Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹20.9 L+₹87,515 (4.38%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance Higher | |
| 3 | L3₹21.1 L+₹1.1 L (5.44%)Rejected-Finance | L3 | Rejected-Finance Higher | |
| 4 | L4₹21.6 L+₹1.6 L (7.93%)Rejected-Finance 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L4 | Rejected-Finance Higher | |
| 5 | L5₹22.5 L+₹2.5 L (12.6%)Rejected-AOC SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L5 | Rejected-AOC Higher |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Nov 2021, 6:00 pmClosed
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
DAY TO DAY COMPLAINTS OF EXTERNAL WATER SUPPLY INCLUDING REPAIR/MAINT OF PIPE LINES AND ALLIED WORKS IN ARMD BDE AREA AT NAMS
2021_MES_479308_2
GE NAMS - 63 / 21 - 22
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
NAMS CANTT
Class D
Category b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹70,000
Yes
10 Dec 2021
29 Oct 2021
15 Nov 2021
29 Oct 2021
13 Nov 2021
8 Nov 2021
Amount
Attending external water supply complaint by excavation in soft/dense soil & taking up pipe /fitting of size 20 to 80 mm dia GI/PVC/PPR cutting, rethreading / jointing the pipe and replacing unserviceable fitting returning and filling the excavated soil and testing the joint. Note :(i) Cost of earthwork for attending the complaint shall deemed to be included in quoted rate (ii) Penalty of Rs. 300/- per Complaint will be charged from the contractor for not attending the complaint within 24 Hrs.
Attending external water supply complaint by excavation in soft/dense soil & taking up pipe /fitting of size 100 to 200 mm dia GI/PVC/DI cutting, rethreding / jointing the pipe and replacing unserviceable fitting returning and filling the excavated soil and testing the join.t Note : (i) Cost of earthwork for attending the complaint shall deemed to be included in quoted rate. (ii) Penalty of Rs. 300/- per Complaint will be charged from the contractor for not attending the complaint within 24 Hrs.
Ditto as per S items No 2 but 100 to 200 mm dia CI pipe line cutting, jointing, and repairing UNSV fittings. Note for Ser iem No-2 to 4: All necessary fittings like Tee, Bend, Socket, Union, Elbow etc will deemed to be included in the Quoted rate.
Cleaning of over head water storage tank of capacity 1 lakh gallon at 30.0 metre height, by dewatering complete water, cleaning of mud , sludge accumalated in the bottom/walls of both compartment of over head reservoir with bursh, applying bleaching powder / potassium permagnate solution for making the reservoir/Tank hygienically safe for store of water, replacing the wire mesh of top ventilator of over head water storage tank at 30 metre height & write the date of cleaning and the capacity of tank with white paint on black painted surface at ground level complete all as speciied and directed. Note- Conractor shall responsible for safety & risk of working labour at 30 m height . Insurance of Labour shall be done and cost of same shall deem to be incuded in quoted rates.
All as per item No 5 here in before but tank of capacity 25000 gallon to 50000 gallons
Supply & fix in replacement Ductile iron pipe spigot and socketed class K-7 ISI marked with internal cement mortar lining and external zinc and bitumen coated pipes 200 mm bore confirming to IS 8329 : 2000 with all required DI fittings complete with push on rubber gasket joint. ,complete all as specified and directed.(Note : Earth work will be measured and paid separately.
All as per item No 7 here in before but 150mm bore
All as per item No 7 here in before but 100mm bore
Supply and fixing in replacement of GI steel tubing 80mm bore including replacement of US fittings like Tee, bend, nipple, union, plug and socket etc. laid in trench/wall/floor including necessary saddles and clamps ,complete all as specified and directed.
All as per item No 10 here in before but 50mm bore
All as per item No 10 here in before but 40mm bore
All as per item No 10 here in before but 25 mm bore
All as per item No 10 here in before but 20 mm bore
Supply & fix in replacement Cast iron sluice valve, ISI Marked 200 mm bore flanged of class 1.6 PN having spindle made out of gun metal, operating wheel nuts, bolts, packing complete all as specified and directed.
All as per item No 15 here in before but 150mm bore
All as per item No 15 here in before but 100mm bore
All as per item No 15 here in before but 80mm bore
M&L in replacement Air release valve of size 100mm bore with two air outlet conforming to IS 14845 and fixing up dectile Iron pipe ,complete all as specified and directed.
M & L in replacement CI non return valve of bore 150 mm dia ,ISI marked all as specified and dircted
M & L in replacement CI non return valve of bore 100 mm dia ,ISI marked all as specified and dircted
M&L in replacement Gun metal globe/gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 50mm bore dia steel tubing complete all as specefied.
All as per item No 22 here in before but 40mm bore
All as per item No 22 here in before but 25mm bore
All as per item No 22 here in before but 20 mm bore
Material and labour in replacement Run lead joint complete with spun yarn packing & filling properly of 200 mm dia/bore pipe , complete all as specified
All as per item No 26 here in before but 150mm bore
All as per item No 26 here in before but 100 mm bore
Material & labour for repair, Brick mesonry valve pit of size 120x120x120cm (internal size) with mild steel cover 6mm thick and angle iron frame of size 50x50mmx6mm duly painted with two coats of synthetic enameled paint over a red oxide primer including locking arrangement , brick work and all inner surfaces of pit and exposed portion of out side shall be plastered in cement motor (1:4) complete all as specified and directed.
All as per item No 29 here in before but Brick masonry valve pit of size 75x75x60cm.
M & L for painting with approved colour to existing MS/GI pipe (raising main delavery over flow and wash out) of size 150mm dia 30 mtr height over head tank with two coat of synthetic enamelled paint including scrapping out old paint all as directed. Note:- All T & P, 30 mtr staging mtrl and men power risk contractor respinsibility.
All as per Item No. 31 here in before but dia pipe 80/100 mm
Material & Labour in replacement cast iron fittings for flanged or spigot socketed pipe such as tail piece connecting pieces bends tappers, tee pieces (Single or double branch) any type & angle/radious and straight connecting pieces suitable for bore upto 200mm dia pipe complete all as specified and directed.
Earthing complete with galvanized GI earth plate electrode of size 600 x 600 x 6.00 mm ,buried directly in ground (earth pit not less than2.25 m below normal ground level)with top edge of earth Strip not less than 1.5 mtr below normal ground level, connected to galvanized earth strip 25 x 4mm by means of bolts ,nuts ,check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate no 3 of SSR part-I, 20 mm dia watering pipe medium grade 1.70 mtr long, GI protection pipe light grade 40 mm dia from earth pit to main board ( Note :-(I)maximum length of GI protection pipe with each earth shall not exceed 7.5 mtrs ) including necessary pit with cover.
M &L in replacement LED tube light fittng with tube LED tube rod of 20 watt 240 V ,complete all as specified and directed.
Supply and fixing in replacement LED street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,sturdinessexcellent corrosion resistant IP 66,Operating Voltage 140-270 Volts, PF (0.95)of luminaires 40 watt LED 5700K complete fitting.
Supply and fixing street light mounting bracket made out of GI pipe 40 mm dia medium Grade not less than with 1.5 m.long in any shape and painting with aluminium paint,all as direced by Engr in Charge
Supply and fixing in replacement 1100 volts grade heavy duty cabel PVC insulated copper conductor single core cable size 1.5 Sqmm complete all as specified and directed
Material & labour taking out CI/MS/DI pipe flanged type 150mm / 100 mm dia of rising main/delevery/over flow/wash out of OHT of height 30mtr cleaning and refixing with replacing nut bolts, rubber gas kit /gland packing etc.
Supply only Calcium based granual dis infectant for water treatement more stable than chlorine gas and stronger than bleaching powder and Calcium Hypo chlorite 65% to 70% Chlorine content in granular. (Packing in 45 Kg Plastic drum) all as specified and directed by Engr-in- Charge.
Material & labour in replacement for chlorine test kit with coloured ample complete with all testing fitments and OT solution in box.
Supply only OT soluation for chlorine test 500 ML bottle
Supply and fixing in replacement ML-4 power contractor 415 V
Supply and fixing in replacement 3 Pole power contactor type MNX 45
Supply and fixing in replacement 3 Pole power contactor type MNX 70
Supply and fixing in replacement 3 Pole power contactor type MNX 95
Supply and fixing in replacement single phase preventor SCP 4 type.
Supply and fixing in replacement Relay range 30 Amp to 50 Amp MN-5.
Supply and fixing in replacement Relay range 45 Amp to 90 Amp MN-5.
Supply and fixing in replacement Star delta Timmer ET 100 to 30 sec 240 volt.
Supply and fixing in replacement Add on auxiliary contact block type MNX 9 1NO + 1NC
Supply and fixing in replacement copper thimble 16/25 sqmm
Supply and fixing in replacement Digital Ampere meter.
Supply and fixing in replacement Digital Voltmeter.
Supply and fix in replacement Push Button Red & Green for On and Off.
Supply and fix in replacement 3 Phase indicater R,Y, B of Make : L & T /GE - 01 set of three
Testing of water from Govt Approved labrotory and submit the report for Chemical/Bio logical testing.
Supply only anti vegetation chemical liquid of 1ltrs bottle complete all as specified and directed.
Supply and fix in replacement MCB 40 Amp TPN,415 Volts, 10 KA complete all as specified and directed..
Supply and fix in repalcemnet of MCCB 100 Amp, 3 pole, 415 volt,16 KA complete all as specified and directed.
All as per item No 60 here in before but capacity 125 Amp, 3 pole, 415 volt, 25 KA complete all as specified and directed.
All as per item No 60 here in before but capacity 200 Amp, 3 pole, 415 volt, 36 KA complete all as specified and directed.
All as per item No 60 here in before but capacity 250 Amp, 3 pole, 415 volt, 36 KA complete all as specified and directed.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 50 sq. mm 3.5 core
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m deep and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling and well ramming in layers not exceeding 25cm thick complete all as specified.
Removal of surplus soil to a distance not exceeding 50 metre away and depositing where directed at a level not exc 1.5m above the starting point ,complete all as specified and directed.
Material & labour for cleaning away all grass vegetation, scapling shrubs bushes under groth roots and trees upto zero level not exceding 30 cm grith and removing rubbish upto distance of 50 mtr out the periphery of area under cleaness complete with tractor/JCB plants all as specified and directed.
M/s Vijay Construction Co.
CHINAR ENGINEERS AND BUULDERS
M/S MAHAJAN CONSTRUCTION CO
HARPAL ENGINEERS AND BUILDERS
Bharat Builder
Santokh Singh and Associates
BHARAT ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .