| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹25.4 L+₹3.1 L (14.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹26.7 L+₹4.5 L (20.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹28.7 L+₹6.4 L (28.9%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹29.9 L+₹7.7 L (34.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹29.1 L
EMD Value
₹58,300
Closing Date
12 May 2022, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)-143530
PROVN OF SINGLE PHASE PREPAID ENERGY METERS AT TIBRI MIL STN AND UPGRADATION OF ELECTRICAL PANEL AND WIRING AT OR MD ACCN BLDG NO. P-09, P-10 AT BANA SINGH ENCLAVE UNDER GE GURDASPUR
2022_MES_518312_1
GE GSR -03/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE Gurdaspur (Tibri)
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹58,300
Yes
6 Jul 2022
14 Apr 2022
19 May 2022
14 Apr 2022
12 May 2022
30 Apr 2022
Amount
Supply and Installation of Smart Single Phase Meter with the following specifications:- (i) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to IS-16444:2015 (Reaffirmed 2020) and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. (ii) Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand. (iii) Meter should have connect / disconnect functionality operable from prepaid billing software. (iv) The meter should support open communication protocol DLMS with the software. Notes:- (a) The contractor shall be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It should be possible to run the meter in both prepaid and postpaid mode. (c) The meters shall carry 5 year warranty.
Supply and Installation of IP-67 protection Gateway compatible for remote Advanced Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It shall have internal memory to store data of at least 200 modules. It shall have inbuilt battery back-up. It shall have IP- 67 protection. It should support auto discovery of the meters and self healing mechanism for the breaks in the RF network.
Supply and Installation of smart single phase meter all as per srl iem No. 1 above but as repeaters.
Supply and Configuration of the Web based Software with following modules:- (i) Meter Data Management Module: The meter data management module shall be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system should capture and provide the following data:- (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency. (b) Monthly billing survey data for cumulative energy and maximum demand. (ii) Postpaid /Prepaid Billing Module: The billing module should collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module should include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It shall allow postpaid and prepaid functionality as required.
(iii) Occupation and Vacation Module: The system should support occupation / vacation and billing reports.the software should be collecting data from DCU. The software should provide access to staff as well as the occupant for the data. (iv) Web site: There should be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES should have the admin access to the application. The MES staff should also have the access of the key information on an android mobiles app (for admin use). (v) Customer Portal: The system should include a customer portal for the resident /occupant to log in and view their own energy / billing data. There should be android and IOS mobile apps for the user to monitor its own data and balance on regular basis.
(vi) Energy Accounting Module: The system should include features of energy accounting. The system should be able to account for total energy block wise, facility wise and should also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module:The system should provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data:The system should support meter master data repository. The system should support meter replacement process. (ix) Excel Export:The system should support export of metering and billing data in excel format. (b) The software should contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc. (c) Separate AMC contract should be made post completion of two year defect laibility period (d) Software has to be audited by CERT India empaneled firm and all its vulnerabilities be removed. Cost of audit is to be borne by the supplier.
(vi) Energy Accounting Module The system should include features of energy accounting. The system should be able to account for total energy block wise, facility wise and should also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module The system should provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data The system should support meter master data repository. The system should support meter replacement process. (ix) Excel Export.The system should support export of metering and billing data in excel format.
(x) Customer Care Module: The software should include a customer care module where the user should be log in any complaints. The service provider should monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module: The software should include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication: The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. Notes: (a) The software should be hosted on MEITY (Ministry of electronics and Information Technology) approved GCC (Government Community Cloud). It should be transferred to MES Server whenever the server is made available. (b) The software should contain two year defect liability period including all operating expenses such as GPRS charges, hosting charges etc. (c) Separate AMC contract should be made post completion of two year defect laibility period (d) Software has to be audited by CERT India empaneled firm and all its vulnerabilities be removed. Cost of audit is to be borne by the contractor.
One year comprehensive maintenance for RF Metering System including operating costs after two years of defect liability period. They should include the following items:(a) Monthly sim charges for the DCU. The contractor should ensure supply of appropriate SIMs to ensure necessary single availability. The contractor should change the sim or sim provider as required. In case of network issues, the contractor should liaison with the telecom service providers for necessary resolution.(b) Recurring SMS charges. The SMS should be issued for the payments alerts, low balance alerts and disconnection / connection alerts.(c) Software AMC. This should include necessary upgradations in the software such as support to the chrome browser changes, android version changes , IOS version changes. These changes happen on frequent basis and the software should support all the changes.
(d) Changes in the government tariff structure. The government tariff structure changes may require software upgrade. The same should be included in the AMC scope of work. (e) Remote server admin support - Ensuring adequate database back up, upgradations in the operating system, anti virus updates, database upgrade etc. (f) Reports Development - The additional reports as needed for the success of the project should be developed (g) Software installation on any alternate / backup server if required (h) The communication network monitoring and support (j) Configuration of the repaired / replaced hardware in the system (k) Trouble shooting and necessary actions to run the system as required. (l) Software bug fixing as and when required
Taking down carefully aluminium/copper point wiring for light, fan, bell, socket of point complete with fittings such as switches, ceiling roses, pendents, regulator, socket, bell etc complete at site all as specified and directed.
M&L Point wiring with PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 Sqmm, FR through and including concealed PVC conduit with fittings and PVC insulated, unsheathed multistranded, copper conductor cable continious earth wire of size 1.5 sqmm, FR, connected to common earth and including modular sunken boxes with modular cover plate and frame for mounting of accessories complete for one light point/fan point/ call bell point controlled by one, one way modular switch all as specified and directed. Note :- Cost of making good the disturbed surface plastering/filling putty alongwith matching with the existing finish is deemed to be included in the quoted rate by contractor.
All as per Srl item No 07 above but one modular socket 6A multipin 2 module on independent board.
All as per Srl item No 07 above but One modular socket, 6A multipurposes 2 module on the same board.
All as per Srl item No 07 above but one light point controlled by two, two way switches.
All as per item No. 07 above but with unsheathed multistranded copper conductor cable of size 2.5 Sqmm, FR and PVC insulated, unsheathed multistranded, copper conductor cable continious earth wire of size 2.5 sqmm, FR, connected to common earth for one modular socket 16A multipin 2 module on independent board complete all as specified and directed.
M&L for sub main wiring with two single core multi stranded PVC insulated, unsheathed copper conductor of grade 1100 Volt , FR cable of size 6 sqmm (red for phase and black for neutral) and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 32 mm wide & 6 sqmm multistranded copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth duly complete and taking down old unserviceable one. Note :- (a) Cost of making good the disturbed surface plastering/filling putty alongwith matching with the existing finish is deemed to be included in the quoted rate by contractor. (b) Three run of cable alongwith PVC conduit together shall be measured as single run.
S&F modular switch one way ,1 module 6 amps single pole complete all as specified and directed.
S&F modular socket 6A multipin, two modules complete all as specified and directed.
S&F modular switch one way 16 amps one module single pole complete all as specified and directed.
S&F modular socket, 6A/16A multipin combined 2 modules complete all as specified and directed.
S&F switch modular 2 way 6A one module complete all as specified and directed.
S&F in replacement surface mounting universal batten housing made of powder coated CRCA sheet suitable for 1 x 18/20 W LED tube rod single sided including taking down old unserviceable fitting complete all as specified and as directed.
S&F in replacement LED tube rod 20W ultra bright LED polycarbonate tubelight with very high efficacy suitable for fitting into tube light batten fitting all as directed Note :- The contractor will submit the LM-80 and LM-79 report from manufacturer to Engineer-in-Charge before incorporating the items in work.
Taking down carefully ceiling fan complete at site removing fans and depositing to MES storeyard complete all as specified and as directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete including replacement of one pair of Canopy.
S&F of modular fan regulator 2 module electronic type 5 step 100watt, 240 Volt and connecting complete all as specified and directed all as directed.
S&F Bell, AC 230 volts, single pole complete all as specified & directed.
S&F bell push modular type 6 Amp 1 module complete all as specified and directed.
S&F lamp holder PVC body angle type including 9 watt LED bulb polycarbonate body complete all as specified and directed.
M&L ceiling rose, surface bakelite 65x50mm three terminal complete all as specified and directed. .
S&F in replacement GI pipe bracket made out of GI pipe light grade 32 mm dia and bent to shape 1.5m long, MS clamps made out of MS flat iron of size 25mm x 4mm thick with nuts & bolts, washers complete including dismentling the existing GI pipe bracket and drilling of holes for nuts & bolts etc all as specified and directed
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supplying and fixed in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed. Note : All the connection of incoming and out goiing wire in MCB will be made with thimble with suitable size as directed.
S& F in repair MCB single pole 6 amps to 32 amps , 'B' series complete all as specified and directed.
S& F in repair MCB single pole 6 amps to 32 amps 'C' series complete all as specified and directed.
S& F in repair MCB single pole and neutral 40 amps , C series complete all as specified and directed.
Material and labour in replacement of distribution board made out of CRCA sheet DB vertical type double door TPN 4 Way MS sheet including fixing in the wall,cutting chases grounting and necessary patch work and white wash to match with the existing including making connections all as directed containing the folowing:- Note :- All the connection of incoming and out going wire in MCCB and MCB will be made with thimble with suitable size as directed. (a) MCCB 4 Pole 63 Amps 16 KA breaking capacity with thermal release 01 No (In coming) (b) Bus bar factory made, made out of Aluminium duly insulated wire adhesive tape RYB & black- 04 Nos. (c) MCB SPN 40 amp-04 Nos, MCB SP 40 Amp-04 Nos (Out going). (d) Connection from MCCB to bus bar will be made with aluminium strip of suitable size as directed.
Earthing complete with galvanised steel earth plate electrode 60cm ×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mmdia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including charcoal dust and common salt, testing on completion including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing all as specified & directed by Engr-in-charge. Note:- The cost of earth lead protection pipe upto 7.5m shall be deemed included in unit rate qouted for earthing all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core including taking down existing cable complete all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n.exc. 1.5m in depth for poles, stay, cable, pipe etc including cable protection and getting out copmlete all as specified.
Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft/loose soil all as specified.
Removing excavation material n. exc 50m and depositing wher directed at a level n. exe 1.5m above the starting point.
Supply and lay brick common burnt sub class "B" old size for protection of cable laid in trenches for under ground cable all as specified.
M & L Sand cushioning in trenches using fine sand to under ground cable, laid in two layers complete all as specified and directed.
M&L in replacement for 40 mm bore GI tubing light grade for cable protection fixed long the pole/under road/along the wall with necessary clamps complete all as directed.
Supply and fixing MCB protected socket outlet suitable 5/15 amp made of sheet steel encloser and plastic cover plate complete with one no 20 amp MCB SP 'C' series all as specified and directed as per Havells Model No DBOX equivalent indoasian/standard.
A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
GULSHAN SINGH GHAI AND SON
P S BUILDERS
M/S SATPAL AND BROTHERS
M/S DARSHAN & CO
dinesh enterprises
INDERJIT SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .