Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 CrAccepted-AOC | ₹32.2 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹37.3 CrRejected-Finance MONEY TENDER FEES AND TENDER DOCUMENTS SUBMITTED ON 19 06 2021 19 06 2021 TECH BID OPENING 16 07 2021 PRICE BID OPENING 3 CORRIGENDUM I DATED 12 06 2021 4 CORRIGENDUM II DATED 15 06 2021 5 CORRIGENDUM III DATED 16 07 2021 | ₹37.3 Cr | L2 | Rejected-Finance Not qualified for financial |
| 3 | Not Admitted-Fee/PreQual/Technical CIVIL WORKS FOR CONSTRUCTION OF ADDITIONAL OFFICE BLOCK AT IOCL PUNJAB STATE OFFICE BUILDING PLOT NO 3A SECTOR 19 A CHANDIGARH UT | NA | NA | 160001 | - | - | Not Admitted-Fee/PreQual/Technical Others-Not to be considered as EMD Not deposited |
| 4 | Not Admitted-Finance 519 P SECTOR 3 URBAN ESTATE KURUKSHETRA 136118 | KURUKSHETRA | KURUKSHETRA | HARYANA | 136118 | - | - | Not Admitted-Finance Others-Due to higher rate |
Tender Value
₹32.6 Cr
EMD Value
₹65.2 L
Closing Date
23 Feb 2022, 5:00 pmClosed
XEN PR Sirsa
XEN PR Sirsa
Const. of Zila Parishad Office Building, Sirsa
2022_HRY_207695_1
Const. of Zila Parishad Office Building, Sirsa
Open Tender
Civil Works
120 days
District Sirsa
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹65.2 L
Yes
5 Jul 2022
11 Feb 2022
24 Feb 2022
11 Feb 2022
23 Feb 2022
11 Feb 2022
Amount
NS Itmes
Providing & fixing Stainless Steel Fittings (Chrome Finished) to doors,window,cupboard etc. (Grade 304) with nuts & screws etc complete.(as per sample approved by Engineer-in-charge) S.S tower bolt (200 mm long)
S.S tower bolt (150mm long)
S.S sliding bolt (250 mm long)
S.S REAR MAGNETIC DOOR STOPER.
150 mm floor S.S front Door stoppers (Godrej or equivalent make) with rubber cushion screws etc to suit shutter thickness complete.
Providing and Fixing 450 mm long, 32 mm thick H type Stainless steel door handle for frame less doors (Ozone make or equivalent)
Providing & Fixing Patch lock for frameless doors (Ozone make or equivalent)
Providing and fixing of 6 mm thick HPL (High Pressure Laminate) sheet cladding in horizontal or verticle direction on the building facade. The facade tiles shall be rigid and of adequate strength and shall satisfy all the performance parameters. The HPL sheet Cladding shall be fixed to an extruded aluminium support framework consisting of vertical aluminium tubular sections measuring 40x40mm spaced at maximum 1000mm c/c intervals, fixed to the wall using aluminium L-brackets spaced at maximum 1200mm distance vertically. (Aluminium frame will be payable separately)
Supply of Wooden fire cum accoustic doors as per BS:476 Part- 20 & 22 & IS 3614 part-1 & part-2 for stability, integrity and thermal insulation. 03 Criteria Wooden door confirming to IS 277 with the following specification. Recommended 52mm thick fire door shall have doors tested at CBRI vide test report no. FR/0378 Dt: 22-06-2018 for maximum rating of 2hrs without acoustic properties, as there is no arrangement to measure the acoustic properties at CBRI, Roorkee. Any deviation in specification other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door leaf shall be 77mm thick fully flush door with or without vision lite. 77mm thick shutter, comprising of 100mm x 69mm hardwood internal timber frame work, with infill of 45mm thick fire resistant & accoustic wool insulation of 48 Kg/m3 density coated with VIPER FR coating on both sides for insulation. The coated insulation shall be sandwiched between 12mm thick HILUX / PAMTECH Non Combustible (Calcium Silicate) Board on both sides (edge to edge on internal Hard wood frame and cladded with 6mm thick commercial ply and 1mm thick Laminate (Any Regular Plain Shade In Suede Finish) on both sides, with 77mm x 10mm exposed Hardwood beading, 20 x4mm fire & smoke intumescent seal shall be used for shutter & for the frame 01 Nos. X 20 x 4mm fire and smoke intumescent seal (For Smoke Sealing). The Frame shall be 140 x 90mm of Hardwood (Red Mirandi) and coated with VIPER Fire reatrdent Primer. The frame shall be installed in civil opening with the help of HRD fastener of size M10 dia of FISCHER Make. The rebate shall be of 20mm x 80mm in Door Frame to accommodate the shutter in frame The board shall be Resistant to vermin, mould growth, minor impact, abrasion and short term water attack and shall be Off –white in colour with a smooth surface suitable to receive most forms of decoration. The prices should be incluisve of SS Ball Bearing Hinges 100x89x3mm Of Becker F.S.,Overhead Door Closer TS-2000v Of GEZE, Mortise Dead Lock Of Becker F.S., SS H Type Pull Handle Of KICH / Becker F.S., SS Exposed Tower Bolt 450mm of DORSET. The door woulde fitted with accoutic seal set of RAVEN Make (RP8Si, RP16Si, RP-120) & will be having 11mm thick 120 min. fire rated interlayered glass vision panel of size 300x350mm of CONTRAFLAME DOORLITE of SAINTGOBAIN Make. 120 MIN. FIRE RATING WOODEN FIRE CUM ACCOUSTIC DOOR (30-32 db)
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 200mm gap
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.) Wall Joint of 200mm gap
Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) Roof Joint of 200mm gap
Supplying, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required. Horizontical type, end suction, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq. cm. at highest and farthest outlet at specified flow of 2280 Lpm at 70 Mtrs. head confirming to IS 1520-1980 Suitable HP SQ cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection (min.) for enclosure, horizontical foot mounted type with Class-'F' insulation, confirming to IS-325-1978 M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with antil vibration pads.
Supplying, Installation, Testing and Commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required. Horizontal type, endsuction, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and fathest outlet at specified flow of 2280 lpm at 70 mtrs.. head confirming to IS 1520-1980. Suitable HP, 1500 RPM water cooled with radiator, diesel engine confirming to relevant BS & IS standard complete with auto starting mechanism, 12 Volts electric starting equipment, Diesel Tank exhaust pipe extended upto 1 mtr. outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer,low lubricant oilo pressure switch, lubricant oil pressure gauge with necessary pipe work, Techo hour meter, radiator water temperature guage solenoid for auto stop in the event of high/low lubricant oil pressure, high cooling water temperature with audio visual indication, painted with post office red colour etc. as required. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
Supplying, Installation, Testing and Commissioning of electric driven (Jockey) pressurization pump suitable for auto operation and consisting of following: complete in all respect as required. Horizontical type, end suction, centrifugal pump of cast iron body and bronze impleller with stainless steel shaft, mechanical seal and flow of 180 lpm at 70 mtr. head confirming to ISI: 1520-1980 Suitable HP SQ cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55(min.) class of protection for enclosure, horizontal foot mounted type with Class 'F' insulation, confirming to IS: 325-1978. M.S. Fabricated Common base plate, suitable channel, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
Supplying and Laying of ISI marked XLPE insulated, PVC sheathed alluminium armoured conductor 1.1 KV grade armoured Cable of following sizes clamped as required. A 3 x 120 sq. mm
B 3 x 25 sq. mm
Supplying and Laying of ISI marked copper XLPE insulated, PVC sheathed un- armoured conductor Cable of following sizes clamped as required. A 2 x 2.5 Sq. mm
B 3 x 4 Sq.mm
C 6 x 2.5 Sq. mm
Supplying and making termination with brass compression gland & Al. lugs for following sizes of PVC insulated, PVC sheathed XLPE Al. conductor cables of 1.1KV grade as required. A 3 x 120 sq. m.m.
B 3 x 25 sq. m.m.
Providing and fixing 6 SWG dia G.I. Wire on surface or in recess for loop earthing complete as required.
Fabricated and installation of perforated MS cable tray including horizontal and vertical bends, reducers, tees, cross members and other accessories as required duly suspended from the ceiling with MS Suspenders and including painting. A 150 mm width X 50 mm depth X 1.6 mm thickness
b 300 mm width X 50 mm depth X 1.6 mm thickness
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode as req.
Providing and fixing 25mm x 5 mm GI strip on surface or existing cable tray etc.
Supplying and installation of Pressure Switches for auto operation of Pumps
Providing laying, testing, & commissioning of 'C' class heavy duty MS Pipe confirming to IS 1239/3589i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (External Work) 200 mm diameter
B 150 mm diameter
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe confirming to IS 3589 and 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Vertical & Ceiling Pipe) A 250 mm dia (8 mm thick)
B 200 mm dia (6 mm thick)
C 50 mm dia
D 100 mm dia
E 80 mm dia
F 65 mm dia
G 50 mm dia
H 40 mm dia
I 32 mm dia
J 25 mm dia
Supplying and fixing single headed internal/external hydrant valve with instantaneous stainless steel couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank S.S cap and chain as required. A Internal Hydrant
External Hydrant
Supplying and fixing, testing and commissioning of butterfly valve PN 1.6,CI body ductile (SG) iron Disc with Nylone Coated,SS-410 Stem, EDPM INTEGRALLY Moulded Liner duly ISI marked complete with Nuts, Bolts, washer, gaskets, confirming to IS 13095, of following sizes as required. a 250 mm dia
150 mm dia
100 mm dia
80 mm dia
65mm dia
50mm dia
Providing, installation, testing and commissioning of dual plate non-return wafer type check valve of with Bronze/GM seat following sizes confirming to IS: 5312 complete with rubber gasket, GI nuts, washers etc. as required. A 250 mm dia (b) 150 mm dia
80 mm dia
65 mm dia
Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office Red, confirming to IS 884 with upto date amendments, complete with the following as required. a 40 m. long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type -2 as per IS:12585 b 20 mm (nominal internal) dia stainless steel globe valve & nozzle. c Drum and brackets for fixing the equipments on wall. d Connection from riser with 40mm dia stop valve (GM) & MS pipes
Supplying & Fixing 63 mm dia stainless steel branch pipe with 20 mm (nominal internal diameter) size stainless steel nozzle conforming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
Supplying & fixing four way fire brigade connection of cast iron body with 4 Nos. Gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for 150 mm dia MS pipe connection, conforming to IS 904 as required.
Supplying & fixing of Gunmetal Fire Brigade Suction Hose coupling (Draw out connection) with Nut for female coupling as per IS:902-1974 complete with 100mm dia G.I. Suction pipe and 100mm dia foot valve (to be connected to Static Tank).
Providing and fixing Air vessel 450 mm dia 8mm thick MS sheet 1800mm in height with air release valve on top & flanged connection to riser, drain arrangement with 25mm dia gunmetal wheel valves and the legs shall be provided MS plate size 75x75x5 mm at the bottom and grouted in CC foundation. with required accessories, pressure gauge & painting with synthetic enamel paint of approved shade as required.
Providing fixing air Vessel of 250mm dia 8mm thick MS sheet 1200 in height with air release valve on top & flanged connection to riser, drain arrangement with 25mm dia gunmetal wheel valve and the legs shall be provided at the bottom and grouted in CC foudation with required accessories, pressure gauge & painting with synthetic enamel paint of approved shade as required
Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg): With F.P.S. bricks with class designation 75
Providing and fixing electrically operated flow indicating switches system sensor in sprinkler branch line on each zone with necessary junction box installed in accessible place. (Wiring from switches to panel and stair case pressurization not included). a 150mm dia
Providing and fixing testing and commissioning of installation control valve of cast iron body and brass/ bronze working parts comprising of water motor alarm, bronze seat clapper and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/ sprinkler system activates pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate gasket etc of size 150 mm dia as required. a 100mm dia
Providing and fixing dial type pressure gauge with isolation cock and pipe at hydrant station & sprinkler line. Dia 100 mm calibration 0-15 Kg.
Providing fixing testing & commissioning of 15 mm size quartzite bulb type sprinklers, of rating 68 degree C with required accessories. A Pendant type
Horizontal side wall sprinkler
Upright
Providing and fixing, testing and commissioning of 20 mm dia. SS flexible pipe with crome plated rozzet plate. A 1000mm long
Providing & fixing of hose cabinet of sizes 750 mm x 600 mm x 250 mm made of 2 mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos 15 mtr long hose pipe 1 no branch pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respective of external hydrant as required.
Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, enamelled fire red finish with 'FHC' written in front.The width and height to depend upon the actual size of the fire shaft available and get it approced by Engineer-in Charge/ consultant before fabrication Approximate size 1800x1200 mm.
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
S/F Fire man axe as rqd.
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. a) 250 mm dia
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 4 Kg. Complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming to IS: 115683.
Providing and fixing portable fire extinguisher carbon dioxide type with cylinder initially fully charged with CO2 gas of 4.5 Kg. Capacity, complete with discharge valve, dishcarge tube, horn, CI bracket for wall mounting etc. conforming to IS: 15683.
Supplying, installing, testing and commissioning of Stainless Steel Perforated Screen (Grade SS-304) suitable for handling Raw Domestic Sewage
Supplying, installing, testing and commissioning of raw sewage lift pumps as per following details: The pump set unit shall be complete with : a) Pumps: Non-clog fully floodable submersible pump suitable to handle raw sewage Material of Construction (M.O.C): Corrosion Resistant in general Shaft — SS Impeller — CI Motor: Housing — Stainless Steel RPM — 2900 Insulation Class — F Protection Degree — IP68 Suspension System Duty: Discharge : 2.5 M3/hr. (Minimum) Head : 12M
Supplying, installing, testing and commissioning of filter feed pump as per the following details : The filter feed pump unit shall be complete with : a) Pumps: Vertical /Horizontal monoblock with mechanical seal Material of Construction (M.O.C): Corrosion Resistant in general Pump Casing—Cast Iron/Stainless Steel Impeller — CI Shaft — Stainless Steel Duty: Discharge ( each pump) : 5 M3/hr. Head : 30M
Supplying, installing, testing and commissioning of twin lobe air blowers of approved Make Details of Equipment offered (To be filled in by the tenderer) Air Blower Make: Model: Discharge : 50 M3/hr. at 5000 mmWC
Supplying, installing, testing and commissioning of FAB Reactor . It shall include media for bacterial growth, air diffusers (including for Equalization and sludge holding tanks), and all other equipment, media etc. required in the reactor unit. Details of Media and Equipment offered (To be filled in by the tenderer) Type of Reactor: No. of Reactor: Type of Media: Volume of Media/ Reactor (M3): Vol. of MS Tanks Required (each) M3: Kg BOD Removed/ M3 Media: Make:
Supply, installation, testing & commissioning of non clogging type Sludge recirculation pumps CI material complete with mechanical seal & all accessories, motor of required capacity.Suction header with Isolation Butterly valves, Delivery header with isolation Butterly valve,NRV's. Pumps shall have following duty. Sludge recirculation pump Flow Rate (each) = 2.0 m3 / hr Head = 8-10Mtr Solid handling = 8mm Make: Wilo/ Grundfos/Kirlosker Motor HP = As per manufacturer recommendation
Providing, installing, testing and commissioning vertical down flow type multi grade sand bed pressure filter capable of filtering 5 cum/hour of water at prescribed filteration rate of 15 cum/sq.m/hr. The filter shall comprise of Composite FRP PP lined shell, suitable for a test pressure of 6 kg/sq.cm. , complete with pedestal, access cover, PVC underbed, 50 mm dia frontal piping, pressure guage, first charge of filter media. etc. Details of Filter Filter Shell MOC : Fibre glass and polyester resin Dia : 650 MM (Min.) Details of Filter offered (to be filled in by the tenderer) Make : Model : Dia : MM (Min.) Height : MM (Min.) Test Pressure : Kg/cm2 (Min.) Media Bed Depth : MM ( Min.) Multiport Valve : inch
Providing, installing, testing and commissioning vertical down flow activated carbon filter capable of filtering 5 cum/hour of water at prescribed filteration rate of 15 cum/sq.m/hr. The filter shall comprise of Composite FRP PP lined shell, suitable for a test pressure of 6 kg/sq.cm. , complete with pedestal, access cover, PVC underbed, 50 mm dia frontal piping, pressure guage, first charge of filter media. etc. Make : Astral or equal approved. Details of Filter Filter Shell MOC : Fibre glass and polyester resin Dia : 650 MM (Min.) Details of Filter offered (to be filled in by the tenderer) Make : Model : Dia : MM (Min.) Height : MM (Min.) Test Pressure : Kg/cm2 (Min.) Media Bed Depth : MM ( Min.) Multiport Valve : inch
Providing, installing, testing and commissioning chemical doser comprising 100 litres capacity HDPE tank, electronic metering pump of 0 - 6 litres/hr. capacity injection fitting, solution delivery tube etc. including making electrical connection for auto operation, all complete.
Providing, installing, testing and commissioning of Sludge Filter Press of following rating, all complete including making electrical and drain connections etc. Cake Holding Volume: 120 Litres Size: 450 mm X 450 MM with 17 nos. plates MOC: CI/ MS frame with Poly Proplene (PP) plates Sludge Feed Pumps: a) Type : Screw Type b) Nos : 2 Nos.(1 Working + 1 Standby) c) Duty : 2 Cum/Hr at 35 M Head Details of Equipment offered (To be filled in by the tenderer)
Providing, installing, testing and commissioning UV Disinfection System for the complete disinfection of the final effluent of the following make or equal approved. a) Flow : 5M3/Hr Make: Alfa UV
Providing, fixing, jointing, testing and commisioning interconnecting pipe work, sleeves, valves, Rotameters to control the flow, pressure gauges with isolating cocks etc.
Providing, fixing, connecting, testing and commisioning of Pump Control Panel.
Providing, fixing,connecting, testing and commisioning power and control cabling between pump panel, pumps, level controllers, solenoid valves etc.
Providing, fixing, testing and commissioningof Electro Magnetic Flow Transmeter with Communication Port, of approved makes. Suitability: Sewage Effluent MOC: Body : Non-corrosive Lining : PTFE Flanges : Stainless Steel Electrode : Stainless Steel Coil Housing : Stainless Steel Pressure Rating : Minimum 10 Bar Temerature Withstanding : upto 850 C a) 50 mm dia
Providing factory fabricated/ fabricated at site MS vessels for reactor-2nos, settler, sludge holding tank and chlorine contact tank, complete wirth all accessories, overflow channels, support structures, ladders, inspection platforms etc.all complete including installation at site. Note: The material of construction shall be non corrosive and the Vendor shall submit a note mentioning the material , proposed anti corrisive treatment and method of fabrication.
ULTRA FILTERATION (UF) BASED POLISHING SYSTEM Providing, installing, testing and commissioning of Ultra Filteration (UF) system for further polishing treated effluent and capable of producing 5,000 litre / hour of polished water meeting the requirements given in Section-B & D of Scope of Work. The system shall be complete with UF Feed Pumps (1W+1S), CIP Pumps (1W+1S), Backwash Pumps (1W+1S), Cartridge Filters, UF Membranes Flushing / Cleaning System, complete instrumentation for automation and monitoring, Rotameters, Pressure Gauges, interconnecting pipework, electrical cabling and switchgear, all complete as described in Scope of Work enclosed herewith.
SITC of 18W LED Surface mounted round/square type downlighter. The Fixture should be Made of Extruded Aluminium Housing. Inbuilt Protection of 2kv, PF>.95, System Wattage 18W integral housing for driver. Minium 100 lumens/W in 5700k. The Fixture should be of Makes BAJAJ(BGSLO-SLEEK-18W RD)/ PHILIPS-SM200C LED15S 4000 PSU OD WH/ CGL: LCDSPL-S-18-/TISVA
SITC of LED Surface Mounted Square/Rect. Bulkhead Light. The Fixture should be Made of PDC Housing.PF>.95, System Wattage 10w with Minium 100 lumens/W in 5700k. The Fixture should be IP-65of Makes :-PHILIPS(WT202WLED6SNWPSUS2PC)/ BAJAJ(112334-BIBWP 10W LED) /TISVA
SITC Surface Mounted Bracket/wall light . The Fixture should be Made of chrome&metal Housing.PF>.95, System Wattage Tronto E27,24Ww with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS: 45617/17 Vasa(915004400401)/TISVA
SITC 45W LED Street Light. The Fixture should be Made of pressure diecast housing with TOUGHNED GLASS diffuser and indivisual LEDs with secondary optics with IP 66 protection. PF>.95, System Wattage LED 45W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-BAJAJ EDGE (169799 BRTFG 45W LED) /PHILIPS BRP409 LED 040 CW HO MR FG S1 PSU GR/CGL LSTP-45 CDL /GE/OSRAM/WIPRO/Havells( 12 for poles)
SITC 1x18W or 18/20W LED 1200mm Batten Light. The Endura Fixture is a surface & wall mounted LED batten with extruded aluminium housing and robust construction . PF>.95, System Wattage LED 20W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS(BN108C LED 20S PSU CDL WH)/BAJAJ(169846 BLTRU20W WH VIVA ) /TISVA
SITC 6W LED aesthetically brillient surface picture/mirror light. The Fixture comprises of aluminium with silver/gold finish . PF>.95, System Wattage LED 6W with Minium 1500 lumens in 5700k of size 70x87x350mm. The Fixture should be of Makes :-PHILIPS(Code 919215850143)/BAJAJ /TISVA
Supply of Surface/recessed type 32W Full window glarefree opal Diffuser LED Panel of size 600X600mm suitable for Surface with MS Powder coated White Housing. Total system Lumen of 36W LED should be 4100 or above in Cool day Light(5600K to 6500K), Power factor>0.90, CRI (Ra) >80, THD <20% LED Lamp. Efficacy>140 Lm/W. Complete with all accessories as required with connections Make- Havells(Rs3285), Phillips(Rs6000) , Bajaj(Rs6300). TISVA
SITC 2x18W or 36/40W LED 1200mm Batten Light. The Endura Fixture is a surface & wall mounted LED batten with extruded aluminium housing and robust construction . PF>.95, System Wattage LED 40W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS(BN108C LED 40S PSU CDL WH)/BAJAJ(169846 BLTRU 40W WH VIVA ) /TISVA
Supply, erection, testing and commissionoing of 10 KVA UPS system complete with battery bank (30/60 minutes backup) SMF battery 12 V 65 AH/12V100AH = 16 Nos. complete with all accessories including battery breaker, racks, links, cabling including all petty material required to complete the job upto entire satisfaction of the Engineer-in-charge. Make: FUJI,NUMARIC,SOCOMEC.
Supply, erection, testing and commissionoing of 20 KVA UPS system complete with battery bank (30/60 minutes backup) SMF battery 12 V 65 AH/12V100AH = 16 Nos. complete with all accessories including battery breaker, racks, links, cabling including all petty material required to complete the job upto entire satisfaction of the Engineer-in-charge. Make: FUJI,NUMARIC,SOCOMEC.
SUPPLY OF PVC/XLPE INSULATED ARMOURED CABLES Supply of aluminium onductor PVC/XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988. Make Havells,Polycab,Finolex,KEI i) Overall size 35sq.mm (3½ Core) Armoured( Incoming to 2 UPS+ Incomig to Lift+ Incoming to Water pump panel+incoming to fire pump panel+Incoming to Goods lift+ Incomig to Lighting,Power & Raw Power DB's=50x24=1200
Overall size70sq.mm (3½ Core) Armoured ( For HVAC VRV System 6x50=300mtr)
Overall size 120sq.mm (3½ Core) Armoured (For Misc Temp Supply)
Overall size 150sq.mm (3½ Core) Armoured( DG Incoming 100mtr+Spare Length100=200mtr)
Overall size 300sq.mm (3½ Core) Armoured( Incoming from CSS 100mtr+Spare Length100=200mtr)
Overall size 16sq.mm (4Core) Armoured( St Light 12x70=600)
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.(DSR 1.19 Based)
24 Port POE Rack Mountable, Gigabit Switch with 4 SFP Port etc. as reqd. D-Link DGS-1210-28 P 10/100/1000Mbps Unmanaged Ethernet Switch with 1 year Warrenty (For Data points distribution)
RACEWAYS (i) SITC of Metal/GI Raceways having 2.44 mtr standered length size 225x38x 3 compartments 1.6mm thick. Legrand code 6895-04
SITC of Metal/GI Raceways having 2.44 mtr standered length size 100x38x 1 compartments 1.6mm thick. Legrand code 6895-02
SITC of Metal/GI Raceways having 2.44 mtr standered length size 50x38x 1 compartments 1.6mm thick . Legrand code 6895-00
SITC of Fixing brackets for 225x38mm 3 compartment 1.6mm thick raceways Legrand Code 6897-25
SITC of Fixing brackets for 100x38mm 1 compartment 1.6mm thick raceways Legrand Code 6897-37
SITC of Fixing brackets for 50x38mm 1 compartment 1.6mm thick raceways Legrand Code 6897-27
SITC of Vertical Riser for 225mm width raceways Legrand Code-6897-23
SITC of coupler for joining raceways Legrand Code- 6897-77
SITC of Height Adjustable Junction Box with lid size 225x225x60-90mm Legrand Code 6896-11
Supply Installation Testing & Commissioning of Bullet Camera 1/3” 4MP Progressive scan CMOS . Min. Illumination [email protected]. Effective Pixels 2688(H) x1520(V). Angle of View • Horizontal: 104°–27° , Vertical: 55°–15°, Diagonal: 124°–31°. Shutter Speed Auto/Manual, 1/3~1/100000s. Lens 2.7mm~13.5mm Motorized. Gain Control(AGC) Auto/Manual. Video Compression H.265+/H.265/H.264+/H.264. S/N Ratio More than 50dB or better. Streaming Capability Triple Streaming, (2560 × 1440@25 fps); (704 × 576@25 fps); (704 × 480@30 fps). Privacy Masking Upto 4 Areas. Smart Analytics Tripwire, Intrusion. Motion Detection Off / On (4 Zone, Rectangle). ICR Switch. Digital Zoom 16x. Audio Input/ Output 1 IN /1 OUT. Audio Compression G.711A/G.711Mu/G.726/AAC . Alarm IN/Output 1 IN/1 OUT. Wide Dynamic Range Upto 120dB or better. Ethernet RJ-45 (10/100M Base-T). IR Range of 60 Mtr. Micro SD Card (support max. 256 GB); NFS. Weather Proof Rating IP67. Certificates CE,FCC, UL, BIS. Make: MOBITECH/AXIS/PALCO
Supply Installation Testing & Commissioning of Dome Camera 1/3” 4MP Progressive scan CMOS . Min. Illumination [email protected]. Effective Pixels 2688(H) x1520(V). Angle of View • Horizontal: 104°–27° , Vertical: 55°–15°, Diagonal: 124°–31°. Shutter Speed Auto/Manual, 1/3~1/100000s. Lens 2.7mm~13.5mm Motorized. Gain Control(AGC) Auto/Manual. Video Compression H.265+/H.265/H.264+/H.264. S/N Ratio More than 50dB or better. Streaming Capability Triple Streaming, (2560 × 1440@25 fps); (704 × 576@25 fps); (704 × 480@30 fps). Privacy Masking Upto 4 Areas. Smart Analytics Tripwire, Intrusion. Motion Detection Off / On (4 Zone, Rectangle). ICR Switch. Digital Zoom 16x. Audio Input/ Output 1 IN /1 OUT. Audio Compression G.711A/G. 711Mu/G.726/AAC. Alarm IN/Output 1 IN/1 OUT. Wide Dynamic Range Upto 120dB or better. Ethernet RJ-45 (10/100M Base- T). IR Range of 60 Mtr. Micro SD Card (support max. 256 GB); NFS. Weather Proof Rating IP67 IK10. Certificates CE,FCC, UL, BIS. Make MOBITECH/AXIS/PALCO
Supply Installation Testing & Commissioning of Network Video Recorder with 12 TB HD Quad-core processor. Operating System Embedded LINUX. IP Camera Input 32 channel. Video Output 1 HDMI, 1 VGA. Compression H.265+/H.264+ dual codec decoding. Video Resolution 3840× 2160, 1920× 1080, 1280× 1024, 1280× 720, 1024× 768. Max 640Mbps (Incoming + Outcoming) ,Up to 12MP resolution preview and playback. Motion Detection MD Zones: 396(22×18).Hard Disk 2 SATA III ports, up to 10TB Each. Alarm Input 4 Channel, Low Level Effective, Green Terminal Interface. Alarm Output 2 Channel, NO/NC Programmable, Green Terminal Interface. Smart Phone iPhone, iPad, Android Phone. Trigger Events Recording, PTZ, Tour, Video Push, Snapshot, and Screen Tips. Recording Mode Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Tampering, Video Loss), Stop. Search Mode • Time/Date, MD & Exact search (accurate to second),Smart Search.Backup Mode USB Device/Network. Interface Ports • 1 HDMI, 1 VGA, 2 USB(1 Rear USB3.0,1 Front USB2.0), 1 RS485, 1 RS232. Ethernet 1 RJ-45 port (10/100M/1000M). Make MOBITECH/AXIS/PALCO
Supply Installation Testing & Commissioning of Layer -2 24 Port Gigabit PoE 10/100/1000Mbps Switch. port1-port 8 can support 250m supply power. PoE Power Budget 250W. LED light 26 Link/Act Indicator light, 16 PoE indicator light, 1 Power indicator light. PoE Standard IEEE 802.3i IEEE 802.3u IEEE 802.3x IEEE 802.3ab IEEE 802.3af IEEE 802.3at. Prioritize the identified video data to make video transmission smoother. Automatic detection power of port, power off and restart the device. Make Cisco/zyxel/Ericsson.
Supply Installation Testing & Commissioning of 6U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit Make: Comrack/HCL/Valrack.
Supply Installation Testing & Commissioning of 12U Equipment Rack . Make: Comrack/HCL/Valrack.
Supply Installation Testing & Commissioning of 43" LED Monitor, HDMI Port.Resolution,1920 x 1080 (FHD),Backlight Type-LED(Edge),Viewing Angle Degree-178x178,Life span (hrs)-30,000,Brightness (cd/m2)-200,or better, Make: Sony/Panasonic/Samsung
Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: LEGRAND/POLYCAB/DALTON)
Supply Installation Testing & Commissioning of CAT 6 UTP Cable. Make: LEGRAND/POLYCAB/DALTON)
Supply and erection of PVC pipe25mm dia ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make: BEC, AKG, Kalinga / Diplast.
Supply Installation Testing & Commissioning of 2 KVA UPS Cum Inverter with 1 hr back up: MAKE Luminous/ LIBERT/ Emerson.
SITC of 6W Recessed Ceiling speakers with following features:-Speaker Drive 6", Complete Aluminium grille and Metal baffle, line matching transformer 100/70V line. Variable wattage tappings of 6 / 3 / 1.5, Effective frequency range 110-15kHz (BS6840), SPL@1m/1W=91dB, Peak SPL 97dB complete with necessary mounting hardware & accesories.
SITC of 10W Wall Mount Speaker with Frequency Response 150Hz - 15kHz, with Line Matching transformer 100V. Variable tapping 10W/5W, SPL@1M/1W - 90dB, Peak SPL 98dB. the cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply, Installation,Testing & Commissioning of Digital Voice Evacuation system for 8 Zones. The System shall meet the standards of BS EN54 - 32 & EN 60849. it should be capable for the EVAC, Paging, PA and BGM functions. The Controller shall have SD card option to store the EVAC and Alert Voice Message. The Controller shall have Speaker line supervision and amplifier auto changeover. The Controller shall have following features: Seperate Zone volume control at the front side of panel, Status indications on the Panel for EVAC, Fault, AC,DC ,Fault, ALERT & Fireman mic, Zone capacity up to 96 Zones, 8 programmable Control Input and output, Fireman Microphone with High Priority, THD<1%, Frequency response 80Hz - 20kHz, Up to 1000 Record files, 100V Class-AB Speaker Output. Make: Honeywell/BOSCH/JBL
SITC of Remote Paging microphone with minimum 08 buttons and Busy/Hole Indication. The Microphone Should be suitable for Desktop mounting.
Supply, Installation, testing and comisioning of 480W RMS Dual Channel Power Amplifier with Switch power technology for power electricity saving, Separate PFC Design for highest reliability, Separate Power Supply System. Amplifier shall have Following Features: 240W RMS per Channel, Amplifier Output 100V, Supply input AC 220 +/- 10% - 50/60Hz, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 40Hz - 20kHz, AC & DC Fuse, SNR >89dB.
Supply Installation testing and comisioning of Professional CD/DVD player with USB flash port & 19" Rack mount arrangement.
Supply Installation testing and comisioning of 19-inch Equipment Rack with standardized frame or enclosure for mounting multiple PA controllers, CD player, Amplifiers etc modules. Size 24U.
Supply & Laying of 1.5 sq.mm. multistrand PVC sheathed Two Core Twin Twisted Speaker Cable in Exiting PVC Conduit.
SITC of 2 Loop with Expendable Loops Micro processor based 1 wire fault tolerant loop, required loop networkable type (each loop accessing 199 detectors and 199 modules ) fire alarm/detection control panel having 640 Character Display The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character LCD unit to indicate Fire/Fault Signal with addresses. The Panel Shall be Sheet Steel Painted, sealed to IP30. The panel should have provision to integrate with PA System . The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. and conforming to BS5839 Standards and Duly Approved by EN54/UL.
SITC of Active Repeator panel
SITC of Analogue Addressable type Smoke Detector with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-159, complete with standard base, as required, complying to EN54 and/UL approved
SITC of Analogue Addressable type Heat Detector with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-159, complete with standard base, as required, complying to EN54 and/UL approved
SITC of fault isolator Module with termination preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring etc. as required and Duly Approved by EN54/UL
SITC of Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/UL
SITC of Sounder Cum Strobe complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/UL
SITC of Output control module for Lift, AHU, Pressure fan/Exast fan etc.
SITC of input monitor module for FA panel intigration with fire fighting flow switch.
2Core 1.5 Sqmm Copper Aromerd Cable FRLS including the cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply Installation testing & commissioning of Passenger (1020 Kg, 15 persons.) Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty period to be supplied and installed in accordance with the following technical specifications: Make:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI Reference Quotation:- OTIS (Model:-GeN2-Nova MRL) CAPACITY (kgs) 1020 Kg, 15 persons. SPEED (mps) 1 mps. RISE (m) 9.5 M. STOPS 4 Stops With (all opening on the same side). CONTROLLER TYPE ACD3-MRL. DRIVE VF Regenerative (Closed Loop). POWER SUPPLY 400/415 Volts (3 Phase AC). OPERATION Full collective operation. CAR GROUP One car (simplex) MACHINE PM Gearless (Located above shaft). TRACTION MEDIA Flat Coated. Steel Belt. CAR FINISH "• Rear Mid Panel = Stainless Steel #4(Hairline). • Rear Corner Panels = Stainless Steel #4(Hairline). • Side Panels = Stainless Steel #4(Hairline). • Front Panels = Stainless Steel #4(Hairline). FALSE CEILING TYPE CD-41. FLASE CEILING FINISH Stainless Steel #4(Hairline). VENTILLATION Cross flow fan. HAND RAILS Stainless Steel Mirror Finish. Handrails on all car panels(sideLH,sideRH&Rear). FLOORING Vinyl Tiles. CAR DOOR FINISH Stainless Steel #4(Hairline). LANDING DOORS FINISH Stainless Steel #4(Hairline). HOISTWAY DIMENSIONS AVAILABLE (W x D – mm) 1890 mm W x 2850 mm D. CAR DIMENSIONS (W x D x H - mm) 1100 mm W x 2000 mm D x 2200 mm D. CAR & HOISTWAY DOOR TYPE Central opening (CO) doors. DOOR OPENING (W x H - mm) 800 mm W x 2000 mm H. DOOR OPERATOR DC Door Operator.
S/I/T/C of DIGITAL IP PBX for 6 Trunks 2 Digital and 24 other extension lines expandable upto 128 ports, with caller id, IP connectivity as per approved by EIC with connection complete in all respect. Make Panasonic/Philips/NEC/AVAYA/CISCO/SEIMENS
S/I/T/C of TELEPHONE SET complete in all respect.(if required). (i) Panasonic Key Telephone KX-DT543 With Patch cords
Panasonic basic phone TSC400 With Patch cords
S/I/T/C of MDF Box for telephone distribution system complete with necessary connections in all respect. (i) 20 Pair
Supply Installation , testing and commissioning of Two-Way 4" Coaxial Ceiling Loudspeaker with Frequency Range: 74 Hz - 20 kHz, Power Capacity (low-Z): 60 W Cont. ProgramMax. SPL: 102 dB @ 1m ave., 108 dB peak, Nominal Impedance: 8 ohms (in irect/bypass 8Ω setting), 70V/100V Transformer Taps capable. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of Dual Channel Power Amplfier - 80W / channel with Frequency Response (8Ω, 20Hz - 20kHz) +/- 0.5dB, Insertion Loss (70V & 100V outputs) 1 dB maximum,Input Sensitivity 1.4Vrms for 8-ohms, Rated Power into 4 Ω or 8 Ω;1kHz, ≤ 0.5% THD, Input Impedance 20K ohms/50K ohms. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of Professional boundary layer microphone with Audio frequency bandwidth 50 - 20000 Hz, Equivalent noise level 22 dB-A, Sensitivity 22 mV/Pa, Signal to Noise72 dB-A. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of Wireless Handheld Microphone System, Carrier frequency range 500.1 MHz – 864.9 MHz, Switching bandwidth 30.5 MHz (depending on local regulations), Audio bandwidth 35 to 20,000 Hz, Signal to Noise 120 dB-A, Up to 16 pre-programmed frequencies per group. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of Wireless Presenter Set Microphone System, Carrier frequency range 500.1 MHz – 864.9 MHz, Switching bandwidth 30.5 MHz (depending on local regulations), Audio bandwidth 35 to 20,000 Hz, Signal to Noise 120 dB-A, Up to 16 pre-programmed frequencies per group. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of 12x8 Digital Signal Processor with Digital link and AEC , 12 Analog Inputs (with 48v Phantom Power per Channel), 8 Analog Outputs, 12 Control Inputs and 6 Logic Outputs for GPIO Integration, Maximum Input Level: +20dBu with 0dB input gain,+8dBu with 12dB gain, Digital Input Impedance: 110 ohm (AES/EBU), 75 ohm (S/PDIF), Sample Rate: 48kHz or 96kHz, THD+N: <-140dB, Maximum Analog Output Level: +19dBu, Frequency Response: 20Hz-20KHz (+0.5dB/-1dB), THD: <0.01% 20Hz to 20KHz, +10dBu output, Dynamic Range: 108dB typical, 22Hz-22KHz unweighted. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of 8 Analog input Expander 8 Analog MIC/Line Input, 2 x RJ45 digital audio Bus Port, Phantom power on all Inputs, Configurable gain control at all inputs. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of 4 Module Connection Ports, 1 x HDMI Port with Retractable, 1 x VGA, 1 x LAN Port, 1 x Power Outlet (IN) Module, Cable Pass-Thru Well Module and Spacer Kit,1/2 M Blank Panel. Make:Philips,Panasonic,Sony
Supply Installation , testing and commissioning of Digital Podium in Steel frame with latest i7 CPU/8 GB Ram 500 TB HDD/21" Touch Hydraulic screen/with Podium USB out/In/HDMI /VGA/ desktop Mic in Podium Wireless Mic. Make:Philips,Panasonic,Sony
SITC of HD 1080p video quality at 30 frames-per-second 90° feld of view with mechanical 260° pan and 130° tilt 10x lossless HD zoom CAMERA Smooth motorized pan, tilt and zoom, controlled from remote or console 260°pan, 130° tilt 10x lossless HD zoom 90° Field of View Full HD 1080p 30fps H.264 UVC 1.5 with Scalable Video Coding (SVC) Autofocus 5 camera presets Far-end control (PTZ) of ConferenceCam products ZEISS lens certifcation Kensington security slot LED to confrm video streaming Standard tripod thread REMOTE CONTROL Dockable 8.5m/28-foot range SPEAKERPHONE Full-duplex performance Acoustic echo cancellation Noise reduction technology Ultra-wideband audio Bluetooth and NFC wireless technology LCD for caller ID, call duration an other functional response LEDs for speakerphone streaming, mute, hold, and Bluetooth wireless paring Touch controls for call answer/end, volume and mute, Bluetooth – plus camera PTZ, “home” preset and farend control Microphones (Tx) Four omni-directional microphones supporting 20-foot diameter range Frequency response: 100Hz – 11KHz Sensitivity: -28dB +/-3dB Distortion: <1% @ 1KHz at 106dB Speakers (Rx) Frequency response: 120Hz – 14KHz Sensitivity: 83dBSPL +/-3dB at 1W/1M Max output: 91dBSPL Distortion: <5% from 200Hz Kensington security slot HUB / CABLE Central mountable hub for connection of all components Included adhesive solution for under-table mounting Two cables for connection between hub and camera/speakerphone (Length: 5m/16’) One USB cable for connection to PC/Mac (Length: 3m/6.6’) AC Power adapter (Length: 3m/9.8’) MOUNT Dual purpose mount for wall placement or for elevating the camera on a table. MAKE : LOGITECH/AMX/POLYCOM/SAMSUNG/CISCO/ AVAYA / AT&T
Supply, Installation, Testing & Commissioing of 86" interactive flat panel, IR touch technology, IPS Panel UHD Native Resolution ( 3,840 x 2,160), Brightness 330 Nits; Contrast ratio 1100:1, response time :8ms, CONNECTIVITY (Input) Video / Audio HDMI (3), RGB / Audio In(Input) External Control RS232C In, RJ45 (Input) USB USB 2.0 (3, Front : 2ea, Bottom side: 1ea Only for software update), USB 3.0 (3), Touch Out(USB2.0,B Type) (2)(Output) Video / Audio HDMI (1), Optical Output / Audio Out with OPS i5 system. MAKE : LOGITECH/AMX/POLYCOM/SAMSUNG/CISCO/ AVAYA / AT&T
VRV : 32 HP ODU
VRV : 24 HP ODU
4 Way Cassette Type indoor unit - VRV Supply,installation,testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan /dynamically balanced blower, multispeed motor, coil section with DXCoppercoil electronic expansion valve, outer cabinet, drainpump ,grill, necessary supports, vibration isolation,cordless remote controletc. ,suitable for operation on single phase 230V±10%,50Hz ACsupply, complete, asrequired. The unit shall have automatic for shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CD Band 19 Degree CWB temperature. Make Daikin,Hitachi,Mitsubishi,Carrier (i) 4.0 TR
Hi-Wall Type indoor unit - VRV Supply,installation,testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower,multispeedmotor,coilsection with DX coppercoil, electronic expansion valve,outer cabinet, cordless remote control, drainpan, necessary accessories etc.,suitable for operationon 230V±10%,50Hz, singlephaseACsupply, completeasrequired. The unit shall have automatic for ce shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27Degree C DB and 19 Degree C WB temperature. Make Daikin,Hitachi,Mitsubishi,Carrier (i) 1.5TR
Touch screen controller for indoor units controller - VRV Touch screen controller for indoor units controller - VRV Supply, installation, testing and commissioning of LED Display Type Centralized Controller (Which can control 364 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls. Cordless Remote Control.
Supply of Cordless Remote Control for AC units
SITC of IR Receiver in indoor units to enable them for operation through Cordless remote
Supply, installation, testing and commissioning of imported refrigerant Y- joints/ headers.
Supply,Installation,testing and commissioning including vaccum iazation and Nitrogen testing of following nominalsizesofsoft/hard drawn copper refrigerant piping forVRV/VRFsystem, complete with fittings, with suitable adjustable ring type hangersupports ,jointing/brazing including accessories, insulated with XPLEClass-Otubular insulation/withClass-Oclosedcellelastometric nitrile rubber tubular sleeves section sofspecified thicknessas given below for Suctionand Liquidlines, all accessories as per specifications etc. as required : (i) 41.3 mm OD (Hard drawn) with tube thickness 1.62mm with 19mm thick insulation
34.9 mm OD (Hard drawn) with tube thickness 1.62mm with19mm thick insulation
28.6 mm OD (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation
22.2 mm OD (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation
19.1 mm OD (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation
15.9 mm OD (Soft drawn) with tube thickness 1.2mm with 19mm thick insulation
12.7 mm OD (Soft drawn) with tube thickness 1.2mm with 19mm thick insulation
9.5 mm OD (Soft drawn) with tube thickness 1.2mm with 19mm thick insulation
6.4 mm OD (Soft drawn) with tube thickness 1.2mm with 19mm thick insulation
Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller.
Supply, installation, testing, termination and commissioning of control cum transimission wiring of 4C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units for Split AC
Providing and fixing and in position the following PVC pipes (minium 15kg/cm2 pressure) for condensate drain duly insulated with kinny foam & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the shaft dor vertical risers). (i) 25mm dia
32 mm dia
250 KVA DG Supply, transporting, loading, unloading, erecting, testing and commissionig etc. of Silent Type Diesel Generating Set of 1500 KVA, 3 phase & neutral, 50 c/s. 415 A.C. rating, comprising of following Diesel Engine, Alternator, Sound Attenuated Acoustic Enclosure, including necessary RCC foundation for errection including earth work as required and with other associated accessories: Diesel Engine Diesel engine 4 stroke Water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50%RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour included in 12 hours of continuous operation. The engine will be fitted complete with all the required accessories Engine mounted Instrument Panel fitted with and having digital display for following: Start-Stop switch with push button, Water temperature indication, Lubrication Oil pressure indication, Battery charging indication, RPM indication, Over speed indication, Engine Hours indication, Digital electronic governor/digital voltage regulator, Battery monitoring system & weak battery warning, ,Digital metering for current, voltage, PF, KWH, KVA, Alternator protection for under/over voltage, under/over frequency, reverse power, over current., Alternator: Alternator rated at 250 KVA, 415 volts at 1500 RPM, 3 phase 50 HZ, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty self excited and self-regulated through AVR conforming to IS :4722/BS 2613 suitable for tropical condition and ambient temperature at 50 Degree C and as per manufacturer's standard specifications with class-H insulation. Auto Start/Auto load management should be through controller type 3300 or approved equipment. with suitable Breaker, Base Frame & Foundation:, Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary PCC block of 1:1.5:3 ratio of cement concrete of depth of 300 mm with suitable reinforcement which shall be installed on existing hard concrete floor and vibration isolation arrangement as per recommendation of manufacturer. Exhaust System:, Dry exhaust manifold of suitable dia, welded blank MS pipe confirming to IS:3589 cut to required lengths (max. 2 mtrs) and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with 50mm thick mineral wool/Rockwool, wire mesh and aluminium cladding 0.8 mm thick etc. as required as per specifications with hospital exhaust silencer., Starting System: D.G Set Describe as above The item rate shall include the cost of diesel for 8 Hrs. Testing at project site.
Supply, erection, testing and commissioning of MS exhaust piping horizontal run as per IS 3589& 1239 of following sizes with welding joint including bends, MS pipe, clamps, dash fastener, nuts, bolts etc. with insulation by applying MAS-17 adhesive then a layer of minimum 75 mm thick rockwool (150Kg/Cub Mtr.) covered with 24 SWG aluminium sheet claddings etc. complete as required and as per specifications. (i) 200 mm dia. NB (4.85mm Thickness)
250 mm dia NB (4.85mm Thickness)
Supply, erection, testing and commissioning of MS exhaust piping vertical run as per IS 3589& 1239 of following sizes with welding joint including bends, MS pipe, clamps, dash fastener, nuts, bolts etc. with insulation by applying MAS-17 adhesive then first layer of insulation 25mm thick ceramic fibre wool (96Kg/Cub. Mtr.) & second layer minimum 100mm thick rockwool(150Kg/Cub Mtr.) covered with 24 SWG aluminium sheet claddings etc. complete as required and as per specifications. (i) 200 mm dia. NB (4.85mm Thickness)
250 mm dia NB (4.85mm Thickness)
Supply & Fixing of SS expansion joints for horizontal/ vertical exhaust pipes as required at site: (i) 200 mm dia. NB (4.85mm Thickness)
Supply, erection, testing and commissioning of insulation by applying MAS-17 adhesive then layer of minimum 100mm thick rockwool(150Kg/Cub Mtr.) covered with 24 SWG aluminium sheet claddings etc. complete as required on silencer and as per specifications. Note : Silencer shall be part of standard supply with DG Set. (i) For 250 KVA DG Set
APPROVAL OF STATUTORY AUTHORITY: Preparation of drawings/documents in required sets to be submitted to statutory authority, obtaining approval/permission of electrical installation for operation of DG Sets as standby source, including Liasioning with Electrical Inspector/Local Supply Authority/Pollution Control Board etc. complete as required.
HT SWITCHGEAR OUTDOOR TYPE 11kV 630Amps 20kA for 3 sec. & tested for 20kA/ 1 sec internal arc , SF6 insulated Non-Extensible Compact switchgear consisting of One No. Direct Module for Incomer and one No. of Fixed Manual Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure with series trip,self powered microprocessor based numerical over current and Earth Fault (IDMT+Inst.) relay protection along with. Interconnection between HT switchgear and transformer shall be using 1Cx3x240 sq.mm Al. unarmorured XLPE Cable. NEAR METER ROOM
CSS SYSTEM Supply of 11kV compact secondary substation suitable for Outdoor installation with natural cooling, having type tested equipments comprising of oil-type distribution transformer and SF-6 insulated compact switchgear enclosed in robotically sealed stainless steel tank, low-voltage switchboard, interconnection between HT switchgear and transformer using cables and transformer to LT-switchgear using aluminium busbars, factory built ready for connection type, internal GI earthing provided complete with other associated equipments etc. complete as required conforming to IEC 62271-202 and relevant IS or international specifications, as regards to design, manufacturing, type-testing, routine-testing and operator safety (IAC AFLR). The enclosure shall have modular construction using G.I. Sheet and shall be powder-coated from exterior. Fixed Manual Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure with series trip,self powered microprocessor based numerical over current and Earth Fault (IDMT+Inst.) relay protection along with. Interconnection between HT switchgear and transformer shall be using 1Cx3x240 sq.mm Al. unarmorured XLPE Cable. TRANSFORMER 1no. 630KVA 11KV/433V Dyn11 Oil filled hermatically sealed transformer without conservator type of design having corrugated tank & Top normal porcelein Bushings for HT & LT with OLTC and RTCC switch of rating +5% to -15% @2.5%. Temp Rise - Oil/Winding 40/50 deg cel, NL/FL Losses = 1.4/14 KW (Subject to IS Tol.), Impedanace 5% (Subject to IS Tol.) Oil temperature Indicator, Winding Temperature indicator with Alarm and Trip Contact, LVS PANEL -1250AMPS ALUMINIUM BUSBARS, INCOMER, 1 Nos. 1000A, 50KA 4 pole microprocessor based EDO, ACB with integral protection, OUTGOING, Direct Cable termination Suitable for 4 nos 3.5 core 300 sqmm, 1100 V grade, XLPE insulated PVC sheathed Arnoured Aluminium cables, APFC (Automatic Powerfactor control), 200 kVAR APFC with 50X2, 25X2, 15X2,10X2 KVAR MPP type capacitor with MCCB/MCB/contactor & 10 step RVC relay with 400 Amp. 3P MCCB for incomer to APFC., OUTDOOR ENCLOSURE, Outdoor type enclosure with slanted roof & having construction of Galvanised Sheet Steel of thickness 1.5/2mm. The enclosure shall be type tested for IAC 20 kA/ 1 sec AB class as well as impact test as per IEC 62271-202 or international standards with reports not later than 5 years. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment with transformer compartment thermal class of K-20 as per latest IEC. The enclosure shall be Powder Coated (Colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment., INTERCONNECTION AND EARTHING, Interconnection Between HT switchgear & Transformer using 1Cx3x240Sq.mm XLPE Single core cable & Interconnection between Transformer & LT switchgear using Aluminium Busbars. Internal earthing connections by using 50x6 mm GI strips. Supply Rate for 11 kV Compact Substation as per specification & as described above
Providing and fixing 10 KW Solar Panel MNRE/NISE approved with 10 KW solar inverter/PCU make Eppro/Luminous with 10 Nos. Solar Battery make Luminous/Liveglant with ACDB Box complete with MCB/SPD etc. and DCDB Box Complete with DCMCB Connectors & Controls etc. & 2 mm thick Spicher - Complete Solar Plant Off grid with installation including Earthings etc.
Bidder Name
Amount
Sanjay Kumar, Contractor(GSTN-NA)
SATISH KUMAR GUPTA INFRA PRIVATE LIMITED(GSTN-NA)
SATISH KUMAR GUPTA INFRA PRIVATE LIMITED
SATISH KUMAR GUPTA INFRA PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid