Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NO 1 116 GANGAI AMMAN KOVIL STREET SORANJERY PATTABIRAM CHENNAI 600072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
19 Nov 2020, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
PROVISION OF GALVALUME SHEET SHED FOR BATTERY TROLLY AND ELECTRIC VEHICLE AND CERTAIN MISC B AND R REPAIRS AT TECHNICAL AREA CVRDE AVADI
2020_MES_389670_1
8336/E8
Open Tender
Civil Works
Item Rate
120 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
24 Nov 2020
24 Oct 2020
21 Nov 2020
24 Oct 2020
19 Nov 2020
6 Nov 2020
24 Oct 2020 - 6 Nov 2020
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil all as specified and directed by engineer-in-Charge.
M&L hard core of broken stone gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified and directed by engineer-in-Charge.
M&L plain cement concrete 1:4:8 type D2 (using 40mm graded aggregate) 150mm thick as sub bases all as specified and directed by engineer-in-Charge.
Cement concrete (Type B1 1:2:4 using 20mm graded agregate)40mm thick as in floor finished to receive tiles all as specified and directed by engineer-in-Charge.
M&LScreed bed or bedding layer 20mm thick for laying floor finish in CM1:6 all as specified and directed by engineer-in-Charge.
M&L hydrulic pressed coloured cement concrete tiles 300mmx300mmx25mm,set,jointed and pointed in thick neat cement slurry in floors and pointed with white cements and pigments all as specified and directed by engineer-in-Charge.
M&L for providing precast cement concrete type B1 1:2:4(using 20mm graded aggregate) in cover slab,with plain fair faces including necessary form work & set in cement mortar 1:6 all as specified and directed by engineer-in-Charge.
M&L for excavation in post holes in hard /dense soil each n.exc 0.5 cum getting out, returninng, filling in and ramming earth or broken rubble mixed with earth around inlayers not exc 25cm, watering & removal of surplus soil to a distance n.exc 50m & making good surface all as specified and directed by engineer-in-Charge.
M&L cement concrete type B2 1:3:6(using 40mm graded aggregate) in foundations of posts all as specified and directed by engineer-in-Charge.
M&L for mild steel 10mm dia and over TMT bars cut to length bent to shape required inclouding cranking bending spirally for hooping to columns hooking ends with and including mild steel wire not lessthan 0.9mm dia conforming to IS 1786 complete all as specified and directed by engineer-in-Charge.
All as per item No. 10 above but 6mm to 8mm dia all as specified and directed by engineer-in-Charge.
S&F steel work in tubular trusses including special shaped washers etc.complete usinS&F steel work in tubular trusses including special shaped washers etc.complete using ERW or induction butt welded tubes conforming to I.S.1161-1998 GRADE St 240 complete all as directedg ERW or induction butt welded tubes conforming to I.S.1161-1998 GRADE St 240 complete all as specified and directed by engineer-in-Charge.
S&F mild steel work as in door hinges hand made sliding bolt, gusset plates etc complete all as specified and directed by engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws all as specified and directed by engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet0.5mm thick of an colour having tensile strength of 550 Mpa as in north light curves ,ridges,corner boards etc fixed with self tapping screws complete all as specified and directed by engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not exceeding 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed by engineer-in-Charge..
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed by engineer-in-Charge.
M&L for 15mm thick cement plaster in CM 1:4 on concrete and brick masonry surface and finished the surfaces even and smooth without using extra cement all as specified and directed by engineer-in-Charge.
M & L three coat of white wash on new plastered surfaces on walls including preparation of new plastered surfaces all as specified and directed by engineer-in-Charge.
Removing excavated material exc. 250m but n exc. 500 m and depositing where directed all as specified and directed by engineer-in-Charge.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and directed by engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed by engineer-in-Charge.
M&L for cement concrete (1:4:8) type D2 using 40mm stone aggregate as in foundation filling and mass concrete complete all as specified and directed by engineer-in-Charge.
M&L for PCC type B0 1:2:4 (12.5 mm graded stone aggregate) as in coping including necessary formwork all as specified and directed by engineer-in-Charge.
Extra for forming fair finished drain or channel 30/45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc. all as specified and directed by engineer-in-Charge.
M&L for Cement concrete Type B1 1:2:4 (20 mm graded aggregate) in surface channels and drains all as specified and directed by engineer-in-Charge.
Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated FRLS copper cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia along with 1.5 sqmm unsheathed multi stranded copper conductor cable as earth wire PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 2 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover for One light point or one fan or exhaust fan point and one 5A socket point, controlled by one switch complete all as specified and directed by engineer-in-Charge. Note : Wiring colour code to be used as per IE rules.
All as item No 27 above but for Point wiring with 2.5 Sqmm single core PVC sheathed FRLS copper conductor cable, with PVC conduit for 5 pin socket outlet 15 amps, independent, complete all as specified and directed by engineer-in-Charge.
M & L for switch socket combination 2 in 1, 3 pin, 5 and 15 amp, flush type universal complete all as specified and as directed by the Engineer-in-Charge
S & F for Switch piano, FLUSH TYPE, Single pole, One way, 5 Amp all as specified and directed by engineer-in-Charge.
S & F for LED light fitting, 1 x 20 Watts, 230V, epoxy powder coated Aluminium housing, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by engineer-in-Charge.
M & L for ceiling rose, surface bakelite, 65x50mm, two to three terminals, complete all as specified and as directed by the Engineer-in-Charge
M & L for XLPE insulated, 2 Crore, armoured heavy duty electric cable with aluminium multi-stranded conductor, 1100 Volts grade, Cross-Sectional Area 10 sq.mm fixed to wall/ intrenches/ in pipes/ on pole etc., complete all as specified and directed by engineer-in-Charge.
Supply and fixing of Exhaust Fan, 230volts, single phase, with luvours complete size 380 mm sweep complete with all accessaories. And incl M &L for 3 core copper flexible cable suitable size from ceiling rose to exhaust fan motor complete all as specified and directed by engineer-in-Charge.
Supply & fixing for Double door, 240V, Single pole and Neutral, 4 way with 200 amps rated bus bar Sheet Metal enclosures for DBs when MCBs to be used complete all as specified and directed by engineer-in-Charge.
S & F for Isolatar Single Pole and Neutral, 240V, 20A all as specified and directed by engineer-in-Charge.
S & F MCB SP, 5 to 32 Amps 230volts, 10KA, C curve all as specified and directed by engineer-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth wire of 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to earthing test point, main DB, panel board, continuous earth lead protected by 15 mm bore GI pipe light grade, 20 mm bore dia GI pipe for watering, necessary excavation and earth work in any type of soil, PCC pit, RCC chamber cover with suitable reinforcement complete all as shown on electrical plate No.3 of SSR part-I of 2009 all as specified and directed by Engineer-in-Charge. Note:- Rate quoted shall deem to include for GI earth lead and protection pipe GI pipe light grade 15mm dia upto 7.5 m length.
K Kumar Construction
M/s GM Constructions
Mariammal Constructions
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .