Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC VILL JIAR P O CHOURI TEH SUJANPUR DISTT HAMIRPUR H P | SUJANPUR | HAMIRPUR | HIMACHAL PRADESH | ₹1.5 Cr | L1 | Accepted-AOC Lower amount quoted |
| 2 | L2₹1.6 CrRejected-Finance | ₹1.6 Cr | L2 | Rejected-Finance Higher amount quoted |
| 3 | L3₹1.6 CrRejected-Finance VILLAGE PO AND TEHSIL DEHRA DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | ₹1.6 Cr | L3 | Rejected-Finance Higher amount quoted |
| Sl No | Description | Qty | Unit | Vivek Dhiman L2 | Pawan Kumar Sharma L1 | aman sood L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft / hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including, shoring, strutting, planking, timbering and dewatering, wherever required, stacking the useable and unuseable material/ soil separately and after laying, jointing and testing of pipes returing the useable soil in trenches in 15 cm ( Fifteen centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil / un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts and to the entire satisfaction as per the directions of Engineer-in-Charge. | 5,240.74 | Cum | 330 ₹17.3 L | 325 ₹17.0 L | 351 ₹18.4 L |
| 2.00 | Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinths in all leads and lift and to the entire satisfaction of Engineer-in-charge | 20.18 | Cum | 4,800 ₹96,864 | 4,800 ₹96,864 | 4,951 ₹99,911.18 |
| 3.00 | Providing and laying cement concrete 1:6:12 (1cement: 6 sand 12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lift and to the entire satisfaction of Engineer-in-charge. | 35.82 | Cum | 4,400 ₹1.6 L | 4,300 ₹1.5 L | 4,551 ₹1.6 L |
| 4.00 | Brick work using common burnt clay building bricks in foundation & Plinth in cement mortor 1:4 (1cement :4 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.Iind class | 72.3 | Cum | 7,800 ₹5.6 L | 7,800 ₹5.6 L | 9,951 ₹7.2 L |
| 5.00 | 2nd. class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 (1 cement : 6 sand) in all lead and lifts and as per the directions of the Engineer-in-Charge. | 85.89 | Cum | 7,900 ₹6.8 L | 7,800 ₹6.7 L | 9,851 ₹8.5 L |
| 6.00 | Filling in plinth with sand under floors including watering ramming consolidating and dressing complete under flooring complete in all respect including carriage of materials in all leads and lifts | 16.5 | Cum | 1,460 ₹24,090 | 1,440 ₹23,760 | 1,251 ₹20,641.50 |
| 7.00 | P/L RCC seismic beam in cement concrete work 1.2:4(1cement:2sand: 4 graded stone aggregate 20mm nominal size & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in Foundations, footings bases of columns and the like and mass concrete complete in all respect including carriage of materials in all leads and lifts | 3.03 | Cum | 7,200 ₹21,816 | 6,860 ₹20,785.80 | 6,951 ₹21,061.53 |
| 8.00 | Providing and laying cement concrete 1:2:4 ( 1cement : 2 sand : 4 graded stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level complete in all respect including all leads and lifts. | 28.38 | Cum | 7,200 ₹2.0 L | 6,800 ₹1.9 L | 7,251 ₹2.1 L |
| 9.00 | 2nd class brick work using common burnt clay building bricks in super structure in all heights and depth in cement mortar 1: 6 (1cement:6sand) in all leads and lifts as per the direction of Engineer-in- charge, | 57.72 | Cum | 8,000 ₹4.6 L | 7,800 ₹4.5 L | 9,851 ₹5.7 L |
| 10.00 | Half brick work using common burnt clay building bricks in super structure above Ist floor level in cement mortor 1:4 (1cement :4 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.IInd class | 175.68 | Sqm | 990 ₹1.7 L | 900 ₹1.6 L | 1,151 ₹2.0 L |
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
9 Dec 2025, 12:00 pmClosed
Executive Engineer JSV Flood Protection Division G
Executive Engineer JSV Flood Prot. Division Gagret
Construction of Civil Work, P/L of Rising Main, S/E of pumping machinery, Providing and Laying of Distribution system and for T/well No. 68,71 at Jeetpur Baheri and T/well No. 22 at Kuneran).
2025_HPIPH_122139_1
JSV/FPDG/EA-I/6826-65 dated 29.11.2025
Open Tender
Civil Works
90 days
Executive Engineer JSV Flood Protection Division G
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,000
₹2.3 L
15 Jan 2026
29 Nov 2025
9 Dec 2025
29 Nov 2025
9 Dec 2025
29 Nov 2025
29 Nov 2025 - 9 Dec 2025
Amount
Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft / hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including, shoring, strutting, planking, timbering and dewatering, wherever required, stacking the useable and unuseable material/ soil separately and after laying, jointing and testing of pipes returing the useable soil in trenches in 15 cm ( Fifteen centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil / un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts and to the entire satisfaction as per the directions of Engineer-in-Charge.
Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinths in all leads and lift and to the entire satisfaction of Engineer-in-charge
Providing and laying cement concrete 1:6:12 (1cement: 6 sand 12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lift and to the entire satisfaction of Engineer-in-charge.
Brick work using common burnt clay building bricks in foundation & Plinth in cement mortor 1:4 (1cement :4 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.Iind class
2nd. class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 (1 cement : 6 sand) in all lead and lifts and as per the directions of the Engineer-in-Charge.
Filling in plinth with sand under floors including watering ramming consolidating and dressing complete under flooring complete in all respect including carriage of materials in all leads and lifts
P/L RCC seismic beam in cement concrete work 1.2:4(1cement:2sand: 4 graded stone aggregate 20mm nominal size & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in Foundations, footings bases of columns and the like and mass concrete complete in all respect including carriage of materials in all leads and lifts
Providing and laying cement concrete 1:2:4 ( 1cement : 2 sand : 4 graded stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level complete in all respect including all leads and lifts.
2nd class brick work using common burnt clay building bricks in super structure in all heights and depth in cement mortar 1: 6 (1cement:6sand) in all leads and lifts as per the direction of Engineer-in- charge,
Half brick work using common burnt clay building bricks in super structure above Ist floor level in cement mortor 1:4 (1cement :4 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.IInd class
Providing form work with steel plates 3.15 mm. thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centring, shutering, strutting and propping etc. with wooden battens and ballies, height of propping andcentring below supporting floor to ceiling not exceeding 4 Mtrs. and removal of the same for insitu-reinforced concrete & plain concrete work in: Flat surfaces such as soffits of suspended floors, roofs,landings and the like. Floors etc.upto 200mm. in thickness within all leads and lifts as per direction of Engineer-in-charge.
Vertical sufaces such as walls any thickness partitions and the like including attached pillasters buttresses, plinth and string courses and the the like:-
Flat surfaces such as soffits of suspended floor, roofs, landings and like floors etc. upto 200 mm in thickness.
Sides and soffits of beams,beam haunching, lintels etc. -
Providing Tor steel reinforcement for RCC work including bending binding & placing in position complete in all leads and lifts and to the entire satisfaction of Engineer-in-charge.
15 mm cement plaster in single coat on fair side of brick/stone masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and /or rounded angles not exceeding in girth and finished even and smooth in cement mortor 1:6 ( 1 cement :6 sand ) complete in all respect all including carriage of material in leads and lifts.
15mm Cement plaster in single coat on fair side of brick/stone masonry for interior plastering upto floor two level including arrises,internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:3(1cement: 3sand) within all leads and lifts as per direction of Engineer-in-charge..
15mm cement plaster in single coat on rough side of brick/stone masonery for interior plastering upto floor two level including arrises internal, rounded angles,chamfers and/or rounded angles chamfers and/or rounded angles not exceeding not exceeding 80 mm in girth & finished even and smooth in cement mortar 1:3(1cement:3sand) complete in all respect including carriage of materials in all leads and lifts
20mm cement plaster in single coat on rough side of brick/stone masonry for interior plastering upto floor two level including arrises internal, founded angles,chamfers and/or rounded angles chamfers and/or rounded angles not exceeding in girth & finished even and smooth in cement mortar 1:6(1cement:6sand) complete in respect including carriage of materials in all leads and lifts
6 mm cement plaster to ceiling in cement mortar 1:3 (1cement : 3 sand) within all leads and lifts and as per direction of Engineer-in-charge.
Pointing on brick work with cement mortar 1:3 (1cement: 4 sand) raised and cut point within all leads and lifts and as per direction of Engineer-in-charge.
P/F pressed steel door frames manufactured from commercial MS sheets of 1.25mm thickness including hinges, jump lock jamp. Bead and if required angle threshold of MS angle 50 x 25 mm or base tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamp Uc steel butt hinges 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of steel primer after pretreatment or surface as directed by Engineer-in-charge.
Providing and fixing 1mm thick M.S.sheet door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junctions and corners including all necessary fittings, complete including applying a priming coat of red lead paint using flat 30mm ximm for diagonal braces and control cross/pieces complete in all respect including carriage of material in all leads & lifts.
Providing plinth protection 50 mm thick cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) including finishing the top surface concrete smooth within all leads and lifts as per direction of Engineer-in-charge.
Cement concrete flooring 1:2:4(1cement:2 sand: 4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement within all leads and lifts as per direction of Engineer-in-charge. 40mm thick.
Cement concrete flooring 1:2:4(1cement:2 sand: 4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement within all leads and lifts as per direction of Engineer-in-charge. 50mm thick.
Providing 40x3 mm flat iron hold fast 40 cm. Long including fixing to frame with 10 mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm. 1:3:6 (1 cement: 3 sand: gragded stone aggregate 20mm nominal size) complete in all respect including carriage of material in all leads & lifts.
Providing and fixing M.S. grills of required patterns in wooden frames of windows etc. with M.S. Flats, square or round bars with round headed bolts and nuts or by screws within all leads and lifts as per direction of Engineer-in-charge.
Providing and fixing MS Handles with necessary screws complete in all respect (125 mm) complete in all respect including carriage in all leads & lifts.
Providing and faxing MS. Tower bolts (Barrel type ) with necessary screws complete in all respect (200X10) complete in all respect including carriage of material in all leads & lifts.
Providing and fixing sliding door bolts, black enamelled with nuts and screws complete in all respect (250X16) complete in all espect including carriage of material in all leads & lifts.
P/F on wall face Cast Iron rain water pipe 100mm dia i/c fitting and joints with spun yarn and cement mortar 1:2(1cement 2sand) cluding clamps complete in all respect including carriage of material in all leads & lifts.
Applying a priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works complete in all respect including carriage of material in all leads & lifts.
Painting two coats With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) complete in all respect including carriage of material in all leads & lifts
White washing with lime on undecorated wall surfaces two coats to give & even shade i/c thorougly brooming the surface to remove all dirt, dust mortar & other foreign matter, complete in all respect including carriage of material in all leads & lifts.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing M.S.fan clamp type -1 of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C slab during laying including painting the exposed portion of loop,all as per standard design complete in respect including carriage of material in all leads & lifts.
Steel work welded in built up sections,trusses & framed work including cutting, hoisting & fixing in position & applying a priming coat of red lead paint In grating, framed, guards, bars, ladders, railing, brackets & similar works within all leads and lifts as per direction of Engineer-in-charge.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant(HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required including carriage of all material within all leads and lifts. Group "C"
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC Conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of materials within all leads and lifts.
Wiring for light plug with 2X1.5 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5 Sq. mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carrige of material with in all leads and lifts.
Wiring for circuit/sub-main with 2x6 Sq. mm size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required including carriage of material with in all leads & lifts complete
Supplying & fixing metal box of 180mm.x100mm.x60mm. deep sizes (nominal size) on surface or in recess with suitable size phenolic laminated sheet covered in the front including Providing and fixing 5 pin 5/6 amps socket , outlet and 5/6 amps piano type switch connections painting etc. as required arriage of materials within all leads and lifts.:-
Supplying and fixing bakelite batten/angle holder including connections etc. as required:- including carriage of materials within all leads and lifts.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible,cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-Ceiling Fan 1200 mm sweep, Category-A 1.5 Sq mm PVCinsulated copper conductor single core cable including carriage of materials within all leads and lifts.
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required. as required complete as per direction of the Engineer-in-charge. 1X28Watt FTL (T-5) Category A.
Supplying amd erection of 40/50/63 amps rating, 10 KA breakimg capacity, 240 volts, "C" curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. Double pole Cat-A
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess completed with tinned, copper bus-bar, wire set, neutral link, earth bar, din-bar, detachable gland plate, blanking platecable, identification labels interconnections,phosphatized and power painted, including earthing etc. as required Double door 8 Way.
Supplying and errection 6 Amps to 32 Amps rating 10 KA Breaking capacity 240 volts C Curves miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. as required Category "A", single pole Cat-A
Providing Installation testing and commissioning of prewired Bourscent tube fitting 1x40 watt box type Cat Aie Bajaj make complete with balast starter and capacitor but excluding flourscent tube rod suitable to operate on 240 volt single phase AC supply directly on surface with copper wiring as required complete as per the direction of the Engineer-in-charge
Earthing with G.I earth pipe 4.5 Length,40 mm dia including accessories and providing masonary enclousers with cover plate having locking arrangements and watering pipe etc.(but without charcoal coke or and salt) complete as required including carriage of materials with in all leads & lifts.
Extra using salt and charcol for pipe earth electrodes as required.
Supply and laying 6 SWG G.I wire on surface/recess for loop earthing as required complete as per direction of the Engineer-In-Charge.
P/F street light fixture 40watts 4 feet long complete with choke starter ic connection complete as required complete as per arection of the Engineer-in-charge.
Providing, laying, jointing, & testing in trenches (to level or grade)of GMSERW pipe 95%Butt Welded &5% flanged jointing including cost of bends of below mentioned diameter confirming to IS 3183-2007 of steel grade L-210 or A and wall thickness as specified suitable to with stand required hydraulic test pressure i/c fixing of required numbers of MS nuts & bolts as per IS 1369-1967 and compressed asbestos fibre jointing gasket sheet not less than 3.00 mm thickness as per IS 2712-1998 complete in all respect to entire satisfaction of Engineer-In-Charge.The laying of pipe shall confirm to IS 5822-1994 as wll as CPHEEO manual and will include all operations such as jointing i/c flushing,cleaning & hydraulic testing complete in all respect to the entire satisfaction of the Engineer-In-Charge i/c entire carriage of material in all leads & lifts(earth work in trenches,jointing ie flanged & butt welded will be measured & paid for seperately).The pipe shall be Zinc coated on inner & outer face as per IS 4736-1986 with up to date ammendments.
GMSERW pipe 150 mm dia ( Medium grade) 4.80 mm thick
Providing and welding M.S. flanges @5% of joints, conforming to following tables as per IS 6392-1971 Latest with upto date amendments) with plain end GMS/MSERW pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of GMS/MSERW pipes to be measured and paid for seprately). The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.
MS Flange 150 mm dia 4.80 mm thick T-5
Providing circumferential butt welded joints by electrical arc welding to GMSERW pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerilikon (Adore)- CITOJET/ES/ESAB make, conforming to IS 814-1991, include Die pentration test, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer- in-Charge.
GMSERW pipe 150 mm dia 4.80 mm thick
Providing Laying, jointing and commissioning of HDPE (High Density Polyethylene pipes) of following diameter PN-4 class as per IS 4984-1995 PE-80 and jointing the pipes through butt fusion (heat fusion process) above 110 m diameter including all necessary fittings, bends, tees & reducers fabricated in accordance with IS 8360 & IS 8008 with latest ammendments & shall be provided as per site conditions (Earth work in trenches to be measured and paid separately) and jointing shall be completed in all respect including testing at site upto entire satisfaction of Engineer-in-charge.
180 mm dia HDPE pipe class PE-80, grade PN 4.00
Providing. and fixing Cast Iron Alfa valves of reputed & approved make like Kartar/Kirloskar/Leader/Bouge etc. on distribution system of confirming to IS:780-1984 with latest ammendments of appropriate class & following dia metre and capable to with stand the requisite nominal seat pressure 10Kg/ Sqmt including testing and upto entire satisfaction of Engineer -in-Charge
200 mm dia
Tube Well 68 at Jeetpur Baheri Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/Oswal/ Worthigton /LUBI / Groundfos/Hindustan/ Sabar/Seerex/Johnston / Amrut, confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ; 9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear. It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable, errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge = (Q) 14.63 LPS
Total Head = ( H) 49.88 Mts.
a) SWL in Tubewell = 12.19 Mtr. bgl.
c) R.L. point of discharge =115.15 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. = 6.10 Mtrs.
e) Drawdown = 14.02 Mtrs.
f) Static head = 42.46 Mtrs.
g) Static column lift = 42.31
Rising main.
Length 300 Mtrs.
Dia meter. 150 mm
Class GMS Pipe
Column Pipe.
Length 42.31 Mtr.
Dia 125 mm
Class GMS.
Pumping hours = 4709.27 Hours
Altitude of installations above M.S.L. ---- Mtr.
Characteristic of water.
a) Temperature Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well = 140.00 Mtr.
Dia of T/ well assembly 200 mm
Length of assembly pipe. meter .
Dia of housing pipe 300 mm
Length of housing pipe.
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing:- Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation : Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Driver Type: Electric driven.
Operating Range: -25 % to+10 % of Total head at duty point.
Delivery size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 4864-1978 with upto date amendments. ICTP Switch i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan
M.C.B of L&T/havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS; 2516-1985 with upto date amendments. O.C.B i)Make ii)Type Range 63 Amp iv) capacity
E.L.C.B of recommended L&T /Havells make as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. i) E.L.C.B Make : ii) Type : iii) Range 63 Amp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )Voltage Moniter Relay i)Make : ii) Type : iii) Range 0-500.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. 3 phase indicator lamps complete with toggles switches for indivual motors as per IS 3452 (P-I&II) with up to date amendments Bus Bar Chamber i) Type : ii) Make : iii) Rating 3 Phase Indicators
Capacitor of BHEL/GEC/L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. Capacitor i) Type : ii) Make : iii) Range 5 KVAR
Providing suitable starter of MEI/Kiburn/L&T/ Havell's/IMP/BHEL make as per IS 8544-1979 with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release, with or without 'initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type : ii) Make : Single Phase Preventor i) Type
Providing and fixing double flanged Cast iron Sluice valve of Leader / Kirloskar /BHELGLAD/FOURCES/KARTAR make for the delivery line of pump and capable of withstanding the normal seat pressure and as per IS :- 780-1984 with latest ammendments PN-1.0 Column Pipe 125 mm dia Sluice Valve i) Make : ii) Class PN 1.0
Providing double flanged swing type cast Iron Reflux valve of Kirloskar/Kartar/BHELGLAD/FOURCES/KARTAR make having Bye pass arrangement on the delivery line of the Pump and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 Part-1(Cast Iron) with latest ammendments PN 1.0 in Rising Main 150 mm dia Refluxe Valve i) Make : ii) Class PN-1.0 : ii) Material : Cast Iron
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. Pressure Gauge i) Make :
Supply of PVC jointless, flat water proof cable as per BIS 694-1998 latest with upto date ammendments suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe, solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor. The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Make : Finolex/ ii) Size Motor side 4mm²
Providing Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No. 1 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size: 125 mm dia ii) Class: GMS iii) Length:
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side From Switch to starter) i) Size mm2 ii) Make Finolex/Havells. iii) Type iv) Capacity v) Core 3. Supply Side 10.00 mm²
Providing and fixing double earthing with G.I. wire/flat of suitable thickness electrode as mentioned below complete with material such as thimble,nuts & bolts,charcoal,salt as per IS;3043-1987 with up to date amendments for motors & othere electrical eqiupments & digging of pits etc.complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 4SWG beyond 20 HP tom 30 HP.
Tube Well No.71 at Jeetpur Baheri Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Oswal/Worthigton /LUBI/ GRANDFOS/HINDUSTAN/Seerex/Sabar/Johnston / Amrut, confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ; 9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear. It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable, errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below.a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge = (Q) 20.98 LPS
Total Head = ( H) 46.46 Mts.
a) SWL in Tubewell = 6.10 Mtr. bgl.
c) R.L. point of discharge =106.99 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. = 6.10 Mtrs.
e) Drawdown = 12.19 Mtrs.
f) Static Head = 31.38 Mtrs.
g) Static column lift = 34.39
Rising main.
Length 500.0 Mtrs.
Dia meter. 150 mm
Class GMS Pipe
Column Pipe.
Length 34.39 Mtr.
Dia 125 mm
Class GMS.
Pumping hours = 4733.56 Hours
Altitude of installations above M.S.L. ---- Mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well = 141.0 Mtr.
Dia of T/ well assembly 200 mm
Length of assembly pipe. meter .
Dia of housing pipe 300 mm
Length of housing pipe. -- meter
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing:- Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation : Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Driver Type: Electric driven.
Operating Range: -25 % to+10 % of Total head at duty point.
Delivery size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 4864-1978 with upto date amendments. ICTP Switch i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan
MCB of L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB i) Make : ii) Type : iii) Range 63 Aamp. iv) Capacity
ELCB of recommended L&T /Havells make as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. i) ELCB Make : ii) Type : iii) Range 63 Amp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )Voltage Moniter Relay i)Make : ii) Type : iii) Range 0-500.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. 3 phase indicator lamps complete with toggles switches for indivual motors as per IS 3452 (P-I&II) with up to date amendments Bus Bar Chamber i) Type : ii) Make : iii) Rating 3 Phase Indicators
Capacitor of BHEL/GEC/L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. Capacitor i) Type : ii) Make : iii) Range 6 KVAR
Providing suitable starter of MEI/Kiburn/L&T/ Havell's/IMP/BHEL make as per IS 8544-1979-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release, with or without 'initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type : ii) Make : Single Phase Preventor i) Type
Providing and fixing double flanged Cast iron Sluice valve of Leader / Kirloskar /BHELGLAD/FOURCES/KARTAR make for the delivery line of pump and capable of withstanding the normal seat pressure and as per IS :- 780-1984(CIast Iron) with latest ammendments PN-1.0 Column Pipe 125 mm dia Sluice Valve i) Make : ii) Class PN1.0
Providing double flanged swing type cast Iron Reflux valve of Kirloskar/Kartar/BHELGLAD/FOURCES/KARTAR make having Bye pass arrangement on the delivery line of the Pump and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 Part-1 with latest ammendments PN 1.0 in Rising Main 150 mm dia Refluxe Valve i) Make : ii) Class PN-1.0 ii) Material : Cast Iron
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. Pressure Gauge i) Make :
Supply of PVC jointless, flat water proof cable as per BIS 694-1998 latest with upto date ammendments suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe, solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor. The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Make : Finolex/ ii) Size Motor side:-6 mm²
Providing Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No. 1 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size: 125 mm dia ii) Class: GMS iii) Length:
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side From Switch to starter) i) Size ii) Make Finolex/Havells. iii) Type iv) Capacity v) Core 3 Supply side 16 mm²
Providing and fixing double earthing with G.I. wire/flat of suitable thickness electrode as mentioned below complete with material such as thimble,nuts & bolts,charcoal,salt as per IS;3043-1987 with up to date amendments for motors & othere electrical eqiupments & digging of pits etc.complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 4SWG beyond 20 HP to 30 HP.
Tube Well No.22 at kuneran Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/Oswal/ Worthigton /LUBI / Groundfos/Hindustan/ Sabar/Seerex/Johnston / Amrut, confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ; 9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear. It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable, errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge = (Q) 18.18 LPS
Total Head = ( H) 57.25 Mts.
a) SWL in Tubewell = 22.86.0 Mtr. bgl.
c) R.L. point of discharge =104.9 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. = 7.62 Mtrs.
e) Drawdown in Tubewell = 9.14 Mtrs.
f) Static head = 45.52 Mtrs.
g) Static column lift = 49.62
Rising main.
Length 430 Mtrs.
Dia meter. 150 mm
Class GMS Pipe
Column Pipe.
Length 49.62 Mtr.
Dia 125 mm
Class GMS. (M)
Pumping hours = 4797.89 Hours
Altitude of installations above M.S.L. ---- Mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well = 140.0 Mtr.
Dia of T/ well assembly 200 mm
Length of assembly pipe. meter .
Dia of housing pipe 300 mm
Length of housing pipe. -- meter
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing:- Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation : Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Driver Type: Electric driven.
Operating Range: -25 % to+10 % of Total head at duty point.
Delivery size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 4864-1978 with upto date amendments. ICTP Switch i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan
MCCB of L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCCB i) Make : ii) Type : iii) Range 63 Amp. iv) Capacity
ELCB of recommended L&T /Havells make as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. i) ELCB Make : ii) Type : iii) Range 63 Amp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )Voltage Moniter Relay i)Make : ii) Type : iii) Range 0-500.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. 3 phase indicator lamps complete with toggles switches for indivual motors as per IS 3452 (P-I&II) with up to date amendments Bus Bar Chamber i) Type : ii) Make : iii) Rating 3 Phase Indicators
Capacitor of BHEL/GEC/L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. Capacitor i) Type : ii) Make : iii) Range 7 KVAR
Providing suitable starter of MEI/Kiburn/L&T/ Havell's/IMP/BHEL make as per IS 8544-1979-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release, with or without 'initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type : ii) Make : Single Phase Preventor i) Type
Providing and fixing double flanged Cast iron Sluice valve of Leader / Kirloskar /BHELGLAD/FOURCES/KARTAR make for the delivery line of pump and capable of withstanding the normal seat pressure and as per IS :- 780-1984(CIast Iron) with latest ammendments PN-1.0 Column Pipe 125 mm dia Sluice Valve i) Make : ii) Class PN1.0
Providing double flanged swing type cast Iron Reflux valve of Kirloskar/Kartar/BHELGLAD/FOURCES/KARTAR make having Bye pass arrangement on the delivery line of the Pump and capable of 'withstanding normal Seat Pressure as per IS:15312-1984 Part-1 with latest ammendments PN 1.0 in Rising Main 150 mm dia Refluxe Valve i) Make : ii) Class PN-1.0 : ii) Material : Cast Iron
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. Pressure Gauge i) Make :
Supply of PVC jointless, flat water proof cable as per BIS 694-1998 latest with upto date ammendments suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe, solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor. The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Make : Finolex/ ii) Size 25 mm² Motor side:-6 mm²
Providing & Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No. 1 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size: 125 mm dia ii) Class: GMS iii) Length:
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) supply side From Switch to starter) i) Size 25 mm2 ii) Make Finolex/Havells. iii) Type iv) Capacity v) Core 3. supply side 16 mm²
Providing and fixing double earthing with G.I. wire/flat of suitable thickness electrode as mentioned below complete with material such as thimble,nuts & bolts,charcoal,salt as per IS;3043-1987 with up to date amendments for motors & othere electrical eqiupments & digging of pits etc.complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 4SWG beyond 20HP to 30 HP.
Vivek Dhiman (BID ID -591269)
aman sood (BID ID -590813)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
Form6and8.pdf
Tender Documents • 1.06 MB
TermsandConditions.pdf
Tender Documents • 0.30 MB
BOQ_179183.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid