Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.5 Cr+₹11.6 L (8.40%)Rejected-Finance | ₹1.5 Cr+₹11.6 L (8.40%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.5 Cr+₹13.5 L (9.77%)Rejected-Finance | ₹1.5 Cr+₹13.5 L (9.77%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.5 Cr+₹14.8 L (10.7%)Rejected-Finance | ₹1.5 Cr+₹14.8 L (10.7%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.5 Cr+₹14.8 L (10.7%)Rejected-Finance 15 MOULYA NMH LAYOUT 1ST STAGE CHIKKA BANAVARA POST BENGALURU 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.5 Cr+₹14.8 L (10.7%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
15 Jul 2025, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore - 560013
REPAIR UPKEEP MAINT OF WATER SUPPLY INSTALLATIONS SUMPS LEAKAGE REPAIR ATTENDING DAY TO DAY WATER RELATED COMPLAINTS WATER SUPPLY PUMPING NETWORK DOZING SYSTEM WATER PIPE LINE GATE VALVE AND OTHER MISC WORKS AT AFTC 2 DC AREA AND AFS JALAHALLI
2025_MES_715128_1
8151/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.3 L
4 Aug 2025
17 Jun 2025
22 Jul 2025
17 Jun 2025
15 Jul 2025
8 Jul 2025
17 Jun 2025 - 24 Jun 2025
Amount
Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down shutters of any description n.exc 2.0 Sq.m each complete all as specified and directed.
M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panels with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F Factory made 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and directed.
Preparation of new wood or wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
Supply and fixing 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
S&F aluminium handles cast type anodised 200 mm long complete all as specified and as directed.
S&F 250mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminium alloy and fixed complete all as specified and as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
S&F 5mm thick rubber beading strips of entrance doors having width exc 3cm and not exc 5cm to arrest entry of insects including taking down existing one complete all as specified and as directed
S&F in repairs12mm thick Pre-laminated particle board, exterior grade, prelaminated on one side with decorative choice lamination and other side balancing white lamination including fixing of teak wood beading on open edges in any position such as cup boards, kitchen cupboards, Rack, drawers shutters and all other fittings, knob, hinges,beading, magnetic catch etc. fixed with screws to timber frame work complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete including taking down existing one all as specified and as directed.
Petty repair to internal/external water inlet water GI/CPVC pipe line of any size coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removing of air/dust blockage including concealed water tubing etc n exc 3m length of any height using scaffolding and making the water supply functional complete all as specified and directed.
S&F in repairs of Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) all as specified and directed.
S&F in repairs of Push tap any colour high pressure of PTMTscrewed for iron pipe and fixed, (Minimum weight 15mm-47gms) and directed
S&F in repairs of pillar tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms) and directed
S&F in repairs of Stop Valve standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) and directed
S&F Angular stop cock, valves high pressure screwed both ends iron pipe or for unioins 15mm dia, including taking down existing one complete as directed
S&F PVC (SWR) pipes single socket in any length with rubber ring joints of 75 mm bore fixed to wall including taking down existing one complete all as specified and as directed.
S&F PVC bends 75mm bore including taking down existing one complete all as specified and as directed.
S&F in repairs PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints of 110 mm bore fixed to wall/floor including taking down existing one complete all as specified and as directed.
S&F PVC bends 110mm bore including taking down existing one complete all as specified and as directed.
S&F PVC (SWR) 110mm vent cowl all as specifed including taking down existing one complete all as specified and as directed.
Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipes & fixing of chain & pull or lever after cleaning inside of all dirt, scale formation, replacement of rubber washers, syphon set, float valve,stopping of leakage etc complete all as specified and as directed
S&F 150 mm dia round/square grating of CP with or without hole including Jointed to PVC pipe complete all as specified and directed.
S&F Vitreous china squatting pan 'Orissa' Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime concrete bedding fixed in repairs all as specified and as directed.
S&F in repair PVC flush ceramic colour cistern , low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements (Make: /Parryware/Hindware/ Cera) all as specified and as directed.
S&F Wash basin vitreous china (flat back and angle back type) size 580x400mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe, fixed including taking down existing one complete all as specified and directed.
Material and labour for 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring surface finished smooth without using extra cement, including demolition of existing cement concrete & including disposal of demolished of material out side MD land complete all as specified and directed.
M&L Non-skid Ceramic tiles 7-8 mm thick, area of each tiles exc 0.09 sqm not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:4 including taking down existing old tile and removing rubbish off the premises complete all as specified and as directed.
M&L Ceramic wall tiles 7-8 mm thick designed , of size 300 x 450 mm in walls etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including rendering 10 mm thick in Cement Mortar 1:3 including taking down existing old tile and removing rubbish off the premises complete all as specified and as directed.
S&F PVC connections 15mm size with PTMT nuts of length 600 mm including taking down existing one complete and all as specified and directed.
S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
S & F in repair PVC waste pipe 32 to 40 mm dia and length n exc 2m for WHB/Sink/Urinal up to floor trap and fixed complete all as specified
M&L for cement plaster rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surface as on wall finished even and smooth without using extra cement including taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
M&L for cement plaster rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and finishing coat mixed with WPC as per manufacture instruction, finished even and smooth without using extra cement (WPC to be measured and paid separately) and taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
Supply only liquid water proofing compound of approved make.
M&L applying two coat of cement based paint over a coat of primer, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed.
M & L for preparation of new plastered surfaces of walls applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two finishing coat of oil bound distemper over a coat of primer complete all as per specified and directed.
M&L for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja,ceiling, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed. Note:-(i) The unit quoted rate shall be inclusive of material,any helght of Over Head Tank of any size and all labours, tools and plants including scaffolding required for working upto approx 15 mtr height from natural ground level and nothing extra shall be admissible on this account. (ii) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at 3 to 15 mtr height shall be mandatary and deemed to be included in the unit rate quoted.
M&L for Preparation of old decorated wall surfaces including cleaning with water rubbing of fungus complete removal, applying two coat of weather proof paint "APEX" exterior wall paint including necessary preparation to give uniform and smooth finish all as specified and directed.
M&L for Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paint, not otherwise described over 10 cm width or girth, complete all as specified and directed.
M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint over 10 cm width or girth, not other wise described complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed. (i) The unit quoted rate shall be inclusive of material,any helght of Over Head Tank of any size and all labours, tools and plants including scaffolding required for working upto approx 15 mtr height from natural ground level and nothing extra shall be admissible on this account. (ii) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at 3 to 15 mtr height shall be mandatary and deemed to be included in the unit rate quoted.
M&L for machine pressed pre polished precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and including side kerb concrete, incl removal of old unserviceable paver block and necessary demolition all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation and all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws & including dismantling of any type of old sheets in roof coverings complete all as specified & directed
S & F MS Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified & directed
M & L Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces all as specified and directed.
Site clearance by Scraping of grass/wild growth/trees n.exc 0.30m girth etc in any type of soil by manually/mechanically including removing of rubbish from the site to a distance exc, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed
M&L Plain cement concrete (1:3:6) type C1 (20 mm graded stone aggregate), 75mm thick, as in plinth protection courses/footpath, top surface of concrete finished even and smooth without using extra cement, including expansion joint 10mm thick filled with mastic filling comprising of 01 part of heated blown bitumen and 3 parts dry of sand including demolition of existing cement concrete including disposal of demolition material upto MD land complete all as specified and directed by Engineer- In - charge
Taking down of hood cover of rolling shutter of gear operated type area n exc 25sqm clear of each and greasing to all parts of rolling shutter after replacement of following unserviceable parts as required for smooth function of rolling shutter and refixing the same in position properly of any height including bracket :-
(a) Shaft 50mm mild steel pipe.
(b) Gear box sets
(c) Helical spring 600mm long.
(d) Lath patty (strips) of 75mm wide & 1.25mm thick MS.
(e) Ball bearing for 50mm dia pipe.
(f) Crancked wheel
S & F in repairs Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, lath patty, cranck wheel, helical spring, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push/ pull, manual or gear type Thickness of laths in 1.25mm and all as specified and directed.
Supply and fixing in repairs Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws,included rubber beading all complete as per architectural drawings and as directed.
Supply and fixing in repairs powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, star lock, including rubber beading complete as per architectural drawings and as directed.
Material and labour for Providing 50mm thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in floor of SWT, laid to slope for further treatment with using integral water proofing compound and demolition of old concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed. Note : WPC shall be measured and paid separately).
Dismantling structural steel work incl doors, gates but excluding framed trusses etc complete all as specified and as directed.
S&F in framed work as in doors or gates of angle,tubes or other section with gusset plates, rails, Plain sheet braces,guard bar etc., complete, to be prepared for hanging or sliding with and including hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality-A complete all as specified.
S&F Welded steel wire fabric cut to length, bent to shape required and tying with and including annealed mild steel not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members not exceeding 4kg/sqm complete all as specified and directed.
M&L Machine cut kota stone slab 20-25 mm thick as in flooring, laid over and incl 20 mm thick screed bed in CM 1:3 set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
Taking down chowkhat or frame (wooden/steel/aluminium) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed.
S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed.
S&F Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed.
Supply and fixing 150 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing aluminium handles cast type anodized 150 mm long complete all as specified and as directed.
Supply and fixing in repair 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, fixed in repair to wooden frame/welded to metal frame complete all as specified and as directed.
S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50 Sqm each pane complete all as specified and directed.
S&F frosted glass 4.0mm thick, pin head type n exc 0.5 Sqm in each pane and fixed. complete all as specified and directed.
M&L hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 Sqm in each pane complete all as specified and directed.
M&L hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 Sqm each pane complete all as specified and directed.
S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
Supply and fixing Anodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with Hangers of GI wire of suitable size (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per pecification and drawing and including dismantling old unservicable celing board & including frame with of any type and description, complete all as specified and directed.
Petty repairs to MS window shutters n. exc 2 sqm through cutting of existing any type of hinges, handle and tower bolt and fixing new box type hinges, MS handle and MS tower bolt the same window by welding and with minor repair and easying and adjustment/alignment to openable with assessories if requred ( like butt hinges, handle, tower bolt, handle, peg stay etc complete ) and replacement of window glass hacking out old putty or removing beads etc, and reputtying all glass and painting/oiling puttied surface to match existing work and including taking down and refixing in position complete all as directed. Note:-(i) The unit quoted rate shall be inclusive of material,any height of any size and all labours, tools and plants including scaffolding, safety helmet, rope required for working upto approx 15 mtr height from natural ground level and nothing extra shall be admissible on this account.
M&L PCC (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer and all as specified and directed and Demolition of old Concrete (un reinforced) of any description and in any position not otherwise specifically provided.
Demolition of brick work or stone boulder/ PCC block masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L in walling of random rubble, uncoursed, Bangalore type masonry, well bonded bedded and solidly hearted, built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4, complete all as specified and directed.
Fixing only(except stone) of random rubble, uncoursed, Bangalore type masonry well bonded, bedded, solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 complete all as specified and directed. (Note:- stone demolished under item No. 88 above shall be re-used)
M&L in plain cement concrete PCC in coping 1:2:4 type B1 (using 20 mm graded stone agg) including necessary form work complete all as specified and directed.
M & L for cement concrete 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in surface channel or drain, benching in manhole finished even and smooth with using extra cement complete all as specified and as directed.
M&L for removing old existing rubbish/battered/useless mixture of the binding materials such as cement / Lime and fine aggregate (<4.5mm retained on IS Sieve), loose/unsound weaken mixture of binding materials such as cement / Lime and coarse Aggregate (>4.5mm retained on IS Sieve), fine Aggregate of any description and in any position from existing external/internal surfaces of RCC components or any surface having average profundity of 15mm (Approx height 10m from natural ground level) by hand tool that has a long metal blade with a sharp edge at the end, chisel and hammer or using robust pneumatic chisel hand tools and removal beyond MoD land including cutting of all edges, making square shoulders of the aperture, coarsen the smooth surfaces, curettage /removing of all deterioted/decayed loose surface complete all as specified and directed by Engr-in-charge.
M&L for cleaning and removing all corrosion scales , rust , etc using emery / wire brush and finally cleaning using rust remover & cleaning agent that is one part alkaline based material, with corrosion inhibitors and dispersing agents and supplied as a clear brown solution. The specific gravity shall be 1.2 – 1.22 @ 25°C. The pH value shall be between 9.5 to 10 and the coverage shall be 5 – 6 m2/ L as per manufacturer instructions complete all as specified and directed by Engineer-in-charge.
M&L for repair to cracks and damaged existing surfaces of sump by Hydrogen Free Expanding And Plasticising Additive . It plasticizes the mix, allowing for substantial reduction in water without affecting the fluidity, thus improving the strength and impermeability, the admixture/ additive in cement to provide non‐shrink properties Cementitious Cable Encapsulation . (a). Fixing of pvc nozzles in zig-zag fashion not more than 50cm c/c on RCC surfaces on all directions as required after drilling holes in concrete, fixing pvc nozzles with fast setting mortar and covering with renderoc plug. The size of holes shall be 20mm dia and 75mm in depth complete all as specified and directed by Engineer-in-Charge.
M&L for applying Polyster Resin based Anchoring material in concrete before fixing nozzle it should typically attains a compressive strength in excess of 20N/mm @ 3 hours and and ultimate compressive strength of 70N/mm in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983as per manufacturer instructions complete all as specified and directed by Engineer-in-charge.
M&L for Shear thinning agents in RCC/ walls/ ceiling/ columns/ beams/floor/bricks cracks after opening up in “V” groove manner covering the area of 300mm from central line of crack with the depth of 8 mm complete with three components compound graded filler, E-Resins and Shear thinning agents with adjustable consistency by varying the filler component epoxy resin based complete all as specified and directed by Engineer in Charge.
M&L for applying 2 coats of two component solvent free , moisture insenstive epoxy resin coating it should achieve Compressive Strength of >70 MPa after 14days, having pot life Pot life, minutes at 27⁰C, 100 g >40 mass.The product shall have a minimum pot life of 120 Min at 35°C and an open time of atleast 4-6 Hours @ 30°C.It shall develop a minimum compressive strength of 40 MPa and a bond Strength of 11 MPa.Before applying coating surface should be cleaned from dirt, fungus and all foreign material as per manufacturer instructions complete all as specified and as directed by Engr-in-charge.
M&L for providing and fixing welded MS wire mesh weighing not less than 1Kg/Sqm of size 50mmX50mm of 2.6mm dia on the prepared surface & surface should be cleaned and be removed from dirt, fungus and all foreign material complete all as specified and directed by Engineer in Charge.
M&L for applying 2 coats of primer slurry prior to the application of the repair mortar having multiple corrosion inhibiting synergies and which is a blend of pc graded fillers corrosion inhibiting additive and re-dispersible polymers in powder form mixed with water for application by brush to coat the reinforcement/steel within 10mm of the finish surface and where chlorides are present so as to achieve adhesion bond strength of 1 MPa to steel. Pot life of 0.5 hr @ 30°C. It shall be workable for not more than 15 minutes at same temperature. The mixed density shall be not more than 2.05. The water/powder ratio shall be 0.3 by weight complete all as specified and directed by Engineer-in-charge.
M&L for providing 25 mm thick one component chloride free thixotropic fibre reinforced polymer modified repair mortar with alkali resistant synthetic fibres for exceptional resistance cracking complies ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2, tensile strength @ 7days (ASTM C 307)> 3 N/mm2, compressive strength of 35Mpa at 7 day and 45Mpa at 28 days, Adhesion bond strength > 2 N/mm2 ,Creep Strain Reduction - 10% at the outer or inner RCC surface .cement and sand can be used for finishing purpose. It should be specially adhered to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents as per manufacturer instructions complete all as specified and as directed by Engineer-in-Charge.
M&L for providing and spraying polyamine cured epoxy coating incorporating a special alkali reactive emulsion breaking system compound over the plastered surface. This impervious film prevents excessive water evaporation which in turn permits more efficient cement hydration, thus reducing shrinkage and increasing durability. It shall have a specific gravity of 1.02 and the minimum application temperature shall be 10°C and the strength of concrete complies with the internationally recognised ASTM C309-90 standards typically within the range of 200 to 285 ml/sqm, SG - 1.02 including all tools and tackles complete all as specified and directed by Engr-in- charge.
M&L for applying 3 coats of corrosion inhibiting, polymer matrix with excellent mechanical properties such as adhesion and elongation as waterproofing barrier coating. It should be non toxic and non-re-emulsifying. Should conform to JIS Z 1535 and IS-3085 and DIN-1048. having Hardness - Shore 'D' scale of 20,wet density of 1.66 g/cc, flexibility at low temperatures, tensile strength > 0.4 MPa, Elongation > 20%, adhesion to substrate greater than 1.5 N/mm², waterproofing to withstand 330 KPa positive pressure and 160 KPa negative pressure, Mixing should be done by electric rotary mixers. The substrate should be free of laitance, loose concrete, dust, oil etc. if applied on screed or any other cementitious surface the surface should be properly cured prior to application complete all as specified and directed by Engineer-in-charge
M&L for applying two coat of mixture of two monomer unsaturated liquid hydrocarbon , gaseous hydrocarbon and polymesrized them to get the high polymer dispersion emulsion successfully bonded to mortar, to improve adhesion to concrete, better durability, reduced shrinkage and increased flexibility and resistant to emulsification in damp condition modified Ensuring no porosity in new/old surface, temperatures between +5°C and +35°C, Resist to penetration of CO2 4.600 micron , compressive strength (11.5 N/mm2) at 3days strength - 11.5 (N/sqmm ) and at 28 days - 25.30N/sqmm as per manufacturer instructions complete all as specified and directed by Engineer-in-charge.
M&L for protecting and plastering of waterproofed surface Using cement based, micro- silica restoration mortar mixed with hydrolysis resistant primer cement modifier,not less than 8% of weight of micro silica restoration mortar.The product needing only addition of water at site which can be applied by trowel.cement, sand can be used for finishing purpose. It is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking. It is recommended for repair situations requiring application of mortar up to 10 mm thickness in one layer.The product shall achieve a compressive strength of 11 MPa in 1 day & 30 MPa in 28 days and a minimum flexural strength of 6 MPa @ 7 days. It shall have a tensile strength of minimum 2 MPa. It shall have a minimum bond strength of 2 MPa as per manufacturer instructions complete all as specified and as directed by Engineer-in-charge.
M&L for applying 2 coats after removal of curing membrane with emery paper two part non toxic solvent free epoxy resin coating for lining and potable water retaining structures having 100% solid contents,approved by CFTRI(USFDA-175.300)and complies to ASTM D 2370,etc non toxic cured film meets requirements as per IS 9883:1981 at 200 microns DFT overall thickness 200 microns for two coats on the water retaining portion .The coating should be applied on prepared and cured surfaces after removing loose dust, dirt etc, and mixing the materials using slow speed electric drill. It should be applied with a suitable stiff nylon type brush complete all as specified and directed by Engr-in- charge.
Note for item No. 93 to 106 :- The work for items Srl No 93 to 106 shall be executed directly by manufacturer or through their authorized and qualified applicators,of any following manufacturer only. M/s Thermax Limited, M/s Fosroc chemicals, M/s Tiki Tar Danosa India Ltd,
The contractor shall submit performance guarantee certificate for structural repair/leakage/seepage for a period of 10 years from the certified date of completion.
The unit quoted rate shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto 15 mtr height from natural ground level.
The defect liability period for the structural repair work shall be 05 (five) years from the certified date of completion of work.
A security deposit of value equal to 2.5% of the rate quoted against each item shall be retained from Final bill payment due to the contractor for the defect liability period.
M & L for 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone agg) as in PCC in Hard standing etc. with , spike rolling ,or making impression of expanded metal, while the concrete is green complete all as specified and demolition of old Concrete (un reinforced) of any description and in any position not otherwise specifically provided.
Forming Construction joints 30 mm deep x 10 mm wide filled with epoxy sealing compound of grade 'A', complete all as specified and directed.
M&L for broken stone boulders hard core of guage n.exc 63mm deposited spread and level laid in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L in repairs 300x300x25mm thick prepolished cement concrete chequered tiles jointed in neat cement slurry and pointed in white or coloured cement to match the floor and including 20mm thick screed bed in CM 1.4 and incl removal of old and necessary demolition and all as specified and directed
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation, filling and for mass concrete and all as specified and directed and demolition of old Concrete (un reinforced) of any description and in any position not otherwise specifically provided. .
M&L in repairs Pre-Cast PCC 1:3:6 type C1 (20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed.
M & L rendering 15 mm thick in CM 1:4 on brick/ concrete surfaces finished even and smooth with out using extra cement as specified and directed.
M&L Preparation of newly plastered surfaces of walls and applying two coats cement base paint on walls over a coat of alkali resistant primer complete all as specified and directed.
Dismantling posts or struts (wood, steel, or RCC) any section, any length not exc 5m including taking out embedded portion in concrete, brick work, masonry etc and all as specified and directed. and incl necessary excavation and earthwork in any type of soil for new post holes all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation, filling and for mass concrete complete all as specified and directed
S & F MS angle iron hand rails, fencing posts, flat iron including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F in repairs MS round bars 10 mm dia and over Fe 290 (Gde - E-165)cut to length bent to shape required including cranking, bending spirally, hooping for columns, hooking ends all as specified and directed.
S &F in repairs Mild steel screw bolts (machine made) dia of neck 16 to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified and directed.
Supply only of chain link fencing MS galvanised sqaure wire mesh of any size, dia of wire 4mm including line wires, to any type of standard rails, straining bolts, etc all as specified and directed.
Fixing only in repairs chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc inlcuding provision of binding wire and dismantling fencing wire mesh of any type etc all as specified and directed.
S & F in repair concertina coil of 610mm dia (in stretched position) hot dip galvanised steel wire coated with CLR ante corrosive coating making diamond shape with the help of devotail clips (18 SWG) fixed over barbed wire with the angle iron the concertina coil is to be fixed with barbed wire at points where coil touch the bottom barbed wire with the help of hog rings (14 SWG) complete,complete all as specified and directed.
S&F in repair galvanised two strand steel barbed wire 2.24 mm dia barbed wire with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire staples or steel pins etc , complete all as specified and directed. (each line wire to be measured)
Restraining and resecuring barbed wire including making good staples etc (each line wire to be measured), complete all as specified and directed.
M & L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) setting in CM 1:6 work for landings, cover slabs, manholes, chajjas, water troughs, manger shleves and similar articles with plain faces and demolition of reinforced cement concrete of any description and in any position and complete all as specified and directed.
M & L mild steel TMT bar 10mm dia and over cut to length bent to shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed.
M&L Cleaning and Removing silt, grit , mud and other materials from covered drain of any depth and size in foul condition including removing materials from the site to outside MD land including necessary removing cover slabs and replacing after cleaning complete area including making good any damages complete all as specified and as directed.
Note for item No 132 :- The unit rate is deemed to be included for Removing of accumulated earth at sides of drain of any width and depth up to 30 cm. cleaning/cutting the grass around 1 m from drain (both sides) and removing the grass waste to outside MD land. Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level . Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be carefully filled up with moorum/red bajri well rammed and levelled.
M&L in repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed.
M&L in repair of leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and as specified.
Material and labour for dismantling the existing unserviceable gully trap including chamber and material and labour for provision of salt glazed stoneware gully tarp, square or round mouth type "P" of size 180X150mm, including setting and jointing in cement mortar 1:1 plain cement concrete base in PCC 1:2:4 type B1, brick work in cement mortar 1:4 rendering in cement mortar 1:4 all around finished even and fair using extra cement RCC cover slab in RCC type B1, 1:2:4 with 6mm dia reinforcement etc, complete all as specified and as directed
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out steel/plastic/cpvc water tubing and connections complete all as specified and as directed.
Supplying and fixing in repairs of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified.
Supplying and fixing in repairs 20mm outer dia CPVC brass elbow all as specified.
M&L Taking down defective centrifugal pump set 100 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at same location, testing on full load capacity at least for 8 hrs etc, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required is more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only Air cock grease nipple suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 100HP motor capacity.
Supply and fixing of fully automatic Soft Stater of capacity of 100 HP pump including adjustable OLR relay , along with single phase preventer and display including all connected accessories including taking down of old one complete all as specified and directed. Make : L&T/ ABB/ BCH
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 40 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) , AC3 type 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 40 HP Pump sets complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay suitable for 40 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
Supply and fix as in repair TPN MCB ,415 volts,fixed type ,63 Amp, 50 Hz, with rupturing capacity 10 KA in the existing pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand
M&L for suitable size of gland packing for 100 HP pump set as per manufacturer's design complete all as specified and as directed.
M&L Taking down defective centrifugal pump set 40 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required is more than one week. (d) In case of services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only shaft sleeves suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Ball bearing suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 40 HP motor capacity.
M&L for suitable size of gland packing for 40 HP pump set as per manufacturer's design complete all as specified and as directed.
Over hauling and repair to Chemical Dosing Pump Granual based chloronome plants Range pump house by cleaning the FRP 100/150 Ltrs Tank, and cleaning of filters and NRV , checking and cleaning the delivery pipe line for chocking , cleaning of chlorination plant and maintainig properly including checking the level of oil in the gauge and topping up as and when required, checking the glands and maintain the plant in all respect and replacement of minor spare for smooth functioning of Chlorination Plant all as directed. Note:- The unit rate quoted shall be deemed to include for the cost of replacement of minor spares such as 'O' rings , nut/screws,washers,bolt, cleaning waste , tools for routine day to day maintenance and necessary servicing to keep the plants in running condition on all days including Sunday and holidays, Replacement of other major spares shall be measured and paid for separately under respective item of BOQ.
Supply only chlorine test solution in packing of 200ml bottle for testing of chlorine content in water
Supply only Chlorine dosing piston pump unit complete
Supply only PVC NRV set with glass ball for suction and delivery adopter 20 mm dia
Supply only PVC diaphram valve 25 mm dia heavy duty
Supply only Rubber ring for mixing chamber
Supply only Agitator mixing assembly with motor
Supply only Chlorine test kit with coloured sample Complete with all testing fitments and OT - solution in Rexene finished box Complete all as specified and as directed
Supply only Teflon gland square type 3 mm for smooth functioning of Chlorination plant
Clearing the bushes trunk girth not exceeding 10 .00 cm and area around valve chambers upto 1.0 mtrs and depositing rubbish at a distance not exceeding 50 mtrs from starting point complete all as specified and directed
Supply of calcium based high strength chlorination chemical for water in granular form chlorine concentration level having 65%-70% chlorine content packed in 45 Kg capacity in factory sealed HDPE Container superior quality suitable for treatment of drinking water complete all as specified and directed. Note:The material should be delivered at watersupply installation as per direction of AGE E/M on required basis during the contract period.
Chemical and physical analysis of water confirming to IS3025 - 58 (2006) second revision of various locations at AFS Jalahalli from any lab authorised by central/state govt for chemical analysis. The following test should be carried out :- (a) Bacteriological Quality of water (ref Table 6, Clause 4.1.1, IS 105000 : 2012 second revision) (b) General Parameters Concerning Substances of water (ref Table 2, Clause 4.0, IS 10500 : 2012 second revision) (c) Organoleptic and Physical Parameters of water (ref Table 1, Clause 4.0, IS 10500 : 2012 second revision) Note : Contractor shall collect the water samples and submit the test results to Engr-in-Charge all as specified and directed.
Supply Only Chlorine test kit with coloured sample Complete with all testing fitments and OT - solution in Rexene finished box Complete all as specified and as directed
Supply, install, testing and commissioning of Chemical Dosing system having top dia 540mm x bottom dia 480mm x height 575 mm, net capacity 95 - 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 800 - 900 RPM Single Phase flange mounted motor with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall along with dosing Injector of the following specification. Adjustble dosing pump max pressure 5kg/cm square & max flow rate 0 - 50 ltr / hr including all accessories such as Lead tubing, Connecting Ferrules, check valves, non return valve all as directed. Power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, etc complete all as specified and directed. Make: - Model No. VST 1011 of Ravi Enterprise or equivalent as per E-in-Cs approved make. Note: Unit quote rate shall be inclusive of taking down of old unserviceable plant and depositing same to MES store yard .
Supply ,Install, testing and commissioning in replacement of Smart control panel for dosing system with 3phase input supply and output capacity of minimum 6A and upgradable to 16A, Equipped with 20x4 Character LCD to display real time phase wise voltage. 5 mm LED Indication for fault detection including Under Voltage (380 Vac), Over load (440 Vac), Phase failure, Over Load. Weather proof IP54 enclosure indoor type complete all as specified and directed.
Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for shafts, wells, cesspits, manholes, etc. and getting out complete all as specified and directed .
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter and deposting where diserted at a level not exc. 1.50m above the starting point complete all as specified and directed .
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness of 18cm shall be considered for payment.
Taking down and relaying of existing DI water pipe lines of size 200 mm bore but of any type including all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing DI water pipe lines of size 150 mm bore but of any type includings all fittings after removal of scalling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 300 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
Supply and fixing in replacement Sluice valve of size 300 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed.
Material and Labour for dismantling the brass spindle from 300mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valve of 300 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complete all as specified and directed .
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 200 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
Supply and fixing in replacement Sluice valve of size 200 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed.
Material and Labour for dismantling the brass spindle from 200mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valve of 200 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complete all as specified and as directed.
Material & Labour as in repair for Construction of Valve chamber having inner dimensions 1200 mm x 1200 mm x 1200 mm with foundation in PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B bricks old size built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber cover shall be measured and paid seperately under relevant item of this schedule.
Supply and fixing in replacement Non return valve (NRV) of size 200 mm (ISI marked), gun metal body suitable for 200 mm dia pipe line complete all specified and directed
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed.
Material and Labour for gland packing in leaking Sluice Valve of 150 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complete all as specified and as directed.
Material and Labour for dismantling the brass spindle from 150mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Supply and fixing in replacement Non return valve (NRV) of size 150 mm (ISI marked), gun metal body suitable for 150 mm dia pipe line complete all specified and directed
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 100 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed
Material and Labour for gland packing in leaking Sluice Valve of 100 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complete all as specified and directed
Material and Labour for dismantling the brass spindle from 100mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Supply and fixing in replacement Non return valve (NRV) of size 100 mm (ISI marked), gun metal body suitable for 100 mm dia pipe line complete all specified and directed
Material & Labour as in repair for Construction of Valve chamber having inner dimensions 900 mm x 900 mm x 900 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size build in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule.
M & L for Bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road shall be provided as top layer to make good existing disturbed surfaces.
Supply and laying in repair of GI pipe light grade for cable protection of size 80mm bore with fittings, complete all as specified and directed.
Material and labour in repair for 3 ½ core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 95 Sqmm to 120 Sqmm, complete all as specified and directed.
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/S LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 315 Amp, 36 KA - 01No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 02Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 01No. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing of panel board for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old unserviceable all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Supply, fabricating, installation, testing and commisioning Feeder Pillar Box factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather, vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thrermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with 01 No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out U/s old LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 200 Amps ,36 KA - 02 Nos (Incomer). (b) On Load Change over front operated of capacity 250 Amps,4 Pole ,415 V -01 No. (c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 160 Amps ,25 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10 KA - 02 Nos. (e) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 40 Amps ,10 KA - 01 No. (f ) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (g) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (h) Space for spare feeder -01 No. Note :- (i) The Contractor shall submit the drawing of panel board for approval of GE before executing the work. (ii) Insulators, wiring, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schenider/L&T/C&S. (iv) MCCB should be ICu = 100 % ICs . (v) Make of LT Panel /FPB shall be as per mentioned in list of makes (PS).
Supply and fix as in repair 4 Pole MCCB ,415 volts,fixed type ,125 Amp, 50 Hz, with rupturing capacity 25 KA in the existing pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand
Taking down and relaying of existing DI water pipe lines of size 100/80 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 80 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
Supply and fixing in replacement Sluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed.
Material and Labour for gland packing in leaking Sluice Valve of 80 mm dia Complete including replacing/tightening the existing bolts and nuts etc. complcomplete all as specified and directed.
Material and Labour for dismantling the brass spindle from 80mm dia sluice valve in various locations and reconditioning the sluice valve by replacing stainless steel spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material & Labour as in repair for Construction of Valve chamber having inner dimensions 600 mm x 600mm x 600 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size build in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule.
Supply and fixing in replacement Non return valve (NRV) of size 80 mm (ISI marked), gun metal body suitable for 80 mm dia pipe line complete all specified and directed
Supply and fixing in replacement Non return valve (NRV) of size 65 mm (ISI marked), gun metal body suitable for 65 mm dia pipe line complete all specified and directed
M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains, branches lines such as bends (any type radious and angle) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pices,single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socketed or spigot and bell mouth piece suitable for rubber joint,tyton joint up to 300 mm bore and conforming to IS-9523: 2000 complete all as specified and directed.
Demolition of Brickwork or precast concrete block walling including wall quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and concrete articles built in cement mortar complete all as specified or directed.
M&L for Pre-cast cement concrete block masonry, type C1 (1:3:6), (using 20mm graded crushed stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and as directed.
Material and Labour for Plain Cement Concrete (1:2:4), type B1 (using 20 mm graded stone aggregate) as in Coping, bands, benching etc including finishing the concrete surfaces even and smooth without using extra cement including necessary form work etc Complete all as specified and directed.
Material and Labour for Cutting existing DI pipes of size 80 to 200 mm dia in position for insertion of new tees and socket of size 20/25 mm dia Complete all as specified and as directed.
Material and labour Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on plastered surfaces and one coat of synthetic paint on steel surfaces complete to make it operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers shall be given as per requirement by the Engineer-in-Charge.
Material and labour for Fabricate valve chamber covers made out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted cover complete all as specified and directed.
Material and labour for Painting with two coats of synthetic enamel paint over coat of zink chrome on surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed.
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 300 mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending, grinding, ncluding all accessories such as tee, elbow, collar etc and ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 200 mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding, including all accessories such as tee, elbow, collar etc and ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 150 mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee, elbow, collar etc and ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 80/100 mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee, elbow, collar etc and ensure no leakage with pressure test complete all as specified and directed. Note : Pipes and mechanical collar and Excavation and earth work shall be measured and paid seperately
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 300 mm bore complete all as specified and as directed.
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 200 mm bore complete all as specified and as directed.
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 150 mm bore complete all as specified and as directed.
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of size as per IS complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 80/100 mm bore complete all as specified and as directed.
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threding all as directed, along with provn of new GI fittings where ever required at site of size 80 to 150 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement GI tubing medium grade of size 150 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement GI tubing medium grade of size 100 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement GI tubing medium grade of size 80 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threding all as directed, along with provn of new GI fittings where ever required at site of size 40 to 50 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Note :- (a) In case of laying of CI/GI/DI pipe line is to be executed in civil area, it will be the responsibility of the contractor to obtain necessary permission for cutting of road & berm from BWSSB.
(b) For this purpose amount to be paid online to BWSSB, same is deemed to be included in unit quoted rate.
(c) The T&P like JCB, Drill Machine, Moveable Generator etc required for cutting of road shall be arranged by the contractor & no extra cost shall be paid for the same.
(d) After execution of work, the contractor will make good disturbed portion of road with bitumen or PCC complete as directed by Engineer-in-Charge. Cost of the same is deemed to be included in unit quoted rate.
Material and labour for Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Material and labour for Making arrangement to flush out the existing pipe line of any type 110 to 150 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Material and labour for Making arrangement to flush out the existing pipe line of any type 63 to 100 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Material and labour for Making arrangement to flush out the existing pipe line of any type upto 50 mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 280 to 283 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This shall be inclusive in quoted rate. (ii) Excavation and earth work required shall be measured and paid seperately. (iii) The flushing out shall be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This shall be inclusive in quoted rate.
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm complete all as specified and directed.
Taking down defective centrifugal pump set 20 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) type with add on aux contact 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 25/20 HP Pump set complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay suitable for 20 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
M&L for suitable size of gland packing for 20 HP pump set as per manufacturer's design complete all as specified and as directed.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 20 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 20 HP motor capacity.
Taking down defective centrifugal/Monoblock pump set 10 HP to 15 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) with add on aux contact 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 15/10 HP Pump sets complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay 15 to 21 A for 15/10 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 10 HP to 15 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
M&L for suitable size of gland packing for 10 HP to 15 HP pump set as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 10 HP to 15 HP motor capacity.
Material and labour for Attending day to day water supply service related complaints like choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, etc, applying necessary engineering efforts like by dismantling of pipes and fittings to clean and remove blocking objects, descaling of pipes and re-fixing of pipes on wall etc to restore the proper flow of water to service tanks all as specified and directed .
Note :- (a) The contractor has to attend above mentioned job in any location of entire AFTC, 2DC Area & AFS Jalahalli
(b) The service tanks are positioned on roof top of multi storied buildings upto three storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc.
(c) The cost of rethreading upto GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate.
(d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard.
(e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate.
(f) In case of any delay in attending the complaint for more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(g) If the delay is more then 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 7 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(h) The decision of the Accepting Officer in this regard shall be final and binding.
Supply and fix of PVC water tank 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed
Supply and fix in replacement lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed suitable for 500 to 1000 Ltrs cap of tanks.
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20 mm complete all as specified and directed
Supply & Fix as in replacement GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed.
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threding all as directed, along with provn of new GI fittings where ever required at site of size upto 20 mm bore complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement GI tubing medium grade of size 20 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed.
Supply & Fix as in replacement GI tubing medium grade of size 15 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm complete all as specified and directed.
S & F in replacement fancy type Bib tap, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe fixed of size 15 mm complete all as specified and directed.
Supply and fix of PVC water tank 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed
Supply and fix in replacements lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed suitable for 1000 to 2000Ltrs cap of tanks.
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25 mm complete all as specified and directed
Supply and fix PVC water tank 2000 Ltrs Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as directed incl disconnecting existing old tank of any description and capacity complete all as specified and directed
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 40mm complete all as specified and directed
Supply and fixing Framed brackets/staging to OH Tank of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, hinges and handles etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel for fabrication of valve pit chamber, raising main support and motor foundation supports etc.
Taking down defective centrifugal /Monoblock pump set 5 HP to 7.5 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only coupling bolt with nuts suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Ball bearing suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only shaft sleeves suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 5 HP to 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 5 HP to 7.5 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
M&L for suitable size of gland packing for 5 HP to 7.5 HP pump set as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 5 HP to 7.5 HP motor capacity.
Taking down defective centrifugal /Monoblock pump set upto 4 HP to by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable forupto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation /base, cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation/ base of sunction sweeper by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the up to 4 HP motor capacity.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the upto 5 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
Supply and fix as in repair TPN MCB ,415 volts,fixed type ,40 Amp, 50 Hz, with rupturing capacity 10 KA in the existing pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand
S & F in repair Over load Relay range of (0.1 -1.5 Amps ) , max- 5A (as per sample) for 0.5 HP starter (Dol/Star delta) complete all as directed .
S & F in repair Over load Relay range of (1.6 -2.5 Amps ) , max-10A (as per sample) for 1.5 HP starter (Dol/Star delta) complete all as directed.
Supply & fix in replacement Single phase preventer for motor in the existing panel board with new one at water supply installations complete all as specified and as directed.
Supply & fix in replacement Star Delta timer 0-30/60 sec complete all as specified and as directed.
Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 70 Sqmm to 95 Sqmm 3.5 core of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 250 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps 25 KA - 01 No. (Incomer). (b) Change over switch 160A, 4P front operated - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amps 25 KA - 01 No. (O/G). (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps 10 KA - 01 No. (O/G). (e) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps 10 KA - 01 No. (O/G). (f) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (g) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (h) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing of panel board for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply and fixing in repair 25 mm dia Unplasticiced PVC Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair 20 mm dia Unplasticiced PVC Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair UPVC Gate Valve of size 25 mm dia , ISI marked complete all as specified and as directed.
Supply and fixing in repair UPVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed.
Supply and fixing in repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed.
Supply and fixing in repair Chlorinated PVC Gate Valve of size 25 mm dia, ISI marked complete all as specified and as directed.
M & L for Over hauling and repair/replacement of unserviceable items of Portable RO unit of capacity 80 LPD by disconnecting all pipe lines , filters catridges, RO Membrane , motor, float valve and water storage tank, all filter catridges(Pre Activated carbon ,Post Activated carbon, inline sedimant , pre particle filter), motor carbon brushes, pressure pump diaphram, float valve,solenoid valve,12/24v SMPS power supply unit , damaged pipes lines , bends ,tee , elbow, water flow restrictor including cleaning of water storage tanks and testing (TDS ), fixing of pre filters in all respect and replacement of minor spare such as carbon brush ,tee ,elbow,pipe line,teflon tape,screws,nuts etc included in this quoted rate for smooth functioning of RO Plant complete all as specified and as directed. Note : Major spare parts are measured and paid seperately as supply only under relevant items of BOQ.
Supply only pre-activated carbon filter with clamps suitable for RO unit all as specified
Supply only Post-activated carbon filter with clamps suitable for RO unit all as specified
Supply only RO pressure Pump Dia pharm Head unit suitable for RO unit all as specified
Supply only Reverse Osmosis membrane with clamps suitable for RO unit all as specified
Supply only Inline sediment filter with clamps suitable for RO unit all as specified
Supply only pre particle filter with food grade housing arrangement and with clamps suitable for RO unit all as specified
Supply only Pressure pump 12/24v suitable for RO unit all as specified
Supply only float switch suitable for RO unit all as specified
Supply only 12/24v SMPS suitable for RO unit all as specified
Supply only solenoid 12/24v suitable for RO unit all as specified
Supply only TDS,PH,Chlorine mesauring digital device all as specified
Supply and fixing as in repair pre filter housing element with suitable size of filter to protect RO including PVC pipe of required length and all connected items complete all as specified and directed.
Cleaning of UG open static Water Tank (SWT) of the following capacities by comprising of the followings 07 (Seven) stage of cleaning process for the undermentioned capcities complete all as specified and directed:- (i) De-watering by high pressure submersible pump complete (ii) Removal of sludge/mud/silt/sand from sump and disposal out side MD land (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure complete (iv) Removing dirt and sludge by vacuum pump (v) Applying one coat of white wash internal surfaces. (vi) Replace nylon net for vent pipes & man hole cover (vii) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note : The contractor shall arrange mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the unit quoted rate is inclusive of rent/hiring charges complete.
24000 Gallons capacity Near DSC Mess
20000 Gallons capacity Near CTI Arjan Hall, CTI Out gate, Abhinav Hall
15000 Gallons capacity at CTI Old Pump House, Near Offr Mess, Near works offr office , Near Armoury, Near synthetic ground, Gurukul
10000 Gallons capacity near Armoury
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compilaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 02 Nos (Incomer). (b) On Load Change over front operated of capacity 250 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 16 KA - 01 No (O/G). (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Provn of cable Alley for output through Bus Bar upto cable size 150 Sqmm. Note :- (i) The Contractor shall submit the drawing for panel board for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Material and labour for removing the submersible pump set of capacity up to 15 HP including pipes and submersible cables complete from the exisiting bore well of depth up to 200 mtr by any suitable method i.e either manual vehicle mounted motorized system and disconnecting the pump motor to locate the faults in presence of Engr-in-Charge, transporting to Wksp and carry out repairs, reassembling, lowering to bore well after repairs, testing and commissioning complete all as specified and directed
Taking down defective open well submersible pump set 5 HP 7.5 HP to by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 5 HP 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for 5 HP 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 5 HP 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 5 HP 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 5 HP 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 5 HP 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L flat three core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 6 .0 Sq mm nominal area including taking out old unserviceable cable complete all as specified and directed. Make :- Havells/Polycab/Finolex
M&L for rewinding of open well submersible electrical motor, 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 5 HP to 7.5 HP motor capacity.
Taking out silt, liquid water sludge in solid/semi solid state / pumping out all mud sewage water from collection sump of size 5 M dia and 4 mtrs depth /Manholes STP tanks of any capacity and size and removing the same using truck mounted honey sucker of capacity minimum 4 cum and to dispose off the sludge in low lying area at any distance during Sunday and holiday as per requirement, depositing the sludge in low laying area with covering by earth over it and leaving the collection sump clean etc. complete all as specified and directed.
Note for item No 415 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed to be included for :- (i) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground leve around collection sump. Useful material shall be stacked.
(ii) De-watering by high presure submersible pump complete.
(iii) Removal of sludge & sand from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus, deposited stains using wire brush filling of cavities inside of tank with CM 1:2 mortar.
(iv) cleaning of walls , flooring and ceiling with special mechanized high pressure jet machines by high pressure jet pum 80-180 bar pressure , which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains.
(v) Anti-Bacterial Treatment of Inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water.
(vi) Cleaing/ above operations shall be executed by trained workers and technicians only.
(vii) Cost of T&P like rods, bamboos, gum shoes and hand gloves etc complete.
(viii) Driver and operator must be in possession of a valid licence and confirm the serviceability of the Truck/ machinery.
(ix) Removal of blockage of sewage lines up to one metre from collection sump including manholes by using necessary tools/ mechanically tools or manually such as passing rope knots, bamboo kamti and disc of required size including safety measures such as test for gas etc. before flushing the pipe well with water after removal of blockage of pipe complete all as specified and directed.
(x) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with in the given period only. or otherwise penality shall be imposed @ Rs 500/- per day.
Disconnecting electric connection and taking out submersible sewage cutter pump set of capacity 10 HP, 3 Phase, 415 volt from sewage well, transport to the workshop and back after making it serviceable/ repair, dismantle the motor/pump, taking out burnt winding of stator, removal of burnt insulation material from the slot, cleaning the stator slots and M&L for rewinding the stator using super enamelled, submersible grade coper winding wire of same gauge and turns, cleaning and overhauling the pump, tightening impeller complete including replacing the following unserviceable spares, reinstall the pump in original position and testing at full load capacity all as specified and directed . Make : KSB
Coil wound set with class "F" insulation
Mechanical seal lower
Mechanical seal upper
Ball Bearing Set
"O" Ring & gasket set
Fastner Set
Rotor rework with S.P Sleeve with balancing
Impeller balancing work.
Note :- An amount of Rs 3,28,567.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
SREE BUILDERS (BID ID -3355878)
VARGHESECHACKO AND CO (BID ID -3355649)
chowdeshwariconstructionco (BID ID -3355867)
Moulya Builders (BID ID -3358000)
Maruthi constructions (BID ID -3356247)
devan enterprises (BID ID -3356218)
RAMESH BABU CO (BID ID -3354499)
M/S SRI BALAJI ENTERPRISES (BID ID -3355835)
Lucky Enterprises (BID ID -3359814)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .