Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-Finance | L1 | Accepted-Finance BQR Conditions Satisfied | |
| 2 | L2₹2.4 L+₹44,039 (23.0%)Accepted-Finance | L2 | Accepted-Finance BQR Conditions Satisfied |
Tender Value
₹1.9 L
EMD Value
₹1,900
Closing Date
7 Mar 2020, 2:00 pmClosed
The SE/Operation/TTPS
Office of the SE/Operation/TTPS
TTPS Operation Circle MPM II ACP Repairs and replacement of failed compressor in window AC/ split AC, air cooler, renewal of worn out bed assembly, tinkering of outer cover and other related breakdown works for a period from 08.04.20 to 30.09.20
2020_EB_158774_1
SE/O/TTPS/Spec.No.19/20-21
Open Tender
Miscellaneous Works
Item Rate
176 days
TTPS
As per BQR Conditions said in NIT
5 documents required · 5 mandatory
₹0
₹1,900
11 Mar 2020
21 Feb 2020
9 Mar 2020
21 Feb 2020
7 Mar 2020
21 Feb 2020
Poor Cooling Effect AC Rectification a) Charges for dismantling of window AC’s leak testing the condenser coil, cooling coil and other related parts using Nitrogen gas arresting the leak by brazing, including re-placement of strainer and capillary tube and commissioning. b) Vacuumising and gas charging both (a) +(b)
Dismantling of window AC’s and Replacement of failed compressor by new compressor. a) Removal of failed compressor of the window AC of 0.5T, 1T, 1.5T and 2T capacity from the bed after disconnection its suction and discharges lines by brazing. b) Replacing the new compressor to the bed after altering alignment with the bed including leak testing of condenser coil and cooling coil. c) Replacement of strainer, capillary tube and copper tube of suction and discharge lines including the leak testing of the whole unit and commissioning. d) Vacuumising and gas charging (a + b + c + d)
Charges for replacement / renewal of worn out bed assembly of window AC by fabricating and welding by M.S Sheet thickness 3mm approximately size 1 m² and painting, the rates including dismantling and reassembling of compressor, condenser coil, cooling coil, fan motor etc., (consumables and materials under contractor scope).
Tinkering of window AC fan and blower housing side and top cover outer shell bed plate with 1 mm thick G.I. sheet and painting including cost of paints and consumables [G.I sheet will be supplied by the TANGEDCO].
Checking/ rewiring of electrical connection provision of knobs, fasteners etc., including cost of cable, knob, wire clip and consumables.
Replacing defective window AC at various locations from AC plant workshop as per the direction of engineer in charge.
Replacement of failed fan motors from window AC, Split AC, water cooler etc., [spare motor will be supplied by the TANGEDCO].
Replacing defective window AC at EOT crane at height of 18.5m level and unloading window AC from EOT crane at 13.5 meter level to ‘0’ meter level and ‘0’ meter to AC plant workshop as per the direction of engineer-in- charge.
Charges for replacing of defective spares such as capacitors, relay, thermostat etc., and replacement of worn out electrical wires at various locations of TTPS as per direction of engineer in charge.
Material cost: (Contractor Scope) D.A. Gas
Material cost: (Contractor Scope) Nitrogen Gas (Each 7M3)
Material cost: (Contractor Scope) Oxygen Gas (Each 7M3)
Material cost: (Contractor Scope) MS plate 3mm (weight/M2 = 23.55 kg).
DURAI ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .