitor as per tender specifications.
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. with optical 1G ports 2 nos. (with SFP & OFC patch cords), complete in all respects as per tend er specifications (1 Set Comprises of 2 switches)
LaserJet Printer, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per tender specs & datasheet
Industrial Grade Ethernet to 2-4 port Serial Gateway/ MODBUS TCP to MODBUS RTU Converter with required connectors, cables, power supply etc. as per tender specifications. (1 set comprises 2 converters)
Industrial grade Serial to Fiber Optic Converter compatible to Owner supplied fibre & supply of patch cords, pig tails, connectors etc. as per tender specifications. (1 SET comprises of media converter at both ends with accessories)
Industrial grade Ethernet to Fiber Optic Converter compatible to Owner supplied fibre & supply of patch cords, pig tails, connectors etc. as per tender specifications.(1 SET comprises of media converter at both ends with accessories)
Industrial grade Serial to Ethernet convertor with required connectors, cables, power supply, etc (1 set comprise of 02 converters) Material to be supplied with RJ45 Configuration kit i.e. One RJ45 to DB9F adapter and one Ethernet crossover cable to be supplied with each module.
Industrial Grade Networking & Optical fibre accessories including LIU, network termination boxes/ fibre management system, pig tails, patchcords, connectors for the complete control System as per tender specifications. (1 set comprises of 2 nos. with all accessories)
PLC programming / Ladder logic software etc. for Dual redundant PLC's
MMI Software of same make as the PLC (including one time license fee) etc as per the tender specification. 1 Set means 5 MMI license with one MMI having capability of editing/Creating new graphic screens (i.e. for Control system HMI (03 nos), F&G HMI (01 no.) and programming terminal (1 no)).
PLC Spares
PLC Processor Module
PLC Processor power supply
Rack communication module
Rack power supply
Digital input module
Digital output module
Analog input module
Analog output module
Serial Interface communication module
Field interrogation power supply
Ethernet interface communication module
UPS for Control system
10 KVA in (1+1) parallel redundant equal load sharing configuration with Power SPDs and ACDB excluding battery as per the tender specifications
Sealed maintenance free 2V VRLA battery in dual string for 4 hrs backup considering aging, temperature & capacity factors complete with all interconnecting cables, glands, battery cables, battery stands, AC distribution boxes, connectors & lugs etc as per the tender specifications for 10 KVA UPS.
5 KVA in (1+1) parallel redundant equal load sharing configuration with Power SPDs and ACDB excluding battery as per the tender specifications
Sealed maintenance free 2V VRLA battery in dual string for 4 hrs backup considering aging, temperature & capacity factors complete with all interconnecting cables, glands, battery cables, battery stands, AC distribution boxes, connectors & lugs etc as per the tender specifications for 5 KVA UPS.
1 KVA UPS with 20 minutes battery back-up for SIC Terminal/ Electrical LT control supply
UPS Spares
PCB's, one of each type for 10 KVA UPS
PCB's, one of each type for 5 KVA UPS
Console Desk & Other Furniture items
Console Desk suitable for mounting of all the SCC computers, telephone instruments, conference set, station logbook etc, complete as per tender specifications & datasheet.
Upto 10 sections (excluding pie sections
File Cabinet/ Spares cabinet : approx. 2 m height for industrial file/ spares storage. Glass front .
Supply of CAT6 cable (unarmoured) as per tender specifications
Supply of CAT 6 Cable (Armoured) as per tender specifications
Supply of Armoured Power cable (3CX2.5 sqmm)
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
IR Based explosion proof & weather proof (Point type) Hydrocarbon detectors along with all mounting & other accessories as per tender specifications.
Multi sensor detectors (with relay based output) along with all mounting & other accessories for installation at BV-RTU locations as per the tender specifications
Explosion proof heat detectors for telecom battery room at unattended stations as per technical specifications
Manual Call Point (Explosion Proof & Weather Proof) for hazardous area along with all mounting & other accessories as per the tender specifications.
Beacons (Explosion Proof & Weather Proof) for hazardous area along with all mounting & other accessories as per the tender specifications.
Explosion Proof / Weather Proof Hooters (for hazardous area) along with all mounting & other accessories as per the tender specifications.
Portable Gas Detector with controller, audio-visual alarm and suitable (intrisically safe) for hazardous area classified as classification Class I, Div. I Group C&D as per API-RP-500 as per tender specification
Surge Protection Devices for analog signals from 3 wire Infrared Hydrocarbon Detectors
2 Pair x 1.5 Sq. mm, unarmoured FRLS cable compliant to BS:5308, as per the tender specifications for indoor applications to be laid through conduits.
20 mm ISI marked GI conduit along with all fittings & fixtures likeTees, bends, junction boxes, etc for installation of various fire detectors in building
Flame proof and weather proof junction boxes including supply of EP/WP double compression cable glands, plugs for unused cable entries including EP/WP certificates as per the tender specifications for IR type hydrocarbon detectors in hazardous areas.
Weather proof junction boxes including supply of double compression cable glands, plugs for unused cable entries including WP certificates as per the tender specifications for various detectors in buildings.
Calibration kit for Point type Hydrocarbon detectors with gas cylinder, regulator, hose pipe, flowmeter etc. along with required accessories complete in all respect.
Testing Kit/Aerosol cans for Mutisensor detectors including one set of Fibreglass Telescopic Extension Pole 4.5 metres, Universal Removal Tool, Aerosol Smoke Dispenser, Protective Carrying / Storage Bag
Heat Sensing Kit/Testing Kit for explosion proof heat detectors
Digital indicator with cable glands and mounting accessories etc for density indication in field complete as per tender specification
FIELD INSTRUMENTS complete with cable glands, fittings, accessories and other installation materials etc.,complete as per tender specifications.
Pressure Transmitters with Cable glands Range max (-1 to 5 kg/cm2); Smart type; accuracy 0.075% or better Installation: 2" Pipe Mounted
Pressure Transmitters with Cable glands Range max (0 to 20 kg/cm2); Smart type; accuracy 0.075% or better Installation: 2" Pipe Mounted
Pressure Transmitters with Cable glands Range max (0 - 100 kg/cm2); Smart type; accuracy 0.075% or better Installation: 2" Pipe Mounted
Pressure Transmitters Remote Seal Type with cable glands Range max (0 to100 kg/cm2); Smart type; accuracy 0.075% or better Installation: Underground to process pipe. Transmitter: 2" pipe Mounted.
Differential Pressure Transmitter with manifold valves and Cable Glands.Range max (0 to 3 kg/cm2).Smart type; accuracy 0.1% or better
Temperature Transmitter with duplex RTD, Thermowell & Cable glands, Range max (0 to 100 degC ) Smart type; accuracy 0.1% or better Installation: Transmitter 2" pipe mounted; RTD in thermowell on process pipe above ground installation.
Temperature Transmitter with surface mounted duplex RTD, Weld pad and dual sensors & Cable glands, Range max (0 to 100 degC); Smart type; accuracy 0.1% or better Installation: Transmitter 2" pipe mounted ; RTD in weldpad welded to process pipe surface for below ground installation.
Temperature Transmitter suitable for sub soil temperature measurement with extended RTD length, cable glands, Range max (0 to 100 degC ), Smart type; accuracy 0.2% or better, Installation: Transmitter 2" pipe mounted ; RTD in underground installation at approximate 2 meter from ground level suitable for below ground installation with required ingress protection level.
Pressure switches with junction box & cable glands suitable for low pressure side, set point 1 Kg/cm2 to 10 Kg/cm2. Proof pressure 200 kg/cm2
Pressure switches with junction box & cable glands suitable for High pressure side, set point 3 Kg/cm2 to 25 Kg/cm2. Proof pressure 200 kg/cm2
Pressure switches with junction box & cable glands suitable for High pressure side, set point 22 Kg/cm2 to 70 Kg/cm2. Proof pressure 200 kg/cm2
Pressure switches with junction box & cable glands suitable for High pressure side, set point 65 Kg/cm2 to 160 Kg/cm2. Proof pressure 200 kg/cm2
Flow Switch, Thermal type, spherical tip, for 3 IN 150# Line, including calibration
Flow Switch, Thermal type, spherical tip, for 6 IN 150# line, including calibration.
Level switch top mounted SIL2 certified (sump tank) as per tender specifications
Level Transmitter for under ground liquid tank (sump tank) applications- Guided wave
Scrapper detector- 18IN, 600 # Series -Long Neck Scrapper Detector Switch- As per Tender Specification
Jacking Bracket for 600# Scrapper Detector
Field Configurator for Pressure & Temperature transmitter with Hart protocol as per tender specifications
4 1/2 Digit DMM (True RMS) as per tender specifications
Multifunction Calibrator with rechargable battery, charger, carry case, etc
Pressure Calibrator 0 - 20 bar (Portable), as per tender specifications
Pressure Calibrator 0 - 200 bar (Portable), as per tender specifications
Test Power Supply 0 - 60 V, 10 A 600 Watts, 19" rack mount, sleek 1U type as per tender specifications
Micro processor based Temperature Calibrator; Range ambient to 200 deg C, as per tender specifications
20 SERVICES
Supervison, erection, testing & commissioning of PLC at attended stations, erection and commissioning of PLC , Instruments at Station locations including supervision for termination of control cables, installation and commissioning of SCC systems, UPSs, Console Desks, Network Racks etc., laying of power cables and LAN cables for powering & interfacing the system, interfacing & integration of PLC with SCC machines and field instrumentation systems (including MVWS system) including supplied hardware/ software with station on remote & auto including development of control logics etc making all jobs complete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, services rendered etc. The Job also includes configuration at PLC end for interfacing of the PLC system with RTUs for transfering Station data to SCADA System. The job includes interfacing the PLC system with the Marketing PLC for data exchange.
Meeramandali CUF station
Interfacing of the Tank Farm Management System / Refinery Tank Gauging System
Installation, testing & commissioning of various types of detectors ,laying of signalling cables (through conduit/ clamping on wall etc), clamping / fixing of GI conduit in various building etc for integration of detectors with existing Fire Alarm panel including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete the work in all respects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of all types of detectors, material etc
Multi Sensor Detectors
Rate of Rise Heat Detectors for safe area & hazardous area \ Explosion proof heat detectors for SVs
Laying of unarmoured signal cable through GI pipe / wall / tray etc for interfacing of various type of detectors e.g. multi sensor, ROR, response indicator, hooters, beacons etc
Clamping/ fixing of GI pipe on wall/roof/cable trench etc
Deputing Resident Engineer during Installation and commissioning.
Training on supplied system including Control system, F&G etc
Submission of as built documentation as per detailed scope of work
30 COMPOSITE
Installation of explosion proof / weather proof junction boxes for marshalling of control / signalling cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Junction Boxes) complete in all respects as per specifications, approved drawings and direction of EIC / Site Engineerincluding all labour, tools, materials, glanding, ferruling etc.complete in all respects.
Installation of Hooter/Beacon in Hazardous area, terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required material such as supporting structure, cement concrete, painting, GI wire etc. complete in all respects as per specifications.
HALDIA WORKSTATION & FLOW COMPUTER
Flow Computer complete with software for meter proving and tables as per API for petroleum products, turbine / inline/ mass flow meter inputs, Density meter inputs, Barriers for pulse inputs, TBs for all IOs etc as per the tender specifications & data sheet including installation and commissioning- Haldia station
Workstation for Haldia station, as per tender specifications.
Supply of 23" Display Monitor as per tender specifications.
Comprehensive Annual Maintenance Contract for the system (including supplied facilities at all the attended stations, RCP locations, MOV locations, T-point ) for a period of 05 years after completion of defect liabillity period for the complete pipeline as per tender requirement for all locations.
AMC for 1st Year
AMC for 2nd Year
AMC for 3rd Year
AMC for 4thYear
AMC for 5th Year
Adarsha control and automation Pvt Ltd (BID ID -1038351)
ATC Engineering Systems Pvt Ltd. (BID ID -1039982)
Adarsha control and automation Pvt Ltd (BID ID -1038351)
ATC Engineering Systems Pvt Ltd. (BID ID -1039982)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .