Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAdmitted-Finance | ₹2.7 L | L1 | Admitted-Finance |
| 2 | L2₹3.1 L+₹36,934 (13.7%)Admitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | ₹3.1 L+₹36,934 (13.7%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical WZ 120 BUDHELLA VILLAGE VIKASH PURI WEST DELHI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical B 225 FATEH NAGAR WEST DELHI WEST DELHI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | SONI SALES and SERVICE L1 | Devraj Enterprises L2 |
|---|---|---|---|---|---|
| 1.01 | Repairing of wireless signal transmitter panel with other allied works at Delhi Gate Effluent Filling Points as per requirement comprising of the following-
Repairing of Transmitter panel with SMPS power supply arrangement of receiving the signal out of road with the help of wireless remote for start and stop 15 Amp star delta automatic panel for 2 nos to be connected with automatic phase sequence correction and phases failure protection for two nos remote stations near filling point having suitable arrangement of transmitting the signal to each starter panels by making connection with existing supply consisting of following - 04 Nos. ON/OFF indication Make: - L&T / ABB / Schneider/DJB Approved, 10 Nos. Start/Stop PB If any supply items required for completion of job work shall be provided by the contactor.Make: - L&T / ABB / Schneider/DJB Approved.
ol. | 1 | Job Complete | 82,000 ₹96,760 Lowest | 85,000 ₹1,00,300 |
| 1.02 | Repairing of Starter panel in effluent pump house having suitable arrangement of receiving the signal from transmitter panel to each starter panel by replacing of following items : - 15 HP Star / Delta Starter to be connected with existing main supply panel with following total material for 1 No. MCCB with spreader terminals and operating handle TP 100 Amp, 36 kA Motor Duty Suitable for 15 HP Make:-Siemens/L&T/ABB/ Schneider / Havells/DJB Approved, 2 Nos. Contactor TP 70 Amps AC3 Duty 220 VAC Make: - Siemens/L&T/ABB /Havells /Schneider/DJB Approved, 1 Nos. Thermal Overload Relay 17-21 Amps Make: - Siemens/L&T/Havells /ABB/Schneider/DJB Approved, 1 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T/DJB Approved, 2 Nos. Start / Stop PB Make: - L&T / ABB / Schneider /DJB Approved, 1 Nos. Star / Delta Timer Make: Siemens/L&T/ABB/Schneider/ Havells/DJB Approved. Control consisting of following: - 5 Nos. Control MCB DP 10 Amps Make: - Siemens/L&T/ABB/Schneider /Havells/DJB Approved, 5 No. Control On Indication Make:-L&T/ABB/
Schneider/DJBApproved. | 1 | Job Complete | 1,06,000 ₹1,25,080 Lowest | 1,10,000 ₹1,29,800 |
| 1.03 | Miscellaneous Material - Powder Coated Panel Enclosure with accessories Make: - DJB Approved, Suitable Control wire Make: - DJB Approved, Suitable Power Wire Make: - DJB Approved, Lugs / Glands as required for connections. | 2 | Nos | 17,600 ₹20,768 Lowest | 40,000 ₹47,200 |
| 1.04 | Testing & commissioning of the panel as above mentioned & other accessories with relevant IS as follow Check equipments specification, Continuity and earthing, MCCB mechanism and alignment, Meggaring of all equipments for phase to phase, neutral to earth and phase to earth, All functional tests, Checking for all tightness of nuts and bolts, Alignments of doors etc, Interlocking tests as per requirement of site and direction of engineer in charge | 1 | Job Complete | 23,100 ₹27,258 Lowest | 25,000 ₹29,500 |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
30 Jun 2026, 3:00 pmClosed
EE SDW V
Ring Road Andrews Ganj New Delhi 110049
Repairing of wireless signal transmitter panel with other allied works at Delhi Gate Effluent Filling Points
2026_DJB_294168_15
N.I.T. No. 03 2026 27
Open Tender
Miscellaneous Works
Works
30 days
Ring Road Andrews Ganj New Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹6,000
6 Jul 2026
23 Jun 2026
30 Jun 2026
23 Jun 2026
30 Jun 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Repairing of wireless signal transmitter panel with other allied works at Delhi Gate Effluent Filling Points as per requirement comprising of the following-
Repairing of Transmitter panel with SMPS power supply arrangement of receiving the signal out of road with the help of wireless remote for start and stop 15 Amp star delta automatic panel for 2 nos to be connected with automatic phase sequence correction and phases failure protection for two nos remote stations near filling point having suitable arrangement of transmitting the signal to each starter panels by making connection with existing supply consisting of following - 04 Nos. ON/OFF indication Make: - L&T / ABB / Schneider/DJB Approved, 10 Nos. Start/Stop PB If any supply items required for completion of job work shall be provided by the contactor.Make: - L&T / ABB / Schneider/DJB Approved.
ol. | 1 | Job Complete | 80 | ₹80 |
| 1.02 | Repairing of Starter panel in effluent pump house having suitable arrangement of receiving the signal from transmitter panel to each starter panel by replacing of following items : - 15 HP Star / Delta Starter to be connected with existing main supply panel with following total material for 1 No. MCCB with spreader terminals and operating handle TP 100 Amp, 36 kA Motor Duty Suitable for 15 HP Make:-Siemens/L&T/ABB/ Schneider / Havells/DJB Approved, 2 Nos. Contactor TP 70 Amps AC3 Duty 220 VAC Make: - Siemens/L&T/ABB /Havells /Schneider/DJB Approved, 1 Nos. Thermal Overload Relay 17-21 Amps Make: - Siemens/L&T/Havells /ABB/Schneider/DJB Approved, 1 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T/DJB Approved, 2 Nos. Start / Stop PB Make: - L&T / ABB / Schneider /DJB Approved, 1 Nos. Star / Delta Timer Make: Siemens/L&T/ABB/Schneider/ Havells/DJB Approved. Control consisting of following: - 5 Nos. Control MCB DP 10 Amps Make: - Siemens/L&T/ABB/Schneider /Havells/DJB Approved, 5 No. Control On Indication Make:-L&T/ABB/
Schneider/DJBApproved. | 1 | Job Complete | 80 | ₹80 |
| 1.03 | Miscellaneous Material - Powder Coated Panel Enclosure with accessories Make: - DJB Approved, Suitable Control wire Make: - DJB Approved, Suitable Power Wire Make: - DJB Approved, Lugs / Glands as required for connections. | 2 | Nos | 80 | ₹160 |
| 1.04 | Testing & commissioning of the panel as above mentioned & other accessories with relevant IS as follow Check equipments specification, Continuity and earthing, MCCB mechanism and alignment, Meggaring of all equipments for phase to phase, neutral to earth and phase to earth, All functional tests, Checking for all tightness of nuts and bolts, Alignments of doors etc, Interlocking tests as per requirement of site and direction of engineer in charge | 1 | Job Complete | 80 | ₹80 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_391095.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .