| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.1 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Rate within the acceptable amount | |
| 2 | L2₹1.2 Cr+₹28.7 L (30.8%)Rejected-Finance | L2 | Rejected-Finance Higher than acceptable | |
| 3 | L3₹1.2 Cr+₹30.9 L (33.2%)Rejected-Finance | L3 | Rejected-Finance Higher than acceptable | |
| 4 | L4₹1.3 Cr+₹32.4 L (34.8%)Rejected-Finance | L4 | Rejected-Finance Higher than acceptable | |
| 5 | L5₹1.3 Cr+₹35.8 L (38.5%)Rejected-Finance | L5 | Rejected-Finance Higher than acceptable |
Tender Value
Refer Docs
EMD Value
₹3.7 L
Closing Date
15 Apr 2025, 6:00 pmClosed
Commanding Officer, 108 Engineer Regiment
Commanding Officer, 108 Engineer Regiment, PIN-914108, C/o 99 APO
Supply and Construction of Fd Tech Shelter as all specified in technical specification under Job No 2649
2025_ARMY_702596_1
OT/EC/4/5/25-26/2649 (S and C)
Open Tender
Miscellaneous Works
Item Rate
369 days
Near SP Office, 108 Engr
Pl refer tender documents
6 documents required · 6 mandatory
₹0
₹3.7 L
Yes
5 May 2025
26 Mar 2025
16 Apr 2025
26 Mar 2025
15 Apr 2025
4 Apr 2025
27 Mar 2025 - 30 Mar 2025
Superstructure Supply and construction of prefabricated steel structure of size 30m x 16m x 8m clear ht incl Internal Electification, Lightning Conductor & Earthing as per Store List att. All as specified in technical specifications. Drawings.
E & M Items Distribution box 8 Way, double door SPN 240 volts copper bus bar and neutral link earthing stud conforming to IS-13032 & IS - 8623 double door type (Make : Havells/Legrand/L&T/ISI equivalent).
MCB SPN 240 Volts 32 Amps (Make : Havells/ L&T/ Standard/ISI equivalent).
MCB SP 6 to 32 Amps (Make : Havells/ L&T/ Standard/ISI equivalent).
PVC tape 19mm wide 5 m long (Make : Steelgrip/Anchor/Kinjal/ISI equivalent).
Cable PVC insulated electric cable (heavy duty)1100 volts grade multi standerd copper conductor of size 1.5 sqmm single core (FRLS) confirming to IS 1554 (Part-I) 1988 (Make : Havells /Finolex/ Polycab/ISI equivalent).
Cable PVC insulated electric cable (heavy duty)1100 volts grade multi standerd copper conductor of size 2.5 sqmm single core (FRLS) confirming to IS 1554 (Part-I) 1988 (Make : Havells /Finolex/ Polycab/ISI equivalent).
Cable PVC insulated electric cable (heavy duty) 1000 volts grade multi standerd copper conductor of size 4 sqmm single core (FRLS) confirming to IS 1554 (Part-I) 1988 (Make: Havels/Finolex/Polycab/ISI equivalent)
PVC casing capping 1” long Medium Grade (snow white) (Make:-Presto/Polycab/Finolex/ISI equivalent).
PVC casing capping 3/4” long Medium Grade (snow white) (Make:-Presto/Polycab/Finolex/ISI equivalent).
Switch Piano 5 Amp 230 Volts Flush type one way (snow white) (Make : Anchor/ SSK/Cona/ISI equivalent).
LED Tube light fittings 20W rechargeable type 230V box type 4 feet with CRCA body Pre coated white and Prewired for LED tube complete (Make : Havells/Bajaj /Philips/ Crompton/ISI equivalent).
Screw full thread 6 x 19 mm ISI Marked, 200 Nos Pkt.
PVC switch board (snow white) size 7”x4” for sockets and switches (Make : Supreme/ Polycab/ Finolex/ISI equivalent).
PVC switch board (snow white) size 8” x 10” for main switches / DB (Make : Supreme/Polycab/ Finolex/ISI equivalent).
PVC 'L' bend and 'T' junction joint for PVC casing and capping confirming to IS 3419 (Part 3) (Make : Supreme/ Polycab/ Finolex/ISI equivalent).
Switch socket combination (snow white) multipurpose 2 in 1, 15 Amp 230 Volts (Make : Anchor/ SSK/ CONA/ISI equivalent).
Switch socket combination (snow white) 5 Amp 230 Volts (Make : Anchor/ SSK/ CONA/ISI equivalent).
Service bracket 40mm dia GI Tubing medium grade 1.5 Mtr Long Make:-Jindal/Tata/Kalinga/ISI equivalent.
Service cable PVC insulated aluminium conductor, 1100 volt grade Heavy duty served with inner sheathing of PVC tap and overall PVC sheathed in service connection 10 Sqmm 2 core (Make : Havells/ Finolex/ Plaza/ISI equivalent).
Ceiling Rose three terminal (snow white) (Make : Anchor/ SSK/CONA/ISI equivalent).
LED Bulk head fitting high pressure die cast aluminum front cover with glass cover with specially design gasket with LED lamp 10 watts rechargeable type (Make :Havells/Bajaj/ Philips/Cropmtion/ISI equivalent).
PVC Flexible wire copper conductor multi stranded 0.0016/76 (Make: havells/ Finolex/ Plaza/ISI equivalent).
PVC Flexible Conduit pipe 15 mm dia (Make :- Polycab/Supreme/Finolex/ISI equivalent).
PVC Round/Square Block (Make:- Polycab/Supreme/ Finolex/ISI equivalent).
Exhaust fan 230 volts 300 mm sweep plastic body alongwith louvers and complete fittings (Make: Bajaj/Havells/Cropton/ISI equivalent)
Fire Extingusher of 1 Kg capacity of dry powder type conform to IS-13849 alongwith accessories (Make- Cease Fire/ Omex/ Alfa Fire/ ISI equivalent)
Earthing plate 600 x 600 x 6 mm Galvanised steel suitable for GI strip fittings, drilled with 2 Nos holes for 6 mm dia near one side.
CI earth pit cover of size 300 x 300 x 6 mm with Angle iron of size 20x20mm, 3 mm thick with MS frame
Funnel fitted with 20 mm diameter GI Pipe 1.5 m Long. Pipe (Make:-Jindal/Tata/Kalinga/ISI equivalent)
GI wire 4 mm diameter (For earthing).
Charcoal
Salt normal
Air termination single pointed aluminium rod 12 mm dia and 300 mm long.
Testing point terminal block make of gun metal & phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw
Aluminium strips 25 x 3.0 mm
Galvanized Iron strip 32 x 6 mm
Insulating PVC block 75x75x30 mm with insulating clamp nut and bolt (Make:-Presto/Polycab/ Finolex/ISI equivalent)
Individual standalone plastic body smoke alarm with adequate provision for fixing on wall / ceiling / roof. The unit to have sensor capable of covering area >40m2 and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 Volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two Nos of battery. (Make :- Fire End/AFO/Safe Guard/ISI equivalent)
Individual standalone plastic body heat alarm with adequate provision for fixing on wall / ceiling / roof. The unit to have sensor capable of detecting fixed temperature of 58oC and actuating an inbuilt alarm powered by 9 Volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two No of battery. (Make :- Fire End/AFO/Safe Guard/ISI equivalent)
Fire ball extinguisher of 1.3 Kg wt with suitable provision for wall mounting and capable of self activating on contact with flames. The unit to be maintenance free, non toxic, environment friendlye, and suitable for all type of fires. (Make :- AFO/Kanex/Fire Stop/Elide/Fire End/Safe Guard or ISI equivalent)
Labour Charges on Superstructure and E & M items
Constr Mtrl Cement OPC 43 Grade packed in HDPE bag each 50 Kg wt conforming to IS 8112-1989 (Make-Birla Gold/Ambuja/ Ultratech/ ACC/JK/Dalmiya/ISI equivalent)
Coarse Sand free from vegetation
Coarse aggregate 20mm graded
Coarse aggregate 40mm graded
Hardcore 63 to 90mm
Brikcks Sub Class "B'
Mild Steel Bars of size 10 mm and above dia conforming to IS 432 (Part I) 1982 (Make : TATA /SAIL/ JSW)
Mild Steel Bars of size 6 to 8mm dia conforming to IS 432 (Part I) 1982 (Make : TATA/SAIL /JSW)
Glass dividing Strip 30x4mm
Water Proofing Compound conforming to IS 2645-2003. Make : Pidilite/Dr Fixit / Fevicol)
MS Binding wire
Labour charges on Construction materials
M/S SUBHADRA STEEL (BID ID -3280752)
JSB CONSTRUCTION (BID ID -3280757)
M/S TNT ENTERPRISES (BID ID -3280766)
M/S KAMENG TRADERS (BID ID -3280768)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .