Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC Being lowest and reasonable bidder | |
| 2 | L2₹6.3 L+₹15,263 (2.49%)Rejected-Finance LOKMAT BHAWAN A WING 808 WARDHA ROAD RAMDASPETH NAGPUR 440010 | NAGPUR | MAHARASHTRA | 440010 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹6.5 L+₹40,493 (6.60%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹6.9 L+₹77,829 (12.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Paragon Electrotechnics L1 | SRI JD CORPORATION L2 | M/S JAINENDRA KUMAR JAIN L3 | SONA LAKSHMI ASSOCIATE L4 |
|---|---|---|---|---|---|---|---|
| 1.00Supply and fixing in repair of LED driver, including taking down street light from pole and re-fixing after repair of FWG capacity driver, complete all as specified and directed. | |||||||
| 1.01 | LED fittings 70 watt driver. | 10 | Each | 550 ₹5,500 | 435 ₹4,350 | 450 ₹4,500 | 400 ₹4,000 Lowest |
| 1.02 | LED fittings 80 watt driver. | 8 | Each | 550 ₹4,400 | 450 ₹3,600 | 450 ₹3,600 | 400 ₹3,200 Lowest |
| 1.03 | LED fittings 150 watt driver. | 5 | Each | 1,600 ₹8,000 | 1,250 ₹6,250 | 550 ₹2,750 | 500 ₹2,500 Lowest |
| 1.04 | LED fittings 200 watt driver. | 5 | Each | 2,450 ₹12,250 | 1,700 ₹8,500 | 600 ₹3,000 | 500 ₹2,500 Lowest |
| 1.05 | LED fittings 20 watt driver. | 4 | Each | 350 ₹1,400 | 415 ₹1,660 | 350 ₹1,400 | 300 ₹1,200 Lowest |
| 3.00 | M & L for boring of holes under road, pavement, hard standing by trenches technoligy using sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. | 15 | RM | 2,500 ₹37,500 | 120 ₹1,800 Lowest | 855 ₹12,825 | 1,500 ₹22,500 |
| 4.00 | Supply and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables complete all as specified and directed. | 15 | RM | 550 ₹8,250 | 550 ₹8,250 | 550 ₹8,250 | 500 ₹7,500 Lowest |
| 5.00Supply, laying, Testing and Commissioning cable XLPE insulated aluminium conductor, stranded, armoured, PVC sheathed, LT 1100 Volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed of following sizes: - | |||||||
| 5.01 | 50 sqmm, 3.5 core. | 45 | RM | 430 ₹19,350 | 360 ₹16,200 Lowest | 985 ₹44,325 | 480 ₹21,600 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
12 Feb 2026, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg P-51, 44 Wing AF Station Sonegaon, Nagpur 440005
REPAIR/ MAINT OF SECURITY AND STREET LIGHTS IN DOMESTIC AND TECHNICAL AREA AT AF STN SONEGAON, NAGPUR
2026_MES_749636_1
8555/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sonegaon
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF Sonegaon
₹19,800
Yes
10 Mar 2026
22 Jan 2026
19 Feb 2026
22 Jan 2026
12 Feb 2026
5 Feb 2026
22 Jan 2026 - 4 Feb 2026
Supply and fixing in repair of LED driver, including taking down street light from pole and re-fixing after repair of FWG capacity driver, complete all as specified and directed.
LED fittings 70 watt driver.
LED fittings 80 watt driver.
LED fittings 150 watt driver.
LED fittings 200 watt driver.
LED fittings 20 watt driver.
M & L for boring of holes under road, pavement, hard standing by trenches technoligy using sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables complete all as specified and directed.
Supply, laying, Testing and Commissioning cable XLPE insulated aluminium conductor, stranded, armoured, PVC sheathed, LT 1100 Volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed of following sizes: -
50 sqmm, 3.5 core.
25 sqmm, 3.5 core.
16 sqmm, 4 core.
10 sqmm, 2 core.
M & L for writing Pole No. on PCC/Steel poles with white synthetic enamelled paint on black background, size of letter shall be 50 mm or less complete all as specified and directed.
S & F in replacement of LED street light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 70 Watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 Sqmm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S & F in replacement of LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 200 Watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 Sqmm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S & F in replacement of LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 80 Watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 Sqmm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S & F in replacement of LED Industrial LED high bay along with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 150 Watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 Sqmm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
Rectification of cable faults including provision of straight through cable joint LT heat shrink type for cable of size 70 Sqmm 3.5 core complete all as specified and directed.
All as per Item No. 11.00 above but for cable size 95 Sqmm 3.5 core.
All as per Item No. 11.00 above but for cable size 35 Sqmm 3.5 core.
All as per Item No. 11.00 above but for cable size 25 Sqmm 4 core.
M & L for painting of Steel tubular poles of any size with two coats of aluminium paint including painting to cross arms and clamps etc. including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed. Note: - The rate quoted by the contractor shall incl the rate for supply and fixing of radium sticker/strip of make 3M or equivalent 5cm width around the steel tubular poles for 3 layear of red colour incl lapping upto 2.5cm incl best quality adhesive material applying on overlapping.
M & L for painting of Steel tubular poles of any size with one coat of red oxide primer and two coats of aluminium paint including painting to cross arms and clamps etc. including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed. Note: - The rate quoted by the contractor shall include the rate for supply and fixing of radium sticker/strip of make 3M or equivalent 5cm width around the steel tubular poles for 3 layers of red colour including lapping upto 2.5cm including best quality adhesive material applying on over lapping.
M & L for sub main wiring with 2 run of 1.5 sqmm (Nominal cross sectional are) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 1.5 sqmm (Nominal cross sectional area) PVC insulated unsheathed flame retardant low smoke cable (FRLS) with stranded copper conductor as continues earth wire connect with street light with junction box and including 20mm dia PVC rigid non-metallic conduit after and including taking down / dismantling old sub main wiring including old conduit /casing capping /wooden batten etc. of any description complete all as specified and directed. Note: - 3 Run of 1.5 Sqmm copper wire and 1 Run of PVC pipe 20mm measured as 1RM
M & L for scrapping down rusted, Electrical LT panel including rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint to the complete outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red oxide primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for outdoor type panel including MCCB's specific cabinet complete all as specified and directed.
S & F MCB TPN 415 volts 63 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S & F MCB DP 240 volts 40 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S & F MCCBs four pole 415 volts. 16 KA, 100 Amp AC thermal based fixed type in existing panel board with modification /fabrication of existing panel boards complete all as specified and directed by E-in-Charge.
S & F Thermo plastic cable looping boxes, factory made, IP 65 sheet of size 200 x 160 x 98mm separate detached gland plate and including MCB TPN 20 Amps and Bakelite connector 4 way 20 Amp with din rail, weather vermin proof, front door opening with hinge and locking arrangement fixed to pole complete all as specified and directed.
S & F in replacement Automatic street light Switch three phase max load 8-12 KW for automatic switching OFF street light at 30 Lux level and switching ON at 10 Lux of natural light the sensor along with suitable power Contactors of rating 32 Amps per Phase, MCB 40 Amps TP -01 No should be enclosed in pole/ wall mountable enclosure made of Rust proof, Electric shock proof, Termite proof and FR grade enclosure conforming to IP54. The contactors, MCBs and circuit wiring should suitable enough to take load of 25 KW equally distribution over three phase 415 Volts A/C complete all as specified and directed.
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 50mm outer diameter and 38 mm inner Diameter for laying of Electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor , pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge.
S & F Double Wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 63mm outer diameter and 50 mm inner Diameter for laying of Electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge.
S & F LED bollard in cylindrical shape with opal acrylic and IP66 protection complete all as specified and directed. Make: - Cat Part No BGBOL6059WLEDWW/WH or equivalent in Havells/Philips
S & F bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 30 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exc. 1.5 meter wide and not exc 1.5 meter in depth and getting out in any type of soil for laying of cable, pipe etc., complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exc. 25cm thick, complete all as specified and directed.
Removal of excavated materials to a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
TD8555Securitylights.pdf
Tender Documents • 1.21 MB
BOQ_839544.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .