Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹74.3 L+₹27.4 L (58.5%)Rejected-Finance | L2 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
3 Feb 2023, 6:00 pmClosed
GARRISON ENGINEER NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS REPLACEMENT OF EXTERNAL ELECTRICAL SERVICES DG SETS EXTERNAL WATER SUPPLY REPAIRS TO PUMPS ETC UNDER AGE E M NORTH OF GE NORTH BANGALORE
2022_MES_570942_1
8338
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bangalore
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹80,000
Yes
3 Mar 2023
23 Dec 2022
6 Feb 2023
23 Dec 2022
3 Feb 2023
6 Jan 2023
23 Dec 2022 - 6 Jan 2023
Amount
M & L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the sump suitable to store potable drinking water incl one coat white washing inside and marking out side sump in visible place the capacity of sump, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following sumps:- Capacity of 5000 gallons at NTG/NLC
As per item No. 1 above but for Capacity of 50000 gallons at Naval Detachment
Removing old unserviceable float valve from service tank and supply & fix float valve with PVC body aluminium float rod, nylon float high presure type (Make:- Prayag)for the following size:- 20 mm bore
Disconnecting the electric cable from the terminal box of 5HP motor, Decoupling the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop and performing following works as specified and directed by Engr-in-Charge (i) Dismantling the motor and taking out the burnt out copper winding / fiber strip / insulating materials and worn out ball bearing - 2 No. (ii) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials / fiber strip / varnishing and made terminal connection of fiber glass coated wire. (iii) Replacement of ball bearing - 2 No. (iv) Assembling the motor and painting with two coat of primer and one coat of synthetic enamel paint including marking flow of water and MES NO all as per norms and all as specified and as directed as directed by the Engr-in-charge. (v) Transporting to the motor to the site refixing on foundation channel with new bolts and nuts, coupling the pump and motor with correct alignment apply grease and connecting electrical connections testing complete alll as directed and specified by the Engr-in-charge.
Disconnect the electrical connection, Lifting the submersible pumpset with 50mm GI pipe from 500 to 700 feet depth bore well of 03 HP to 7.5 HP capacity and dismantling the pump set and replacing the damaged impeller, bearing , bushes, stainer as per exisiting size and assembiling the same including necessary lathe works, fixing the motor and proper insulation, connecting and testing and lowering the same and testing and commissioning all as directed at specified by the Engr-in-charge
Removing the defective single phase preventer from star/delta starter and supply and fixing new single phase preventer suitable for various capacity of motors (make : L&T or equivalent) 60/40/30/25/20/15/12.5/10/7.5 and 5 HP
Repair to the star/delta starter fully automatic & different starter including replacing with new spares ie. Contactor, timer, relays etc suitable for existing make and capacirty of ML1/ML2/ML3/ML4/ML1.5/MK1. Note : Spares shall be measured and paid separately.
Dismantling the existing old pressure gauge from the pump set/water supply line and provision of new pressure guage 1-10.6 kg per sq cm 100 mm dia dial 3/8" threaded type with stop cock arrangement.
Dismantling the existing old Vacuum gauge from the pump set/water supply line and provision of new pressure guage 0-760 mm Hg pressure 100 mm dia dial 3/8" threaded type with stop cock arrangement.
Supply and Fix in replacement of new pump shaft as per existing size of the following capacity pump sets (Make Kirloskar) (a) upto and inculding 7.5 HP Pump Set
Dismantaling the old shaft and performing the necessary work and remetalling the shaft as per existing size of the following capacity pump sets (a) upto and inculding 7.5 HP Pump Set
Supply and fixed in replacement starter contactor assembly of ML 1.5 Type Make L & T Cat No. SS91851.
Prepartion of surface and applying one coat of painting with approved synthetic enamel paint to external surface of pipes of sizes 200mm / 150mm / 100mm / 80mm / 50mm dia and marking arrows indicating direct flow with approved enamel paint all as specified and as directed by the Engineer-in-Charge.
Taking up the GI pipes with fittings and connected control gate valves/ Sluice valve/non return valve/foot valve etc. from sump/ trenches/ floors/roof for the following size:- . 80mm dia
As per item No. 14 above but for 50mm dia
As per item No. 14 above but for 25mm dia
As per item No. 14 above but for 20mm dia
S&L galvanised pipes, "Medium grade", complete in tenches / on walls including all fittings like tees, collars, Elbows, Unions etc all as directed for the following :- 80 mm dia GI Medium grade pipe.
As per item No 18 here in-before, but for 50 mm dia GI Medium grade pipe.
As per item No 18 here in-before, but for 25 mm dia GI Medium grade pipe.
As per item No 18 here in-before, but for 20 mm dia GI Medium grade pipe.
S & F Voltmeter (0-500 V), Ammeter (0-400A) (Make Meco) & indication lamps (set)
Removing of unserviceable foot valve from tank and replacement with new CI foot valve of following sizes:- 50 mm dia bore
S&F Electronic Timers ST 100 operating range of 160V to 500V make L & T cat No. ST80328OOOO / ST80329OOOO as required
Dismantaling the sluice valves in various location and reconditioning the sluie valve by replacing SS spindle, spindle nuts with brass ring, gland nuts, gland packing etc and refixing after properly repairing of the following sizes :- 100 mm dia bore
As per items No. 25 above but for 80 mm dia bore
S & F in replacement of sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with brass spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insertion packing 6mm thick etc of following sizes:- 100 mm dia bore
As per items No. 27 above but for 80 mm dia bore
Supply & fixing in replacement gun metal Gate valve with iron wheel of the following size :- 15 mm dia
As per items No. 29 above but for 20 mm dia
As per items No. 29 above but for 25 mm dia
As per items No. 29 above but for 40 mm dia
As per items No. 29 above but for 50 mm dia
Material and labour for repacking stuffing box of sluice valve spindle including taking a part and reassembling of following sizes:- 80 mm bore
Supply & laying in replacement of flat 3 core copper cable of size 4 Sqmm.
Taking out the existing unsv LT panel & supply & fixing of new accessories like starter single phase preventor, fuse cut outs, indicating lamp etc suitable for 5 HP, submersible pump set for outdoor application. Note :- Job includes necessary civil works such as foundation, grounding of panel etc & connecting back existing old cables.
Excavation in trenches not exceeding 1.5 m depth and not exceeding 1.5m width and getting out in hard/dense soil for laying of pipe lines, laying of cables/errection of pole complete all as specified and as directed. .
Returning, refilling incl spreading, levelling watering and well ramming in layers not exceeding 25 cm thick with any type of soil all as directed
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified as directed.
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed
S & L sub class burnt bricks for cable protection complete as specified as directed.
Boring of holes under road, pavement, hard standing by trenchless techless using ultra sounding technique and necessary machine including HDPE pipe of 80 mm dia bore suitable for 0.4 mpa working pressure.
Taking down old unsv/burnt XLPE cable from trench/wall/pole of following size :- 2 C x 10 Sqmm
As per items No. 43 above but for 4 C x 16 Sqmm
As per items No. 43 above but for 4 C x 10 Sqmm
As per items No. 43 above but for 4 C x 35 Sqmm
As per items No. 43 above but for 3.5 C x 35 Sqmm
As per items No. 43 above but for 3.5 C x 50 Sqmm
As per items No. 43 above but for 3.5 C x 70 Sqmm
As per items No. 43 above but for 3.5 C x 95 Sqmm
As per items No. 43 above but for 3.5 C x 120 Sqmm
As per items No. 43 above but for 3.5 C x 150 Sqmm
As per items No. 43 above but for 3.5 C x 240 Sqmm
Laying only XLPE cable of 1100 volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable for following size :- Note:- i) XLPE cable will be issued under Sch 'B' Item free for fixing. ii) Earthwork, sand cushnoing and covers will be measured and paid separately. 2 C x 10 Sqmm
As per items No. 54 above but for 4 C x 16 Sqmm
As per items No. 54 above but for 3.5 C x 35 Sqmm
As per items No. 54 above but for 3.5 C x 50 Sqmm
As per items No. 54 above but for 3.5 C x 70 Sqmm
As per items No. 54 above but for 3.5 C x 240 Sqmm
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable for following size :- Note:- i) Earthwork, sand cushnoing and covers will be measured and paid separately. 3.5 C x 95 Sqmm
As per items No. 60 above but for 3.5 C x 120 Sqmm
As per items No. 60 above but for 3.5 C x 150 Sqmm
As per items No. 60 above but for 4 C x 10 Sqmm
As per items No. 60 above but for 4 C x 16 Sqmm
As per items No. 60 above but for 4 C x 35 Sqmm
M & L for GI tubing light grade 40mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items.
M & L for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items.
M & L for GI tubing light grade 80mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized iron strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized iron earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
M & L for tightening of ACSR (Aluminium conductor steel reinforced) conductor of any size between two poles 06 runs of conductor incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed
Taking down the unserviceable one and S&F MCCBs 4 pole 415 Volts 50HZ incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under:- Make INDOASIAN or equivalent. MCCB 100 Amps ,16 KA with adjustable Thermal setting
As per items No. 72 above but for MCCB 100 Amps ,36 KA with adjustable Thermal setting
As per items No. 72 above but for MCCB 125 Amps ,36 KA with adjustable Thermal setting
As per items No. 72 above but for MCCB 200 Amps 36 KA with adjustable Thermal setting .
As per items No. 72 above but for MCCB 250 Amps 36 KA with adjustable Thermal setting .
As per items No. 72 above but for MCCB 315 Amps 36 KA with adjustable Thermal setting .
As per items No. 72 above but for MCCB 63 Amps, 25 KA with adjustable Thermal setting
As per items No. 72 above but for MCCB TPN 63 Amps, 16 KA 4 poles-1 no with adjustable Thermal setting
Taking down old cable joint and Supply and fix cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core/4core XLPE armoured aluminium conductor cable for following sizes:- 3.5 C x 25 to 35 Sqmm
As per items No. 80 above but straight through joint for 3.5 C x 50 to 120 Sqmm
M&L for painting of steel tubular/PCC poles of any height and type ,incl security light mounting brackets with one coat of aluminium paint/two coat of cement base paint incluing painting black and yellow strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of pole complete all specified and as directed.
Dismantling of ACSR (Aluminium conductor steel reinforced) conductors
M&L of ACSR (Aluminium conductor steel reinforced) conductor of any size on poles incl binding wire of appropriate size complete incl clearing of path and branch cutting etc complete all as specified and as directed
Refixing of ACSR conductor connected with new existing wire tightening to insulator incl line clearance by pruning of tree branch approx 1 m apart from conductor tightening side complete all as directed by Engr-in-charge.
Supply & Fix in replacement of GI pipe bracket on pole/ wall etc made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed.
Supply and fix in replacement of Timeline distribution board 32 A 3 pole /230V analog time switch including complete accessories relay contactor, timer etc, all as specified and as directed. Make:- Indoasian Cat No. TL032AB0
M&L for Busbar chambers Wall/Angle mounted of copper busbar with sheet metal enclosure box of suitable size for 6 way, 4 pole, 50 Hz, 415V of capacity 400 A complete all as specified and directed as per Model No IHBC040006. Make : Havells complete all as specified and as directed
M&L for outdoor type, double door sheet metal enclosure/Junction box of size 80x80x30 cm with aluminium bus bar 160 Amps for 3 phase & neutral including MCCB 4 pole 415 volts 100 Amps 36 KA .including removing old unserviceable junction box complete all as specified and as directed
M&L for outdoor type, double door sheet metal enclosure/Junction box of size 80x80x30 cm with aluminium bus bar 400 Amps for 3 phase & neutral including MCCB 4 pole 415 volts 320 Amps 36 KA .including removing old unserviceable junction box complete all as specified and as directed
M&L for cable finding cable fault in LT cables any sizes complete all as specified and as directed
Taking down old unserviceable and supply & fixing moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with and inculding cost of one 6 Amp MCB SP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole complete all as directed
Taking down old unserviceable supply & fix on load Change over switch 4 pole in sheet metal enclosure compact design rating 100 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks Make :- INDOASIAN Cat No.ICAS0400 or Havells/L&T/ Standard.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
All as per ser no 94 but 2.5 mm thick for voltage upto 11 kv (size 2m x 1 m).
Supply, testing and commissioning of weather and vermin proof LT feeder pillar box factory fabricated outdoor cubicle/kiosk type CPRI approved and confirming to IS 5036 totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with powder coated, Contd/--97
Supply, testing and commissioning in replacement of weather and vermin proof LT feeder pillar box factory fabricated outdoor cubicle / kiosk type CPRI approved and confirming to IS 5036 totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel, centre opening, front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC / rubber bushes to prevent ingress of water / vermin etc, inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor
Taking down Outdoor / Indoor type LT Panel of any size by disconnecting all LT connection and shifting from one location to another location by the help of chain pulley/crane and re-connecting to LT connection at new location all as specified and directed by Engr-in-charge. (FMME Sub Station Lt Panel shifted to JCOs Mess).
Supply and fixing 60 W LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08, 4KV inbuilt and 10 KV external surge protection with top opening driver cover for easy maintenance including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- ENXT P 72 L WH CR PC SD or equivalent in Havells / Philips / CG.
Supply and fixing 70 Watt next generation LED street with pressure die-cast housing alongwith prismatic polycarbonate modular secondary lensoptics for city road application with IP-66 ingress protection and impact resistance of IKO8, 4KV inbuilt and 10 KV external surge protection with top opening drive cover for easy maintenance including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- ENXT P 84L WH CR PC SD or Equivalent in Havells/Phillips/ CG.
Supply and fixing 90 W LED street light fitting with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics with IP 66 ingress protection and impact resistance of IK 07, 5KV inbuilt and 10KV external surge protection with top opening driver cover for easy maintenance including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- BRTFG 90W LED CR or equivalent in Havells / Philips / CG.
Supply & lay of 03 core 2.5 sqmm PVC insulated cable with mulitstanded copper PVC insulated sheathed cable with multistanded copper conductor 1100 volts grade cofirming to IS 694 including drawn throgh the steel tubular pole and connection to light fitting and MCBs incl taking old unserviceable cable complete all as specified and as directed.
S&F of LED bollard of 09 Watts, square (in plan) shaped extruded aluminium housing with opal acrylic diffuser fixed in die cast aluminium frame and IP 65 protection complete including PCC work (1:2:4) as foundation for mounting bollard of size 30x30x30cm and one way DB box with MCB SP 6 Amps fitted inside including connection from the MCB to lights using 1.5 Sqmm three core cable incl taking old unserviceable one all as directed. Make : Bajaj, Cat No : BGBOS 605 9W LED or equivalent make of Havells/Crompton /Phillips.
Dismanling and taking down old unserviceable CFL type street light fittings from Pole, removing the unserviceable CFL and S&F new LED bulb 40 watt with suitable size holder and refixing the existing/new location all as directed at site. Make :- Bajaj
Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 25 W to 60W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site.
Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 90 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site.
Dismanling and taking out the flood light from high mast pole and removing the burned out/unserviceable LED driver 200 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site.
Supply & Fix 200W LED flood light luminaries with ultra sleek, light weight and with secondary optics, made of pressure die cast housings with IP 66 ingress protection and impact resistance of IK 07, 4kV inbuilt and 10 kV external surge protection, suitable for highmast lighting with complete accessories including taking down old unserviceable flood lights from high mast pole all as specified and as directed. Make:- BAJAJ, Code No. : BJFL 200W LED I
M&L for painting of outdoor type Feeder piller panel upto the size of 1100 x 450 x 1200 mm (approx), incl replacement of door hinges if unsv new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed.
Maintenance/Servicing, Cleaning, Descaling of solar water heating system complete of capacity 100/200 Ltr per day with 02 Nos of collector of any size 01 No of stainless steel tank and 01 No of plastic make up tank 500 Ltr by replacement of washers, gasket, adaptor and worn out nut bolt, GI fitting for water pipe line 20/25 mm for inlet and outlet of stainless steel tank/collector /water make up tank and making fully leak proof by brazing/welding of the inner container for arresting leakages complete and testing for satisfactory performance all as specified and directed.
All as per item No. 112 above but of capacity 300 Ltr per Day including the following:-
S&F in repairs 200 LPD Stainless steel Water heater tank of thickness as per existing SS Tank complete all as specified and directed
S&F in replacement black hose pipe suitable for 20/25mm dia hot/cold water pipe for solar hot water system all as specified by Engr -in Charge
Supply and Fix in replacement Electric heating element 3KW, ISI Marked threaded/cup type to SS tank of solar water heating system 200 ltrs capacity with necessary fixtures including taking out unserviceable one complete all as specified and directed by Engr-in-Charge.
Supply, installation, tesing and commissioning in replacement of Lithium based Solar Security light System with bult in Battery and PV Panel and LED lamp in FRP body and including taking down of old unserviceable light fitting of any size/capacity complete system comprises followings:- (a) PV Panel 30 W Monocrystalline. (b) Lithium cell for back up 15.4 AH with inbuilt BMS. (c) High brightness W-LED lamps 15W, CRI>700, CCT 6500K. (d) Microcontroller based charge controller cum diriver with automaic dimming dunction, Operation. (e) Working temperature; (-) 10 degree C to (+) 55 degree C. (f) System shall be supplied with adjustable MS clamp and 40 mm dia arm suitable for pole/wall mounting complete with satisfaction of Engineer-in-Charge. Make Bajaj/Philips/Havells/Syska.
S&F in replacement of 45 Watt post top LED light fitting, die cast aluminum graphite grey powder coated spigot, Acrylic clear diffuser, spun aluminum power coated canopy, LED connected in series and paralled combination either better heat dissipation arrangement, LED colour 3000 K + 300K, open and short circuit protection, voltage surge protection 5KV, suitable for 60mm OD pipe entry with fixing bolts, IP-65. Make :- Bajaj Cat No. BGCT W4 LED WH or Equivalent in Havells/Phillips/Crompton.
Comprehensive maints / periodical maintenance / servicing and repair of standby Eco Friendly/Acoustic type DG set 500 KVA at ADMC area of any Make. 'A' Check Monthly & 'B' check 250Hrs or 3 Months which ever is earlier. Note : 1. As per maintenance schedule prescribed in repair and maintenance manual (Repair & maintenance should be carried out by the qualified and experianced mechanic from the authorised servicing centre who is conversant with the DG set and report should be submitted by the contractor) 2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work Condt/--120.
Condt/--119. Checking and servicing includes the following :- 'A' & 'B' check (i) Lubricant oil leaking. (ii) Operation and repairs to lubricant oil leakage and cooling system leakage, radiator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system. (iii) Leaking in air intake system, maintenance filter & air cleaner piping connection. (iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments (v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust manifold and turbo charger cap screw. (vi) Battery charging system & topping up electrolyte and maintenance of specific gravity (vii) Cleaning of engine tighten of all nut bolt washer and unusual vibration. (viii) Checking to electric connection & smooth operation of generator control panel, greasing to all bearing and movable part, measurement and recording winding insulation resistance cleaning up complete generator/alternator.
Supply only following parts of DG sets as specified under ser item No 119 all as per recommendation of manufacturer and all as directed. Note:-Taking down & fixing charges will be included in SL No.119 Supply only Fan belt
As per items No. 121 above but for Supply only Fuel filter
As per items No. 121 above but for Supply only Oil Filter
As per items No. 121 above but for Fuel tank cleaning
As per items No. 121 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 121 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 200 KVA at CQAL and 2 PARA (SF)
Supply only following parts of DG set 200 KVA specified under ser item No 127 and replacement as per recommendation of manufacturer & all as directed. NOTE:-Taking down & fixing charges will be included in SL item No 127 Fan belt all as per manufactures recommendations
As per items No. 128 above but for Supply only Coupling main alternator
As per items No. 128 above but for Supply only Fuel filter
As per items No. 128 above but for Supply only Oil Filter
As per items No. 128 above but for Supply only Air Filter
As per items No. 128 above but for Fuel tank cleaning
As per items No. 128 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 128 above but for Servicing of self starter
As per items No. 128 above but for Supply only fuel water separator. Make Fleetguard.
As per items No. 128 above but for Supply only coolant filter. Make Fleetguard.
As per items No. 128 above but for Supply only Oil sensor.
As per items No. 128 above but for Supply only Coolant sensor.
As per items No. 119 above but for Capacity of DG set 160 KVA at TB-II pump house and at NCN
Supply only following parts of DG set specified under ser item No 140 all as per recommendation of manufacturer & all as directed NOTE:- Taking down & fixing charges will be included in SL item NO 140. Supply only Fan belt
As per items No. 141 above but for Supply only Coupling main alternator
As per items No. 141 above but for Supply only Fuel filter
As per items No. 141 above but for Supply only Oil Filter
As per items No. 141 above but for Supply only Air Filter
As per items No. 141 above but for Fuel tank cleaning
As per items No. 141 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 141 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 125 KVA at Assaye Parade Pump House/ IWMT.
Supply only following parts of DG set specified under ser item No 149 all as per recommendation of manufacturer & all as directed. NOTE:- Taking down & fixing charges will be included in SL item NO 149. Supply only Fan belt
As per items No. 150 above but for Supply only Fuel filter
As per items No. 150 above but for Supply only Oil Filter
As per items No. 150 above but for Servicing of self starter
As per items No. 150 above but for Fuel tank cleaning
As per items No. 119 above but for Capacity of DG set/DD Pump Set 100 KVA at ML Pump House/ADMC.
Supply only following parts of DG set specified under ser item No 155 all as per recommendation of manufacturer & all as directed. NOTE:- Taking down & fixing charges will be included in SL item No 155. Supply only Fan belt
As per items No. 156 above but for Supply only Fuel filter
As per items No. 156 above but for Supply only Oil Filter
As per items No. 156 above but forut for Supply only Carbon brush
As per items No. 156 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 156 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 82.5 KVA at HQ NTG/NLC.
Supply only following parts of DG set specified under ser item No 162 and all as per recommendation of manufacturer & all as directed. NOTE:- Taking down & fixing charges will be included in sl No 162. Supply only Fuel filter
As per items No. 163 above but for Supply only Oil Filter
As per items No. 163 above but forr Fuel tank cleaning
As per items No. 163 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 163 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 62.5 KVA at Gunatha Vihar, STB Hebbal / MDC (Dental)
Supply only following parts of DG set specified under ser item No 168and all as per recommendation of manufacturer & all as directed. NOTE:- Taking down & fixing charges will be included in sl No 168. Supply only Fuel filter
As per items No. 169 above but for Supply only Oil Filter
As per items No. 169 above but for Fuel tank cleaning
As per items No. 169 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 169 above but forr Servicing of self starter
As per items No. 119 above but for Capacity of DG set 50 KVA at DIQA Pump House and Depot Bn Pump house
Supply only following parts of DG set specified under ser item No.174 all as per recommendation of manufacturer as directed NOTE :-Taking down & fixing charges will be included in sl No 174. Supply only Fan belt
As per items No. 175 above but for Supply only Fuel filter
As per items No. 175 above but for Supply only Oil Filter
As per items No. 175 above but for Fuel tank cleaning
As per items No. 175 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 175 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 35/40 KVA at TB-III Pump House / MEG Records / PRTC / STP MEG/Raw Water PH House TB-III.
Supply only following parts of DG set specified under ser item No.181 all as per recommendation of manufacturer as directed NOTE :-Taking down & fixing charges will be included in sl No 181. Supply only Fan belt
As per items No. 182 above but for Supply only Hose Fuel suction/return
As per items No. 182 above but for Supply only Fuel filter
As per items No. 182 above but for Supply only Oil Filter
As per items No. 182 above but for Fuel tank cleaning
As per items No. 182 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 30 KVA .at (DIQA) DGI Tech Accn/ CQAL Pump house and NOM Naval detachment and at Assaye line / CICE/FMME.
Supply only following parts of DG set specified under ser item No. 188 and all as per recommendation of manufacturer.as directed. NOTE ;- Taking down & fixing charges will be included in sl item No 188. Supply only Fan belt
As per items No. 189 above but for Supply only Hose Fuel suction/return
As per items No. 189 above but for Supply only Fuel filter
As per items No. 189 above but for Supply only Oil Filter
As per items No. 189 above but for Fuel tank cleaning
As per items No. 189 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 189 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 20/25 KVA at MAP Ph-I/FMME/ 2 PARA (SF) / Chowdhury line Pump House/ GE Office / STB Hebbal / Para Records/ TB-I Pump House/RC Line .
Supply only following parts of DG set specified under ser item No 196 as per recommendation of manufacturer as directed. NOTE:-Taking down & fixing charges will be included in sl No 196. Supply only Fan belt
As per items No. 197 above but for Supply only Fuel filter
As per items No. 197 above but for Supply only Oil Filter
As per items No. 197 above but for Fuel tank cleaning
As per items No. 197 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 197 above but foror Servicing of self starter
As per items No. 119 above but for Capacity of DG set 15 KVA at Central MI Room/Mandlay line/TB-I Pump House. .
Supply only following parts of DG set specified under ser item No.203 as per recommendation of manufacturer as directed NOTE:-Taking down & fixing charges will be included in sl No 203. Supply only Fuel filter
As per items No. 204 above but for Supply only Oil Filter
As per items No. 204 above but for Servicing of self starter
As per items No. 119 above but for Capacity of DG set 12.5 KVA at 106 (TA) Inf Bn Pump House/ Mandaly Lines Pump House.
Supply only following parts of DG set specified under ser item No.207 as per recommendation of manufacturer all as directed NOTE:-Taking down & fixing charges will be included in sl No 207. Supply only Fuel filter
As per items No. 208 above but for Supply only Oil Filter
As per items No. 208 above but for Cleaning / Descaling of radiator internally and externally .
As per items No. 208 above but for Servicing of self starter Note :- For item No. 119 to 207 Engine oil and coolant will be measured & paid separately under Sl item No. 212 & 213
Supply & filling Engine Oil 15W-40
Supply & filling Coolant premixture
Dismantling DC dynamo/alternator of battery charging system 12/24V complete servicing including replacement of bushes, bearings, Carbon brushes, diodes any other minor parts required all as directed & fixing on engine testing/commissioning complete for any capacity of DG Set
Material and labour for replacement of unserviceable contactor AC operated 4 pole 415 Volt suitable for the following capacity of DG Set as per the existing in the AMF panel of same make/model. DG Set 500 KVA
As per items No. 215 above but for DG Set 200 KVA
As per items No. 215 above but DG Set 200/160 kVA
As per items No. 215 above but DG Set 160 kVA
As per items No. 215 above but DG Set 82.5 kVA
As per items No. 215 above but DG Set 62.5/100 kVA
As per items No. 215 above but DG Set 30 kVA
As per items No. 215 above but DG Set 20/25 kVA
S&F in replacement of Fuel pipe PVC metal braided of length 0.8 mtr long fitted with benzo adopters to both sides with benzo bolts & washers.
Repair and servicing of existing canopy of eco friendly DG Set of any capacity cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations complete all as directed.
Repair /replacement of PCB board of 30 to 200 KVA (Make : Kirloskar) etc complete all as specified as directed
Repair /replacement of PCB board of 30 to 160 KVA (Make : Kirloskar) etc complete all as specified as directed
Repair /replacement of PCB board of 12.5 to 200 KVA (Make : Kirloskar) etc complete all as specified as directed
Dismantling self starter of engine of DG set capacity 30 KVA to 200 KVA & repairing the starter by replacing carbon brushes, bearings, solenoid coil, brush, brush holders complete rewinding, servicing refixing after repair, testing/ commissioning complete all as directed by Engr-in-Charge.
Dismantling self starter of engine of DG set capacity 30 KVA to 160 KVA & repairing the starter by replacing carbon brushes, bearings, solenoid coil, brush, brush holders complete rewinding, servicing refixing after repair, testing/ commissioning complete all as directed by Engr-in-Charge.
Dismantling self starter of engine of DG set capacity 12.5 KVA upto 200 KVA & repairing the starter by replacing carbon brushes, bearings, solenoid coil, brush, brush holders complete rewinding,servicing refixing after repair, testing/commissioning complete all as directed by Engr-in-Charge.
Supply and fix SCR controlled battery charger 12V /24V 15A with TRICKLE and BOOSTING facility, DC voltmeter, Ammeter, toggle switch etc in charge necessary connection from AC supply to Battery Charger and DC wiring to the battery with crocodile clip etc as required complete all as specified and as directed. Make : M/s. Naren or equivalent approved make.
ON line battery charger 12V with TRICKLE and BOOSTING facility etc in charge mode, necessary connection from AC supply to Battery Charger and DC wiring to the battery with crocodile clip etc as required complete all as specified and as directed.
Supply and fixing in replacement of Door hinges for DG canopy complete all as specified and as directed.
S&F Maintenance free Battery 12 volts 150 AH, complete all as specified and as directed. MAKE:- Exide/Amaron/microtek.
S&F maintenance free Battery 12 volts 80 AH, Make : Exide/Amaron/microtek.
S&F maintenance free Battery 12 volts 180 AH, Make : Exide/Amaron/microtek.
S&F LVM suitable for DG Set of capcity 20 KVA to 160 KVA.
S&F Solonoid switch for DG Set of capcity 20 KVA to 160 KVA.
M&L to repair AMF panel for DG Set of capcity 20 KVA to 500 KVA.
M&L for Add on block (Axilluary contract) for contactor for DG Set of capacity 20 KVA to 500 KVA.
M&L relay 170 ohm, 12 AA for control panel for DG Set of capcity 20 KVA to 500 KVA.
M&L KWh meter for DG set panel upto 500 KVA. Make : EIC or equivalent make.
M&L VAFhr meter for DG set panel upto 500 KVA. Make : EIC or equivalent make.
M&L Start/Stop push button for DG set panel upto 500 KVA.
S&F Oil temperture gauge for DG set upto 500 KVA.
S&F Oil pressure gauge for DG set upto 500 KVA.
S&F Hours run meter dial type for DG set upto 500 KVA alongwith connecting cable.
S&F RPM meter (Gernator safety unit) having all parameters Oil temperature/pressure gauge for DG set upto 500 KVA. Model No : GSU-904 of Make : SUN Industrial Automation & Solutions or equivalent make.
S&F in replacement of AVR of any type /size for three phase DG Sets upto 200 KVA as per existing make all as specified and directed. Make : Kirloskar or equivalent make.
S&F in replacement of inner Air filter element of any type /size for DG Sets upto 500 KVA as per existing make, type and size all as specified and directed. Make : Fleetguard/Cummins or equivalent make.
S&F in replacement of DG set transparent PVC door glass with nut and bolt/gasket for monitoring DG control panel from outside as per existing size.
S&F in replacement of battery lead of colour Red and Black for +ve and -ve suitable for Battery 12 Volt 180 AH alongwith copper lugs and brass terminal of suitable size.
M&L spare coil, 415 V (SP), 50 Hz for contractor for DG Set upto 500 KVA. Make : LT/GE.
Dismantling the existing alternator 35/40KVA from the exisitng base plate after disconnecting the electric connections and disassemble the alternator complete, removing the burnt out winding from the starter in a suitable way, cleaning, decarbonishing the starter, rotor and coating with epoxy insulation varnish after rewinding the startor with suitablecopper wire and insualtion, varnish it with replacement of bearing as per existing suitable size and make after reassembling coupled with engine connecting electric connections, commissioning and testing complete. (Rate for transportation for carrying alternator from site to nearest workshop and back will be deemed in this item rate).
Taking down old unserviceable HPSV/ HPMV street light fittings & Supply and fixing 70 W LED street light fitting with pressure die cast housing, toughened glass and indivudial LEDs with secondary optics and IP 66 protection. Make:- Bajaj, Cat No.:- Bajaj Cat No.:- ENXT P 84L WH CR PC SD or techno commercially equivalent
S&F in replacement of burned out /unserviceable constant current LED driver from LED bollard fittings from site with new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. Make : Havells. Model : YN2POIOPBCC1SN055/070V110_01.
M & L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for couping of pole,filling and mass concrete of pole, make good to road surface, hard standing etc incl necessary form work all as specified and as directed
Supply & fix in replacement of LED bollard 9 watt with opal acrylic diffuser and IP 65 protection Make :- Bajaj Cat No. BGBOM 650 9W LED
S&F in replacement of LED bollard of 09 Watts, square (in plan) shaped extruded aluminium housing with opal acrylic diffuser fixed in die cast aluminium frame and IP 65 protection complete including PCC work (1:2:4) as foundation for mounting bollard of size 30x30x30cm and one way DB box with MCB SP 6 Amps fitted inside including connection from the MCB to lights using 1.5 Sqmm three core cable all as directed. Make : Bajaj, Cat No : BGBOS 605 9W LED or equivalent make of Havells/Crompton /Phillips.
Maintenance / servicing, cleaning, descaling of solar water heating system complete of capacity 100 Ltr per day with 02 Nos of collector of any size 01 No of stainless steel tank and 01 No of plastic make up tank 150 Ltr by replacement of washers, gasket, adaptor and worn out nut bolt, GI fitting for water pipe line 20/25 mm dia for inlet and outlet of stainless steel tank / collector /water make up tank and making fully leak proof by brazing / welding of the inner container for arresting leakages complete and testing for satisfactory performance all as specified and directed.
Replacement of broken glass of solar flat plate collector of size 206 cm x 105 cm x 4 mm thick (L x B x W) (or as per existing size) by new one including rubber packing complete all as specified and as directed.
S&F ETC Tube 47mm dia/ 54mm dia, glass tube with copper coating fixed in repairs complete all as specified and directed.
S&F in replacement of Stainless steel water heater tank of capacity 100/150 LPD complete as per existing SS tank fixed all as specified and directed.
Supply and fix in replacement of Timeline distribution board 40 A 3 pole /230V analog time switch including complete accessories relay contactor etc, timer with battery back up all as specified and as directed. Make:- Indoasian Cat No. TL040AB0
S&F Electric heating element 3KW, ISI Marked threaded/cup type to SS tank of solar water heating system 100/150/200 ltrs capacity with necessary fixtures including taking out unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F Thermostat of any size and type as per existing type, ISI Marked for solar water heating system 100/150/200 ltrs capacity including taking out unserviceable one all as specified and directed by Engr-in-Charge.
Supply installation, testing and commissioning of LED Solar Street light All IN ONE TYPE with inbuilt battery, SPV Module of capacity 12 Watt of light source and 12 watt SPV panel, IP 65 protection, Lumionous efficacy 120 Lm /watt, Colour temperature 6000 K, battery 12.8 V, 12 AH including charging system with overload protection, light sensor devices , GI /MS pole of suitable dia of length 5 to 6 mtr duly painted etc all as specified and directed. Note : Excavation , PCC required for foundation as per the manufacturer reccomendation shall be included in the quoted rate. Make: Bajaj & Model no:- Model No: 152404 SOLAR BSZSL 12 W LED or equivalent in Philips / Haveels / CG.
Supply installation, testing and commissioning of LED Solar Street light All IN ONE TYPE with inbuilt battery, SPV Module of capacity 20 Watt of light source and 38 watt SPV panel, IP 65 protection, Lumionous efficacy 120 Lm /watt, Colour temperature 6000 K, battery 12.8 V, 18AH including charging system with overload protecion, light sensor devices, GI /MS pole of suitable dia of length 5 to 6 mtr duly painted etc all as specified and directed. Note : Excavation , PCC required for foundation as per the manufacturer reccomendation shall be included in the quoted rate. Make: Bajaj & Model no:- Model No: 152407 SOLAR BSZSL 20 W LED or equivalent in Philips / Haveels / CG.
Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing complete all as specified and as directed upto 100KVA/HP DG Set/DD Pump Set. Make Greaves/Kirloskar/Cummins.
Calibration of injector assembly including supply & fixing in replacement of the injector element plunger, DV, Governor wet, ‘O’ Ring required for smooth functioning of injector complete all as specified and as directed upto 100KVA/HP DG Set/DD Pump Set. Make- Greaves/Kirloskar/ Cummins.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .